Daker DK Plus UPS RACK-TOWER UPS. from 1 to 10 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Similar documents
UPS. ARCHIMOD UPS MODULAR THREE-PHASE from 20 to 120kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

UPS Emergency Bed Power Unit

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

KEOR HP. 3 PHASE UPS from 100 to 800 kva

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

CPS kVA TRIFASE EN50171

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

Sentinel Dual High Power

Socomec Netys PR RT U P S TOWER / RACK MOUNT

DSP Control. 0.9 Output Power Factor. Wide Input Range. High Efficiency Mode(ECO) Frequency Converter Mode. Input THDi<5% Output THDv<2%

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

Uninterruptible Power Supplies

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

AP 160 N. UPS COMPACT Rack tower convertible 1-10 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

SmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Premium Online Series

EP Series II UPS 230 V

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

GAMATRONIC, A SolarEdge Division.

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

SMARTONLINE E3 UPS SYSTEMS

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

The Power of Modularity

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Schneider Electric Easy UPS 3S

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

Business continuity made easy

SmartOnline 208/240 & 120V 8kVA 5.6kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10kVA

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

550 and 750 VA a multi-socket UPS to make all your connections easier. Protection adapted to meet all your needs

APC Easy UPS 1 Ph Online Extended Runtime Models

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

SmartOnline Expandable Rack / Tower UPS System On-line, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Critical Power 2017 Catalogue

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Uninterruptible Power Supplies

Advanced technology for superior protection. True online operation load is isolated from the AC power : Quick setup: Emergency Power Off (EPO):

SmartOnline 120V 1.5kVA 1.35kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Oversize Internal Batteries, Network Card Slot, LCD, USB, DB9

the Centric 300 An advanced modular UPS up to 1800kVA/kW

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

SmartOnline 208/240V 10kVA 9kW Double- Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

Schneider Electric Easy UPS 3S

SmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

MAJOR VA Power Inverter

Infinisolar V Hybrid-On Grid Inverter with Energy Storage

Schneider Electric Easy UPS 1 Ph Online

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

Product Specifications

SmartOnline 208/230V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, SNMP Card Option, LCD, USB, DB9, ENERGY STAR

Model #: SU5000RT4UHV

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

Est FlexiPower Maxi UPS FPX Maxi kVA

GE Critical Power. Single Phase UPS Overview. 1 Gabriele Andrighetti

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Power Solutions Catalogue

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

UPS MANAGEMENT SYSTEMS UPS SUPERVISION AND CONTROL SYSTEMS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial

PowerWAVE (6-10kVA) Technical Specification

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

MP7. Uninterruptible Power Supply

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on

Transcription:

Daker DK Plus UPS RACK-TOWER UPS from 1 to 10 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Daker DK Plus On Line double conversion UPS that can be used in both tower and rack configurations. CONVERTIBLE SINGLE PHASE UPS The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on the LCD screen. The models from 5 to 10 kva have power factor 1 with an efficiency of up to 94%. Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging. Reversible screen With the reversible screen, the Daker DK Plus UPS can be used in both tower and 19" rack configuration. WWW.UPS.LEGRAND.COM

DAKER DK PLUS UPS - On-line double conversion VFI 3 101 74 3 101 77 3 106 64 The main parameters of the UPS, including the battery charge level and faults, are displayed on the LCD screen on the front panel. The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely, communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur. The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels. If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance. Pack Cat. Nos. Convertible UPS with batteries Nominal power (VA) Active power (W) Backup time (min) Weight (kg) 1 3 101 70 1000 900 9 16 1 3 101 71 2000 1800 10 29,5 1 3 101 72 3000 2700 7 30 1 3 101 73 5000 5000 6 60 1 3 101 74 6000 6000 5 60 Pack Cat. Nos. Battery cabinet (empty) Description 1 3 106 65 Battery cabinet for 3 101 70 1 3 106 66 Battery cabinet for 3 101 71 1 3 106 67 Battery cabinet for 3 101 72 1 3 106 68 Battery cabinet for 3 101 73-3 101 74-3 101 75-3 101 76 1 3 106 69 Battery cabinet for 3 101 77-3 101 78 Convertible UPS without batteries Nominal power (VA) Active power (W) Phase configuration Weight (kg) 1 3 101 75 5000 5000-25 1 3 101 76 6000 6000-25 1 3 101 77 10000 10000-26 1 3 101 78* 10000 9000-28 * 3-1 version Battery cabinet (with batteries) Description 1 3 106 60 Battery cabinet for 3 101 70 1 3 106 61 Battery cabinet for 3 101 71 1 3 106 62 Battery cabinet for 3 101 72 1 3 106 63 Battery cabinet for 3 101 73-3 101 74-3 101 75-3 101 76 1 3 106 64 Battery cabinet for 3 101 77-3 101 78 Accessories Description 1 3 109 52 Rack support bracket kit 1 3 109 53 External manual Bypass for 3 101 70-3 101 71-3 101 72 1 3 109 63 External manual Bypass for 3 101 73-3 101 74-3 101 75-3 101 76-3 101 77 1 3 109 59 Additional charger for 3 101 70 1 3 109 61 Additional charger for 3 101 71-3 101 72 1 3 109 54 Additional charger for 3 101 73-3 101 74-3 101 75-3 101 76-3 101 77-3 101 78 1 3 109 69 Dry contact card New product codes in red. NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment.

DAKER DK PLUS UPS - On-line double conversion VFI n Caratteristiche General characteristics 3 101 70 3 101 71 3 101 72 3 101 73 3 101 75 3 101 74 3 101 76 3 101 77 3 101 78 Nominal power (VA) 1000 2000 3000 5000 6000 10000 10000 Active power (W) 900 1800 2700 5000 6000 10000 9000 Technology On-line double conversion VFI-SS-111 Waveform Sinusoidal Architecture Convertible tower and 19" rack Input characteristics Input voltage 230 V 380V 3P+N Input frequency 50-60 Hz ± 5% autosensing Input voltage range 176V - 280V at full load 305V - 485V THD of input current < 3% Input power factor > 0,99 > 0,9 Output characteristics Output voltage 230 V ± 1% Output frequency (nominal) 50/60 Hz (configurable via LCD panel) +/- 0.1% Efficiency up to 90% up to 91% up to 92% up to 94% up to 90% Peak factor 1:3 THD of output voltage < 3% with linear load Output voltage tolerance ± 1% Internal automatic bypass included External maintenance bypass optional optional optional optional optional optional optional optional - Batteries Backup time extension Yes Backup time (min) 9 10 7 6-5 - - - Communication and management Screen and signalling Four buttons and five LEDs for real-time control of the status and the main parameters of the UPS Communication ports Remote control Connector for network interface Back feed protection Emergency power off (EPO) Mechanical characteristics Dimensions (H x W x D) (mm) 440 x 88 (2U) x 405 440 x 88 (2U) x 600 RS232 and USB serial ports 440x196 (4U)x680 Available SNMP yes yes 440x88 (2U)x680 440x196 (4U)x680 440x88 (2U)x680 RS232 serial ports 440x132 (3U) x680 Net weight (kg) 16 29,5 30 60 25* 60 25 26 28 Dimensions of battery cabinet H x W x D (mm) 440x196 (4U)x425 440 x 88 (2U) x 600-440 x 88 (2U) x 680-440 x 88 (2U) x 680 440 x 132 (3U) x 680 Ambient conditions Operating temperature ( C) 0 40 C Protection index IP 21 Relative humidity (%) 20 to 80% Noise at 1 m (dba) < 50 Heat dissipation (BTU/h) 490 654 818 892 1300 1636 Certifications Reference product standards EN 62040-1, EN 62040-2, EN 62040-3 NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment.

DAKER DK PLUS Long backup time table Model Power Backup time Dimensions and number of cabinets H x W x D (mm) Cat. Nos. 9 440 x 88 x 405 3 101 70 1000 VA 1h 27 440 x 88 x 405 + 440 x 196 x 425 3 101 70 + 3 106 60 3h 440 x 88 x 405 + 440 x 196 x 425 (x2) 3 101 70 + 3 106 60 (x2) 10 440 x 88 x 600 3 101 71 2000 VA 45 440 x 88 x 600 (x2) 3 101 71 + 3 106 61 1h 28 440 x 88 x 600 (x3) 3 101 71 + 3 106 61 (x2) 7 440 x 88 x 600 3 101 72 3000 VA 31 440 x 88 x 600 (x2) 3 101 72 + 3 106 62 58 440 x 88 x 600 (x3) 3 101 72 + 3 106 62 (x2) 1h 29 440 x 88 x 600 (x4) 3 101 72 + 3 106 62 (x3) Daker DK Plus Daker DK Plus 3-1 5000 VA 6000 VA 10000 VA 10000 VA 6 440 x 88 x 680 + 440 x 88 x 680 3 101 75 + 3 106 63 19 440 x 88 x 680 + 440 x 88 x 680 (x2) 3 101 75 + 3 106 63 (x2) 32 440 x 88 x 680 + 440 x 88 x 680 (x3) 3 101 75 + 3 106 63 (x3) 50 440 x 88 x 680 + 440 x 88 x 680 (x4) 3 101 75 + 3 106 63 (x4) 5 440 x 88 x 680 + 440 x 88 x 680 3 101 76 + 3 106 63 15 440 x 88 x 680 + 440 x 88 x 680 (x2) 3 101 76 + 3 106 63 (x2) 30 440 x 88 x 680 + 440 x 88 x 680 (x3) 3 101 76 + 3 106 63 (x3) 45 440 x 88 x 680 + 440 x 88 x 680 (x4) 3 101 76 + 3 106 63 (x4) 6 440 x 132 x 680 + 440 x 132 x 680 3 101 77 + 3 106 64 17 440 x 132 x 680 + 440 x 132 x 680 (x2) 3 101 77 + 3 106 64 (x2) 28 440 x 132 x 680 + 440 x 132 x 680 (x3) 3 101 77 + 3 106 64 (x3) 41 440 x 132 x 680 + 440 x 132 x 680 (x4) 3 101 77 + 3 106 64 (x4) 54 440 x 132 x 680 + 440 x 132 x 680 (x5) 3 101 77 + 3 106 64 (x5) 7 440 x 132 x 680 + 440 x 132 x 680 3 101 78 + 3 106 64 19 440 x 132 x 680 + 440 x 132 x 680 (x2) 3 101 78 + 3 106 64 (x2) 31 440 x 132 x 680 + 440 x 132 x 680 (x3) 3 101 78 + 3 106 64 (x3) 45 440 x 132 x 680 + 440 x 132 x 680 (x4) 3 101 78 + 3 106 64 (x4) 59 440 x 132 x 680 + 440 x 132 x 680 (x5) 3 101 78 + 3 106 64 (x5) NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment. n Configurations 1000 VA 2 cabinet L 2U + 4U 2000 VA 2 cabinet L 2U + 2U 3000 VA 3 cabinet L 2U +2U + 2U 6000 VA 2 cabinet L 2U + 2U 10000 VA 2 cabinet L 3U + 3U TOWER version 1000 VA 2 cabinet H 2U + 4U (294mm) 2000 VA 2 cabinet H 2U + 2U (196mm) 3000 VA 3 cabinet H 2U + 2U + 2U (294mm) 6000 VA 2 cabinet H 2U + 2U (196 mm) 10000 VA 2 cabinet H 3U + 3U (294mm) RACK version WWW.UPS.LEGRAND.COM

World Headquarters and International Department 87045 Limoges Cedex - France : + 33 (0) 5 55 06 87 87 Fax : + 33 (0) 5 55 06 74 55 AD-EXLG/UPS-DP17B/GB - 10/2017 In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the Company.