CINT W Triple Output Industrial Series

Similar documents
CINT W Single Output Industrial Series

ME to 30W Single Output External Power Medical Series. Features

LPS. ME20 20W Single Output External Power Medical Series. Features

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Safety Standards. Model Number: Unit Weight:

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

ORDERING INFORMATION SEE PAGE 6

60 Watt Medical (MWLT)

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Safety Standards. Model Number:

Universal Power Supplies

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Safety Standards. Model Number:

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Safety Standards. Model Number:

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

12-15VDC (12V±5%) 24-28VDC (24V±5%)

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Constant Voltage Mode

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Enclosed Power Supplies

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

275 Watt Medical Ultra low profile

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

CPCI - 6U - AC - 600W

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Safety Standards. Model Number:

C1U-W Tx Series

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

IEC/EN/UL60950 & CE certified, EN55032 Class B

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

CPCI - 6U - DC - 350W

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

C1U-W Tx Series AC/DC Front End Power Supply

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

-AC Input- Voltage/Current...AC V, 47-63Hz, 5.5A Max, 1 Phase. Fusing...AC 6.3A, 250V internal line fuse provided, non-user serviceable. Power F

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

HEC-100RTN-48QSCA Rev A1.0

PMT. Safety Standards. Model Number:

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

Output Voltage* (nom.)(adjustable)

PMT. Safety Standards. Model Number:

GE Data Sheet 2.0. CLP0448 Open Frame Power Supply Vac input; 48/54Vdc output; 450W Output Power. Features. Applications.

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

Universal input VAC <150mW No load power consumption

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Transcription:

CINT3 W Triple Output Features 2 x 4 x.3 Package Suitable for U Applications W w/air, 8W convection cooled Universal Input 9-264Vac Efficiency 87% typical Approved to CSA/EN/IEC/UL695-, 2 nd Edition Power Fail Signal Remote Sense 3 Year Warranty RoHS Compliant Description The CINT3 Series are industrial grade, high efficiency, triple output power supplies in a small 2 x 4 size. The CINT3 family is ideal for Industrial and ITE applications requiring multiple outputs and small footprint. Compliant to IEC695-2 nd edition, the CINT3 models feature outputs of 5/±2V, 5/±5V, 5/±24V, includes a Power Fail/DC OK signal, and meet Class B Conducted EMI. Model Selection Model Output Current** Ripple & Total OVP Number Volts* w/2lfm air Convection Noise*** Regulation Threshold CINT3A58K CINT3A78K CINT3A98K V 5V 4.A.A.% pk-pk ±2% 7.5V max. V2 2V 6.A 4.5A.% pk-pk ±3% 5%-35% V3-2V.A.A 2.% pk-pk ±% 5%-35% V 5V 4.A.A.% pk-pk ±2% 7.5V max. V2 5V 4.5A 3.5A.% pk-pk ±3% 5%-35% V3-5V.A.A 2.% pk-pk ±% 5%-35% V 5V 2.A 8.A.% pk-pk ±2% 7.5V max. V2 24V 4.A 3.A.% pk-pk ±3% 5%-35% V3-24V.A.A 2.% pk-pk ±% 5%-35% Notes: * 5V output is adjustable with +/-% range ** Total convection power is 8 Watts. *** Measured with noise probe directly across output terminals, and load terminated with.µf ceramic and µf low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. General Specifications AC Input -24Vac, ±%, 47-63Hz, 2 37Vdc Turn On Time Less than 2 sec. @5Vac (inversely proportional to input voltage and thermistor temperature) Input Current 5Vac:.5A, 23Vac:.75A Hold-up Time 6mS typical at W, 2Vac input www.slpower.com CINT3 REV.2, 9-SEP-4

CINT3 W Triple Output General Specifications (continued) Inrush Current 264Vac, cold start: will not exceed 45A Signals AC Power Fail, DC OK Input Fuses F, F2: 2.5A, 25Vac fuses provided on all models Overload Protection 5%-3% above rating for V2 & V3, %- 2% for V. Hiccup Mode Earth Leakage Current <29µA@264Vac, 6Hz, NC Short Circuit Protection Provided - no damage will occur if the output is shorted. Efficiency 87% typical at 23Vac Overvoltage Protection See models chart for trip range. Output Power W continuous with 2 lfm airflow, 8W convection cooled See chart for specific voltage model ratings. Switching Frequency PFC: 75kHz typical Transient Response 5µS typ. for return to within.5% of nominal, 5% load step. i/ t <.2A/µS. Max Volt Deviation = 3% Isolation Input-Output: 4Vac Input-Ground: 8Vac Output-Ground: 5Vac Ripple and Noise See models chart Operating Temperature - C to +7 C Output Voltage See models chart Temperature Derating Derate output power linearly above 5 C to 5% at 7 C Voltage Adjustability +/-% from nominal on 5V output Storage Temperature -4 C to +85 C Minimum Load Not required Altitude Operating: -5 to, ft. Non-operating: -5 to 4, ft. Total Regulation See models chart Relative Humidity 5% to 95%, non-condensing Vibration Operating:.3g²/Hz,.5grms overall, 3 axes, min/axis Non-Operating:.26g²/Hz, 5.grms overall, 3 axes, hr/axis Shock Operating: Half-sine, 2gpk, ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 4 gpk, ms, 3 axes, 6 shocks total Dimensions W: 2. x L: 4. x H:.3 Safety Standards EN/CSA/UL/IEC 695-, 2 nd Edition Weight 2g MTBF 245, hours, 25 C Ambient, Vac input Auxiliary Signals AC Power Fail: Remote Sense: During normal operation, stays HIGH. Signal goes LOW with at least 6mS warning before loss of DC output from AC failure. (5V output, optional) Will compensate for.5v drop min. Will operate without remote sense connected. Reverse connection protected. DC OK: Open collector logic signal goes and stays HIGH ms to 5mS after main output reaches regulation. Notes:. Specifications are for convection rating at factory settings at 5 Vac input, 25 C ambient unless otherwise stated. 2. For DC input an external DC safety rated fuse must be used. www.slpower.com CINT3 REV.2, 9-SEP-4 2

CINT3 W Triple Output EMI/EMC Compliance Conducted Emissions Radiated Emissions Static Discharge Immunity Radiated RF Immunity EFT/Burst Immunity Line Surge Immunity Conducted RF Immunity Power Frequency Magnetic Field Immunity Voltage Dip Immunity Line Harmonic Emissions Flicker Test EN55/22 Class B, FCC Part 5, Subpart B, Class B EN55/22 Class A; FCC Part 5, Subpart A, Class A EN6-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge EN6-4-3, 3V/m. Criteria A EN6-4-4, 2kV/5kHz, Criteria A EN6-4-5, kv differential, 2kV common-mode, Criteria A EN6-4-6, 3Vrms, Criteria A EN6-4-8, 3A/m, Criteria A EN6-4-, % Vin,.5cycle; 4% Vin, 5 cycles; 7% Vin, 25 cycles; Criteria A EN6-3-2, Class A, B, C, & D EN6-3-3, Complies (dmax<6%) Mechanical Drawing Notes:. All dimensions in inches (mm), tolerance is ±.2. 2. Mounting holes should be grounded for EMI purpose 3. Mounting J is safety ground connection 4. This power supply requires mounting on metal standoffs.2 (5 m) in height. www.slpower.com CINT3 REV.2, 9-SEP-4 3

CINT3 W Triple Output Connector Information Input Connector J PIN ) AC NEUTRAL PIN 2) EMPTY PIN 3) AC LINE Mating Connector: Molex 9-5-33 Pins= 8-52-72 AMP #6425-3 Pins= 3-6476- Ground J.87 FASTON TAB Mating Connector: Molex -92 DC Output Connector J2 PIN ) +V PIN 4) GND PIN 7) V2 PIN 2) +V PIN 5) GND PIN 8) V3 PIN 3) GND PIN 6) GND Mating Connector: Amp #6425-8 Pins=Amp #3-6476- Signal Connector J3 PIN ) Power Fail/DC OK PIN 2) GND PIN 3) +Remote Sense PIN 4) Remote Sense Mating Connector: Amp #37582-4 Pin= Amp #37589 Isolation Specifications Parameter Conditions/Description Min Nom Max Units Insulation Safety Rating Electric Strength Test Voltage Leakage Current Input/Ground Input/Output Output/Ground Input/Ground Input/Output Output/Ground 8 4 5 Basic Reinforced Operational - - Parameter Conditions/Description Max Vac Vac Vac Earth Leakage Current Touch Current Normal Condition (NC) Single Fault Condition (SFC) Normal Condition (NC) Single Fault Condition (SFC) 29µA 42µA 9µA 7µA Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Voltage 9 5/23 264 Vac Input Frequency 47 5/6 63 Hz Input Current 5Vac/max load.5 A Input Current 23Vac/max load.75 A Inrush Current 264Vac, cold start, 25 C - - 45 A Efficiency Vi nom, Io nom CINT3A58K CINT3A78K CINT3A98K - 87% - % Output Specifications Parameter Conditions/Description Min Nom Max Units Output Current V Output Current V2 Output Current V3 Output Current V Output Current V2 Output Current V3 Output Current V Output Current V2 Output Current V3 CINT3A58K CINT3A78K CINT3A98K. 4.5. 3.5 8. 3. 4. 6. 4. 4.5 2. 4. ADC ADC ADC www.slpower.com CINT3 REV.2, 9-SEP-4 4

CINT3 W Triple Output Output Specifications (continued) Parameter Conditions/Description Min Nom Max Units Static Line Regulation V Vi min-vi max, Vi nom, -% Io max -2-2 % Vo nom Static Line Regulation V2 Vi min-vi max, Vi nom, -% Io2 max -3-3 % Vo nom Static Line Regulation V3 Vi min-vi max, Vi nom, -% Io3 max - - % Vo nom Static Load Regulation V (Droop Characteristic) Static Load Regulation V2 (Droop Characteristic) Static Load Regulation V3 (Droop Characteristic) Vi min-vi max, Vi nom, -% Io max -2-2 % Vo nom Vi min-vi max, Vi nom, -% Io2 max -3-3 % Vo nom Vi min-vi max, Vi nom, -% Io3 max - - % Vo nom Hold-Up Time Vin = 2Vac, Po = W 6 - - ms Dynamic Load Regulation V, V2, V3 Load change =5%, di/dt =.2A/µS 3 % Vo nom Start-Up Time Vin = 5Vac, Io nom - 2 S Ripple & Noise V 2MHz bandwidth % % Vo nom Ripple & Noise V2 2MHz bandwidth % % Vo nom Ripple & Noise V3 2MHz bandwidth 2% % Vo nom Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Fuse T2.5A/25V internal fuse in both line & neutral Not user accessible Input Transient Protection 2KV(CM) and KV(DM) surge 2 KV (CM) Short Circuit Protection Overload Protection Hiccup Mode Hiccup Mode Overvoltage Protection Latching Type, recycle AC input to reset See models chart for trip ranges Characteristic Curves (Note: All waveforms below are based on CINT3A58K model) Output vs. Temperature 8W convection cooled and W continuous with 2 LFM airflow. Derate output power to 5% at 7 C. Output Power (W) 2 8 6 4 2-2 3 4 5 6 7 Temperature ( C) Convection 2LFM Cooling www.slpower.com CINT3 REV.2, 9-SEP-4 5

CINT3 W Triple Output Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with.µf ceramic and a µf electrolytic capacitor connected in parallel across it, BW limit with 2MHz. Output Transient Response V 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%. Output Transient Response V2 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%. www.slpower.com CINT3 REV.2, 9-SEP-4 6

CINT3 W Triple Output Output Transient Response V3 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%. Output Overload Characteristic V Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention. Output Overload Characteristic V2 www.slpower.com CINT3 REV.2, 9-SEP-4 7

CINT3 W Triple Output Output Overload Characteristic V3 Output Short Circuit Characteristic V Supply shall protect itself against Short Circuit conditions. The Power Supply shall recover from short circuit conditions without operator intervention. Output Short Circuit Characteristic V2 www.slpower.com CINT3 REV.2, 9-SEP-4 8

CINT3 W Triple Output Output Short Circuit Characteristic V3 Output Overvoltage Characteristic V Supply shall protect itself against over voltage conditions. The Power Supply shall latch and require AC input recycle to reset. AC input 9V 6Hz AC input 264V 5Hz Output Overvoltage Characteristic V2 www.slpower.com CINT3 REV.2, 9-SEP-4 9

CINT3 W Triple Output Output Overvoltage Characteristic V3 Startup Time Hold-up Time Start up time is <2seconds Hold up time is 6mS minimum Power Fail Signal Timing Active Low TTL logic signal goes high - 5 ms after main output; it goes low at least 6 ms before loss of regulation. Data Sheet 22 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com CINT3 REV.2, 9-SEP-4