SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

Similar documents
Data Broadcast Switch

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Conitel ASYNC Adapter

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

SCADA Point-to-Point Multiplexer

Multi-Port Controller

SPL - DS TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

SRX Frame Relay TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

SRX Multidrop TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

SCADA Multidrop Multiplexer

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

BT-1 TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4 SECTION 4 - OPERATION...

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

MODEL No. SW1X8 RS422 SWITCHER

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

Enhanced Mini-Chansim Model VCS-232

FA-2448 SIX POSITION Filter Wheel

XC300 VDSL Network Extender Owners Manual

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

Boca s Family of Ethernet Products

USBTHERE User Guide USB100EXT. Featuring ExtremeUSB Technology

Enclosure TS-530 User Manual

MEC-COM-M154. User s Manual

VC-422C VTR CONTROL ROUTER

3 Input Multiplexer Operation Manual

ANC Series RS-422 Serial Communications Adapter

MEC-COM-M114. User s Manual

ECLIPSE SX. Midnight Finish. Compact Color Grading Control Surface. Users Manual

USER MANUAL MODEL 515 DB-15 Surge Protector

Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels

AB300-Series Automated Filter Wheels

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

DSU 5600 Data Service Unit USER MANUAL

F280XD Fiber-Optic RS-232 Modem Technical Manual

ADAM Fiber Optic to RS-232/422/485 Converter

An ISO-9001 Certified Company

USB Ranger 110/410 User Guide

Dual-Link DVI over 2CAT6 Extender

4X1 Switcher For 1.3. Model # HDMI-SW-4X1 USER MANUAL.

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

Owner s Manual. Date of installation: Installed by: Installer phone#: Serial #:

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

USBTHERE User Guide USB110EXT USB120EXT. USB110 EXT shown. Extending the Range of USB

ZM24x Quick-Connect Industrial Modem. User s Manual

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Kramer Electronics, Ltd. USER MANUAL. Model: RC-BT1 / BT-1. Bluetooth controller

UHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation

Installation Instructions

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

Serial Converters WTS 1201/-CP. RS-232 to IEEE b Wireless Converter with WEP Encryption, and External Antenna

MTS-2000 USER S MANUAL

RS422 PORT SWITCHER REMOTE CONTROL PANEL

Model No. ST200-S-RCP

User's Manual PLC09 Modbus Converter for PAL-AT Leak Detection System

Plus-X AC-8. User Guide

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

OPERATING MANUAL TCAT-2DF CONTROLLER PHYSITEMP INSTRUMENTS INC. 154 Huron Avenue Clifton NJ USA Tel: Fax:

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

CAT5-1600A Extender. EXT-CAT5-1600A. User Manual

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

PC 150. Digital Bench Scale. Operation Manual

USBTHERE User Guide USB204EXTFIB. Featuring ExtremeUSB Technology

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

UltraAV DisplayPort to HDMI Display MST Hub

6-Circuit ( ) and 3-Circuit ( ) 56/64xN Data Service Unit (DSU) Data Port (DP)

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ASKING FOR ASSISTANCE

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

User s Manual ANC-6023 RS232/RS422/Video Sync Interface Adapter

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

DATA CONNECT ENTERPRISE

DV-HDA-14AUD 1x4 HDMI Distribution Amplifier Manual

TABLE OF CONTENTS. Introduction Operation Notes Installation Front Panel Layout Front Panel Function Description...

Appendix A Cable Pinouts

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Transcription:

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - CONTROLS AND INDICATORS...6 SECTION - EXECUTIVE PORT...9 SECTION 6 - INTERFACE SIGNALS AND CABLING...1 SECTION - TROUBLESHOOTING...1 SECTION - WARRANTY...1 Data Comm for Business, Inc. 0 Pioneer Street Champaign, IL 610 Rev. Date: November 1, 1996 1--0 Firmware Rev.. / 0. 0000

1. DESCRIPTION The SPL Hub is a statistical time division multiplexer for multiplexers. It is designed for use with DCB SPL or SR series statistical multiplexers. Hubs are available in,, 6,, or 10 channels. Hubs are typically used to combine data from two or more multiplexers at a host and deliver it across a single high speed link to a remote location. At this location, a multiplexer can be installed for local port access to the host. Tail circuit modems are then attached to the remaining ports to feed other remote locations in the same geographical location. The composite link between hubs must be synchronous up to 6 Kbps. Connections to local multiplexers must be asynchronous. Modem tail circuits may be either sync or async.

. SPECIFICATIONS.1 Product.1.1 Data Ports Speed Synchronous to 19. Kbps (6 Kbps on Port units) Asynchronous at 00, 100, 100, 00, 00, 9600, or 1900 bps (00 bps on, or 6 port units) Interface.1. Network Port Speed RS-D, implemented in DB- female connectors Synchronous only, to 6 Kbps Interface. Environmental RS-D, implemented in DB- male connector Operation: 0 to 6 C, 10 to % relative humidity Storage: -0 to C, 10 to % relative humidity. Physical / Electrical 10." W x 9." D x." H 10 VAC external power supply 0 watts,.6 amps maximum. Network Management Port Commands Help Port Show Configuration Configure Ports Type Hub ID Port ID NMP Parity Disconnect NMP Repeat Last Command Reset

. INSTALLATION.1 Unpacking The following is included with each SPL Hub: Hub and external power supply Cable for connecting the network port to a modem or DSU Manual Information regarding warranty, maintenance contracts and repair. Location Place the Hub in a clear area where you can reach the front panel for setup and the rear panel to connect the cables. The Hub has an external power supply that requires a properly grounded 10 VAC outlet. The total power cord length is about 1 feet.. Setup Each port on the hub must be configured properly for the attached device. See Section for configuration switch locations and settings.. Connections..1 Network Port The network port must be connected to a synchronous modem or DSU. A conductor straight through cable is supplied for this connection... Direct Connection to a Multiplexer Multiplexer network (composite) ports are connected directly to hub ports using straight through cables. DCB multiplexers are shipped with a cable for connecting the multiplexer to a modem. This cable should also be used to connect the multiplexer to a hub. Multiplexer network ports must be set for asynchronous operation when connected to a hub. For SPL series multiplexers this is done with switches. Consult your SPL manual for network switch settings. For SR series multiplexers, optional ASYNC firmware is required.

.. Connection to Modem Tail Circuits Tail circuits are used to extend a multiplexer from a remote hub location to other remote locations. This can be done using modems, DSU/CSUs, line drivers, or other appropriate equipment. If the equipment is synchronous (supplies transmit and receive clocks on pins 1 and 1) then the hub port should be set for synchronous. If asynchronous equipment is attached, set the hub port for the appropriate async speed. If synchronous modems are used, one of them should be set for Slave clock. A crossover (null modem) cable is required for this connection. See Section 6 for cable configuration.

. CONTROLS AND INDICATORS.1 Switches The front panel of the Hub is held in place with magnets. It can be easily removed by pulling on the small handles provided. Behind this panel are one or more circuit boards. Each circuit board has several banks of switches called DIP switches. Port 11 Port 1 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 Network Port Port 1 Port Figure 1 Configuration Switches Power Transmit Condition Receive Error Multiplexing Test 1 Reset Switch Loopback Switch Figure Indicators and Special Switches 6

.1.1 Network Switch All sections of the 6-position network switch must be down..1. Port Switches Ports are configured using the -position DIP switches. Position 1 sets sync or async operation. Positions and are used to set port parity for async mode only. Positions and are not used. Positions 6 thru are used to set the asynchronous speed. Port Switch 1 6 Sync UP Async DOWN None DOWN DOWN Even UP DOWN Odd UP UP 00 UP UP DOWN 1900 UP UP UP 9600 DOWN DOWN DOWN 00 DOWN DOWN UP 00 DOWN UP DOWN 100 DOWN UP UP 100 UP DOWN DOWN 00 UP DOWN UP.1. Loopback Switch The loopback switch is a three position toggle switch located on the bottom circuit board between the Multiplexing and Test indicators (Figure ). This switch is normally set to the center position. When pushed to the right, local loopback is enabled to all ports..1. Reset Switch The reset switch is a small pushbutton switch located on the bottom circuit board between the Power and Transmit Condition indicators (Figure ). Pressing this switch will reset the hub. If this fails to clear a problem, disconnect power from the unit for five seconds and then reconnect.

. Indicators There are five indicators visible on the front panel. These indicators provide information about the hub's operation. You should become familiar with which lights are on during normal operation. If this pattern changes, there may be a problem. The indicators and their function are: POWER ON when power is applied to the unit. TRANSMIT CONDITION OFF - There is no DCD from the attached modem or DSU. This indicates that the communications link is down. ON - DCD is present from the attached modem or DSU. This indicator will also be on if no modem is connected to the hub because DCD defaults high. RECEIVE ERROR Flashes when a data error is detected. MULTIPLEXING Flickers when the hub is active. TEST ON when the loopback switch is set to the right. Besides these five main indicators there are eight smaller indicators located behind the front panel directly to the left of the network switch. Receive Data Port Transmit Data Port Receive Data Port 1 Transmit Data Port 1 1 Switches & Memory configuration differ Figure Mini LEDs

. EXECUTIVE PORT.1 Introduction The Executive Port (Exec) provides access to vital system information. By connecting a terminal or modem to the Exec Port, this information is at your finger tips.. Connections and Setup The Exec port is accessed through a DE-9S connector on the rear of the unit. To connect to the Exec port, use one of the cables shown in Section 6...1 Using a Terminal Set your terminal for 9600 bps and data bits, no parity and one stop bit. Use the cable described in Section 6 to connect the Exec port to the terminal... Using a Modem To use a dial-in modem for remote access you must fix the DTE interface speed of the modem at 9600 bps, data bits, no parity and one stop bit. Refer to your modem manual for appropriate setup procedures. Connection to the modem must be made using the Exec port to modem cable shown in Section 6.. Using the Executive Port To activate the Exec port, press the ENTER key. When you see AT YOUR COMMAND >>, the Exec port is active and ready for your commands. Type H<Enter> to display the command set. 9

. Commands..1 Help (H) COMMAND PARAGRAPH Help H..1 Help Port HP.. Show Config SC.. Config Ports CP.. Type TY.. HUB ID ID..6 PORT ID PID.. NMP Parity P.. Disconnect NMP BYE..9 Repeat Last Command *..10 Reset RESET..11.. Help Port The Help Port (HP) command displays switch settings for the -position port configuration switches... Show Config The Show Config (SC) command shows the current port configuration settings and port identifiers for all ports. Use this command to verify proper port configuration... Config Ports The Config Ports (CP) command is used to set ports for sync or async operation and to set the async speed and parity. If port configuration is set using this command, an asterisk appears on the Show Config screen next to settings that differ from the switches, and a mini LED flashes... Type The Type (TY) command displays information about the local hub including number of ports and firmware version. 10

..6 Hub ID The Hub ID (ID) command allows you to enter an identifier for the local hub. This ID can be up to 1 characters... Port ID The Port ID (PID) command allows you to enter identifiers for each hub port. This is handy for documenting which port serves which remote location. Port IDs can be up to 1 characters... Parity The Parity command (P) sets the parity for the executive port. The factory default is SPACE...9 Disconnect NMP The BYE command toggles the CTS output from the executive port. This is used to disconnect equipment such as dial-up modems or the DCB Access Switch...10 Repeat Last Command To repeat the last command, simply press the "*" key. This is handy for repeating screens of constantly changing data...11 Reset The Reset command resets the local hub. This is equivalent to pressing the reset pushbutton. 11

6. INTERFACE SIGNALS AND CABLING 6.1 Connector Location and Pin Reference Port 1 Port 11 Exec Port Network Port Port 1 Figure Connector Location - Rear View Pin1 Pin 1 Pin 1 Figure Connector Pin Reference 1

6. Port Interface 6..1 Network Port (DB-P) Pin Signal In/Out 1 Frame Ground --- Transmit Data OUT Receive Data IN Request to Send OUT Clear to Send IN 6 Data Set Ready IN Signal Ground --- Data Carrier Detect IN 1 Transmit Clock IN 1 Receive Clock IN 0 Data Terminal Ready OUT 6.. DTE Ports (DB-S) Pin Signal In/Out 1 Frame Ground --- Transmit Data IN Receive Data OUT Request to Send IN Clear to Send OUT 6 Data Set Ready OUT Signal Ground --- Data Carrier Detect OUT 0 Data Terminal Ready IN 6.. Exec Port (DE-9S) Pin Signal In/Out 1 Frame Ground --- Transmit Data IN Receive Data OUT Request to Send IN Clear to Send OUT 6 Data Set Ready OUT Signal Ground --- Data Carrier Detect OUT 1

6. Cables 6..1 Network Port to Modem A conductor cable is supplied with the hub for this purpose. If a longer cable is needed, a minimum of 10 conductors are required. Hub DB-S 6 1 1 0 Modem DB-P 6 1 1 0 6.. DTE Ports To a local SPL Multiplexer Hub DB-P 6 0 SPL Multiplexer DB-P 6 0 To a local SR Multiplexer Hub DB-P 0 SR Multiplexer RJ- 6 1

To a Tail Circuit Modem Hub DB-P 1 1 6 0 Modem DB-P 1 1 6 0 NOTE For asynchronous tail circuits, pins 1 and 1 are not required. 1

6.. Exec Port To a TERMINAL Exec DE-9P Terminal DB-P 0 6 To a PC (using terminal emulation) Exec Computer DE-9P DE-9S DB-S or or or 0 6 or 6 or 1 or or To a dial-up MODEM for remote access Exec DE-9P Modem DB-P 0 16

. TROUBLESHOOTING.1 General Approach 1. When troubleshooting problems, a rational plan can save you many hours of frustration. The following is a brief outline of standard troubleshooting procedures.. Gather the facts to determine the exact nature of the problem.. Draw a picture of the system showing the equipment at both the host and remote ends and the phone lines or in-house wiring. Use this as a reference to note your observations, test steps and test results. A picture keeps you focused and often saves duplicate effort.. Record the front panel indications before changing anything. This is an important part of fact gathering. If you change anything, change only one thing at a time. 1

. WARRANTY All DCB products are warranted to be free of defects in materials and workmanship for one year. Data Comm for Business, Inc. will repair or replace any equipment proven to be defective within the warranty period. All warranty work is F.O.B. Champaign, IL. This warranty is exclusive of abuse, misuse, accidental damage, acts of God or consequential damages, etc. DCB liability shall not exceed the original purchase price. All equipment returned for warranty repair must be accompanied by a Returned Material Authorization (RMA) number. To receive an RMA number, call (1) -0 between the hours of AM and PM central time. Equipment must be shipped prepaid to DCB and will be returned at DCB's expense. Data Comm for Business, Inc. 0 Pioneer Street. Champaign, IL 610 Tel (1) -0 Fax (1) -00 Email support@dcbnet.com 1