TraNET FE Data Acquisition Instrument

Similar documents
14 Bit rsp. 16 Bit. 80 MS/s 40 MS/s 20 MS/s 10 MS/s

Measurement Equipment for Future Transient Recorder TransCom-CompactX MF Instruments GmbH

6220 Ethernet-Based Voltage Measurement Module

GFT6084 Quad 2 / 4GS Digitizer

6220 Ethernet-Based Voltage Measurement Module

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

Keysight Technologies U2500A Series USB Modular Simultaneous Sampling Multifunction DAQ Devices

Features. RoHS COMPLIANT 2002/95/EC

USB 1608G Series USB Multifunction Devices

USB 1608G Series USB Multifunction Devices

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

E Series Multifunction I/O 1.25 MS/s, 12-Bit, 16 or 64 Analog Inputs

USB-1602HS-2AO Specifications

Portable E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs

PC104P-24DSI Channel 24-Bit Delta-Sigma PC104-Plus Analog Input Board

PCIe-20AO8C500K. 20-Bit 8-Output 500KSPS Precision Wideband. PCI Express Short-Card Analog Output Module

M4i.44xx-x8-14/16 bit Digitizer up to 500 MS/s

PMC-16AIO 16-Bit Analog Input/Output PMC Board With 32 Input Channels, 4 Output Channels and 16-Bit Digital I/O Port

ADQ412. Product Preview. Features. Introduction. Applications. Software support. Ordering information. ADQ Development Kit

PC104P-16AIO Bit Analog Input/Output PC104-Plus Board

PC104P-16AO20 20-Channel 16-Bit High-Speed Analog Output PC104-Plus Board With 440,000 Samples per Second per Channel, and Simultaneous Clocking

6224 Ethernet-Based Strain Measurement Module

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

24DSI16WRC Wide-Range 24-Bit, 16-Channel, 105KSPS Analog Input Module With 16 Wide-Range (High-Level, Low-Level) Delta-Sigma Input Channels

Overview: Functional Description:

Low Cost Multifunction I/O 100 ks/s, 12-Bit, 8 Analog Inputs

16-Channel 16-Bit PMC Analog I/O Board

cpci6u-24dsi32r 32-Channel 24-Bit Delta-Sigma Analog Input Board

CCVPX-16AI32SSC1M. 32-Channel, Differential, 16-Bit Simultaneous Sampling; Conduction-Cooled VPX Analog Input Board

XMC-16AI32SSC1M. 32-Channel, Differential, 16-Bit Simultaneous Sampling XMC Analog Input Board

PMC-12AI Channel, 12-Bit Analog Input PMC Board. With 1,500 KSPS Input Conversion Rate

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

PCIe-24DSI12WRCIEPE 24-Bit, 12-Channel, 105KSPS Transducer Input Module With 12 Wide-Range Delta-Sigma Input Channels and IEPE Current Excitation

Digital Storage Oscilloscope

DC140 1 GHz 2 GS/s DC GHz 1 GS/s. Ctrl I/O. Dual-Channel 3U PXI/CompactPCI High-Speed Digitizers

Analog Input Sample Rate

DT9828. Low-Cost, Isolated, Thermocouple Measurement Module. Overview. Key Features. Supported Operating Systems

64-Channel, 16-Bit Simultaneous Sampling PMC Analog Input Board

LGR-5327 Specifications

LGR-5325 Specifications

CPCI-16AIO Channel 16-Bit Analog I/O CPCI Board With 8 Input Channels, 8 Output Channels, and Auto calibration

PMC66-18AI32SSC1M: PMC, Single-width

PC104P-24DSI6LN. Six-Channel Low-Noise 24-Bit Delta-Sigma PC104-Plus Analog Input Module. With 200 KSPS Sample Rate per Channel

cpci6u64-20aof16c500kr

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

Sefram SEFRAM DAS 20/DAS 40. Sefram

DT9800 Series. USB Function Module for Data Acquisition

PCIe-16AOF Bit, 64/32-Channel, 500KSPS PCI Express Analog Output Board. With Reconstruction Output Filters

PCI-12AIO 12-Bit Analog Input/Output PCI Board

16-Bit, 12-Channel, 2-MSPS PMC Analog Input/Output Board

TranAX 4. User manual. Data Acquisition Application Software

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

16AIO 16-Bit Analog Input/Output Board With 32 Input Channels, 4 Output Channels and 16-Bit Digital I/O Port

PC104P-16AO2-MF Two-Channel 16-Bit High-Speed Analog Output PMC Board With 400,000 Samples per Second per Channel, and Independent Clocking

M2i.30xx - 12 bit transient recorder up to 200 MS/s

Power over Ethernet Load Module

PC104P66-16HSDI4AO4:

DIG-100M1002-PCI. Features. 100MSPS 2ch Digitizer Board for PCI DIG-100M1002-PCI 1. Ver.1.03

12AI Channel, 12-Bit Analog Input PMC Board. With 1,500 KSPS Input Conversion Rate

PCI-16HSDI: 16-Bit, Six-Channel Sigma-Delta Analog Input PMC Board. With 1.1 MSPS Sample Rate per Channel, and Two Independent Clocks

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

M2i.31xx - 8 channel 12 bit A/D up to 25 MS/s

PMC-16AI Channel, 16-Bit Analog Input PMC Board. With 500 KSPS Input Conversion Rate. Features Include: Applications Include:

16-Bit, 12-Channel, 2-MSPS PMC Analog Input/Output Board

16-Channel 16-Bit Differential High-Speed PMC Analog Output Board

Specifications USB-1616HS

M2p.59xx-x4-16 bit general purpose Digitizer

14-Bit, 4-Channel, 50MSPS/Channel PMC Analog Input Board

PMC-12AIO. 12-Bit PMC Analog Input/Output Board

PCI Bit High Resolution Dynamic Signal Acquisition and Generation User s Manual

XMC-24DSI24WRC Wide-Range 24-Bit, 24-Channel, 200KSPS XMC Analog Input Module With 24 Wide-Range (High-Level, Low-Level) Delta-Sigma Input Channels

16AIO Bit Analog Input/Output Board. With 16 Input Channels and 8 Output Channels

SCP for Plastics Processing

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

PCIe-24DSI64C200K. 24-Bit, 64-Channel, 250KSPS, PCI-Express Module. With 64 Differential Delta-Sigma Input Channels. Features Include: Applications:

64-Channel, 16-Bit Simultaneous Sampling PMC Analog Input Board

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

PCIe-24DSI64C200K. 24-Bit, 64-Channel, 250KSPS, PCI-Express Module. With 64 Differential Delta-Sigma Input Channels. Features Include: Applications:

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

14HSAI4. 14-Bit, 4-Channel, 50MSPS/Channel PMC Analog Input Board. With 66MHz PCI Compatibility, Multiple Ranges, and Data Packing

PCIe-16AO64C. 16-Bit, 64/32-Channel, 500KSPS PCI Express Analog Output Board. With Optional Outputs-Disconnect

M2i.49xx - 8 channel 16 bit A/D up to 60 MS/s

PCI-DAS1602/12 Specifications

Keysight U2751A USB Modular Switch Matrix

DRTS 33. The new generation of advanced three phase relay test set

USB-2527 Specifications

A 40-pin connector provides access to 24 DIO connections.

Model M3i.32XX, 12 bit transient recorder up to 500 MS/s

Compact 8 in 1 Multi-Instruments SF Series

12-Channel, 12-Bit PMC Analog Input/Output Board

32-CHANNEL 16-BIT TRANSDUCER INPUT PMC

M3i.21xx - 8 bit transient recorder up to 1 GS/s

M2i.49xx - 8 channel 16 bit A/D up to 60 MS/s

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

GDS-2000 Series. Features

CPCI-12AI Channel, 12-Bit Analog Input CPCI Board With 1,500 KSPS Input Conversion Rate

Handyscope HS3. User manual. TiePie engineering

M2i.20xx - 8 bit transient recorder up to 200 MS/s

MI.30xx - 12 bit transient recorder up to 200 MS/s

Transcription:

TraNET FE Data Acquisition Instrument Datasheet The TraNET FE instrument turns your computer into a powerful Data Acquisition System Elsys AG Mellingerstrasse 12 CH-5443 Niederrohrdorf Switzerland Phone: +41 56 496 01 55 Email: info@elsys.ch Internet: www.elsys-instruments.com

The family of modular TraNET data acquisition instruments provides turnkey solutions to many complex measurement problems. TraNET data acquisition systems are flexible, compact and portable. They can be used to solve in situ problems in automotive, power generation, transportation and train systems. The TraNET system allows you to monitor a remote engine via LAN, or verify and test an injection system. With the Continuous Data Recorder mode, a long duration event can be stored to disk, gap free in real-time, and analysed later. If applications require complex triggering across many channels, TraNET can help you capture sequential blocks of data, without any loss, using the unique ECR Event Controlled Recording mode. The powerful application software TranAX not only helps to quickly configure many acquisition channels, but also provides the right post-processing tools to analyse complex waveforms. General Specification Ethernet Connection: Gbit, RJ45 connector Hard disk: 200 GB SSD Power Supply: 100 V - 250 V, 50/60 Hz Power Consumption: TraNET 204 TraNET 404 max. 40 W max. 60 W Operating Temperature: 0.. 45 C Storage Temperature: -20.. 60 C Rel. Humidity: Up to 31 C: < 80% 31 C..45 C: decreasing to < 50% Max. Operating Elevation: 2 000m Recording Modes: Scope, Mulit Block, Continuous, ECR Dual sample rate recording (with ECR only) Digital inputs (Markers) (synchronized with analog signals) LXI compatible IVI-Driver with sample programs for C++/C#, VB and Lab- VIEW Device configuration over embedded Website Device Synchronisation Sync-Link In some time-critical applications it is necessary to synchronize multiple instruments with a common reference clock and a common trigger in order to compare data acquisitions across multiple devices. The TraNET Sync-Link box takes care about these two important tasks. The Sync-Link box is available in two variants for up to 8 or 16 devices, allowing systems up to 256 inputs. The Sync- Link can also be used with the TraNET PPC or TraNET EPC devices allows systems even up to 1024 inputs. GPS Synchronisation TraNET FE devices can be equipped with a GPS receiver module for time synchronisation or location tracking. GPS timing synchronisation allows to sync several TraNET or 3rd part measurement devices without any cable connection between them. Specification Timing precision: < 12.5 ns Connector/Cable: RJ45, Cat. 6 Max Cable length: 10 m (longer cable on request) Specification: Timing precision: ±2 us Long time drift: 0 ppm 6 channel GPS C/A-code receiver up to 300 m distance to antenna 2016 Elsys AG www.elsys-instruments.com 2

Model Name # of Channels Max. Sample Rate ADC Resolution Memory TraNET FE 204 TraNET FE 204 devices are equipped with up to two 4-channel modules or one 8-channel TPCE DAQ module. On Single Ended modules (SE) two inputs can be linked together for having a differential input. Differential ended modules (Diff) can also be used in single ended mode by using only the positive input. For more detailed information see the specification table at pages 6/7. Dimensions & Weight 234 x 76 x 289 mm 3.1 kg 1x4S/02/16 4 2 1x4D/02/16 4 4 2x4S/02/16 8 4 SE DIFF per channel* 2 MS/s 16 Bit 1x8S/02/16 8 4 16 MS (64 MS) 1x4S/10/16 4 2 1x4D/10/16 4 4 2x4S/10/16 4 2 10 MS/s 16 Bit up to 5 MS/s 1x8S/10/16 8 4 16 MS (64 MS) 1x4S/20/16 4 2 1x4D/20/16 4 4 2x4S/20/16 8 4 20 MS/s 16 Bit up to 5 MS/s 1x8S/20/16 8 4 16 MS (64 MS) 1x4S/40/16 4 2 1x4D/40/16 4 4 2x4S/40/16 8 4 1x4S/80/16 4 2 1x4D/80/16 4 4 2x4S/80/16 8 4 1x4S/120/16 4 2 1x4D/120/16 4 4 2x4S/120/16 8 4 1x4S/240/16 4 2 1x4D/240/16 4 4 2x4S/240/16 8 4 40 MS/s 80 MS/s 120 MS/s 240 MS/s 16 Bit up to 10 MS/s 16 Bit up to 20 MS/s 16 Bit up to 60 MS/s 16 Bit up to 60 MS/s TraNET FE 404 TraNET FE 404 devices are equipped with up to four 4-channel modules or two 8-channel TPCE DAQ modules. On Single Ended modules (SE) two inputs can be linked together for having a differential input. Differential ended modules (Diff) can also be used in single ended mode by using only the positive input. For more detailed information see the specification table at pages 6/7. Dimensions & Weight 234 x 115 x 289 mm 4.3 kg Model Name # of channels Max. Sample Rate ADC Resolution Memory 3x4S/02/16 12 6 2x4D/02/16 8 8 4x4S/02/16 16 8 SE DIFF per channel* 2 MS/s 16 Bit 2x8S/02/16 16 8 16 MS (64 MS) 3x4S/10/16 12 6 2x4D/10/16 8 8 4x4S/10/16 16 8 10 MS/s 16 Bit up to 5 MS/s 2x8S/10/16 16 8 16 MS (64 MS) 3x4S/20/16 12 6 2x4D/20/16 8 8 4x4S/20/16 16 8 20 MS/s 16 Bit up to 5 MS/s 2x8S/20/16 16 8 16 MS (64 MS) 3x4S/40/16 12 6 2x4D/40/16 8 8 4x4S/40/16 16 8 3x4S/80/16 12 6 2x4D/80/16 8 8 4x4S/80/16 16 8 3x4S/120/16 12 6 2x4D/120/16 8 8 4x4S/120/16 16 8 3x4S/240/16 12 6 2x4D/240/16 8 8 4x4S/240/16 16 8 40 MS/s 80 MS/s 120 MS/s 240 MS/s 16 Bit up to 10 MS/s 16 Bit up to 20 MS/s 16 Bit up to 60 MS/s 16 Bit up to 60 MS/s * Values in () are optional 2016 Elsys AG www.elsys-instruments.com 3

Device Options DC Powered TraNET FE devices are equipped with an internal 110/230V AC power supply. Optional the device is available with a DC power supply input. This allows to use 12 V car DC power or solar panels and battery packs. DC powered TraNET FE are delivered with an external 110/230V AC/DC power supply for using the device at the standard main power line. Specification: Input Voltage: 10-36 VDC Power Consumtion: 30-60 W (depends on installed cards) Powerplug: SFV 40 (IEC 60130-9) Dust-Proof TraNET FE Dust-Proof devices are the perfect data acquisition instruments for dusty and muddy environment. They do not have any ventilation to the outside, preventing any air flow entering the device. The Dust-Proof option is available for the 204 or 404 chassis type and all different sampling rates. Operating conditions Operating Temperature: 0.. 35 C, higher temperature possible when free air flow is applied over the instrument. Storage Temperature: -20.. 60 C Rel. Humidity: Up to 31 C: < 80% 31 C..45 C: decreasing to < 50% Max. Operating Elevation: 2 000m 2016 Elsys AG www.elsys-instruments.com 4

Software TranAX TranAX is the universal data acquisition software from Elsys designed for TPCX/TPCE data acquisition cards and the turnkey TraNET data acquisition instruments. Key Features: Configures quick and easy many analog input channels, no programming required Data visualization in Multi-Waveform displays Several cursor for easy data readout and reporting X-Y data display FFT Analysis width different scaling and windows function Measurement data - video synchronization More than 40 scalar functions to measure any significant waveform parameter on time or FFT curves Powerful formula editor for more than 60 mathematics functions, syntax highlighting, for-loops, array calculations, string manipulations, etc. Curve fitting (Polynomial regression) Autosequence-macro s for easy to set up, fast automated measurements English and German version LabVIEW Instrument Driver TranAX Waveform Display Documentation Page Elsys provides a LabVIEW instrument driver which is fully compliant with the NI driver design guidelines. The instrument drivers provides the following features: Key Features: Ready-made measurement flow-control VI s for scope, multliblock, continuous and ECR measurement modes Express VI s for amplifier and trigger settings VI s for data readout Express VI s for setup the connection to the modules/instruments C++/C# TpcAccess API TpcAccess API is based on a client/server architecture and can be integrated in any custom specific software. It handles all network traffic and synchronisation task when several clients are connected to the same device. Formula Editor for Post-Processing Elsys Tool Box in LabVIEW 2016 Elsys AG www.elsys-instruments.com 5

TPCE Module Specification Module Type TPCE-24016-4 TPCE-12016-4 TPCE-8016-4 TPCE-4016-4 Number of Input Channels SE Module Number of Input Channels DIF Module Max. Sample Rate (all channels are sampled simultaneously) Amplitude Resolution 4 single ended or 2 differential software switchable 4 single ended or 4 differential software switchable 4 single ended or 2 differential software switchable 4 single ended or 4 differential software switchable 240 MHz 120 MHz 80 MHz 40 MHz 16 Bit up to 60 MHz up to 240 MHz 16 Bit up to 60 MHz up to 120 MHz 16 Bit up to 20 MHz up to 80 MHz 16 Bit up to 10 MHz up to 40 MHz Memory (per Module) Standard: 4 x 32 MWords (= 256 MByte) Optional: 4 x 128 MWords (= 1 GByte) Input Amplifier Measurement Ranges ±50 mv ±50 V rsp. 0.1 V 100 V (100 V limited to 70 V) in 1, 2, 5 Steps Offset 0 100 % in steps of 0.1% (Resolution 0.01 %) Input Impedance 1 MΩ (± 0.2 %) or 50 Ω (± 0.5 %) // 26 pf (± 5 %) 1 MΩ (± 0.2 %) // 35 pf (± 5 %) Coupling AC / DC software switchable (AC: -3 db at < 5 Hz), Inputs invertible Bandwidth at Range 1 V 120 MHz 60 MHz 30 MHz 18 MHz Bandwidth at Range < 1 V 80 MHz 50 MHz 8 MHz 7 MHz Slew Rate (10 90 %) @ Range 1 V 4 ns 6 ns 13 ns 25 ns Slew Rate (10 90 %) @ Range < 1 V 6 ns 9 ns 50 ns 60 ns Settling Time to 1% < 200 ns < 200 ns < 200ns < 200 ns Low Pass Filter (RC-Filter) 2 Steps ( 1 MHz and 100 khz) software switchable Antialiasing-Filter (optional) 200 Hz 5 MHz, min. 4. order Butterworth, software setable Common Mode Range Differential-Mode: ±8 V or +/-80 V at ranges. > 5 V Common Mode Rejection > 74 db (DC 1 khz); > 60 db ( 100 khz); > 40 db ( 5 MHz) Range Error (±) Offset Error (±) Offset Drift (±) Input Noise: @ max. Sample Rate @ 5 MHz Sample Rate @ 1 MHz Sample Rate @ 100 khz Sample Rate @ 10 khz Sample Rate Signal to Noise Ratio SNR: @ max. Sample Rate @ 10 MHz Sample Rate @ 5 MHz Sample Rate @ 1 MHz Sample Rate @ 100 khz Sample Rate @ 10 khz Sample Rate Channel Isolation (Crosstalk) @ 10 khz Ranges < 1V Special : Autocalibration Trigger Number of Trigger Channels Advanced Trigger (Option) External Trigger input Trigger Delay Miscellaneous Digital Inputs (Marker) Ext. Control Inputs (TTL)) Status Outputs (TTL) ICP Sensor Supply (Option) max. 0.1 % typ. 0.07 % max. 0.1 % typ. 0.07 % < 0.250 mvrms < 0.120 mvrms < 0.070 mvrms < 0.040 mvrms < 0.025 mvrms 59 db 62 db 66 db 69 db 89 db max. 0.1 % typ. 0.03 % max. 0.1 % typ. 0.02 % max. (0.0100 % + 0.1 mv) per C, typ. (0.0050 % + 0.03 mv) per C (will be compensated by autocalibration) < 0.200 mvrms < 0.120 mvrms < 0.070 mvrms < 0.040 mvrms < 0.025 mvrms 62 db 68 db 74 db 82 db < 0.200 mvrms < 0.120 mvrms < 0.070 mvrms < 0.040 mvrms 67 db 76 db 92 db < 0.180 mvrms < 0.110 mvrms < 0.040 mvrms < 0.015 mvrms 76 db 92 db > 80 db > 60 db Auto adjustment of gain and offset in all measurement ranges. (Initiated by software) 4 coupled to analog inputs, pos./neg.edge, with or without hysteresis, Window IN, Window OUT On all analog inputs: Slew Rate, Pulse Width, Pulse Pause or Period (too short or too long = Missing Event), State (above / below), AND link, Product (trigger signal is calculated from 2 channels) 1 per System (TTL), pos. or neg. Edge -100 % (Pretrigger) to +200 % (Posttrigger) in 1 % steps 8 (2 per analog channel) (TTL) Optocoupler Connection Box (5 to 48 V) as additional option Trigger, Arm/Disarm, Ext. Sampling (fmax = 10 MHz), external command to start recording Trigger Output, Armed (=True during recording) 4mA Integrated Current Power for piezo sensors *2 *3 2016 Elsys AG www.elsys-instruments.com 6

Module Type TPCE-2016-4/8 TPCE-1016-4/8 TPCE-0516-4/8 TPCE-0216-4/8 Number of Input Channels SE Module 4-Channel Modules: 4 single ended or 2 differential 8-Channel Modules: 8 single ended or 4 differential Number of Input Channels DIF Module 4-Channel Modules: 4 single ended or 4 differential 8-Channel Modules: 8 single ended or 8 differential Max. Sample Rate (all channels are sampled simultaneously) 20 MHz 10 MHz 5 MHz 2 MHz Amplitude Resolution Memory 4 Channel Module Memory 8 Channel Module 16 Bit up to 5 MHz up to 20 MHz 16 Bit up to 5 MHz 16 Bit up to 5 MHz 16 Bit up to 2 MHz up to 10 MHz Standard: 4 x 32 MWords (= 256 MByte) Optional: 4 x 128 MWords (= 1 GByte) Standard: 8 x 16 MWords (= 256 MByte) Optional: 8 x 64 MWords (= 1 GByte) Input Amplifier Measurement Ranges ±50 mv ±50 V rsp. 0.1 V 100 V (100 V limited to 70 V) in 1, 2, 5 Steps Offset 0 100 % in steps of 0.1% (Resolution 0.01 %) Input Impedance 1 MΩ (± 0.2 %) // 35 pf (± 5 %) Coupling AC / DC software switchable (AC: -3 db at < 5 Hz), Inputs invertible Bandwidth at Range 1 V 10 MHz 5 MHz 2.5 MHz 1 MHz Bandwidth at Range < 1 V 6 MHz 4 MHz 2.5 MHz 1 MHz Slew Rate (10 90 %) @ Range 1 V 40 ns 70 ns 80 ns 180 ns Slew Rate (10 90 %) @ Range < 1 V 70 ns 80 ns 80 ns 180 ns Settling Time to 1% < 200ns < 200 ns < 300 ns < 500 ns Low Pass Filter (RC-Filter) 2 Steps ( 1 MHz and 100 khz) software switchable Antialiasing-Filter (optional) 200 Hz 5 MHz, min. 4. order Butterworth, software setable Common Mode Range Differential-Mode: ±8 V or +/-80 V at ranges. > 5 V Common Mode Rejection > 74 db (DC 1 khz); > 60 db ( 100 khz); > 40 db ( 20 MHz) Range Error (±) max. 0.1 % typ. 0.03 % Offset Error (±) max. 0.1 % typ. 0.03 % Offset Drift (±) max. (0.0100 % + 0.1 mv) per C, typ. (0.0050 % + 0.03 mv) per C (will be compensated by autocalibration) Input Noise: @ max. Sample Rate @ 5 MHz Sample Rate @ 1 MHz Sample Rate @ 100 khz Sample Rate @ 10 khz Sample Rate Signal to Noise Ratio SNR: @ max. Sample Rate @ 10 MHz Sample Rate @ 5 MHz Sample Rate @ 1 MHz Sample Rate @ 100 khz Sample Rate @ 10 khz Sample Rate Channel Isolation (Crosstalk) @ 10 khz Ranges < 1V Special : Autocalibration Trigger Number of Trigger Channels Advanced Trigger (Option) External Trigger input Trigger Delay Miscellaneous < 0.080 mvrms < 0.030 mvrms < 0.010 mvrms 67 db < 0.080 mvrms < 0.030 mvrms < 0.010 mvrms < 0.030 mvrms < 0.010 mvrms 72dB - - < 0.030 mvrms < 0.010 mvrms - - > 80 db > 60 db Auto adjustment of gain and offset in all measurement ranges. (Initiated by software) 4 or 8, coupled to analog inputs, pos./neg.edge, with or without hysteresis, Window IN, Window OUT On all analog inputs: Slew Rate, Pulse Width, Pulse Pause or Period (too short or too long = Missing Event), State (above / below), AND link, Product (trigger signal is calculated from 2 channels) 1 per System (TTL), pos. or neg. Edge -100 % (Pretrigger) to +200 % (Posttrigger) in 1 % steps Digital Inputs (Marker) 8 rsp. 16 (2 per analog channel) (TTL) Optocoupler Connection Box (5 to 48 V) as additional option Ext. Control Inputs (TTL)) Trigger, Arm/Disarm, Ext. Sampling (fmax = ¼ of the max sample rate), external command to start recording Status Outputs (TTL) Trigger Output, Armed (=True during recording) ICP Sensor Supply (Option) 4mA Integrated Current Power for piezo sensors *1) At 16 bit modules, the resolution will be reduced to 14 bits at sample rates over 1/4 of the max. *2 *3 *4 2016 Elsys AG www.elsys-instruments.com 7

*2) The input noise depends on the sample rate. *3) At 14 bit modules the SNR will be reduced by 2 db *4) At 8-channel modules the SNR will be reduced by 3 db Elsys AG Elsys AG Mellingerstrasse 12 CH-5443 Niederrohrdorf Switzerland Phone: +41 56 496 01 55 Email: info@elsys.ch Internet: www.elsys-instruments.com Follow Us on Facebook: https://www.facebook.com/elsysinstruments/ 2016 Elsys AG www.elsys-instruments.com 8