HT-SG-100. Electronic Gas Engine Speed Governor. Smart Governing. Benefits

Similar documents
Digital Speed Controller User Manual

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Speed monitor D / / 2014

Zenith DS9000 Dispensing System

Operating instructions. Switching amplifier DN0210 DN / / 2015

MSI-RM2 Safety Relays

PanelView Plus/VersaView CE Terminals and Display Modules

Comprehensive Modular Genset Controller

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Compact Universal Controllers

2301D ST Digital Load Sharing and Speed Control

V E2B Snap-in I/O Module

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Conductive Level Controller

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Table of Contents. Safety. Attention. Warnings

V E1B Snap-in I/O Module

3+1 U CPCI Serial System

Installation Manual Series PWD 00A-400. Amplifier for Proportional Directional Control Valves. Bulletin HY M1/UK

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

TECHNICAL DATASHEET #TDAX023300

3/4 U CPCI Serial Case System

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

TEP 100WIR Series, 100 Watt

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

CPCI System Subrack 1 U

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Sliding shutter control Aluminium shutters

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

PHOENIX CONTACT - 07/2006

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

DTC P0AA6 - High Voltage Isolation Fault

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES.

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DC562, digital input/output module,

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Digital generator set control PowerCommand 1301

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Non-communicating room controllers

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Installation, Operation and Maintenance Instructions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

TECHNICAL DATASHEET #TDAX023240

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

F1000 User's Manual. (Version: V1.01)

DC561, digital input/output module,

SMVector Additional I/O Module Installation and Operation Manual

EX-RC1 Remote I/O Adapter

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

MDM 011-Z1 Regen Resistor

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

MINI-PS AC/10-15DC/8

2301E ST Steam Turbine Control for Small Generator Applications

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

V /06/ Velleman nv

Control D. Controller Module for Proportional Valve Control. Installation Manual

RTU500 series Data Sheet Power Supply CP-E 24/2.5

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Rotary version, three-position control

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Operating Instructions Differential Pressure Transducer PS27

DX561 Digital Input/Output Module

Replacement of GCP-10 Series with easygen-1500 Application Note

Model NPN output PNP output Standard. configuration

Features. Application range. Si-TEC Xtend Recip interface. Accumulated data recording of engine running hours, kwatt hours, kvar hours, etc.

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Operating instructions Evaluation system for flow sensors VS / / 2013

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Service Instructions. Conductor 420

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Transcription:

Benefits Suits 12/24 VDC systems IP65 sealed Bi-directional CAN Bus enabled Clear LED Display ( default) Simple 3-button Interface sent as std. J1939 value Idle speed Overspeed Protection Sent as std. J1939 FMI code Speed Ramp Fuel Ramp Crank Termination Start Fuel Position Fuel Limit 3 Speeds Variable Speed Droop Multi PID settings Acceleration Deceleration Synch/Load-sharing via 0-10V analogue input or J1939 SpeedUP/SpeedDown External Speed Trim Position Mode Smart Governing The is an electronic speed governor especially suited to gas engines. Its digital processing not only provides flexibility in configuration but also allows CAN J1939 data exchange with many rn controllers. The unit will internally convert the signal from a standard inductive flywheel pick-up to an value, it on the 4-digit LED and also send it as a standard J1939 value to a connected controller. If the exceeds the set Overspeed value, the unit sends the standard J1939 FMI code in addition to cutting current to the actuator. The unit s desired speed can also be set by standard J1939 SpeedUp/SpeedDown commands over the CAN Bus connection as well as by a conventional 0-10V synchronizing and load sharing signal input. This J1939 integration simplifies the wiring, saves installation time and allows implementation of more sophisticated controller features. InGovern smart speed controllers are fully potted for sealing and vibration resistance and suitable for mounting on or close to a running engine. They provide precise (<0.25%) isochronous rotational speed control. The is supplied pre-configured and once the number of flywheel teeth is input (1 x press of [Fn] button then [+] or [-] until the correct value is ed) then the engine will run. All parameters are stored in non-volatile memory. Fine tuning of the main PID loop and other common features can be done using the same 3 buttons on the front panel. The supplied PC software (which connects via a standard USB cable no dongle required) provides an overview of all settings, allows user-friendly PID adjustment on a running engine and allows access to secondary parameters including a second PID loop. The final configuration can be saved and downloaded to other s for multiple engine applications or for series production.

Technical Specification Safety instructions and Warnings Before installing and starting the device, please read the operating instructions. These contain important notes for safety and use. No liability can be accepted for damage arising from failure to follow the instructions or any inappropriate use. The governor may only be used for the manner of operation prescribed in the operating instructions and only in connection with third-party devices and components recommended or installed by us or software supplied by us. Any other use shall be considered inappropriate use and will result in the voiding of all liability and warranty claims against the manufacturer. Interventions and alterations that influence the safety technology and the functionality of the governor may be carried out only by the manufacturer. Fault-free and safe operation is conditional upon competent transport, assembly and installation as well as qualified use and correct maintenance. All relevant accident prevention regulations and other generally recognised technical safety and health and safety at work rules are to be observed. Fault-free functioning of the machinery and its peripheral components is only guaranteed with original accessory parts and spare parts. The engine speed governor is robust enough to be placed in a control cabinet with other operating control devices or installed on the engine. If water, mist or condensation can come into contact with the controller, it should be mounted vertically, allowing the liquid to flow away from the controller. Extremes of heat should be avoided. Overspeed protection IMPORTANT An overspeed shut down mechanism must be installed separately from the control system as a safety measure, to prevent engine faults that may result in damage or injury to machinery or persons. A secondary shut down device ( air shut-off valve) must be installed. Installation and connection General information The pick-up cable should be shielded to guarantee that no electromagnetic interference can reach and affect the engine speed governor reading. The shield should be connected to the battery negative. To maintain the correct distance between the flywheel and the sensor, the sensor must be rotated in until the flywheel touches and then rotated out again for ¾ of a rotation. This achieves the correct spacing between flywheel and sensor. To be able to start the engine, the sensor must generate at least 1V AC RMS during the start. 2 Cross-section of the battery and actuator cable at terminals A,B,C, and D: 1.5 mm 2 for 24 VDC or 2.5 mm 2 for 12 VDC For longer cables (>5m) the cable cross-section is to be increased appropriately to keep the voltage drop low. Battery positive (+) input, connection M, should be fused 10 A. The governor should be installed such that the housing has connection with the chassis of the control cabinet. The cable of the actuator must be shielded along its entire length. The cable of the pick-up sensor must be shielded along its entire length. The cable of the variable speed input can be up to 5m long. For longer cables, a shielded cable must be used. The shielding must always be grounded such that it does not come into contact with the chassis of the machine. This is to prevent stray signals from entering the governor and causing interference. The shield must be grounded at one end. Connection terminals Connection Description Definition terminal A SPEED2 Speed Setting 2 B GND Ground C SPEED3 / Speed Trim Speed Setting 3 / Speed Trim D +5VDC Sensor feedback supply E GND Ground / chassis F IDLE Idle G GAIN GAIN parameter set 1 or 2 H EXT SPEED Load distribution / synchronisation I GND Battery Ground J J+ Actuator (Plus) K K- Actuator (Minus) L L- Battery (Minus) M M+ Battery (Plus) N N- Pickup (Ground) O O+ Pickup (Plus) P LO CAN low Q HI CAN high R DROOP Droop

Accessing the functions In SETUP, the functions listed below can be accessed using the [Fn] button. Each press of the [Fn] button makes the next menu active. The active menu is shown on the LED for 2 seconds, after which the relevant value of this function appears. Settings are changed with the arrow keys [-] [+] and raise/ lower the. If the arrow keys [-] [+] are held down longer, the value increases at a greater rate. Regular Mode Normal operating 2x press 3x press 4x press 5x press 6x press 7x press 8x press 9x press 10x press 1 [+] button: 1x press [-] button: 1x press Press & Hold [Fn] button for 3 seconds Quick if required 1 5 0 0 G E A r/ 1 2 0 Number of teeth 1500 120 teeth G A I / 5 0. 2 P value* 50.20% I n t / 2 1. 9 I value* 21.9% d E r / 7. 0 D value* 7.0% C r A n / 5 0 0 500 F u r A / 3 Fuel ramp 3 sec. S P r A / 1 0 s t P o / 5 0 o S P d / 2 0 0 0 Crankspeed Speed ramp Start Position Overspeed 10 sec. 50% 2000 d r o o / 3. 0 Droop % 3.0% 1 5 0 0 2 0 0 0 2 0 0 1 2 0 0 0 1 9 9 9 q u i Increase Reduce quick 1500 for all parameters for all parameters to access only PID Menus *Display of the values is dependent on input G (Gain). If this is open, parameter set 1 (Gain 1, Int 1 and Der 1) is shown; if the input is closed, parameter set 2 (Gain 2, Int 2 and Der 2) is shown. Quick Mode Normal operating Designed in Switzerland * 1 5 0 0 1500 [Fn] button: G A I / 5 0. 2 P value* 50.2 % [Fn] button: 2x press I n t / 2 1. 9 I value* 21.9 % [Fn] button: 3x press d E r / 7. 0 D value* 7.0 % [Fn] button: 4x press 1 5 0 0 Press & Hold[Fn] button for 3 seconds Regular if required r E G regular General Features for all Types and Modes Press & Hold [+] and [-] button for 3 seconds to know the firmware version Press [Fn] and [-] button to exit from Menu [+] button: [-] button: v 2. 0 0 1 5 0 0 2 0 0 0 2 0 0 1 2 0 0 0 1 9 9 9 Working firmware version Increase Reduce 1500 to access all the Menus Version 2.00 1500 for all parameters for all parameters *Display of the values is dependent on input G (Gain). If this is open, parameter set 1 (Gain 1, Int 1 and Der 1) is shown; if the input is closed, parameter set 2 (Gain 2, Int 2 and Der 2) is shown. Hardware use (Keypad) and Dimensions The has three menu buttons, with which allows parameters to can be set locally. The set values are indicated on the LED. In normal operating, the is indicated on the. 3

Wiring Diagram 4

Technical Data Performance Isochronous/stability...±0.25% range...300 Hz - 8 KHz (112-4000 for flywheel with 160 teeth) variation with temperature...±0.25% max. Idle adjustment...full Range Speed Trim...Programmable 0-100%, (default = 5%) Surroundings Temperature range...-40 to 85 C (-40 to +185 F) Relative humidity...up to 95% Surface finish...fungus Proof and Corrosion Resistant CE certificate... EN61326-1 Input/output parameters Supply voltage...12 or 24 VDC Battery, (6.5 VDC to 33 VDC) Polarity...Negative Ground (housing isolated) Current Consumption...90 ma max. continuous, (Excluding actuator drawn current) Max permitted actuator current...8 A continuous (at 25 C) Engine speed sensor signal...1 120 V RMS +5VDC Output (Terminal D)...up to 12 ma Load Share/Synchronizer Input...0-10 VDC (5V nominal, reversed, 5 /V) Reverse Power Protection...Yes Transient Voltage Protection...60V Norms/standards Authorising office...ce and RoHS requirements Communication...SAE J1939 Reliability Vibration...7G, 20-100 Hz Shock...20G Peak Inspection...100% functionality inspection Mass and weight Dimensions...139 x 107 x 32 mm Weight...0.372 kg Installation...direct on engine chassis, preferably vertical, with rubber shock absorbers, insulated, or in control cabinet Configuration parameters Number of flywheel teeth, range...50-255 teeth Overspeed protection...max. 4000 Starter cut-out speed...4000 * Fixed...4000 * Variable...4000 * Prescribed start quantity...0-100 % Fuel Ramp...0 20 sec. Speed Ramp...0-100 sec. * Depending on Overspeed Protection. These values are always < Overspeed. Local Distributor / Partner: AG (LTD) Murgenthalstrasse 30 4900 Langenthal Switzerland Phone: +41 62 916 50 30 Fax: +41 62 916 50 35 e-mail: sales@huegli-tech.com www.huegli-tech.com Features and specifications are subject to change without prior notice _DS_EN_02.2015