Audia. AudiaFUSION. Manual

Similar documents
Vocia ELD-1. Operation Manual

Vocia. Page Active Relay Module (PARM-1) Operation Manual

RT Remote Translator and. WMC, IR-T, & RIK Controls

iconverter 2-Module Power Chassis

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

Automated Tuner System Power Distribution Hub

PS8 - II. Professional Power Sequencer. User s Manual

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Enhanced Mini-Chansim Model VCS-232

DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MTS-2000 USER S MANUAL

V-9908 MESSAGE/PAGE PANEL

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Zonit μats TM Users Guide μats1-lv Version 1.2

TitanONE Smart Mainframe Power Amplifier

CMSA-100 Manual. Cinema Media Server Automation

USB Ranger 422 User Guide

USB Ranger 110/410 User Guide

1x4 HDMI & Full 3D support over Single CAT5 Distribution Amplifier with Local Output. User Manual

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Vocia. VA-8600/VA-8600c. Manual

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

HDX II Owner s Manual Modular Fiber Optic HDMI Extender

SPM723 Programmable Stereo Preamp/Mixer Operation Manual

Vocia. VA-8600 Failover Module (VFOM-1) Installation Guide

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

DVI ELR Extender over one CAT5

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

EISB Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed and Unmanaged Ethernet Switching Hubs

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone

Brocade ICX 6610 Switch

Innovative Circuit Technology Ltd.

Dual Link DVI Extender

MX User Manual. Dual-View Video Processor. rev: Made in Taiwan

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

USB 2.0 Ranger High Speed Extender System. User Guide

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

Plus-X 300. Installation and Operation Manual

DVI ELR Extender over one CAT5

Vigil 3 Amplifiers. Installation Instructions

MX-5004MZ. User Manual. 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4. rev: Made in Taiwan

MXA2080. Stereo Power Amplifier. Owner s Manual

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

USER MANUAL MODEL 515 DB-15 Surge Protector

TVA2.1 2-Channel Digital Amplifier Installation Manual

User Manual rev: Made in Taiwan

USBTHERE User Guide USB204EXTFIB. Featuring ExtremeUSB Technology

APT20. User Manual.

Kramer Electronics, Ltd.

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

WR-5e Remote Control

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Line Impedance Stabilization Network (LISN)

MODEL 805 USER MANUAL

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A6

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

USB 3.0 Spectra

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

RT4B-110V/12A RECTIFIER

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Back-UPS RS 550 Installation & Operation

Series 8000 RF Signal Switch Solution

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Note: Unit is set at the factory for 120V operation. Be sure to change the fuse. (2A rating) before switching to 230V operation.

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Precise Fiber Couple Laser Light Source

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

User Guide. Model No.: GDI-CTDK201/203/208

CAT5 Extender User Manual

UHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation

Transcription:

Audia AudiaFUSION Manual Biamp Systems 9300 S.W. Gemini Drive Beaverton, OR 97008 USA +1.503.641.7287 www.biamp.com

IMPORTANT SAFETY INSTRUCTIONS

table of contents audiafusion................................................................................ 3 FEATURES... 3 front panel.............................................................................. 4-5 Setup and Use................................................................................. 4 System Indicators.... 4 Chassis Indicators.... 5 rear panel....6-9 Serial Control Port.... 6 Power Entrance... 6 NM-1......................................................................................... 6 Logic I/O... 6 Ethernet...................................................................................... 6 CobraNet..................................................................................... 6....................................................................................... 7 Output.... 7 Amplifier-to-Amplifier Failover................................................................... 8 Channel-to-Channel Failover..................................................................... 9 AudiaFUSION & CARD specifications.... 10 115 VAC Current Draw and Heat Output........................................................... 11 Block diagram... 12 warranty................................................................................. 13

audiafusion alarm activity signal 1 signal 2 status ais power AudiaFUSION is the newest member of the Audia family, bringing together open-architecture DSP, Multi-Channel Amplifier technology, and device- and load-monitoring capabilities. AudiaFUSION features an 8-channel modular amplifier, 16x16 I/O via CobraNet and DSP with support for channel-to-channel and device-to-device failover. AudiaFUSION can support up to 8 amplifier cards that are individually software configurable from 100-600 watts for up to 2400 watts of power, with software-selectable 70V, 100V and low impedance outputs per card. Intuitive software provides audio system design via PC and allows easy selection, viewing and calibration of numerous audio components: mixers, combiners, matrixes, equalizers, filters, crossovers, dynamics, routers, delays, meters, generators, diagnostic tools, and more. Once a system design is compiled, it is downloaded into AudiaFUSION, where it can be controlled via AMX, Crestron, other third-party control system, or via computer running davinci control software. When installed in a system together, AudiaFLEX and Audia- FUSION processing resources are allocated as needed, making the whole system more efficient.. FEATURES Modular based design Amplification modules have software configurable power levels/load options 8 amplification modules per frame with 100W to 600 Watts per module (maximum of 2400W per chassis) 70 V or 100 V with direct drive capability, or low-impedance (4 or 8Ω) operation Maximum of 2400 watts of power in 3 rack unit device TCP/IP Network controllable LED Indication: Signal present Peak present Clip present Heat sink temperature fault Amplifier failure Fan stuck-rotor Internal amplifier module failover mode Entire device failover mode Software Monitoring Features: Peak present Heatsink temperature value, warning and fault Short circuit on output Amplifier failure Impedance min/max threshold warning Excessive clipping Fan stuck-rotor Seamless integration with CobraNet-enabled Audia systems CobraNet Interface (16 channels in/16 channels out) CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms, software configurable Dual Ethernet ports for redundancy Selectable 115/230 volt operation Control via RED-1, davinci or third party control systems CE marked, UL listed and RoHS compliant Covered by Biamp Systems five-year warranty 3

audiafusion front panel Setup and Use The Audia software provides the interface for configuring and programming AudiaFUSION. The information supplied by this manual relates to hardware installation, physical connections, and device and channel failover concerns. For more details on software setup, please consult the Audia software Help File. Figure 1. Front Panel alarm activity signal 1 signal 2 status ais power System Indicators The LED indicators on the front panel provide information about the function and operational status of the AudiaFUSION chassis and any installed amplifier modules. Columns one through eight correspond to the eight amplifier module slots. The remaining LEDs correspond to the AudiaFUSION chassis. Figure 2. System Indicators alarm activity signal 1 status signal 2 ais power Channel Indicators Chassis Indicators Channel Indicators Alarm is a two-color LED that illuminates when a channel fault has occurred. Two types of channel faults can be reported, depending on the severity of the problem. Amber indicates a Warning, which means that some aspect of the amplifier module is not performing within normal specification. Audio may still be passing, but if the condition causing the Warning is not corrected, channel failure may occur. Red indicates an Alarm, which means that some aspect of the amplifier module has failed and audio is no longer passing on that channel. Use the Audia software to determine the specific type of channel warning or alarm that has occurred. Activity is a two-color LED that illuminates in green when the channel is configured and actively passing audio and amber when the channel is configured and in standby. Standby only occurs when a channel has been designated as a secondary failover channel in the configuration. 4

audiafusion front panel Signal 1 is a tri-color LED that indicates audio signal presence on the channel. Green indicates that the audio signal level is between -50 dbfs and -3 dbfs, amber indicates a signal level between -3 dbfs and 0 dbfs, and red indicates clipping. Signal 2 has no function at this time and is in place for possible future use. Chassis Indicators Alarm is a two-color LED that illuminates when a chassis fault has occurred. Two types of chassis faults can be reported, depending on the severity of the problem. Amber indicates a Warning, which means that some aspect of the AudiaFUSION chassis is not performing within normal specification. Audio may still be passing, but if the condition causing the Warning is not corrected, chassis failure may occur. Red indicates an Alarm, which means that some aspect of the AudiaFUSION chassis has failed and audio may no longer be passing through the device. Use the Audia software to determine the specific type of chassis warning or alarm that has occurred. Activity is a tri-color LED that illuminates to show the configuration status of the AudiaFUSION unit. If the LED is dark, there is no configuration in the unit. A green LED indicates that the unit is configured, and an amber LED indicates that the unit is configured and in standby. Standby only occurs when a unit has been designated as a secondary failover device in the configuration. A red LED indicates a configuration load failure. Status is a tri-color LED that indicates the health of the AudiaFUSION hardware. A green LED indicates that the unit powered up normally. A flashing amber LED is shown briefly during the power-on self test and should turn solid green upon a successful start up. A red LED indicates that the unit experienced a problem during the power-on self test. AIS has no function at this time and is in place for possible future use. Power is a green LED that illuminates when power is applied to the unit. 5

RISK OF ELECTRICAL SHOCK. DO NOT OPEN. audiafusion rear panel Figure 3. Rear Panel Layout 10 9 8 7 6 5 4 3 2 1 SERIAL CONTROL PORT BIAMP SYSTEMS MODEL AudiaFUSION FUSE 115V FUSE 110-120/220-240V~ 50/60Hz 2400WAT T CAUTION 220-240V: T 12 H, 250V 110-120V: T 20 H, 250V NM-1 Secondary YEL: In use/conductor GRN: Link/Activity CobraNet Connections Only Primary Ethernet Logic I/O 1 2 3 4 LEDs 52SJ Serial Control Port After initial programming and configuration, AudiaFUSION may be controlled by third-party control systems such as AMX or Crestron using the Serial Control Port. External devices may also be controlled or signaled via the Serial Control Port by utilizing Command String blocks within the Audia system design. The port is a DB9 female with pin 2 [RXD], pin 3 [TXD], and pin 5 [GND] connected. AudiaFUSION is an RS-232 DCE device. The default settings are 38400, 8, N, 1, None. The baud rate is adjustable in the Audia software using the Device Maintenance dialog window. The other serial port settings are not adjustable. Please note: There is no hardware flow control. Flow control must be managed in control software. Power Entrance The Power Entrance provides for connection of the appropriate power cord (included with unit). A switch selects the operating voltage for the power supply, 110 120V or 220 240V at 50/60 Hz. NM-1 NM-1 is the Network Module that is included with AudiaFUSION. It provides Ethernet connectivity for programming and control, the CobraNet interface for digital I/O, and logic ports for the device failover functionality. Reset Button Reset button, when held down for 5 seconds, performs a chassis restart. The Status indicator will flash amber during restart and will turn solid green once the process is complete. Logic I/O The Logic I/O connector on the NM-1 facilitates redundant device failover only. It is not a general-purpose contact closure interface. See the Amplifier-to-Amplifier Failover section below. Ethernet AudiaFUSION uses Ethernet for system programming and control. Programming is accomplished using Audia software provided with each unit. Audia software is for PC computers with Windows XP Professional/Vista operating system (required). The PC computer must have a network card installed that supports 10/100Base-T Ethernet. A 10/100Base-T Ethernet switch (not repeater hub) is required when networking multiple units. AudiaFUSION uses standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. CobraNet The CobraNet interface in AudiaFUSION supports up to 32 simultaneous channels of digital audio (16-in, 16-out) over Fast Ethernet and is compatible with other CobraNet compliant devices. Therefore, AudiaFUSION can be networked with CobraNet products from other manufacturers, expanding the system configuration capabilities. A 10/100Base-T Ethernet switch (not repeater hub) is required when networking multiple units. CobraNet utilizes standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. 6

audiafusion rear panel Please note that CobraNet limits network extensions to seven hops (one-way transmissions) within a network. The primary and secondary CobraNet ports are redundant. Each connector provides two LEDs that indicate Ethernet link and network activity (see table below). Table 1. CobraNet interface status LEDs Left LED Right LED Description None None No data connectivity.. Green None Link established. Green Flashing green Flashing amber Flashing amber Flashing amber Flashing amber Link established and CobraNet activity detected; the unit is acting as a CobraNet performer. Link established and CobraNet activity detected; the unit is operating as a CobraNet conductor. CobraNet fault. Check cabling and configuration for errors. is the Amplifier Module card. An AudiaFUSION chassis can be populated with up to eight cards. Output Use the yellow plug-in barrier strip connectors to connect loudspeaker level outputs. If stranded speaker wire is used, be sure to incorporate all strands into the connector, as stray strands can short to the adjacent terminal or chassis. Do not leave excessive bare wire outside the terminals, as this can lead to shorts. Please note: AudiaFUSION is a powerful amplifier and can damage loudspeakers. Please treat the outputs as you would AC mains power outlets. Always check the loudspeaker s continuous and peak power capabilities and match the amplifier settings accordingly. 7

audiafusion rear panel Amplifier-to-Amplifier Failover AudiaFUSION supports one-to-one automatic device failover in case of fault. Failover is triggered by one of the following conditions: Chassis alarm Channel alarm Loss of power Loss of CobraNet link Loss of Logic I/O Only alarms (e.g., heat sink alarm and channel failure alarm) trigger the failover mechanism. Warnings indicate abnormal system conditions that do not immediately impair audio and do not trigger the failover mechanism. The redundant amplifier must have the same configuration as the primary amplifier (i.e., amplifier module count, watts per module, load configuration). A wire failover link cable must be connected between the primary and the redundant amplifier as shown below. Connect ground to ground and logic 4 of the primary amplifier to logic 3 of the redundant amplifier; connect logic 3 of the primary amplifier to logic 4 of the redundant amplifier. Leave logic 1 and 2 disconnected. Primary AudiaFUSION Logic I/O 1 2 3 4 Logic I/O 1 2 3 4 Redundant AudiaFUSION The redundant amplifier can be wired in parallel to the existing speaker line or connected to a redundant speaker line (see figure below). Relays isolate the output terminals on the secondary AudiaFUSION unit. Relays are normally open. When a configuration is received, relays close on the primary AudiaFUSION and remain open on the redundant AudiaFUSION. On failover, the relay positions are reversed. Parallel Wiring Redundant Wiring Primary AudiaFUSION Primary AudiaFUSION Redundant AudiaFUSION Redundant AudiaFUSION After replacing the faulty amplifier, a power cycle is required to recover from failover. The primary device will resume control after the fail condition is cleared and the unit is re-powered. 8

audiafusion rear panel Channel-to-Channel Failover In addition to entire amplifier failover, AudiaFUSION supports channel-to-channel failover, which is triggered by one of the following conditions: Heat Sink alarm Short Circuit alarm* Channel Failure alarm The wire failover link cable is not required when wiring channel-to-channel failover. Parallel Wiring Redundant Wiring 2 1 2 1 Redundant Primary The redundant channel can be wired in parallel to the existing speaker line (shown above) or connected to a redundant speaker line. The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered. * A Short Circuit alarm will cause failover only if the Persistent Short Circuit Delay time property in the AudiaFUSION is exceeded. 9

audiafusion specifications AudiaFUSION SPECIFICATIONS Inputs: Connection: 20 bits, 48 khz, supported CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms software configurable RJ45 with shielded Ethernet cable (Cat5, Cat5e, Cat6, or Cat7) Overall Dimensions: Height: Width: Depth: Weight: Chassis: card: 5.25 inches (133mm) 19 inches (483mm) 17.25 inches (438mm) 50 lbs. (22.68 kg) 1.25 lbs. (0.57 kg) Environment: Ambient Operating Temperature Range: Ambient intake humidity: Altitude: 32-95 degrees F (0 35 C) 0 100% non-condensing 0 10,000 Feet MSL Compliance: EU Directive 2002/95/EC, RoHS directive UL listed CE marked Power: 110~120 & 220~240 VAC 50/60Hz switch selectable 1. In chassis with fans running normally and unrestricted intake and exhaust Card SPECIFICATIONS Supported Loads: 4Ω 8Ω, 70-Volt Line, or 100-Volt line direct drive 6Ω not shown in GUI Frequency response: 20 Hz 20 khz frequency response flat (+/-1 db) Continuous operation: (in chassis with fans running normally and unrestricted intake and exhaust) 400 W: 1 khz continuous sine wave indefinitely 600 W: 1 khz continuous sine wave for at least 3 minutes 2400 Watt maximum per chassis Distortion and Noise: 0.3% THD+N (20 Hz 20k Hz) all loads and power levels Signal-to-Noise Ratio: (unweighted over 22 Hz 20 khz) 100W 200W 300W 400W 500W 600W Lowimpedance 70V 100V >95 db >100 db >101 db >98 db >101 db >102 db >99 db >101 db >102 db >101 db >102 db >103 db >102 db >102 db >103 db >102 db >103 db >104 db Intermodulation distortion (SMPTE): <0.2% Inter-channel Isolation: DC offset: >75 db (20 Hz-20 khz, full power out) <10mV 10

audiafusion specifications AudiaFUSION Block Diagram NETWORK MODULE AMPLIFIER CARD DSP SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 DSP CLASS D AMPLIFIER DC DETECTION TEMPERATURE CobraNet Audio CobraNet IMPEDANCE MONITORING I V Ethernet Control 10/100 ETHERNET uc Serial I/O Logic I/O RS-232 LOGIC Display FAN CONTROL FAN 1 FAN 2 11

audiafusion specifications AudiaFUSION 115 VAC current draw and heat output To determine the AC line current draw and heat output for the configuration, start by finding the total power for the configured AudiaFUSION chassis. Then refer to the column that describes the type of audio levels the amplifier will be producing. If your configuration uses more amplifier modules than the number shown, add 0.1 amps and 37 BTU for each additional module in the chassis. Configured Output Power (watts) Idle 1/8 power pink noise 1/3 power pink noise Full power sine wave Number of cards* Amps BTU Amps BTU Amps BTU Amps BTU No cards 0 0.3 106 NA NA NA NA NA NA 100 1 0.4 143 0.7 227 0.9 244 1.6 406 200 1 0.4 143 0.8 239 1.3 271 2.7 491 300 1 0.4 143 1.0 251 1.6 300 3.8 590 400 1 0.4 143 1.1 263 2.0 333 4.9 668 500 1 0.4 143 1.3 278 2.4 356 6.1 788 600 1 0.4 143 1.4 297 2.8 413 7.3 910 700 2 0.5 177 1.8 418 3.4 551 8.9 1211 800 2 0.5 177 2.0 430 3.8 577 10.0 1296 900 2 0.5 177 2.1 442 4.2 607 11.1 1395 1000 2 0.5 177 2.2 454 4.5 640 12.2 1473 1100 2 0.5 177 2.4 469 4.9 663 13.4 1592 1200 2 0.5 177 2.5 488 5.3 720 14.5 1715 1300 3 0.5 211 3.0 609 6.0 858 16.2 2015 1400 3 0.5 211 3.1 621 6.3 884 17.3 2101 1500 3 0.5 211 3.2 633 6.7 914 18.4 2199 1600 3 0.5 211 3.4 644 7.1 947 19.5 2278 1700 3 0.5 211 3.5 660 7.4 970 20.6 2397 1800 3 0.5 211 3.7 679 7.8 1026 21.8 2520 1900 4 0.6 246 4.1 800 8.5 1165 23.4* 2820 2000 4 0.6 246 4.2 812 8.8 1191 24.5* 2905 2100 4 0.6 246 4.4 824 9.2 1221 25.7* 3004 2200 4 0.6 246 4.5 835 9.6 1254 26.7* 3083 2300 4 0.6 246 4.7 851 9.9 1276 27.9* 3202 2400 4 0.6 246 4.8 870 10.4 1333 29.1* 3325 For each additional used in a chassis adds 37 BTU or 10 watts to the heat output. For 230 VAC, multiply the current by 0.5. * Burst mode only. Protective limiting will reduce long-term AC current. 585.0271.90B 12

audiafusion warranty BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below. 2 If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems will repair or replace, at BIAMP Systems option, the nonconforming product. As a condition to receiving the benefits of this warranty, you must provide BIAMP Systems with documentation that establishes that you were the original purchaser of the products. Such evidence may consist of your sales receipt from an authorized BIAMP Systems dealer. Transportation and insurance charges to and from the BIAMP Systems factory for warranty service shall be your responsibility. 3. This warranty will be VOID if the serial number has been removed or defaced; or if the product has been altered, subjected to damage, abuse or rental usage, repaired by any person not authorized by BIAMP Systems to make repairs; or installed in any manner that does not comply with BIAMP Systems recommendations. 4. Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives, displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this warranty. All server-based devices are warranted for 3 years only. 5. This warranty is in lieu of all other warranties, expressed or implied. Biamp Systems disclaims all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. 6. The remedies set forth herein shall be the purchaser s sole and exclusive remedies with respect to any defective product. 7. No agent, employee, distributor or dealer of Biamp Systems is authorized to modify this warranty or to make additional warranties on behalf of Biamp Systems. Statements, representations or warranties made by any dealer do not constitute warranties by Biamp Systems. Biamp Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or other person. 8. No action for breach of this warranty may be commenced more than one year after the expiration of this warranty. 9. Biamp systems shall not be liable for special, indirect, incidental, or consequential damages, including lost profits or loss of use arising out of the purchase, sale, or use of the products, even if biamp Systems was advised of the possibility of such damages. 13

DoC DSPA201003 EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. Any alterations to the product not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration. Product Models: I/O Cards: Controls: Audia Series AEC-2HD Logic Box DSP Platforms:, -600C RED-1 AudiaFLEX IP-2, OP-2e Remote Control Bus Hub AudiaFUSION PA-2 Remote Panels; RP-L1, RP-L2, RP-S4 AudiaSOLO TI-2 Select 8, Volume 8, Volume/Select 8 VoIP-2 Voltage Control Box Product Description: Applicable EC Directives: Audio Digital Signal Processors and Control Accessories Applicable Harmonized Standards: LVD Directive (2006/95/EC) Safety EN 60065:2002 EMC Directive (2004/108/EC) Emissions EN 55103-1:1996, Environment E2 Immunity EN 55103-2:1996 R&TTE Directive (1999/5/EC) Terminal Equipment (AudiaFLEX with TI-2 only) Special Considerations for Product Environment or Compliance: Shielded cabling must be used for system connections. RED-1, use only CE marked Power over Ethernet (PoE) device. Technical Documentation File, Location and Contact: Biamp Systems, Inc. phone: (503) 641.7287 9300 S.W. Gemini Drive fax: (503) 626.0281 Beaverton, OR USA 97008 e-mail: biamp@biamp.com Authorized Representative: Larry Copley, Compliance Engineer Authorized Signature: Issued: March, 2010

compliance 15

IMPORTANT SAFETY INSTRUCTIONS 16

IMPORTANT SAFETY INSTRUCTIONS 17

IMPORTANT SAFETY INSTRUCTIONS 18