Advanced Test Equipment Rentals ATEC (2832) 375 Field Communicator. 375 Field Communicator. Product Data Sheet

Similar documents
375 Field Communicator

375 Field Communicator

375 Field Communicator

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

475 Field Communicator

FREQUENTLY ASKED QUESTIONS

475 Field Communicator

475 Field Communicator

475 Field Communicator

475 Field Communicator

Communicator to a HART device, the tag and model number of the connected device is automatically displayed on the top line of the LCD screen!

HART Communicator. Emerson Process Management Catalog

AMS Trex Device Communicator

AMS Trex Device Communicator

MC Toolkit (Rugged & Intrinsically Safe models)

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Advanced, Cost-effective, and Reliable HART Communication Products

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

USER INTERFACE REVISIONS

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

Juniper Systems, Inc West 1700 North Logan, Utah, TEL WEB

3500 Series Flat Panel Industrial PCs

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

Dolphin TM 6500 Mobile Computer. Quick Start Guide

Online Interfaces and Optional Features

M-series MQ Controller

DeltaV SD Plus Controller

S-series Horizontal Carriers

M-series MX Controller

EZCT-2KA. current transformer test set

Quadpad i MOBILITYMEETSDURABILITY

ONLINE LICENSING PROCEDURE

M-series Intrinsically Safe I/O

Quick Start Installation Guide

C100 Portable Multifunction

Advanced, Cost-effective, and Reliable HART Communication Products

SIDEPAK AM510 Personal Monitor

Thermal cameras. Detect hot spots before they cause you trouble

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

ARP992/ ARP992-B User Reference Manual

Exposure Monitoring HEALTH AND SAFETY

ARP 945 User Reference Manual

CALIBRATORS. BetaGauge II INTRINSICALLY SAFE MODEL AVAILABLE

QuickSpecs. Overview. Compaq ipaq Pocket PC H3600 Series. At A Glance. Easy expansion and customization through Compaq Expansion Pack System

DeltaV Bulk Power Supplies

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

TEST AND MEASUREMENT SRM 200 SRM 200/EFM 51 STARTERKIT

QuickSpecs. HP TFT7600 Rackmount Keyboard and Monitor (TFT7600 RKM) Overview

Dolphin TM 6110 Mobile Computer. Quick Start Guide

Andover Continuum. Power Supplies with or without UPS

Models HP Z VR Backpack G1 Dock

S-series Mass Connection Solutions

Advanced Test Equipment Rentals ATEC (2832)

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

DeltaV M-series I/O Subsystem Horizontal Carriers

Page/Talk Industrial Desk Sets

S-series DeviceNet Interface Card

MiniVox. Owner s Manual. Troubleshooting Guide. Having trouble with the sound system? Having trouble with the wireless system? (model PB-25W only)

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

I/A Series Hardware Mobile Workstation Indoor Unit

QuickSpecs. Front View. HP L5015tm Touch Monitor. Overview. 1. Main menu 2. Brightness menu 3. Contrast submenu 4. Auto Adjust 5.

QuickSpecs. Overview. HP L inch Retail Monitor. HP L inch Retail Monitor (head only)

QuickSpecs. HP Z inch 4K UHD Display. Technical Specifications. Front. 1. Power LED

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI.

S-series Horizontal Carriers

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

DeltaV Bulk Power Supplies

Fluke Ti30 Thermal Imager. Provided by Everything needed for everyday imaging. Complete imaging solution. Lowest cost of ownership

DevCom2000. Smart Device Communicator

Ovation Controller Model OCR1100

ARX 308 User Reference Manual

Professional and Versatile 24" LED Monitor

M-series MQ Controller

S-series Foundation Fieldbus I/O

CSI 9330 Vibration Transmitter

Roxar SandLog High Accuracy Sand/Erosion Monitoring

PIECAL CALIBRATORS. Milliamp Thermocouple RTD Voltage Frequency.

ARP 970 User Reference Manual

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

Multifunction Calibrator

-Direct.com FG-3000 Digital Force Gauge Operation Manual

BF ENTRON LTD. Monitoring equipment. Weld Analyser WA2

Fluke 729 Automatic Pressure Calibrator

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TAC I/NETTM 1284, 1280, Security Control Unit

LT30 GETTING STARTED GUIDE GPS/GIS HANDHELD CONTROLLER

4110 HART Level Encoder

QuickSpecs. Models. Introduction. HP Z VR Backpack G1 Workstation Accessories. Overview

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

UHD6510 UHD7510 UHD K Ultra High Definition Interactive Flat Panel Displays

Fluke Ti30 Thermal Imager

power quality Models 8230 & 8220

Compact yet Solid, SPP-R200

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Product Data Sheet D351019X012/00813-0100-4276 Bulletin 62.1: Communicator October 2004 Universal HART and Foundation TM fieldbus User upgradeable Intrinsically safe Rugged and reliable Interfaces with AMS Suite: Intelligent Device Manager The is designed to support all HART and all Foundation fieldbus devices from all vendors. Introduction The is the new standard in handheld communicators. Built on over ten years of experience with the 275 HART Communicator, user requirements drove the features of this next generation communicator. a portable intrinsically safe communicator that supports all their fieldbus devices. The result is the universal, user upgradeable, intrinsically safe, rugged and reliable. HART users worldwide told us how to make a better communicator. Fieldbus users said they wanted www.fieldcommunicator.com

We made sure that the weight was evenly distributed for comfortable one-handed operation in the field. It is loaded! The has a processor that is 20 times faster than the 275. It features 32MB of application memory, 64 times more than the 275 HART Communicator. The Configuration Expansion Module holds hundreds of device configurations, and it is externally accessible. Enhancements in the battery pack allow a full recharge in 2 hours, 8 times faster than the 275 HART Communicator. Easy Upgrade keeps your communicator current. A fold-away stand provides the correct viewing angle on the bench, and flips up to a locked position for secure hanging in the plant. Product Description Building on the experience with the proven 275 HART Communicator, the includes enhancements designed to simplify your work in the field. We designed the 375 Field Communicator user interface around the 275, leveraging the navigation features users told us they liked. Then we added powerful features including a much larger touch screen, HART Revision 6 support, and the ability to upgrade your onsite using the Internet. See the difference. The runs on Windows CE, a robust, real-time, operating system. The display is 70% larger than that of the 275 HART Communicator and uses transflective technology, making it easy to read in both bright sunlight and in normal lighting. To make sure we covered all conditions, we added a multi-level backlight, allowing the display to be viewed in those areas of your plant with dim light. The touch sensitive display and large physical navigation buttons provide for efficient use both on the bench and in the field. If that s not enough to get your attention, the 375 Field Communicator is also user upgradeable via the Internet. This means it is no longer necessary to send your communicator anywhere to have new device drivers added. Page 2

Designed not only for use on the bench, the enables you to do those tasks that just have to be done in the field. Universal HART and Foundation fieldbus The is designed to support all HART and Foundation fieldbus devices. If you are familiar with the 275 HART Communicator, used in thousands of plants worldwide for more than ten years, you will appreciate universal HART support in a single intrinsically safe handheld communicator. The can also be used to configure all the Foundation fieldbus devices in your plant. Use it to perform diagnostics for effective start-up and troubleshooting of Foundation fieldbus segments. Create a quality segment by diagnosing the network DC voltage and average noise. Detect power supply problems by monitoring low frequency noise on a segment. Locate incorrect terminations and faulty devices by diagnosing the communications signal level. No longer do you need to drag a laptop computer out into the plant to communicate with your Foundation fieldbus devices. With over 600 different HART and Foundation fieldbus devices from more than 100 different vendors, having a single field communicator that works with everything is a big help. So, grab the 375 Field Communicator and go! Page 3

Easy Upgrade allows communication between the and a PC using IrDA. The IrDA port enables transfer of configuration data between the 375 and AMS Device Manager as well as upgrading of new Device Descriptions and functionality. User upgradeable New HART and Foundation fieldbus devices, as well as functional updates to existing devices are introduced continually by device vendors. Keeping up-to-date with the required Device Description drivers for all the devices in your plant can be a real challenge. Now, with the Easy Upgrade option, keeping your communicator updated with the most current Device Descriptions (DD s) is easy. As new HART and Foundation fieldbus DD s become available, download them from the Internet and upgrade your 375 Field Communicator. In addition, as functional enhancements to the 375 HART and Foundation fieldbus applications become available, download software updates from the Internet and upgrade your. No longer is it necessary to send your communicator to a service center to have new DD s or software updates added. No longer is it necessary to be without your communicator while you wait for upgrades. Easy Upgrade lets you update your own. On your site, within your control, when it s convenient for you. Page 4

Intrinsically Safe. The meets the Intrinsic Safety requirements of the listed regulatory agencies and standards. All of the available Hazardous Locations approvals are provided in a single model option (see Ordering Information). CENELEC/ATEX Factory Mutual (FM) Canadian Standards Association (CSA) FISCO Even the battery pack is approved for installation in hazardous areas. The is designed for use in areas where laptops shouldn t go. Rugged and Reliable. It s called Field Communicator for a reason. Some tasks just have to be performed at the device. The is designed for tough use in your plant or mill. Its large keys and physical navigation buttons allow for onehanded operation, even with your work gloves on. The rugged display is designed to take the knocks and shocks from normal use in the plant. As for reliable, when was the last time you had to send your 275 HART Communicator in for repair? That s exactly the kind of reliability we ve built into the 375. The 375 Field Communicator is designed, manufactured and tested to specifications that are even more demanding. The 375 Field Communicator is designed to go wherever you have to go to get the job done. Specifications Processor and Memory Specifications Microprocessor 80 MHz Hitachi SH3 Memory Internal Flash 32 MB System Card 128 MB or higher secure digital card RAM 32 MB Expansion Module 32 MB or higher secure digital card PHYSICAL Specifications Weight Approximately 2 lb. (0.9kg) with battery Display 1/4 VGA (240 by 320 pixels) monochrome 3.8 (9.6 cm) transflective display with touch screen Anti-glare coated Keypad 25 keys including 4 action keys, 12 alphanumeric keys, 4 programmable function keys, on/off, and 4 cursor-control (arrow) keys; membrane design with tactile feedback POWER SUPPLY Specifications Battery Pack Rechargeable NiMH batteries Battery Operating Time Up to ten hours depending on usage Battery Charger Options Input voltage 85-240 VAC, 50/60 Hz Cables included with U.S., European and U.K. plugsonnection CONNECTION Specifications Battery Charger Mini DIN 4-pin jack HART and Fieldbus Three 4mm banana plugs (one common to HART and Foundation fieldbus) IrDA Port IrDA (Infrared Data Access) port supporting up to 115 Kbps ±15 degrees recommended maximum angle from center line Approximately 12 (30 cm) recommended maximum distance ENVIRONMENTAL Specifications Usage -10 C (14 F ) to +50 C (122 F ) 0% to 95% RH (non-condensing) for 0 C (32 F ) to +50 C (122 F ) Charge 0 C (32 F ) to +40 C (104 F ) Storage -20 C (-4 F ) to +55 C (131 F ) with batteries Storage Without Batteries -20 C (-4 F ) to +60 C (140 F ) Enclosure Rating IP51 (from front) Shock Tested to survive a 1-meter drop test onto concrete EASY UPGRADE REQUIREMENTS Usage PC with internet access CD Rom drive IrDA port (or adapter) Windows 2000 or XP Page 5

Interfaces with AMS Suite: Intelligent Device Manager. The is fully compatible with AMS Device Manager, the industry standard for asset management software. In fact, Control Magazine readers selected AMS as the #1 Calibration Software package for 3 years in a row. AMS Device Manager allows you to configure, streamline calibration, document and troubleshoot HART and Foundation fieldbus devices. AMS Device Manager uses the intelligence from field devices to create a predictive maintenance environment. Transfer device configuration data via the infrared port on the and AMS Device Manager on your PC.Carry your out to the field to configure or update one or many devices. Save device configurations in your 375 Field Communicator for safe storage or transfer to AMS Device Manager. The optional Configuration Expansion Module stores hundreds of device configurations safely in your. The Configuration Expansion Module safely stores hundreds of device configurations. Together, the 375 Field Communicator and AMS Device Manager enable you to more efficiently manage all of your devices, the assets that are the foundation of your process. Page 6

Spare Parts List Description Part Number Ruggedized 250 Ohm Load Resistor 00275-0096-0001 Rechargeable NiMH Battery Pack with Accessory Case 00375-0002-0011 Power Supply/Charger (90-240 VAC, 50/60Hz, US/UK/EU connection types included) 00375-0003-0011 Lead Set with connectors 00375-0004-0001 Mounting Straps 00375-0005-0002 Carrying Case (with straps) 00375-0005-0003 Accessory Case (clips to Carrying Case) 00375-0005-0004 Stylus (pack of 5) 00375-0006-0001 IRDA to USB Adapter (1) 00375-0015-0002 Expansion Port Plug 00375-0031-0001 System Card - HART and FOUNDATION fieldbus 00375-0042-0002 System Card - HART with Easy Upgrade Option (2) 00375-0042-0003 System Card - HART and Foundation fieldbus with Easy Upgrade Option (2) 00375-0042-0004 Configuration Expansion Module 00375-0043-0001 Stand and Utility Plate 00375-0044-0001 Getting Started Guide 00375-0045-0001 User's Manual 00375-0047-0001 Resource CD (3) 00375-0049-0001 (1) For use with AMS Device Manager/375 Interface or 375 Easy Upgrade Programming Utility. (2) Includes unlimited upgrades to System Card for 3 year period. (3) Contains 375 Programming Utility and System Software/DD database. This CD is updated quarterly. Shipping Weight (varies with options) 71 lbs/3.2 kg (based on 375HR1EKLU) Page 7

October 2004 Ordering Information Model Product Description (1) Code Communication Protocol H HART F HART and Foundation fieldbus (2) Code Battery Type R Rechargeable NiMH Battery Pack Code Power Supply/Recharger 1 Power Supply/Recharger (90/240 VAC, 50/60Hz, US/UK/EU connection types included) 9 Not included Code Language E English (standard) Code Approval Certifications KL CENELEC/ATEX, FM, CSA Intrinsically Safe (includes FISCO as applicable) NA No Approval Code Easy Upgrade (4) U Easy Upgrade Option (includes unlimited upgrades to System Card for 3 year period) 9 Not Included Code Options Spare Battery Pack B Spare Rechargeable NiMH Battery Pack (5) Expansion Module C Configuration Expansion Module (6) Typical Model Number: 375 H R 1 E KL U (1) Base Model 375 includes Field Communicator Unit with Battery Pack, System Card, Leadset with Connectors, Carrying Case, Getting Started Guide, User s Manual, 375 Resource CD, Stylus and Straps. (2) Requires that the Easy Upgrade Option (CODE U) also be purchased. (3) This option should only be considered if the user already has a 375 Power Supply/Charger. Note: Only 375 Power Supply/Chargers may be used with the 375 Battery Pack. (4) The Easy Upgrade capability allows the user to add new System Application software and Device Descriptions (DD s) to the 375. To upgrade without this feature, the System Card must be sent a Service Center. (5) A fully charged battery pack is capable of delivering power for 8 hours of typical field use. If requirements exceed this specification, a second battery pack is recommended. (6) The 375 is capable of storing a total of 25 configurations. For increased storage capacity, use the Configuration Expansion Module which is capable of storing in excess of 500 configurations. Emerson Process Management Asset Optimization Division 12001 Technology Drive Eden Prairie, MN 55344 USA T 1(512) 832-3235 F 1(952) 828-3033 2004, Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. All rights reserved. AMS is a mark of one of the Emerson Process Management group of companies. The Emerson logo is a trademark and service mark of Emerson Electric Company. All other marks are the property of their respective owners. www.fieldcommunicator.com