Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information on the family of SED2 VFDs, see the SED2 Variable Frequency Drives Submittal Sheet (154-042). Bypass Power Features 2-Contactor: Output & Bypass Overload protection in bypass mode. Step-down transformer with fused primary and secondary. Contactors electrically and mechanically interlocked. 3-Contactor (optional): Input, Output, & Bypass In addition to the 2-contactor features, 3-Contactor features provide: Drive test function Complete electrical isolation of drive Input Device Disconnect Input Device Fused disconnect (optional) Drive Drive Circuit breaker (optional) All doors are interlocked and padlockable Motor 2 Contactor Bypass Motor Reactor Options Line reactor mounted in bypass option enclosure. Line reactor (in NEMA 1 enclosure) supplied separately. VF0302R1 3 Contactor Bypass Load reactor mounted in bypass option enclosure. Load reactor (in NEMA 1 enclosure) supplied separately. Input Device Bypass Control Features Auto Bypass Relay logic allows user to send the motor to bypass mode based on the drive s programmable relay. The drive s programmable relay, typically set to fault, can be set up for applications that run full speed for an extended period of time. Enable Input Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote Start/Stop Common remote start/stop can be used in both drive and bypass mode. Essential Services Mode Typically used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Bypass Door Mounted Control Devices 2-Contactor Units Drive-Off-Bypass selector Bypass pilot light 3-Contactor Units Drive-Off-Bypass selector Bypass pilot light Drive Test on/off selector Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 1 of 8
Submittal Sheet February 22, 2008 SED2 Variable Frequency Drives With C-Bypass Options Product Numbers Your Product Number: Example Product Number: V B A 4 4 0. D 1 2 0 X Model VB VFD with Bypass VV VFD Variant [See Note 1] BY Bypass only [See Note 1] Series A Conventional Bypass Voltage 1 208 V 2 230 to 240 V 3 380 to 480 V 4 500 to 600 V HP rating 0.5, 0.7, [See Note 2 for these selections] 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10., 15., 20., 25., 30., 40., 50., 60., 75., 100, 125 [See Note 3 for these selections] Disconnect D Disconnect F Fused Disconnect B Circuit Breaker NEMA rating 1 NEMA Type 1 5 NEMA Type 12 [See Note 4] Contactor 0 None 2 2 Contactors 3 3 Contactors Reactor [See Note 5] 0 None 3 Line Reactor 5 5% Line Reactor L Load Reactor Filter X Factory Required Designator A Filtered to Class A requirements Options (If no option is required, leave field blank) (3-digit No.) Standard Variant Number (3-digit factory-assigned number) HA1 High Amp Rating [See Note 6] ("M" plus 2 alpha char.) Multiple Motor Control ("M" plus 2 factory-assigned alpha char.) CMS Contactor Motor Selection Notes: 1. VV and BY models are not availabe in all combinations. 2. Available only with Voltage Codes 1, 2, and 3. 3. Available only with Voltage Codes 3 and 4. 4. Available only in certain VBA/VVA models. 5. Only a single reactor can be installed in a bypass enclosure. If both are required, a separate enclosed reactor is required. 6. HA1 option is a bypass rated to 178 amps at 480 Vac. It is only available as 125 hp, 480V. Though it does not meet NEC for 150 hp at 180 amps, the package will be able to control a high percentage of 150 hp motors. Typical Specifications SED2 Bypass Options shall send the motor to bypass mode based on an easily accessible door-mounted selector or based on the drive s programmable relay. A bypass pilot light shall provide indication of the bypass mode. The bypass mode shall provide overload protection. Contactors shall be electrically and mechanically interlocked. An essential services mode shall send the motor to bypass regardless of the selected mode. Page 2 of 8 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.
SED2 Variable Frequency Drives With C-Bypass Options Submittal Sheet Dimensions = Protective Shield 11.0 (279) Frame Size A and B 8.3 (211) 36.0 (914) 36.0 (914) 24.0 (610) 5.5 (140) 49.0 (1245) 11.0 (279) Frame Size C 9.7 (244) 5.5 (140) 36.0 (914) 57.5 (1461) 18.0 (457) 17.0 (432) Frame Size D 11.3 (287) 9.5 (241) 7.0 (178) NOTE: Table 1. C-Bypass Approximate Weights. Frame Wt. lb (kg) A 55 (25) B 65 (29) C 100 (45) D 170 (77) E 200 (91) F 500 (227) Exact weight will be affected by actual horsepower/voltage and selected power options. 48.0 (1219) VFD0007R3 66.5 (1689) 18.0 (457) 17.0 (432) Frame Size E 11.3 (287) 9.5 (241) 57.5 (1460) 45.5 (1156) Frame Size F Figure 1. C-Bypass Dimensions in Inches (cm). 17.4 (442) Table 2. C-Bypass Frame Sizes and Power Ranges. HP kw 208/240V 480V.5.37.75.55 A 1.75 A 1.5 1.1 2 1.5 B 3 2.2 B 5 4 7.5 5.5 C C 20 15 D 25 18.5 30 22 E D F E 75 55 100 75 125 90 N/A F HA1 10 40 7.5 30 15 50 11 37 60 45 575V C D E F N/A Table 3. C-Bypass Output Current Ratings (Amps) Per NEC Motor Tables. HP.5.75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 HA1 208V 2.3 3.0 3.9 5.5 7.4 10.4 16.7 22 28 42 54 68 80 104 130 154 240V 2.2 3.0 3.9 5.5 6.8 9.6 15.2 22 28 42 54 68 80 104 130 154 480V 1.1 1.6 2.1 3.0 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 178 575V.9 1.3 1.4 2.1 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 NOTE: Drives are current rated devices. Verify that the listed ratings are the motor full load current rating. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 3 of 8
Submittal Sheet SED2 Variable Frequency Drives With C-Bypass Options Wiring Diagrams FU2 116 1L1 116 1L2 TRANSFORMER PRIMARY CONTACTS: 240/480/575V PRIMARY VOLTAGE. ACTUAL CONNECTIONS VARY WITH VOLTAGE. [H1] [H3] [H2] [H4] 5 OL1 SUPPLIED 4 1 4 SAFETIES 3 (96) (95) [XF] FU3 [X1] [X2] SECONDARY VOLTAGE 115 VAC X2 2 ESSENTIAL ESSENTIAL 13 SERVICE 14 15 SERVICE 16 ENABLED ACTIVE ESR (12) 3 ESR (14) (13) 5 1 REMOTE 2 6 RR START (14) (13) VFD1 (CONTROL TERMINALS) 5 21 22 7 DR1 (14) (13) (8) ESSENTIAL SERVICE RELAY RUN RELAY DRIVE RELAY #1 5 OFF INSTALL DRIVE FOR REMOTE RR 8 10 OPERATION 11 12 xoo 9 10 5 6 (12) (8) (SHIPPED WITHOUT ) INSTALL FOR LOCAL 10 OPERATION 12 oox 7 8 INSTALL (SHIPPED WITH FOR NORMAL ) OPERATION VFD OUTPUT ESR M1 14 CONTACTOR 15 16 17 xoo 11 12 M2 (10) (2) (SHIPPED WITH (A1) (A2) ) xoo M2 13 (A1) M1 A (A2) 18 M3 (A1) (A2) CONTACTOR LIGHT VFD INPUT CONTACTOR 8., 4 X DRIVE TEST ON OFF xo TERMINAL NUMBER X ON CBT-1. ONLY SUPPLIED WITH OPTIONAL THREE CONTACTOR (ADDITION OF DRIVE INPUT CONTACTOR). Figure 2. C-Bypass 120 Vac Control Circuit. Page 4 of 8 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.
SED2 Variable Frequency Drives With C-Bypass Options Submittal Sheet Wiring Diagrams continued NOTES: 1. Branch circuit protection to be provided by installer, per UL508A, if not provided with drive. 2. For bypass operation, modify these drive parameters: P0704[0] and P0704[1] = 3. 3. Control and communication wiring should be 300V UL minimum. 4. Communication wiring should be run with maximum separation possible from all other wiring. 5. Essential service mode operates the motor full speed (bypass) with no protection for the motor or system. 6. Ensure that automatic bypass will not damage the system before activating. 7. See Siemens Publication No. 125-3215 for proper fuse and wire sizes. 8. See Siemens Publication No. 125-3201 for SED2 VFD input/output control signal wiring details. Figure 3. C-Bypass Power Circuit. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 5 of 8
Submittal Sheet February 22, 2008 SED2 Variable Frequency Drives With C-Bypass Options Wiring Diagrams continued CONTROL TERMINATIONS LOCATED ON DRIVE I/O MODULE. 20 21 22 23 24 25 12 13 14 15 16 17 26 27 28 29 30 +10VDC +0VDC DRIVE CONTROL TERMINATIONS PTC A AIN1+ 1 2 3 4 5 6 7 8 9 10 11 105 108 RL1 NC RL1 NO 109 PTC B DIN5 DIN6 AO2+ RL1 COM RL2 NC RL2 NO RL2 COM AIN2- AO1+ AO1- AO2- ISO 0VDC P+ DIN4 ISO 24VDC AIN2+ N- AIN1- DIN1 DIN2 DIN3 ANALOG INPUT EXAMPLES EXTERNAL EXTERNAL 0 TO 10V 0/4 TO 20mA 2 3 2 3 4 - + SPEED + - POTENTIOMETER 1 2 3 4.7K OHM VFD 24 VDC POWERED 0/4 ma DEVICE (POWER CONSUMPTION CANNOT EXCEED 100mA) 2 3 4 9 28 ma POWER RR M2 M2 CONTROL INTER-CONNECTION BETWEEN PANEL. CONTROL TERMINATIONS LOCATED IN ENCLOSURE CBT-1. REMOTE START SUPPLIED SAFETIES INSTALL FOR REMOTE OPERATION CONTROL TERMINATIONS INSTALL FOR LOCAL OPERATION TERMINALS 9 THROUGH 12 ARE USED FOR AUTO FEATURE. IF USING THIS FEATURE, SEE INSTRUCTION FOR WIRING AND FOR DRIVE PROGRAMMING. ESSENTIAL SERVICE ENABLED ESSENTIAL SERVICE ACTIVE NOT FOR USE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 VFD0182R1 PROVIDE DRY CONTACT PROVIDE DRY CONTACT WITH SHIPPED WITH INSTALLED FOR NON-AUTO OPERATION PROVIDE DRY CONTACT PROVIDE DRY CONTACT Figure 4. C-Bypass Terminations. Table 4. C-Bypass Specifications. Specifications Description 208V, 3AC ±10% 240V, 3AC ±10% Input Voltage (3 phase) 480V, 3AC ±10% 575V, 3 AC ±10% Operating: 32 F to 104 F (0 C to 40 C) Temperature Storage: 40 F to 158 F ( 40 C to 70 C) Humidity 0 to 95% rh, non-condensing Page 6 of 8 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.
SED2 Variable Frequency Drives With C-Bypass Options Submittal Sheet Drive Specifications Input voltage and power ranges (3-phase) Input frequency Output frequency Power factor VFD degree of efficiency 96% to 97% Switch-on current Auxiliary supply 24V Overload capacity Control method PWM frequency Fixed frequencies Skip frequency bands Setpoint resolution Digital inputs (sink/source) Analog inputs Relay outputs Analog outputs Serial interface Protection level Temperature ranges Humidity Operational altitudes Protection features Standards CE conformity NOTE: Table 5. Drive Specifications. Description 208V and 230V to 240V, 3AC ±10%. 1/2 hp to 60 hp 380V to 480V, 3 AC ±10% 1/2 hp to 125 hp 500V to 600V, 3 AC ±10% 1 hp to 125 hp 47 Hz to 63 Hz 0 Hz to 150 Hz 0.9 total, 0.97 displacement Less than nominal input current Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 ma 110% for 60 seconds Linear, parabolic and programmable V/f; and flux current control low-power mode 2k Hz to 16k Hz (adjustable in 2k Hz increments) 15 programmable 4 programmable 0.01 Hz digital, 0.01 Hz serial, 10 bit analog 6: fully programmable and scalable isolated digital inputs, switchable 2: 0 to 10 Vdc, 0/4 to 20 ma, can also be configured as digital inputs or Ni 1000 input 2: configurable 30 Vdc /5A (resistive), 250 Vac 2A (inductive) 2: programmable (0/4 to 20 ma or 0 Vdc to 10 Vdc) RS-485; Protocols: USS, P1 and N2; Transmission rate: Up to 38.4k Baud IP20: NEMA Type 1 with protective shield and gland plate installed IP54: NEMA Type 12 Operating: 14 F to 104 F ( 10 C to 40 C) Storage: 40 F to 158 F ( 40 C to 70 C) 95% rh, non-condensing Up to 3280 ft (1000m) above sea level without derating Under-voltage, Over-voltage, Overload, Ground fault, Short circuit, Stall prevention, Locked motor, Motor overtemperature l 2 t PTC, Over-temperature, Parameter PIN protection. UL, cul, CE, C-tick Conformity with EC Low Voltage Directive 73/23/EEC SED2 Compliance with EN61000-3-12: Beginning September 1, 2005 all electrical apparatus covered by the EMC directive must comply with EN61000-3- 12 Limits for harmonic currents produced by equipment connected to public low voltage systems with input currents > 16A and =< 75 A per phase. Siemens variable speed drives of the product range SED2 (Micromaster 436) fulfill the requirements of the EN 61000-3-12 (without the need for external line reactors) regarding the THD values of Table 3 under the pre condition of Rsce > 190. The required PWHD values will not be achieved. Due to this fact it is recommended to apply for connection approval at the local electricity board. The local electricity board will evaluate among many other data the content of the 5th harmonic current and the Line Power Factor "Lambda, which is the ratio of active power and apparent power. Siemens frequency inverters are optimized in design and operation characteristics regarding energy efficiency and less interference with line supplies. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 7 of 8
SED2 Variable Frequency Drives With C-Bypass Options Submittal Sheet Table 6. Order Worksheet. Item Qty. Designation Part Number Description Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2008 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com. Country of Origin: US Page 8 of 8