DIGITAL SOUND LEVEL METER. Instruction Manual

Similar documents
Sound Level Pen Instruction Manual

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Torque Meter. Instruction Manual

Light Meter (Foot Candles)

4-Channel Thermometer

Datalogging Conductivity/ TDS Meter. Instruction Manual

Type K/J Thermometers

Pocket type SOUND LEVEL METER Model : SL-4030

Advanced Datalogging Sound Meter Instruction Manual

Vacuum Meter Instruction Manual

Light Meter with Bar Graph

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Wide Range Pressure Meter Instruction Manual

Mini Environmental Quality Meter

Bluetooth IR Pen. Instruction Manual

Advanced Datalogging Thermometer. Instruction Manual

Torque Meter. Instruction Manual

4-Channel Datalogging Thermometer

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Psychrometer/Anemometer. Instruction Manual

Anemometer/Thermometer

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Mini Environmental Quality Meter

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

AquaShock ph Meter K

Digital Sound Level Meter MODEL

Digital Sound Level Meter

Datalogging RH / Temperature Pen Instruction Manual

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Mini Environmental Quality Meter

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

Mini Environmental Quality Meter

WBGT SD Card Datalogger. Instruction Manual

RH/Temperature SD Card Datalogger. Instruction Manual

User's Guide. Digital Sound Level Meter. Model

Temperature Datalogger

Datalogging Hot Wire CFM Anemometer

Anemometer SD Card Datalogger. Instruction Manual

TestLink Software for Software Instruction Manual

Datalogging IAQ Meter Instruction Manual

Datalogging ph Meter

4 Channel Datalogging Thermometer. Instruction Manual

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC

Visible Light SD Card Datalogger

User's Manual Sound Level Alert Model SL130

Pro II. Sound Level Meter V-9992

POCKET DIGITAL REFRACTOMETERS ~

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

Digital Sound Level Meter

Digital Sound Level Meter

Integrating Sound Level Datalogger Model

WBGT SD Card Datalogger. Instruction Manual

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

DO Meter Kit. Instruction Manual

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD.

Personal Sound Level Meter

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

Thermal Imaging Camera 220 x Instruction Manual

Large Display Salinity & Conductivity Pens &

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

PH SD Card Datalogger. Instruction Manual

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

Digital Sound Level Meter with USB Model:

I/R Thermometer Gun 8:1

PM2.5 and PM10 Monitors , & Instruction Manual

Sound Level Meter SD Card real-time Datalogger

DIGITAL SOUND METER WITH JUMBO DISPLAY

User s Manual. Sound Level Meter. FSM 30Plus. Lo/Hi MAX HOLD S/F. S F db BAT. SOUND LEVEL: Lo=35~100dB Hi=65~130dB. 94dB

Datalogging Manometers 2PSI, 5PSI, 15PSI , ,

TES-1358 INSTRUCTION MANUAL

User's Manual. Digital Sound Level Meter. Model

CM-140. Instruction Manual SOUND LEVEL METER G A L A X Y A U D I O

AC/DC Current Probe Model SL206 USER MANUAL

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

USER S MANUAL. Data Logger SOUND LEVEL METER.

Datalogging Manometer

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

User s Manual. Model and Sound Level Calibrators

7032 Digital-Analog Multimeter

AC/DC Current Probe Model SL201

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

Instruction Manual Digital Sound Level Meter

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Telex Operating Instructions

Heavy Duty Vibration Meter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Digital Sound Level Meter

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

INSTRUCTION MANUAL REC FAST A/C

Model 3526-B Digi-Probe Multimeter

Manual SOUND LEVEL METER PCE-322 A

Transcription:

DIGITAL SOUND LEVEL METER 840029 Instruction Manual

CONTENTS I. Introduction... 3 II. Panel Description... 3 III. Operating Instructions A. Measuring Procedure... 4 B. Settings for General Applications... 4 C. Signal Output... 4 D. Calibration... 4-5 E. Precautions... 5 F. Battery Replacement... 5 IV. Specifications... 6 Frequency Weighting (A and C) Characteristics... 7 Response (Fast and Slow) Characteristics... 7 V. Warranty... 8-2 -

I. INTRODUCTION Perfect for testing for OSHA requirements, your new instrument meets IEC 61672 class 2 and ANSI S1.4 type 2 frequency and time weighting specifications, DIN 45633 and JIS 1502. It covers the 30 to 130 db in the "A" scale, and 35 to 130 db in the "C" scale, with an accuracy of ±1.5 db. This meter can be acoustically calibrated in compliance with OSHA, using Sper Scientific's Acoustical Calibrator 850016 (or equivalent). Features include a built-in calibration adjustment, Fast or Slow time weightings, Maximum Hold function, large display with a resolution of 0.1 db, low battery indicator, and AC or DC output. The instrument has a fold out tripod stand and comes with carrying case, instructions, calibration tool, and a 9V battery. II. PANEL DESCRIPTION Microphone Overload indicator Power selector Range selector Display Calibration Adjustment Weighting selector (A or C) Response selector (Slow/Fast/Max Hold) Signal Output terminal - 3 -

III. OPERATING INSTRUCTIONS A. MEASURING PROCEDURE Slide the POWER selector to the ON (AC) or ON (DC) position. Slide the WEIGHTING selector to the "A" or "C" position. The "A" frequency weighting simulates human ear response. During an environmental sound level measurement, select the "A" weighting. The "C" weighting approximates a flat response. Typically, "C" is used to check the noise of machinery where the target sound level is already known. (See Frequency Weighting Characteristics, page 7.) Slide the RESPONSE selector to the FAST or SLOW position. For general applications, select FAST, which simulates the human ear's response time. The SLOW setting is used to obtain an average of vibrating sound levels. Find the appropriate measuring range using the RANGE selector. If the OVERLOAD INDICATOR (a triangle shape) appears in the upper-left display, slide the RANGE selector to another setting. Point the microphone at the sound source, the sound level will be displayed in decibels (db). To power off the unit, slide the POWER selector to the OFF position. B. SETTINGS FOR GENERAL APPLICATIONS Set POWER selector to an ON position. Set RESPONSE selector to Fast. Set WEIGHTING to "A". Set RANGE selector to the appropriate range. C. SIGNAL OUTPUT The 3.5 mm diameter SIGNAL OUTPUT terminal may be used to connect the unit to an external output device, such as an analyzer, recorder, or controller. When connecting meter with an external output device, use the appropriate ON selection (AC or DC). D. CALIBRATION The meter's CALIBRATION ADJUSTMENT is located on the front panel. The meter has a built-in internal standard of 94 db/1 KHz. Use the following procedures to calibrate the instrument before operating for the first time, or when the meter has not been in use for awhile. Internal Calibration: - 4 -

Slide the POWER selector to an ON position. Slide the RANGE selector to the 50 to 100 db position. Slide the RESPONSE selector to FAST. Slide the WEIGHTING selector to CAL. Use the calibration screw driver to gently turn the CALIBRATION ADJUSTMENT until the display reads 94.0 db. External Calibration: Use Sper Scientific's Acoustical Calibrator 850016 (or equivalent) to calibrate the unit, including the microphone, in compliance with OSHA. Slide POWER selector to an ON position. Power on the acoustical calibrator and place the calibrator onto the Sound Level Meter's MICROPHONE. Slide the RANGE selector to the 50 to 100 db position. Slide the RESPONSE selector to FAST. Slide the WEIGHTING selector to "A". Use the calibration screw driver to gently turn the CALIBRATION ADJUSTMENT until the display reads 94.0. E. PRECAUTIONS Do not store or operate the unit in high temperatures or in a high humidity environment for long periods. Keep the microphone dry and avoid intense vibrations. Do not force the CALIBRATION ADJUSTMENT, doing so may damage the mechanism and void the warranty. F. BATTERY REPLACEMENT Replace the battery when "BAT" is displayed. Accurate measurements may be made for several hours after the low battery indicator appears. - 5 -

IV. SPECIFICATIONS Display Functions Measurement Range Resolution Accuracy Frequency Microphone Response (Fast/Slow) Internal Calibration Output Signal Output Terminal Operating Temp. Operating Humidity Power Supply Power Consumption Weight 3 1/2" digits, 3/4" LCD db ( A and C Frequency Weighting), Response (Fast, Slow), Max. Hold AC/DC Output 30-70 db, 60-100 db, and 90-130 db 40 db on each step, with overload indicator 0.1 db ± 1.5 db 31.5 Hz to 8,000 Hz 1/2" condenser microphone. Fast (F): t = 200 ms Slow (S): t = 500 ms Built-in internal calibration on front panel. Internal 94 db / 1 khz square wave generator AC: 0.5 Vrms corresponding to each range step. DC: 0.3 to 1.3 VDC, 10 mv per db. Output impedance is 600 ohm. 3.5 mm diameter phone jack 32 to 122 F (0 to 50 C) Less than 90% RH One 9V battery, heavy duty or alkaline type Approximately DC 6 ma 10 oz. Dimension 8 1/8" x 3 1/8" x 1 3/8" CE Compliant Included Accessories Optional Services & Accessories Yes Instruction Manual, 9V battery, calibration screw driver, and hard carrying case 840029C NIST Traceable Cert. of Calibration 840031 Acoustical Calibrator 840091 Wind Screen - 6 -

FREQUENCY WEIGHTING (A and C) CHARACTERISTICS Frequency db A db C Tolerance db 31.5-39.4-3.0 ± 5.0 40-34.6-2.0 ± 4.5 50-30.2-1.3 ± 4.0 63-26.2-0.8 ± 3.5 80-22.5-0.5 ± 3.0 100-19.1-0.3 ± 2.5 125-16.1-0.2 ± 2.0 160-13.4-0.1 ± 2.0 200-10.9 0 ± 2.0 250-8.6 0 ± 2.0 315-6.6 0 ± 2.0 400-4.8 0 ± 2.0 500-3.2 0 ± 2.0 630-1.9 0 ± 2.0 800-0.8 0 ± 2.0 1000 0 0 ± 2.0 1.25k 0.6 0 ± 2.0 ± 2.5 1.6k 1.0-0.1 ± 3.0-2.5 2k 1.2-0.2 ± 3.5-3.0 2.5k 1.3-0.3 ± 4.0-3.5 3.5k 1.2-0.5 ± 4.5 4k 1.0-0.8-4.0 5 0.5-1.3 ± 5.0-4.5 6.3-0.1-2.0 ± 5.5-5.0 8-1.1-3.0 ± 6.0-5.5 RESPONSE (Fast and Slow) CHARACTERISTICS Fast Reading is maximum value at 0.2 seconds Slow Reading is maximum value at 1.5 seconds - 7 -

FIVE YEAR WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, misuse, or abuse of the product. Opening the meter to expose it s electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 East Evans Rd. Suite #103 Scottsdale, Arizona 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com within 10 days of purchase. Rev. 8/17/2017-8 -