Common Departures Interconnecting Facilities Requirements

Similar documents
Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Document C0. Use for:

SECTION DISCONNECT SWITCHES

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

RCDs RCBOs MCBs Isolating Switches Switchboards

MiCOM P122C Time-Overcurrent Protection

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

BLUE 3 INSTALLATION GUIDE

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Switchgear FEATURE. Basler Electric Company

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Application Techniques CENTERLINE 2100 Motor Control Centers

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

EDS LONDON 33KV DISTRIBUTION NETWORK DESIGN AND CUSTOMER SUPPLIES

MiCOM P521. Fast Feeder Differential Protection

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

B60 Domestic Voltage Optimisation Unit. Installation Manual

SACE Emax 2 Specification guide

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

CDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

B60 Domestic Voltage Optimisation Unit

TP&N DISTRIBUTION BOARD TYPE B RANGE

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Bulletin Installation of solar photovoltaic systems Rules , , , , and

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

MiCOM P521. Fast feeder differential protection

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

SPM Series Plug-in Surge Protection

Jtec 10kA Miniature Circuit Breaker

Spectra RMS Circuit Breakers with microentelliguard Trip Units

60103 Circuit Breaker

PROCEDURE FOR TESTING P122 THREE PHASE OVERCURRENT & EARTH FAULT PROTECTION RELAY S.E.P TRAINING CENTRE

PRC Coordination of Protection Systems for Performance During Faults

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

NPW800R RETROFITTING. Power and Volatge Protection Relay

MiCOM P111. Three phase and earth fault overcurrent relays

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Electrical Service Change-Tn Neenah

3 Design of the electrical installation protection system

Power systems 5: Protection

(Above 100km Distance) (Streetlight Pole) (Above 100km Distance) (Streetlight Pole)

Memshield Overcurrent Protection Relay (AOR1B)

Standard Development Timeline

Coordination of Surge protection devices

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5

Power-Style QED-2, Series 2 Low Voltage Switchboards

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Miniature Circuit-Breaker IEC Series 8562

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Substation Automation Products. Line differential protection RED670 Relion 670 series

Electrical Demand Specification (Reference SOP: )

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Miniature Circuit Breakers for Railway Applications

POWER GRID AUTOMATION. Pág.. n. RMU Automation

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

Surge Protective Device

Masterpact NW Restricted Earth Fault Protection

Section 4 Ground-Fault Protection Devices

User Manual. AQ-F215 Simulator

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

VAMP 221. Table of Contents

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

B60 Domestic Voltage Optimisation Unit. Installation Manual

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Instructions Order No. 3ZX1812-0WN60-0AC0 /

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Powerpact 4 panelboards Panelboards and incoming devices Panelboards

Remote communication options include IEC Ethernet communications or Modbus (RS485).

Products Portfolio. Pole mounted Vacuum Recloser

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards.

Power System Protection Training

SECTION DISTRIBUTION SWITCHBOARDS

4. CIRCUIT BREAKERS. Functional Emergency Switching

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

1510 MOTOR CONTROLLERS

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

QUICK REFERENCE PRICE GUIDE JUNE 2016

Residual Current Devices drcm Digital

Zone-Selective Interlocking Field Testing and Commissioning

PRC System Protection Coordination Supplementary Reference

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

11 kv Indoor Switchgear - SCADA Controlled

Description. Installation. Power supply

3- and 4-pole switching in UPS installation

Transcription:

Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low voltage main switch and interconnecting facilities requirements. We hope you can avoid these departures when you prepare your installation for connection of supply. We hope you will find the information of this e-rew Express useful and handy. If you have any suggestion, please send an email to us at mail@hec.com.hk or contact our Customer Installation Section at 2887 3455 so that we can further improve our service. Common Departures on Customer Low Voltage Main Switch and Interconnecting Facilities Requirements 1. Main Incomers i. Protection Scheme The time-current curve of overcurrent protection of customer main incomer directly connected to transformer cannot grade with HK Electric infeed protection. The type and setting of customer main incomer s protective devices shall be graded properly with HK Electric infeed protection.

ii. Switches Directly Connected to Transformer Main Incomer Essential Main Switch 35kA 45kA The short circuit breaking capacity of the switch directly connected to transformer is inadequate. Short circuit breaking capacity of the switch directly connected to transformer shall exceed 40kA. The switch directly connected transformer shall not be of fixed type. to Draw-out type or plug-in type circuit breaker shall be used. 2

iii. Undervoltage Protection Undervoltage Protective Device Undervoltage Protective Device Undervoltage protective devices should not be installed at main switches or switches affecting more than one customer / equipment. Undervoltage protective devices should be installed at the load side only in order to avoid unnecessary supply interruption to other equipment / customers. 2. Customer Main Switch i. Main Switch Position A customer main switch shall not be installed after HK Electric s meter. A customer main switch shall be installed and connected immediately before HK Electric s meter. 3

ii. Single Phase Installation A single pole switch cannot be used as a main switch for single phase installation. A main switch for single phase installation shall be of double-pole type interrupting live and neutral. iii. 3-phase Installation Neutral Link Neutral link in the neutral conductor of a 3-pole main switch for 3-phase installation has not been provided. A main switch for 3-phase installation shall be of 4-pole or TPN switch. If 3-pole linked switch or circuit breaker is used, a link shall be inserted in the neutral conductor and securely fixed by bolts or screws. iv. Temporary Installation or Overhead Line Supply A MCB shall not be used as the main switch for the installation which is supplied from an overhead line installation or for temporary installation. A RCD shall be used as the main switch for the installation which is supplied from an overhead line installation or for temporary installation. 4

3. Riser Switch Earth fault relay associated with protection C.T.s could be used to achieve automatic disconnection within 5 seconds during an earth fault. 4. An instantaneous trip RCD should not be used as riser switch or cutout of multi- customer premises. Interconnecting Circuit Breakers Between Two or More Supply Sources i. Section Switch Overcurrent protection of the section switch has not been provided. With Overcurrent Protection The section switch shall be provided with proper overcurrent protection. ii. Changeover Switch A 3-pole changeover switch shall not be used for interconnecting the normal and standby sources. 5 A mechanically and electrically interlocked 4-pole changeover switch should be used for interconnecting the normal and standby sources to ensure that neutral unbalance and fault currents return to the correct source of supply.

iii. LV Service Cables No interconnecting facilities between HK Electric s LV service cables are allowed. We are pleased to provide advisory services to REC/REW regarding the customer low voltage main switch and interconnecting facilities arrangement. Please provide us with the schematicc wiring diagram. We will study and feedback our comment or suggestion to you. 6