Rosemount Transmitter Diagnostics Reduce Maintenance Costs

Similar documents
Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

HART Communicator. Emerson Process Management Catalog

FIELDVUE Instrumentation

3420 Fieldbus Interface Module (FIM) Contents

3051S HART Pressure Transmitter with Advanced Diagnostics. Statistical Process Monitoring Diagnostic Technology

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

Rosemount 1595 Conditioning Orifice Plate

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers


FREQUENTLY ASKED QUESTIONS

Commissioning Benefits

Gain better understanding and insight into your plant data

Dynamic Flow Computers, Inc Southwest Freeway, Suite 320 Stafford, TX Ph: (281) Fax: (281)

Safe & available...vigilant!

Solve Compliance, Integration & Process Challenges Using Rich Data From Your Instrumentation

SIS Operation & Maintenance 15 minutes

Certified Technical Training for Emerson Flow Instruments. Helping you to maximize your Flow instrument investment

Detection of Plugged Impulse Lines Using Statistical Process Monitoring Technology

HART COMMUNICATION. A Digital Upgrade For Existing Plants

M-series Foundation Fieldbus I/O

Advanced Test Equipment Rentals ATEC (2832)

The Calibration of Smart Instrumentation A Better Way

DELTA CONTROLS CORPORATION

Online Interfaces and Optional Features

Operating Instructions and Description of Instrument Function Prothermo NMT539

Mark Bitto / ABB Inc / PSPG / CIBO Technical Focus Group / June Instrumented and Actuated Systems Condition Monitoring of Rotating Equipment

Special Documentation Proline Promag 400 HART

Write Primary Variable Range Values Data written using command 35 will update the 4mA and 20mA settings in the menu.

PAST PRESENT & FUTURE TRENDS IN INDUSTRIAL AUTOMATION

Valve and Case Expansion Monitor Specifications

Process and Power Control

Fox Thermal Instruments, Inc.

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

Accord Builder. User Guide

Ovation Machinery Health Monitor for the Power Industry

Model FP-100 General Specification

Protection Cards for AMS 6500 Classic Systems

Type 9160 / Transmitter supply unit / Isolating repeater. Safety manual

Saving Energy and Reducing Costs Through Better Use of Building Automation Systems

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

LCD Meter for Model 3051 Pressure Transmitters English Rev. AA

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) Process Device Manager (PDM) Device Type Manager(DTM) M10

Smart Wireless THUM Adapter

Advanced Fieldbus Diagnostics, Without Fieldbus

Advanced Pattern Recognition Technology Applied to T&D Equipment. August 2010

Special documentation Proline Prowirl 200

Fisher FIELDVUE DVC6200 HW2 Management of Change Guide

Oldham OLCT 200 Revision 1

Use of device diagnostics.

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) IFC090 KROHNE 11/2000

DELTA CONTROLS CORPORATION

OPTICHECK Technical Datasheet

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

2014 UK & Ireland Training Offerings

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

WHAT NEW TECHNOLOGIES AND DATA CAN DO FOR THE WATER INDUSTRY

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

Device Management Protocols Protocoles de gestion des appareils Gerätezugangsprotokolle. The HART Protocol

Warning 101 Invalid heater power for front detector, inlet, and aux 1 Warning 102 Invalid heater power for back detector, inlet, and aux 2

375 Field Communicator

Session - III Control Philosophy Change with FF. Jonas Berge Emerson Process Management

FT2 View Instruction Manual

HART. Actuator Control. Redefining Flow Control

1.6 Configuring Intelligent Devices

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Introduction. Upon completion of Basics of PLCs you should be able to: Identify the major components of a PLC and describe their functions

Distributed Power System SB3000 Synchronous Rectifier &RQILJXUDWLRQDQG3URJUDPPLQJ

Explosion-Proof Gauge Pressure Transmitter

Calibrating HART Transmitters. HCF_LIT-054, Revision 1.1

OPTICHECK Technical Datasheet

FT2 View Instruction Manual

Installing ValveLink Software. ValveLink Solo ValveLink SNAP ON ValveLink DTM ValveLink PLUG IN for PRM. Installation Guide D102800X012

HART Communicator. MAN 4275A00 PN: English July 2000

Ovation Controller Model OCR1100

Operating Manual. Guardian Series Safety Compliant Melt Pressure Transducer

Rosemount 248 Wireless Temperature Transmitter

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Advanced Test Equipment Rentals ATEC (2832)

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

S900 Remote I/O System Intrinsic safety in the field ABB

Instruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter

TM Process Instruments. Vivace Process Instruments is a company that provides products and services for industrial automation and control.

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

VERTIV SERVICE CAPABILITY

IFC 100 Supplementary instructions

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

We put the now in knowledge Today s solutions built on a century of innovation and expertise

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

FLXA202/FLXA21 2-Wire Analyzer HART Communication. Functions Available via HART Communication...4. DD Menu Structure for ISC Meter Functions

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

Design and delivery of a Control System for an Aluminum Smelter. Skúli Björn Jónsson

AMS 6500 ATG. Overview. API 670 compliant TSI protection system

ARC VIEW. Honeywell s New PLC Brings Digital Transformation to the ControlEdge. Keywords. Summary. The Edge and IIoT.

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

Transcription:

Rosemount Transmitter Diagnostics Reduce Maintenance Costs ROSEMOUNT TRANSMITTER DIAGNOSTICS... Reduce the Necessity of Trips to the Field by 85% Eliminate Ghost Chasing by Checking Transmitter Diagnostics On-line save $100/device Commissioning Instruments Loop Checks Labor Savings of 88% 75% Reduction in Loop Test Time on Start-up FEATURES AND BENEFITS Monitoring field instruments allows predictive and proactive maintenance Operator can check transmitter status before scheduling maintenance trip to field Provides the ability to configure, troubleshoot, and test connected devices and maintain a database of these devices Device specific diagnostics show health of device or sensor As Found/As Left audit trail meets ISO and OSHA compliance requirements www.rosemount.com

CONTROLLING MAINTENANCE COSTS In today s process control industries, maintenance costs are increasing and having a direct impact on profitability. Controlling these costs is now a key strategy for most process plants. For most plants, where to invest in maintenance is still a major issue. The four most well known maintenance strategies are reactive, preventative, predictive, and proactive. Unfortunately, over 50% of the current maintenance practices are reactive. Maintenance is scheduled when the equipment has reached complete failure. This correlates to expensive, unscheduled downtime and costly equipment repairs. The second most typical maintenance practice is preventative. This practice usually involves a time-based system for scheduling maintenance. An example of preventative maintenance for process instrumentation is a calibration check every eight months on critical instruments. While this may uncover some possible problems, most of the checks are unnecessary since the instrumentation is healthy. Today, management is beginning to recognize the importance of plant availability on profits. While preventative practices are still important, there is a growing need for predictive and proactive maintenance programs. 60 50 40 30 20 10 0 FIGURE 1. Plant Maintenance Strategies Reactive Preventive Predictive Proactive Source: CSI Industry Survey Current Practice Best in Class A predictive maintenance program includes the ability to look at the status of instrumentation on-line. By continuous monitoring of equipment condition, a plant operator can identify possible problems before complete failure occurs. Proactive maintenance is a new concept that allows you to determine the general time frame that an instrument will fail before it does. This concept is designed to minimize the risk of failure by eliminating the root cause. chart-chrt0001 FIGURE 2. Maintenance Failures by Equipment Type 4000 3650 3000 Failure Rate (10 6 Hours) Source: Oreda 2000 1000 0 Compressors Gas Turbines 2017 Pumps 1169 1100 Power Generating Systems Safety Systems 210 Heat Exchangers 36 31 13 Valves Transmitters chart-chrt0002 2

FIGURE 3. Transmitter Check Results 50 40 35% 63% of Transmitter Field Trips Resulted In No Problem Found 28% 30 20% 20 10 6% 6% 4% 0 Routine Check No Problem Calibration Shift Zero Off Plugged Lines Failed Instrument chart-chrt0003 Monitoring Devices Choosing what to monitor on-line can be a difficult decision. In most process plants, rotating equipment tends to be the least reliable component. Investing in on-line systems to monitor this type of equipment is therefore becoming more popular. On the other hand, the transmitters are the most reliable device in the plant. Should you also monitor them? While transmitter instrumentation tends to be the most reliable, they are also the most frequently checked process equipment. Since transmitters are typically the primary sensor reading into a control system, they are the first suspect when a problem occurs. However, most of these transmitter checks are unnecessary. In one large chemical plant, 63% of the trips to the field to check on a transmitter resulted in no problem found (see Figure 3). At an average cost of $300 per trip, a considerable savings can be achieved if the health of the instrument is known before making the field call. Monitoring of field instrumentation can therefore be very cost effective. Through the use of digital communications, on-line monitoring can be achieved easily and directed to where the information is most needed. FIGURE 4. PlantWeb Provides both Process Control and Asset Management Solutions ams-ams0005 3

Predictive and Proactive Maintenance Through the use of Asset Management Solutions (AMS) from Fisher-Rosemount, predictive and proactive maintenance become a reality. Intelligent field devices utilizing the HART digital communication standard can easily be integrated into an Asset Management Solution while still providing the needed control signals. Built-In Diagnostics Each Rosemount intelligent device provides extensive diagnostics to indicate the health of the instrument, as well as some key predictive information. These diagnostics are available on-line through the use of the HART multipliers and/or pass through with Fisher-Rosemount control systems, connected to AMS. Using AMS, maintenance personnel can determine which instrument is causing a process upset before taking a trip to the field. Each device in the suspect control loop can independently be checked by AMS for diagnostic status. If a problem has occurred in the instrument, the corresponding status bit will be flagged. An alert monitor is also available to scan connected devices for anomalies. Should a fault occur in a scanned device, AMS will show an alert and indicate which instrument is in trouble. Many instruments also have built-in alarms that predict future problems. Preventing Failures Before They Occur In the process control industries, many instruments fail due to overheating. However, most transmitters from Rosemount include an internal temperature sensor that warns maintenance personnel when the temperature has exceeded specifications. AMS alerts the maintenance personnel of this condition, and they take actions to reduce the temperature prior to device failure, thereby saving the instrument and preventing costly downtime. Additional AMS Features In addition to on-going monitoring of instrumentation, AMS provides the ability to configure, troubleshoot, and test connected devices and maintain a database of these devices (see Figure 6). All of the installed, spare and new field devices that need to be configured, calibrated, commissioned, monitored, and reported on are managed through the powerful features of AMS. AMS also provides the capability to upload and download configuration information from the Model 275 HART Communicator. Full audit trail capabilities of each device is also recorded, including as found and as left calibration history. This critical information is often required for OSHA and ISO regulations. AMS is Available Today AMS communicates with all HART devices from Fisher-Rosemount. Currently over 3.5 million Rosemount HART devices are installed world-wide which can provide these valuable diagnostics. FIGURE 5. AMS On-Line Monitoring of Transmitter Health Status ams-ams0005 4

The savings of using an on-line AMS system quickly add up on an annual basis: TABLE 1. Start-up savings $150 /device Streamlined configuration 100 /device Streamlined calibration 50 /device Self-documenting Tools 130 /device Reduce No problem Found trips 60 /device Reduce unnecessary valve rebuilds 617 /device With AMS you can work with all Rosemount devices HART and FOUNDATION fieldbus. Adding AMS to your control system reduces your current maintenance costs, while at the same time enhance your process and protect your plant investment. For more information on how AMS can help your plant, contact your local Fisher-Rosemount representative. NOTE Pages 6 through 17 of this document identify the diagnostic information for each Rosemount device that is available through AMS. Fisher-Rosemount HART Devices that Communicate with AMS Pressure Temperature Flow Model 3051C Model 3144 Model 8800 Model 3051T Model 3244 Model 8712 Model 1151S Model 644 Model 8712C Model 2088 Model 3044 Model 8712U Model 2090 P Model 8732 Model 2090 F Model 8712H Model 9712 Model 9739 Model 9701 Model 3095FT Model 3095MV Probar Mass Probar Level Valves Analytical Model 3001 DVC 5000 Series Model 2061pH Model 3201HIU Oxymitter 4000 Model 2081C Model 3202HIU OPM 2000R Model 3081pH APEX Model 3081SG Model WC 3000 Model 3095 C Model 3081C Model 54pH FIGURE 6. Example AMS Database of Connected Devices ams-1011 5

MODEL 3051 TRANSMITTER DIAGNOSTICS FIGURE 7. AMS Critical Diagnostics Screen for the Model 3051 Pressure Transmitter Family ams-1001 AMS Diagnostics Available for the Model 3051 Pressure Transmitter Family Electronics Failure Sensor Failure Process Condition Configuration Warning D/A Not Updated No Pressure Updates Primary Variable Out of Limits Configuration Changed ROM Checksum Error No Temperature Updates Non-Primary Variable Out of Limits Primary Variable Analog Output Fixed CPU EEPROM Write Fail Sensor Board EEPROM Write Fail Primary Variable Analog Output Saturated Temperature Coefficient Checksum Sensor Board Not Initialized Error Software Error 3 Software Error 2 Software Error 1 CPU Board Not Initialized Incompatible CPU Board and Module 6

MODEL 1151 TRANSMITTER DIAGNOSTICS FIGURE 8. AMS Critical Diagnostics Screen for the Model 1151S Pressure Transmitter Family ams-1002 AMS Diagnostics Available for the Model 1151S Pressure Transmitter Family Electronics Failure Process Condition Configuration Warning D/A Not Calibrated Primary Variable Out of Limits Field Device Not Installed D/A Zero Not Calibrated Primary Variable Analog Module Range/Type Not Entered Output Saturated D/A Gain Not Calibrated Module Not Characterized Transmitter Fault Transmitter in Characterize Mode ROM Checksum Error Primary Variable Analog Output Fixed (1) RAM Selftest Error Configuration Changed (1) EEPROM Checksum Error Final Assembly Number Not Entered (2) Pressure Update Failure (1) Only available for Model 1151S Versions 5. (2) Only available for Model 1151S Version 1, 2, 3, or 4. 7

MODEL 2088 TRANSMITTER DIAGNOSTICS FIGURE 9. AMS Critical Diagnostics Screen for the Model 2088 Pressure Transmitter Family ams-1013 AMS Diagnostics Available for the Model 2088 Pressure Transmitter Family Electronics Failure Sensor Failure Process Condition Configuration Warning D/A Not Updated No Pressure Updates Primary Variable Out of Limits Configuration Changed ROM Checksum Error No Temperature Updates Non-Primary Variable Out of Limits Primary Variable Analog Output Fixed CPU EEPROM Write Fail Module EEPROM Write Fail Primary Variable Analog Output Local Buttons Operator Error Saturated 4k Micro EEPROM Error-User Sensor Board Not Initialized 4k Micro EEPROM Error-Factory 1k Sensor EEPROM Error-User Incompatible CPU Board Module 4k Sensor EEPROM Error-User Temperature Coefficients 1k Sensor EEPROM Error-Factory Checksum Error 4k Sensor EEPROM Error-Factory 4k Micro EEPROM Error-User No Out 1k Sensor EEPROM Error-User No Out 8

MODEL 3095 MV TRANSMITTER DIAGNOSTICS FIGURE 10. AMS Critical Diagnostics Screen for the Model 3095 MV Mass Flow Transmitter ams-1003 AMS Diagnostics Available for the Model 3095 MV Mass Flow Transmitter Electronics Failure Sensor Failure Process Condition Configuration Warning HART Persistent Data Failure Sensor Board EEPROM Burn Sensor Temp is Above Upper Internal Limit Reverse Flow Detected Failure HART Persistent Data Rolled Back Sensor Board EEPROM Not Initialized Sensor Temp is Below Lower Internal Limit Primary Variable Analog Output Fixed Sensor App Persistent Data Failure Sensor Hardware is Incompatible Process Temp is Above Upper Internal Limit Configuration Changed Sensor App Persistent Data Rolled Back No Response From Sensor Micro Process Temp is Below Lower Internal Limit Cold Start Analog App Persistent Data Failure Sensor Module Not Updating Static Press is Above Upper Internal Limit Analog App Persistent Data Rolled Back Temperature Sensor is Static Press is Below Lower Internal Limit Disconnected Output Board EEPROM Burn Failed Static Press Sensor is Shorted Diff Press is Above Upper Internal Limit Output Board EEPROM Not Initialized Static Press Sensor is Open Diff Press is Below Lower Internal Limit Self Test Failed Flow - PT is Above Upper Operating Limit Software Detected Error Flow - PT is Below Lower Operating Limit Reserved Bit Set - Status Byte 3, Bit 5 Flow - SP is above Upper Operating Limit Reserved Bit Set - Status Byte 3, Bit 4 Flow - SP is Below Lower Operating Limit Application #2 Persistent Data Failure Primary Variable Out of Limits Application #2 Persistent Data Rolled Back Non-Primary Variable Out of Limits Flow Persistent Data Failure Primary Variable Analog Output Saturated Flow Persistent Data Rolled Back Flow Configuration Error Flow Calculation Math Error Flow is Above Upper Internal Limit Field Device Malfunction 9

MODEL 3095 MV LEVEL CONTROLLER FIGURE 11. AMS Critical Diagnostics Screen for the Model 3095 MV Level Controller ams-1012 AMS Diagnostics Available for the Model 3095 MV Level Controller Electronics Failure Sensor Failure Process Condition Configuration Warning Field Device Malfunction Sensor Board EEPROM Static Region CRC Failure Primary Variable Out of Limits Primary Variable Analog Output Fixed Control Persistent Data Rolled Back Sensor Board EEPROM Dynamic Region CRC Failure Non-Primary Variable Out of Limits Cold Start Control Persistent Data Failure Static Press Sensor is Open Primary Variable Analog Output Saturated LOI Persistent Data Rolled Back Static Press Sensor is Shorted More Status Available LOI Persistent Data Failure Temperature Sensor is Disconnected Diff Press is Below Lower Internal Limit Level Persistent Data Rolled Back Sensor Module Not Updating Diff Press is Above Upper Internal Limit Level Persistent Data Failure No Response From Sensor Microprocessor Static Press is Below Lower Internal Limit Auto-Tuner Persistent Data Rolled Back Sensor Hardware is Incompatible Static Press is Above Upper Internal Limit Auto-Tuner Persistent Data Failure Sensor Board EEPROM Not Initialized Process Temp is Below Lower Internal Limit Bad Level Status Sensor Board EEPROM Burn Failure Process Temp is Above Upper Internal Limit Self Test Failed Sensor Temp is Below Lower Internal Limit Output Board ROM CRC Failure Output Board RAM CRC Failure Reserved-Status Byte 4, Bit 6 Factory E2 Error Output Board EEPROM Not Initialized Output Board EEPROM Burn Failed Analog App Persistent Data Rolled Back Analog App Persistent Data Failure Sensor App Persistent Data Rolled Back Sensor App Persistent Data Failure HART Persistent Data Rolled Back HART Persistent Data Failure Sensor Temp is Above Upper Internal Limit 10

MODEL 3244 TEMPERATURE TRANSMITTER FIGURE 12. AMS Critical Diagnostics Screen for the Model 3244 Temperature Transmitter ams-1004 AMS Diagnostics Available for the Model 3244 Temperature Transmitter Family Electronics Failure Sensor Failure Process Condition Configuration Warning EEPROM Invalid Configuration Sensor Failure Primary Variable Out of limits Excess Correction RAM Failure Housing Failure Non-Primary Variable Out of Limits Operator Error ROM Checksum Failure Sensor 1 Failed Primary Variable Analog Output Saturated Configuration Changed EEPROM Write Failure Sensor 1 Shorted Sensor 1 Out of Range Primary Variable Analog Output Fixed EEPROM Special Sensor Checksum Error Sensor 2 Failure Sensor 2 Out of Range EEPROM Factory Area Checksum Failure Sensor 2 Shorted Hot Backup Active EEPROM User Area Checksum Failure EEPROM Checksum Failure ASIC Receive Error ASIC Transmission Error ASIC Conversion Error ASCI Reference Error ASIC Interrupt Lost ASIC Interrupt Pulse Invalid ASIC Calibration Error ASIC General Failure Electronics Failure Housing Failure Housing PRT Failed No Trim Update 11

MODEL 3144 TEMPERATURE TRANSMITTER FIGURE 13. AMS Critical Diagnostics Screen for the Model 3144 Temperature Transmitter ams-1005 AMS Diagnostics Available for the Model 3144 Temperature Transmitter Family Electronics Failure Sensor Failure Process Condition Configuration Warning EEPROM Invalid Configuration Sensor Failure Sensor 1 Out of Range Primary Variable Analog Output Fixed RAM Failure Housing Failure PRT Out of Range Excess Correction ROM Checksum Failure Sensor 1 Failed Primary Variable Out of Limits Configuration Changed EEPROM Write Failure Sensor 1 Shorted Non-Primary variable Out of Limits EEPROM Special Sensor Checksum Error Primary Variable Analog Output Saturated EEPROM Factory Area Checksum Failure EEPROM User Area Checksum Failure EEPROM Checksum Failure ASIC Receive Error ASIC Transmission Error ASIC Conversion Error ASCI Reference Error ASIC Interrupt Lost ASIC Interrupt Pulse Invalid ASIC Calibration Error ASIC General Failure No Trim Update Electronics Failure Housing Failure Housing PRT Failed 12

MODEL 644 TEMPERATURE TRANSMITTER FIGURE 14. AMS Critical Diagnostics Screen for the Model 644 Temperature Transmitter ams-1006 AMS Diagnostics Available for the Model 644 Temperature Transmitter Family Electronics Failure Sensor Failure Process Condition Configuration Warning EEPROM Invalid Configuration Sensor Failure Sensor 1 Out of Range Primary Variable analog Output Fixed RAM Failure Sensor 1 Failed PRT Out of Range Configuration Changed ROM Checksum Failure Sensor 1 Shorted Primary Variable Out of Limits Excess Correction EEPROM Factory Area Checksum Failure Primary Variable Analog Output Saturated Operator Error EEPROM User Area Checksum Failure EEPROM Checksum Failure ASIC Receive Error ASIC Transmission Error ASIC Conversion Error ASCI Reference Error ASIC Interrupt Lost ASIC Interrupt Pulse Invalid ASIC Calibration Error ASIC General Failure No Trim Update Electronics Failure Housing Failure Housing PRT Failed 13

MODEL 3044 TEMPERATURE TRANSMITTER FIGURE 15. AMS Overview Diagnostics Screen for the Model 3044 Temperature Transmitter ams-1007 AMS Diagnostics Available for the Model 3044 Temperature Transmitter Family Electronics Failure Sensor Failure Process Condition Configuration Warning Invalid EEPROM Configuration Bad Upper and/or Lower Range Values for Sensor Primary Variable Out of Limits Fatal Configuration Error RAM Failure Sensor Failure Non-Primary Variable Out of Limits Configuration Changed ROM Checksum Error Primary Variable Analog Output Saturated Primary Variable Analog Output Fixed Sensor Board EEPROM Checksum Error Operator Error Micro Board EEPROM Checksum Error User Trim Error: Excess Error ASIC Start/Stop Bit Error ASIC Parity Error ASIC Control World Mismatch Improper Nominal ASIC Count Loss of ASIC Interrupt ASIC Interrupt Too Wide Generalized ASIC Failure No Trim Update Electronics Module Failure (sensor board) Electronics Module Failure (micro board) 14

MODEL 8712C, 8712H, AND 8712U MAGNETIC FLOWMETERS FIGURE 16. AMS Critical Diagnostics Screen for the Model 8712 Magnetic Flowmeters ams-1008 AMS Diagnostics Available for the Model 8712C, 8712H and 8712U Magnetic Flowmeters Electronics Failure Sensor Failure Process Condition Configuration Warning Electronics Failure Coil Drive Current is Zero Positive Zero Return Activated Primary Variable Analog Output Fixed EEPROM Checksum Error Coil Drive Fault Reverse Flow Configuration Changed RAM Checksum Error Electrodes Open Circuit Sensor Out of Range Semi Custom or Interrupt Error Automatic Zero Failure Empty Pipe Detected Pulse Output Feedback Error D/A Output Out of Range Digital Trim Fail Frequency Output 1 Pulse Output Range Down Error Update Missed Output at Alarm Level Excess Calibration Correction, Zero Too Low Excess Calibration Correction, Zero Too High Excess Calibration Correction, Gain Too Low Excess Calibration Correction, Gain Too High Calibration Attempt Without Calibrator Excess Automatic Zero Correction, Zero Too Low Excess Automatic Zero Correction, Zero Too High Automatic Zero Attempt With Nonzero Flow Reverse Flow Rate Detected Frequency Output 1 Pulse Output out of Range Positive Zero Return Output Active Primary Variable Out of Limits Non-Primary Variable Out of Limits Primary Variable Analog Output Saturated 15

MODEL 8732 MAGNETIC FLOWMETER FIGURE 17. AMS Critical Diagnostics Screen for the Model 8732 Magnetic Flowmeter ams-1009 AMS Diagnostics Available for the Model 8732 Magnetic Flowmeter Electronics Failure Sensor Failure Process Condition Configuration Warning Electronics Failure Coil Drive Open Circuit Positive Zero Return Activated Primary Variable Analog Output Fixed Digital Trim Fail Electrodes Open Circuit Reverse Flow Configuration Changed EEPROM Checksum Error Automatic Zero Failure Sensor Out of Range RAM Checksum Error Coil Drive Current is Zero Empty Pipe Detected Semi Custom or Interrupt Error D/A Output Out of Range Pulse Output Feedback Error Frequency Output 1 pulse Output Range Down Error Update Missed Output at Alarm Level Excess Calibration Correction, Zero Too Low Excess Calibration Correction, Zero Too High Excess Calibration Correction, Gain Too Low Excess Calibration Correction, Gain Too High Calibration Attempt Without Calibrator Excess Automatic Zero Correction, Zero Too Low Excess Automatic Zero Correction, Zero Too High Automatic Zero Attempt With Nonzero Flow Reverse Flow Rate Detected Frequency Output 1 Pulse Output Out of Range Positive Zero Return Output Active Primary Variable Out of Limits Non-primary Variable Out of Limits Primary Variable Analog Output Saturated 16

MODEL 8800 VORTEX FLOWMETER FIGURE 18. AMS Critical Diagnostics Screen for the Model 8800 Vortex Flowmeter ams-1010 AMS Diagnostics Available for the Model 8800 Vortex Flowmeter Electronics Failure Process Condition Configuration Warning Electronics Failure Trigger Level Overrange Parameters Not Configured Software Detected Error Low Pass Filt Overrange Update Missed Coprocessor Error Low Flow Cut Overrange Primary Variable Analog Output Fixed Digital Filter Error Ambient Temp Overrange Configuration Changed ASIC Interrupt Error Primary Variable Out of Limits RAM Test Error Non-primary Variable Out of Limits EEPROM Checksum Error Primary Variable Analog Output Saturated ROM Checksum Error Factory EEPROM Config Error 17

Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. All other marks are the property of their respective owners. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001 www.rosemount.com 00816-0100-4745K 2002 Rosemount Inc. All rights reserved.