User Guide. Conductivity Meter. Model EC210

Similar documents
ph/orp Meter SD Card real-time Datalogger

Indoor Air Quality Meter/Datalogger

12-Channel Thermocouple Datalogger

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

User's Guide. Hot Wire Thermo-Anemometer. Model

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Heavy Duty Vibration Meter

USER GUIDE. AC/DC Magnetic Meter. Model MF100

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

User's Guide. EasyView K-Type Thermometer. Model EA11A

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Sound Level Meter SD Card real-time Datalogger

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

Hygro-Thermometer / Datalogger

4-Channel Thermometer / Datalogger

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

USER GUIDE Turbidity Meter Model TB400

Large Vane CFM/CMM Thermo-Anemometer

Datalogging Conductivity/ TDS Meter. Instruction Manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Earth Resistance and Resistivity Tester

3 Channel Datalogging Thermometer

Light Meter SD Card real-time datalogger

Vibration Meter SD Card real-time datalogger

Large Vane CFM/CMM Anemometer / Psychrometer

Video Borescope Inspection Camera

Datalogging Hygro-Thermometer

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Digital Vane Thermo-Anemometer Model

Conductivity and TDS Meter Pen Style Water Quality Meter

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

User Manual. Thermocouple Datalogging Thermometer. Model EA15

User's Guide. Cup Thermo-Anemometer. Model AN400

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

User's Guide. Hot Wire Thermo-Anemometer Model

Barometric Pressure / Humidity and Temperature Datalogger

Digital Sound Level Meter

Dual Moisture Meter Pin / Pinless Moisture Meter

4-Channel Vibration Datalogger

Humidity & Temperature Datalogger

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

USER GUIDE. Differential Thermometer Datalogger. Model HD200

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer

User's Manual. VA893 Thermo Anemometer

User's Guide. 3 Channel Datalogging Thermometer Model SD200

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

User's Guide. Heavy Duty Differential Pressure Manometer. Model

USER GUIDE. Coating Thickness Tester. Model CG104

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

Heavy Duty Differential Pressure Manometer. Model User's Guide

Vibration Meter and Laser Combination Tachometer

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

Model A Current Calibrator. User Guide

Heavy Duty Hot Wire CFM Thermo-Anemometer

Heat Stress WBGT Meter

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

Formaldehyde Thermo-Hygrometer

Heavy Duty Mini Vane CFM Thermo Anemometer

User Guide. Moisture Meter. Model MO250

User's Guide. Datalogging Hygro-Thermometer Model SD500

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

Heavy Duty Vibration Meter

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Coating Thickness Tester

Model A Current / Voltage Calibrator. User's Guide

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

USER GUIDE. Waterproof Borescope. Models BR300 and BR350

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

Mini Digital Multimeter

Operations Manual EcoSense ph100a

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Datalogging Hygro-Thermometer

TC41-Thermocouple Thermometers User Manual

11 in 1 Environmental Meter

600 g x 0.02 g DIGITAL BALANCE

Anemometer SD Card Datalogger. Instruction Manual

Fruit Hardness Tester

SuperHeat Psychrometer Models RH350 and RH355 (kit)

Coating Thickness Tester

Hygro Thermo-Anemometer Model

USER GUIDE. Noise Dosimeter with PC Interface. Model

Transcription:

User Guide Conductivity Meter Model EC210

Introduction Thank you for selecting the Extech EC210 conductivity meter which simultaneously displays conductivity and Temperature. Conductivity is measured with a remote electrode that includes a thermistor for measuring temperature. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide. Features Three ranges 2000uS, 20mS, and 100mS with auto range functionality Conductivity, TDS and temperature measurement functions Detachable probe for ease of use in a variety of measurement environments User adjustable automatic temperature compensation (set to 0 for uncompensated Conductivity measurements) Carbon rod electrode type for longevity LCD display shows Conductivity and Temperature simultaneously DATA HOLD for holding displayed reading Record and view MIN MAX readings Programming mode for selecting o C/ o F temperature units, enabling/disabling the auto power off utility, and programming the temperature compensation functionality 2

Meter Description 1. Main measurement display 2. Temperature reading 3. Power/Escape button 4. Function/Hold/Up arrow button 5. Record/Enter button 6. Setting/down arrow button 7. Battery compartment (rear) 8. Probe connection 9. Probe 1 2 3 4 5 6 7 8 9 3

Conductivity Calibration 1. Connect the Conductivity electrode to the input socket at the bottom of the meter. 2. Switch the meter ON by pressing the POWER/ESC button. 3. Prepare a Conductivity Standard Solution (for example, 1.413uS). 4. Hold the probe by its handle and immerse the sensing electrode completely in the standard solution. Shake/stir the sensing electrode to allow the electrode s internal air bubbles to escape from the sensing electrode. 5. Press the HOLD button and the display will show the HOLD icon. 6. Press the REC button and the upper display area will show CAL and the lower display area will show YES. To abort at this point, simply wait and the meter will revert to the normal operating mode. 7. To continue, press the ENTER button and the display will show the Conductivity reading, the measurement unit, and, shortly after, the flashing CAL icon. Note that the meter will show END if the electrode does not detect an appropriate solution value. 8. While the CAL icon is flashing use the arrow buttons to adjust the displayed Conductivity reading to match the Conductivity value of the solution. 9. After a few seconds the meter will display END. Calibration is complete. Conductivity Measurements Measurement Preparation Before taking measurements, perform the calibration described above if necessary. Taking Conductivity Measurements 1. Connect the electrode to the probe input socket. 2. Switch the meter ON by pressing the POWER/ESC button. 3. If the display does not show Conductivity units (us or ms), press and hold the FUNCTION button until the Conductivity units are displayed. 4. The lower display will indicate the temperature value. 5. The upper display shows the conductivity value. 6. Hold the electrode in hand and fully immerse the sensing head in the standard solution. 7. The upper display will show the conductivity value of the measured solution. The bottom display will show the temperature value of the measured solution. 8. Rinse the probe with distilled water after each use. 4

TDS Measurements 1. Connect the electrode to the probe input socket at the bottom of the meter. Immerse the probe in the measurement solution. 2. Switch the meter ON by pressing the POWER/ESC button. Press and hold the FUNCTION button until the ppm units are displayed. 3. The lower display shows the temperature value. 4. The upper display indicates the TDS value (measured in ppm). 5. Hold the electrode in hand and fully immerse the sensing head in the standard solution 6. The upper display will show the ppm value of the measured solution. The bottom display will show the temperature value of the measured solution. 7. Rinse the probe with distilled water after each use. 8. Press and hold the FUNCTION button for at least 2 seconds to return to the conductivity measurement mode. Solution Temperature The lower display indicates the temperature of the measured solution. Refer to the Setup Mode section for instructions on selecting o C/ o F temperature units and for adjusting the automatic temperature compensation. Data Hold Press the Function/Hold key to freeze the displayed value. The LCD will display HOLD along with the held reading. Press the Hold key again to release the data hold function. MIN MAX Data Recording When selected, the Data Recording function records the Min and Max readings: 1. Press the REC button once. The REC indicator will appear on the display. Press REC button once again and REC MAX will display on the screen along with the maximum value. 2. Press REC again and the display will show REC MIN and the minimum value will be displayed. 3. To release the held MAX or MIN reading, press the HOLD button while either the REC MAX or REC MIN icons are visible; now only the REC icon will be visible. The meter is now continuing to monitor the highest (MAX) and lowest (MIN) readings but is displaying real time measurements. To view the MAX and MIN values again use the REC button as described earlier. 4. To exit the Record mode, press and hold the REC button for at least 2 seconds. The display will return to the normal operating mode. 5

Setup mode Note: If the HOLD or MIN/MAX functions are active the Setup mode cannot be accessed. To enter the Setup Mode press and hold the SETTING button for at least 5 seconds (until the beep is heard) and then use the SETTING button to scroll through the setup options. The options are: SEt Automatic temperature compensation percentage; settable from 0.00 to 5.00% per C (the default is 2.00%). Set to 0.00% to take uncompensated Conductivity measurements. When power is cycled this parameter will revert to the default 2.00% C/F Select the temperature units ( C F) OFF/ON Auto power off disable/enable Continue with the instructions below: Temperature Compensation Percent Setting (SEt) When the display shows SEt press ENTER. SEt will flash and the upper display will show the temperature compensation percent. Use the and buttons to set the desired temperature compensation percentage. After selecting the desired value, press ENTER to save the data. The display now shows the temperature units. Continue below: Temperature Units Select The lower display shows C or F. Use the button to select the desired unit of measure and then press ENTER to save. The lower display should now show OFF YES or NO. Continue below: Auto Power OFF Enable/Disable The display will show OFF YES or OFF NO. Use the button to select YES or NO. YES: Auto power OFF is enabled (meter switches off automatically after 10 minutes) NO: Auto power OFF is disabled Press ENTER to save the selection. The meter will return to the normal operating mode. 6

Battery Replacement The 9V battery that powers the instrument requires replacing when the battery icon flashes on the display. To replace the battery follow the steps below: 1. Disconnect the probe from the instrument. 2. Open the rear battery compartment using a screwdriver to remove the two Phillips head screws that secure the compartment. 3. Carefully remove the old battery from the compartment lid chamber and gently unsnap the battery s terminals from the wired (red/black) connectors. 4. Install a new 9V battery by snapping the battery terminals onto the wired connectors (observing correct polarity) and inserting the battery into the compartment lid chamber. 5. Install the compartment lid chamber into the meter housing and secure with the two screws. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. 7

Specifications General Specifications Circuit Display Measurements Data hold Memory recall Auto power off Sample rate Operating conditions Battery power Power Consumption Weight Dimensions Custom one chip LSI microprocessor circuit Dual function LCD Dimensions: 44mm X 29mm (1.73 x 1.14 ) Conductivity, TDS, Temperature Data hold freezes displayed reading Min/Max readings store and recall Meter switches off after 10 minutes (can be disabled) 1 second (approx.) Temperature: 0 to 50 C (32 to 122 F); Humidity: < 80% RH 9V alkaline battery Approx. 6.0 ma DC 295 g (0.65 lbs.) including batteries & probe Meter: 135 x 60 x 33mm (5.3 x 2.4 x1.3") Probe: 22mm (0.87 ) diameter x 120mm (4.72 ) length Electrical Specifications Measurement Range Resolution Accuracy Conductivity 20.00mS/100.0mS/2000 us 0.01mS/0.1mS/1uS + (2%FS+1dgt) TDS 1,200/12,000/66,000 ppm 1/10/100ppm + (2%FS+1dgt) Automatic Temperature Compensation range 0 to 50 o C (32 to 122 o F) Copyright 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 8