DOR6. Components All functions and indications are on the front of the module. Characteristics

Priva Blue ID system overview

Priva Blue ID C-Line Mix input/output module MX34

Priva Blue ID C-Line system overview

Priva Blue ID C4 Controller with manual override C-MX34m

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

RXTH DUAL ROOM SENSOR / SWITCH

Island bus expansion module

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

AB Axis Industries. Use

iologik 4000 Series (M) Modules

ECLYPSE Communication Modules

RТTH DUAL ROOM SWITCH

RXTP ROOM TEMPERATURE

ECLYPSE Communication Modules

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

PSI-MODEM-SHDSL/SERIAL Copper Extender

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

General Specifications

See instructions to download and install the latest version of LinkBoxLON and the user's manual at


Signal Doublers. VariTrans A 20300

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Model Number Structure

DAWN Mini ADAQ TC20 Details

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MODEL: R2K-1 SEN TRONIC AG. R2K Series

IntesisBox Modbus Server Panasonic

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Resistance measuring module

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

Mini Energy Web Server

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Power supply module, bus connection module

Ethernet. RJ45 Copper Ports

EXOcompact. Third generation freely programmable controllers

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Operating instructions. Switching amplifier DN0210 DN / / 2015

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

20 General technical data XI/ON

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

NX integrated safety System configuration. Integrated safety into machine automation

Electronic timer CT-ERD.12

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Thread length (overall length) material

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

Model Number Structure

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

CliQ II Buffer Module 24V 40A / DRB-24V040ABN

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Advantages of a Full Featured 700 Series Relay

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

E1 Plus Electronic Overload Relay

iothinx 4500 Series (45MR) Modules

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

em4 Accessories Digital expansions

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Compact, fanless, vibration-proof computers for rolling stock applications. Features and Benefits. Certifications

Ethernet to Digital I/O +RS232 +Switch

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TM3AI4 module TM3-4 analog inputs

Digital input modules

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Faults on the system Proximity switch connection technology:

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

Bluetooth to Serial Converter TOP FRONT. Click 421

Model Number Structure

RCMB20/RCMB Series

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Features and Benefits. Certifications

BACnet/IP Web Interface

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Transcription:

Blue ID Communication module RS485 Modular design An Blue ID Communication module RS485 provides the system with two RS485 ports for serial communication and is used to connect field bus devices. Characteristics two RS485 ports for serial communication ports electrically isolated from system neutral ports electrically isolated from each other both ports have an A, B and 0 connection 24 V system power supply monitoring clear labelling of ports LED for communication status per port LED for status of module Blue ID Lifeline text card for identification of ports All communication modules (A) have the same base (B). You simply click the base with module onto the DIN rail (C). Hot swappable A module can easily be removed from and placed back in the base without tools. This can be done live (hot swappable). Electrical isolation The module's ports are electrically isolated from the system neutral. In addition the RS485 ports are electrically isolated from each other. 1

Clear indication Legend A B C D E F Blue ID Lifeline LED for status of port RS485-1 port RS485-1 LED for status of port RS485-2 port RS485-2 LED for status of module Blue ID Lifeline The modules are equipped with blue LEDs. Together, these LEDs form the Blue ID Lifeline. If the blue line is continuously on, the modules and bases are in the correct place according to the configuration in TC Engineer. LEDs for status of ports Per port, an LED clearly indicates the port's status. The LED is continuously green when the module is working. In other situations, the LED flashes or is off. In the event of a communication error, the LED is red as long as the error is present. LED for status of module The LED shows the status of the module. The LED is on continuously when the module is working correctly. If not, and in special circumstances, the LED flashes. Connection examples Making a two-wire connection Termination and connecting base circuit 2

Specifications module General Module article description Module article number Base article description Base article number Number of RS485 ports Dimensions (XYZ) Weight Maximum power consumption MTBF¹ Construction Mounting of base Material Blue ID Communication module RS485 5040001 Blue ID SC Communication base 5040101 2 161.5 x 40 x 100.2 mm (6.36 x 1.57 x 3.94 inches) module: 110 grams base: 120 grams 2.0 W module: 4,380,000 hours base: 8,760,000 hours removable module on a base clicks onto DIN rail mixture of polycarbonate and ABS ¹ The MTBF is calculated according to the Telcordia SR-332 standard Issue 2 under the following conditions: - ambient temperature: 35 50 C - supply voltage: 24 VDC - time in operation per day: 24 hours - reliability level: 60 % 3

Communication Standard used Bus load Bias resistance Baud rates Other parameters TIA/EIA-485 1/2 Unit Load 47 kω 1k2, 2k4, 4k8, 9k6, 19k2, 38k4, 57k6, 76k8 and 115k2 bps number of data bits: 7, parity: even, odd number of data bits: 8, parity: none, even, odd number of stop bits: 1 or 2 Internal termination and bias circuit with a baud rates above 38400 bps the network must be terminated at both ends and be equipped with a bias circuit termination and a bias circuit are not required for other baud rates Functional isolation of voltage between the ports mutually, and in relation to system neutral Accuracy of internal temperature measurement Protection of ports Cable type required Cross section Maximum cable length Connector type (supplied 2x) 240 V ± 2 C protected against incorrect connection of ± 30 VDC and 30 VAC twisted pair 0.2 2.5 mm² (without ferrule connector) 0.25 2.5 mm² (with ferrule connector) 500 m three-pin pluggable screw connector with A, B and 0 connection Indication Blue ID Lifeline red-green LEDs for status of ports green LED for status of module General specifications for controller, modules and bases Housing IP code Flammability class Recycle code Colour IP30 (NEN-EN-IEC 60529) FV-0 7 release surfaces of module and DIN rail release: blue (RAL5013) other parts: white (RAL9003) Mounting and connection Installation in control cabinet, accessible to authorised personnel only open device, to be used in an environment with a permitted pollution factor of 2 can be clicked onto mounting plate on horizontally or vertically positioned DIN rail Maximum width of I/O modules, bus extension modules and controller Environment Permitted temperature inside control cabinet during normal operation Permitted temperature inside control cabinet during transport and storage Permitted relative ambient humidity Shock and vibration resistance Installation category Permitted ambient pollution Note: The controller, SC module and SN module may only be mounted horizontally. 20 m 0 50 ºC 0 70 ºC 10 % - 95 % (non-condensing) IEC61131-2 II pollution degree 2 4

Legislation and standards Canada / USA Europe CSA/UL approved, in compliance with: UL 61010-1:2004 (measurement and control equipment) CSA C22.2 No 61010-1-04 (measurement and control equipment) ICES-003 Issue 4 Class B CE mark, in compliance with: Low voltage directive 2006/95/CE EMC directive 2004/108/EC RoHS directive 2011/65/EU in compliance with harmonised standard IEC 61010-1:2010 (3rd Edition) in compliance with WEEE Directive 2002/96/EC International The Blue ID S10 Controller is BTL registered at BACnet International. The Blue ID S10 Controller is BACnet certified in accordance with ISO 16484-5/6. Priva is a member of the BACnet Interest Group Europe. 5

Europe Office: UK Office: Canada Office: Your Priva partner: Priva Zijlweg 3 P.O. Box 18 2678 ZG De Lier The Netherlands T +31 174 522 600 F +31 174 522 700 www.priva.nl sales.building@priva.nl Priva Zijlweg 3 PO Box 18 2678 ZG De Lier The Netherlands T +44 (0)1923 813 480 F +44 (0)1923 813 499 www.priva.co.uk sales@priva.co.uk Priva North America Inc. 3468 South Service Road Vineland Station Ontario LOR 2E0 Canada T +1(905) 562-7351 F +1(905) 562-7717 www.priva.ca contact.priva@priva.ca 5201113_01.002_07-2013