Industrial 2-port RS422/485 Modbus Gateway IMG-120T

Similar documents
Industrial 1-port RS422/485 Modbus Gateway IMG-110T

Industrial 1-port RS422/485 Modbus Gateway

Industrial 2-port RS422/485 Modbus Gateway

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter

MGate 5105-MB-EIP Series

Features and Benefits. Certifications

Modbus Gateway User's Manual ADM-5850G

Industrial Protocol Gateway

IntesisBox Modbus Server - Honeywell XLS 80

PG5901 Series. Industrial Protocol Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual

IntesisBox Modbus Server - BACnet/IP Client

Industrial Protocol Gateway

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Industrial Gateway Solutions

Industrial Protocol Gateway

MW5501C Series MW5502C Series. 1 or 2-Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

MGate MB3000 Modbus Gateway User Manual

MGate 5102-PBM-PN Series

MGate MB3000 Modbus Gateway User s Manual

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

NetCom Plus 113. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

MGate MB3000 Modbus Gateway User s Manual

iologik E1200H Series

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Tel: Fax:

Industrial Serial Device Server

1-Port Serial-to-IP Ethernet Device Server - RS232 - DIN Rail Mountable

NetCom Plus 413 POE. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

MGate 4101-MB-PBS Series

NetCom Plus 211. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

Power Serial Device Server

Industrial 4G LTE Cellular Gateway with 4-Port 10/100TX (2-SIM Card Slot, 2 RS232, 1 RS485, DI/DO, GPS, -20~70 degrees C)

NetCom 413 PRO. Contact Online. More Pictures. Klick on the thumbnails for the large picture. Overview

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

IntesisBox Modbus Server - LON

NetCom Plus 811 POE. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USR-TCP Hard version: V2.0 File version: V

Ethernet to RS-232/485 Gateway

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

TRP-C37M User s Manual

DT Desktop Series

Modbus Server SIEMENS Algorex (printer port)

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

Operation Manual EX-9133C-2-MTCP

IntesisBox Modbus Server Fidelio IP

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

TRP-C37M User s Manual

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

USER MANUAL FOR GS100/GS1003G

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

Real/Virtual COM. JetPort Commander

HART Products. ICP Electronics Australia Pty Ltd Overview P 6-1

Industrial 8-Port 10/100TX Compact Ethernet Switch

Modbus TCP/RTU Gateway

Serial Device Server Overview. Serial Device Servers. Modbus Gateways. Programmable Device Servers. Serial to USB Converters

MESR9xx. Vlinx Industrial MODBUS Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

SunSpec Reference Architecture SunSpec CEA 2045 Inverter Adaptor

Features and Benefits. Certifications

NetCom Plus 111 (NetCom 111)

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

IntesisBox Modbus Server Siemens Synova FC330A

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Industrial 4G LTE Cellular Gateway with 4-Port 10/100TX (2 SIM Card Slots, 2 RS232, 1 RS485, DI/DO, -20~70 degrees C)

Modbus TCP / RTU Gateway

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

IntesisBox BACnet IP Server - M-Bus

TRP-C37 User s Manual

Operation Manual of EX9132CST-Series

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

1 port RS-232 Device Server

OnCell G3150A-LTE Series

Feature and Benefits. Certifications

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

PX Serial - Quick Start Guide

NetCom Plus 113 (NetCom 113, NetCom 113 PRO)

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

tgw-700 Series User Manual

Features and Benefits. SNMP MIB-II for network management. Certifications

ATK3 I/O Module (Modbus Slave)

Transcription:

Industrial 2-port RS422/485 Modbus Gateway IMG-120T

u Product Positioning Presentation Outlines u Applications u Product Overview u Comparison u Product Benefits u Product Features 2 / 42

Product Positioning

Modes of Application Overview Factory Building Transportation 4 / 42

PLANET Serial Products Family Industrial (-40-75 degrees C) IMG-110T - 1 x RS422/485 COM port - RJ45 Fast Ethernet interface - 9-48V DC input IMG-120T - 2 x RS422/485 COM port - RJ45 Fast Ethernet interface - 9-48V DC input Industrial (-10-60 degrees C) ICS-210x Series (ICS-2100/ICS-2102/ICS-2102S15/ICS-2105A) - RS232/422/485 over Fast Ethernet - RJ45/SC/SFP Fast Ethernet interfaces -12-48V DC/24V AC input Standard (0-50 degrees C) ICS-10x Series (ICS-100/ICS-102/ICS-102S15/ICS-105A) - RS232/422/485 over Fast Ethernet - RJ45/SC/SFP Fast Ethernet interfaces - 5V DC input Planning Developing New Phase-in Available Serial over Ethernet Media Converter Modbus Gateway 5 / 42

Product Overview

Product Overview u About Modbus Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controllers (PLCs). Simple and robust, it has since become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices. The main reasons for the use of Modbus in the industrial environment are: 1: Developed with industrial applications in mind. 2: Openly published and royalty-free. 3: Easy to deploy and maintain. 4: Moves raw bits or words without placing many restrictions on vendors. Modbus enables communication among many devices connected to the same network, for example, a system that measures temperature and humidity, and communicates the results to a computer. Modbus is often used to connect a supervisory computer with a Remote Terminal Unit (RTU) in Supervisory Control And Data Acquisition (SCADA) systems. The development and update of Modbus protocols has been managed by the Modbus Organization since April 2004 when Schneider Electric transferred rights to that organization. The Modbus Organization is an association of users and suppliers of Modbus-compliant devices that seek to drive the adoption and evolution of Modbus. 7 / 42

Product Overview u About Modbus Protocol Versions Versions of the Modbus protocol exist for serial port, and for Ethernet and other protocols that support the Internet protocol suite. There are many variants of Modbus protocols: Modbus RTU This is used in serial communication and makes use of a compact, binary representation of the data for protocol communication. Modbus ASCII This is used in serial communication and makes use of ASCII characters for protocol communication. Modbus TCP/IP or Modbus TCP This is a Modbus variant used for communications over TCP/IP networks, connecting over Port 502. It does not require a checksum calculation, as lower layers already provide checksum protection. Modbus over TCP/IP or Modbus over TCP or Modbus RTU/IP This is a Modbus variant that differs from Modbus TCP in that a checksum is included in the payload as with Modbus RTU. 8 / 42

Product Overview u About Modbus Protocol Versions Modbus over UDP Some have experimented with using Modbus over UDP on IP networks, which remove the overheads required for TCP. Modbus Plus (Modbus+, MB+ or MBP) Modbus Plus is proprietary to Schneider Electric and unlike the other variants, it supports peer-to-peer communications between multiple masters. Pemex Modbus This is an extension of standard Modbus with support for historical and flow data. It was designed for the Pemex oil and gas company for use in process control and never gained widespread adoption. Enron Modbus This is another extension of standard Modbus developed by Enron Corporation with support for 32-bit integer and floating-point variables, and historical and flow data. 9 / 42

Product Overview u What is Industrial Modbus RTU/ASCII Network Integration? Modbus TCP/IP Ethernet RS422/RS485 Modbus TCP/IP Serial Cable Industrial Equipment SCADA Workstation / PC 10/100TX UTP RTU Master ASCII Master RTU Slave ASCII Slave 16 Master TCP Connections 32 Slave TCP Connections 10 / 42

Product Overview u What is Industrial Modbus RTU/ASCII Network Integration? 100m Distance Extension Modbus TCP/IP 10/100TX UTP SCADA Workstation / PC 1m ~ 20m Modbus RTU/ ASCII Serial Cable Industrial Equipments Conversion Bridge between Modbus TCP/IP and Modbus RTU/ASCII Protocol IMG-120T 11 / 42

Product Overview Range of Applications Modbus SCADA Touch Panel HMI Modbus Touch Screen Room Controller Programmable Logic Controller (PLC) Modbus Electricity Meter Power Meter 12 / 42

Product Overview u Front Panel ü LED Indication for the serial transmit data (TX1/ TX2) ü LED Indication for the serial receive data (RX1/ RX2) ü LED Indication for system power, Fast Ethernet Port LNK/ACT ü PIN Definition for the RS422/RS485 COM Interface 13 / 42

Product Overview u Mechanical Drawing ü 2-contact terminal block for the DC 9-48V power input ü DIP switch for resetting to default ü RJ45 port for 10/100BASE-TX ü Wall-mount kit ü 10-contact terminal block for the RS422/RS485 COM Interface 14 / 42

Product Benefits

u As required by customers Product Benefits Economical RS422/RS485 to 10/100TX Integration Solution Conversion Bridge between Modbus TCP/IP & Modbus RTU/ASCII Protocols Master Mode for 32 Slave TCP Connections Slave Mode for 16 TCP Master Connections IMG-120T Industrial 4.0 Higher Flexibility Cost Effectiveness 16 / 42

Product Features

Product Key Features -40 to 75 4-wire RS422 degrees C & 2-wire Operating RS485 Temperature Terminal Blocks 1KV Surge Protection For Serial Port IMG-120T 300bps~ 115200bps Baud Rate Options Wall-mount IP40 Metal Case IP Address & MAC Address Filtering Function Built-in IP-based Web and Telnet Interfaces 18 / 42

Product Features u Hardware ü 2 RS422/RS485 with 5-contact terminal block 2-wire RS485. 4-wire RS422. ü 1 10/100BASE-TX TP RJ45 interface ü DIP switch for resetting to default ü LED Indicators for system, network and RS422/RS485 interface diagnostics ü Wall-mount type IP40 metal case ü FCC Part 15 Class B, CE ü IEEE 802.3/802.3u Fast Ethernet standard ü Dimensions: 69 x 100 x 22 mm (W x D x H) ü Weight: 238g 19 / 42

Product Features u Hardware ü 1KV Surge Protection for RS422/485 serial port ü 300bps~115200bps baud rate (data rate) ü 7 & 8 data bits ü Odd/Even/None/Space/Mark parity type ü 1 & 2 stop bit ü Hardware & None flow control ü Signals: 2-wire RS485:Data A (+), GND, Data B (-) 4-wire RS422: Tx+, Tx-, GND, Rx+, Rx- ü Distance: RS422/RS485 for 20m transfer distance 20 / 42

u Industrial Conformance Product Features ü 9~48V DC power input designed with 2-contact terminal block ü -40 to 75 degrees operating temperature ü Wall-mount IP40 metal case ü Stability tests include: IEC60068-2-32 (free fall) IEC60068-2-27 (shock) IEC60068-2-6 (vibration) 21 / 42

u Serial Operation Modes ü RTU Master and RTU Slave Product Features ü ASCII Master and ASCII Slave ü Master mode supports 32 slave TCP connection requests ü Slave mode supports 16 TCP master connections u Management Functions ü Built-in IP-based Web interface and telnet interface for remote management ü Modbus TCP, Modbus RTU, Modbus ASCII, IP, ARP, DHCP and DNS ü Firmware upgrade/configuration backup and restore via HTTP Protocol 22 / 42

Product Features u User-friendly Web Management Interface -- COM Settings 23 / 42

Product Features u User-friendly Web Management Interface -- Slave ID 24 / 42

Product Features u User-friendly Web Management Interface -- System File 25 / 42

Product Features u Access Control ü IP address and MAC address filtering function ü Users level management u Management Utilities ü PLANET Modbus Gateway utility for finding client device on the network and related IP subnet address setting to be reset to factory default function ü PLANET Smart Discovery utility automatically finds the client devices on the network 26 / 42

Product Features u PLANET Modbus Gateway Utility 27 / 42

Product Features u User-friendly Web Management Interface -- Device Security 28 / 42

Product Features u User-friendly Web Management Interface -- IP Filtering 29 / 42

Product Features u User-friendly Web Management Interface -- MAC Filtering 30 / 42

Product Features u User-friendly Web Management Interface User Management 31 / 42

Applications

Applications 33 / 42

Applications 34 / 42

Applications 35 / 42

Comparison

Comparison Model PLANET IMG-120T MOXA Mgate MB3280 Features RJ45 Port One 10/100BASE-TX, auto MDI/MDIX One 10/100BASE-TX, auto MDI/MDIX Serial Port 5-contact terminal block RS422/RS485x 2 DB9 male RS232/RS422/RS485 x 2 Baud Rate (Data Rate) 300bps to 115200bps 50bps to 921.6kbps Operation Mode Modbus RTU/ASCII Master & Slave Modbus RTU/ASCII Master & Slave Management Interface Remote IP-based Web/Telnet Remote IP-based Web/Telnet Utility Modbus Gateway Utility/Discovery Utility MGate Management Utility Power Input Connector 2-contact terminal block (DC 9-48V) DC jack & terminal block for 12-48V DC Enclosure & Operating Temperature IP 40 metal case, -40~75 degrees C IP 30 metal case, 0~60 degrees C Price $ $ (349) MSRP 37 / 42