GSM/GPRS MODEM CARD Model: DP-OPT-CARD-GPRS. SIM Card Requirements, Activation of Remote Comms, How to set APN for GSM Network

Similar documents
Instruction Manual. Replacing 2G GSM/GPRS Modem with GSM/3G MODEM CARD Model: DP-OPT-CARD-3G. Supplied by:

COMWAY LED Remote Display Starter Kit

GM862-GPS-OT User Guide

Thermoguard. Thermoguard GSM Modem COM Server Version Version 2.94

IRIS Touch Firmware Enhancements and Additions From Version to Version 1.11

Thermoguard. Thermoguard GSM Modem Serial Version Version 2.94

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed.

WINDOWS NT 4.0 USER GUIDE

AVL-900 Hardware Quick Installation Guide

Insight Communicator User Manual: First Edition For use with Insight software version May 28, Copyright 2007 Inner Range Pty. Ltd.

Inmarsat BGAN M2M Hughes 9502 Terminal Setup Guide

GSM GPRS Modem 900 / 1800

GH4000 Sample User Guide 1.0

SUPPORT GUIDE FOR THE NOKIA 6510 WITH AN INFRARED DATA CONNECTION IN PSION DEVICES

DCP Digital Communication Platform

OCIO GSM. M0148ITEN rev. 1 ENGLISH

WINDOWS 95 SETUP GUIDE

Service Managed Gateway TM. Installing and Configuring the GW8600 SMG

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

The JA-80Y GSM communicator

GSM manual and Software User Guide

Victron Global Remote Victron Ethernet Remote

InTimeGo-623 Pets GPS Tracker User Manual

Application Notes for InteractCRM SMSConnect 1.0 with Avaya Interaction Center Release Issue 1.0

APPLICATION NOTE. GSM Configuration Guide for D-500 D-700. Introduction

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

APS-3 Revision Important Quick Start Guide. Typical Box Contents

InTimeGo-630 GPS Watch Tracker User Manual

GPS PERSONAL TRACKER. User Manual. Error! No bookmark name given.

RadioSecure SLM Starter Kit User Manual

GSM Voice Active Monitoring OTP-GSM89

Using FleetBroadband LaunchPad on the JUE-250 and JUE-500

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

SIM900 demonstration projects. Introduction

Chiron Technology. IRIS 8xx Series Alarm over IP Dialler. Installation and User Guide

From the 8th of April 2011, Blue Chip s SMS service will be provided by MessageNet.

Mitel MiContact Center Enterprise INTEGRATED APPLICATIONS SCRIPT MANAGER USER GUIDE. Release 9.1

climote HUB Installation Guide

Altus APS3G Quick Start guide

BGS2 GPRS Modem ER75i Router ETM450 Router

CT-Interface & IRIS Touch 600 Range Installation Manual

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

Alarm button Contact GSM-1M

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

User s Manual. SJ-5291 Mini GPS Tracker GPRS+GPS. Sheng Jay Automation Technologies Co., Ltd.

SNYPER 2G & 3G. Quick Start Guide. Cellular Signal and Network Analyser. Rev 1.4

The JA-80Y GSM communicator (valid for software version XA61008 or higher)

GM-900 GSM/GPRS modem. Application manual

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania

Set-Up Instructions. Set-Up Instructions. Unpack the machine and its components.

CellRoute 3G. Fixed Wireless Terminal. Data Connectivity

between your mobile and

QTech 3G Cellular Modem CM910. Quick Start Guide

GSM communicator GD-06 Allegro Complete manual

S911 Personal Locator V4 Utility & Quick Start Manual

Banner Connected Data Solutions Web Service

TK-STAR GPS TRACKER USER MANUAL

Haicom HI-604 GPS Tracking Device with 5-years Standby Battery

SMS messages - How to configure 2SMS and SMS2 features?

AMS-8061 First Use. A quick step by step guide

GSM-AUTO GSM Controller User manual

Operating instructions Communication Software OTT Hydras 3 Rx. English

CCTR-820 Mini Water-proof GPS Tracker Using Guide

NMC Surveillance System (Android App) NMC Surveillance System (Android App) Page 01

Corporate Web Portal. Management of employee mobile accounts

FREQUENTLY ASKED QUESTIONS

Hardware Quick Installation Guide

Roadstar Configuration Instruction Manual

Advisor Advanced UltraSync Reference Manual

GSM communicator G16 USER MANUAL

(SeTracker2)User guide

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide

GRASP Designer User Manual Draft Version - English Edition

ProLine GSM. Installation manual

IMMS-CELL-GSM. Cellular Communications Kit. Installation Instructions

TK-STAR GPS TRACKER USER MANUAL

ComNav Installation Manual

Bike Tracker. Simple to install and setup, Low Cost, No Subcription, Portable

CCTR-630 GPS Watch Tracker User Manual ---V1

ELDES SECURITY APP QUICK GUIDE

USB 3G Modem. Installation/User Guide Revision 1.6 PR0496-3G

GC-101 GPS / GSM Micro Tracker

GTM-201 Series FAQ Ver1.1. GTM-201 Series FAQ ICP DAS CO., LTD.

GSM SECURITY AND CONTROL SYSTEM ESIM021

User Guide. Billing Accounts. Version Issue Date - 30th January 2014

MONGOOSE VT606 GPS VEHICLE TRACKER

CellFax Plus. Installation and User Manual

Everyday Customer Support

GSM Fixed Wireless Terminal WT User s Manual

Document Name: GPRS Startup. GPRS Startup_V01.00 Status: Created

MAINTEX. User Guide INS571

GPRS/SMS Reporting Module GPRS-T2

TR-151A / TR-151E Vehicle/Asset Tracker User Manual. Version 2.3

SYNOPSIS PROJECT TITLE : GSM BASED E-NOTICE BOARD

1. QUICKSTART GUIDE TOOLBAR ADMIN LOWER TOOLBAR DEVICES CLIP DB MONITORING GSM SETTINGS...

River Bank & Trust Online Banking Initial Log In Instructions

Configuring a GSM (3G) modem on a GW2040 Series Router

CCTR-800/801/803 Vehicle Real Time GPS Tracker

VBIP-G. Mobile Communicators. Installer Manual VBIP-G, VBIP-3G. Rev

GpsGate SMS Proxy. Installation and Administration Guide. Version: Rev: 1

Transcription:

GSM/GPRS MODEM CARD Model: DP-OPT-CARD-GPRS SIM Card Requirements, Activation of Remote Comms, How to set APN for GSM Network - Retrofit to (or supplied with) DIGICHEM Plus + Controllers - For Remote Connection to www.digichemplus.com Please complete last page and submit to Waterco for Webserver Setup Supplied by: M1 ver 1.2 0

1. SIM Card Requirements A standard size SIM card is required for the GSM/GPRS modem to operate. The SIM card must be activated for Voice (for SMS) and 2G GPRS Data. Estimated data usage 10-20MB/month. Depending on which service provider you choose, the SIM cards should have the following characteristics: The SIM Card should have the facilities for both DATA, and SMS communication. Billing of DATA transfer will be in incurred on the DATA number. The DIGICHEM Plus+ Controller will not SMS alarms directly from the SIM card. This is dealt with from the Webserver, and no SIM Card alarm SMS bills will be accumulated. The SMS s will be forwarded by a 3 rd party, that will be initialised by an alarm condition from the Webserver. Note: It is recommended, if possible to have outgoing voice calls barred on the SIM Card, whilst still being able to send and receive SMS. This is however, often not possible, as to enable SMS transmission, VOICE needs to be enabled. 2. Installing the SIM Card IMPORTANT: Before installing SIM card, it is necessary to disable the PIN on the SIM card. Please insert the SIM card into a compatible mobile phone. On start up, if the phone prompts you for a PIN, which is usually 0000, please go into Settings and disable this feature. You can confirm it is disabled by turning the phone off and on again. You should go straight to the main screen on the phone WITHOUT being prompted for a PIN. 1

Please see the diagrams below, and follow steps 1 to 5. Figure 1 Figure 2 Figure 3 1. To insert the SIM Card into the holder, slide the silver clip to the left as per figure 1 (if already not done), and lift up the top flap. 2. Slide the sim card into the top flap, between the silver clip, and sheath of the top flap as shown above in figures 2 & 3. 3. Make sure the positional tab on the SIM Card is towards the top, left hand corner, as shown in figure 2. Slide the card in all the way figure 3. 4. Push the top flap down firmly, and slide the silver clip to the right, as shown below in figure 4. Figure 4 5. The SIM Card is now installed, and the top flap should be secure, and should not be able to be lifted. 2

3. Enabling Remote Comms The remote communications in the DIGICHEM Plus+ controller requires activation. Please follow the instructions below for this procedure. For a full explanation of how to operate through the menu structure, please consult the DIGICHEM Plus+ instruction manual. The default GSM Logon cycle time to the remote server is once every 15 minutes (See Section 2 above for further explanation). This time can only be altered via the web based software, and cannot be edited from the DIGICHEM Plus+ controller. It is however recommended to keep it at 15 minutes or to increase, rather than decrease this GSM Logon Cycle. Please follow the example below of how to implement this feature on the DIGICHEM Plus+ controller: Main Menu > SETUP MENU > ADVANCED SETUP > REMOTE COMS. Once logged on, the server is updated from the DIGICHEM Plus+ Controller. If alarm conditions exist, the various contact people set up in the web based software are contacted via SMS, and/or e-mail depending on the software s setup parameters. 3

4. Setting Network APN Each service provider has an APN number, (Access Point Name), which is a unique number that identifies that service provider s network. Each DIGICHEM Plus+ Modem needs to know this APN number of the service provider. To set the correct APN, an SMS will be required to be sent via the Modem s SIM Card from a mobile phone, while the modem is on and communicating. Please select and enter the appropriate text message from the table below into a mobile phone, ready to send for the following service providers but do NOT send the text message yet, continue reading these instructions: NOTE: All text is CASE SENSITIVE, so please check The underscore ( _ ) represents a space character The text is to be sent to the Voice number of the SIM Card Service Provider: Network Text Message to be sent: AQUAGPRS,APN=XXX,YYY,ZZZ# Where: XXX = Network APN YYY = Username ZZZ = Password For many networks, the Username and Password is blank, as per the examples below. Vodafone AQUAGPRS,APN=vfinternet.au,_,_# 1. In the Send to Number Menu of your mobile phone, enter the telephone number of the SIM Card into your mobile phone, but do NOT press the send button yet. 2. The Modem must be activated in order for the relevant text message to be received by the SIM Card. In order to activate the Modem, please enter the 4

TEST Outputs menu of the DIGICHEM Plus+ controller, and test the modem as shown in the diagram below: (For a full explanation of how to operate through the menu structure, please consult the DIGICHEM Plus+ user manual.) Main Menu > TEST OUTPUTS. 3. Once the Modem messages start appearing on the last line of the display, send the text message immediately. 4. To test if the Modem has received the relevant text message, perform the steps in section 4.2 below. 5. Polling Modem to check if correct APN is Set To check whether the Modem contains the correct APN number: 1. Enter the following text into a mobile phone: AQUAGPRS,APN? NOTE: All text is CASE SENSITIVE, so please check This text is to be sent to the DATA number of your SIM card 2. In the Send to Number Menu of your mobile phone, enter the Phone No of the SIM Card into your mobile phone, but do NOT press the send button yet. 5

3. Do not send the text yet, and turn the modem on by following from Step 3 of Section 4.1 on the previous page. Complete all remaining steps in that section. 4. Within around 3 15 seconds, you should receive a text to the mobile phone that you sent the original message from. 5. This text should confirm the APN number that is in the Modem, as per the example in the following table: Service Provider: Vodafone APN Setting: APN Settings:vfinternet.au,_,_ NOTE: The underscore ( _ ) represents a space character Note: The SMS charge will not be billed from the service provider of the SIM Card. For Loss of Communication Alarm - this alarm will only be sent if the controller cannot log on to the Webserver after 100 sequentially failed GSM Logon Cycles. For example, if the Webserver Interval is 15 minutes, then the Communication Lost Alarm will only occur after 15 x 100 minutes = 1500 minutes (i.e. 25 hours) 6

DIGICHEM Plus+ Registration Please print out and fax, or e-mail this page to Waterco to register & activate your DIGICHEM Plus+ Controller on www.digichemplus.com. Company: Authorised person: Contact number: Date: Hold the Red button (View Settings) down for 3 seconds on the DIGICHEM Plus+ Controller to obtain the ID of the controller: DIGICHEM Plus+ ID: Service Provider: SIM Card Voice No: Please check the silver label on the DIGICHEM Plus+ Controller, and enter the serial number of the unit below. (The serial number can also be found on other silver labels either on the PVC backboard or Cabinet if ordered) DP+ Serial Number: Site Name: (16 Characters max) Controller Name: (16 Characters max) 7