Humidity & Temperature Datalogger

Similar documents
Humidity & Temperature Datalogger

Datalogging Hygro-Thermometer

3 Channel Datalogging Thermometer

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Barometric Pressure / Humidity and Temperature Datalogger

USER GUIDE. Differential Thermometer Datalogger. Model HD200

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

Temperature & Humidity Datalogger

12-Channel Thermocouple Datalogger

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Digital Sound Level Meter

Indoor Air Quality Meter/Datalogger

USER GUIDE Turbidity Meter Model TB400

User's Guide. EasyView K-Type Thermometer. Model EA11A

Sound Level Meter SD Card real-time Datalogger

Video Borescope Inspection Camera

3-Axis G-Force Datalogger

Humidity + Temperature + Pressure Datalogger

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Datalogging Hygro-Thermometer

User Manual. Thermocouple Datalogging Thermometer. Model EA15

Light Meter SD Card real-time datalogger

Heat Stress WBGT Meter

Heavy Duty Vibration Meter

Hygro-Thermometer / Datalogger

Large Vane CFM/CMM Thermo-Anemometer

Mini Digital Multimeter

True RMS AC Voltage/Current Datalogger

User's Guide. Humidity + Temperature + Pressure Datalogger. Model RHT50

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Large Vane CFM/CMM Anemometer / Psychrometer

User's Guide. Datalogging Hygro-Thermometer Model SD500

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

3-Axis G-Force Datalogger

4-Channel Thermometer / Datalogger

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Vibration Meter SD Card real-time datalogger

User's Guide. 3 Channel Datalogging Thermometer Model SD200

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Digital Sound Level Meter

USER GUIDE. Coating Thickness Tester. Model CG104

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

USER GUIDE. AC/DC Magnetic Meter. Model MF100

Mini Digital Multimeter Model MN15. User's Guide

ph/orp Meter SD Card real-time Datalogger

User Guide. Conductivity Meter. Model EC210

Earth Resistance and Resistivity Tester

USER GUIDE Current Calibrator

User's Guide. Temperature / Humidity Datalogger. Model 42270

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Vibration Meter and Laser Combination Tachometer

Personal Sound Level Meter

Heavy Duty Datalogger Module

USB Temperature and Humidity Data Logger Instruction Manual

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

4-Channel Vibration Datalogger

USER GUIDE. Waterproof Borescope. Models BR300 and BR350

User's Guide. Hot Wire Thermo-Anemometer. Model

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Formaldehyde Thermo-Hygrometer

USER MANUAL Video Particle Counter with built in Camera Model VPC300

testo 176 Data loggers

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

USER GUIDE. Noise Dosimeter with PC Interface. Model

Digital Sound Level Meter with USB Model:

testo 184 Data logger Instruction manual

TR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to

User Guide. Video Borescope. Models BR200 and BR250

Model A Current / Voltage Calibrator. User's Guide

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

User's Guide. Datalogging Light Meter with PC Interface. Model

Model A Mini AC/DC Clamp Meter. User's Guide

Fruit Hardness Tester

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Digital Sound Level Meter MODEL

Model A Current Calibrator. User Guide

testo 175 Data loggers Instruction manual

Heavy Duty Datalogging Light Meter

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

User's Guide. Cup Thermo-Anemometer. Model AN400

Dual Moisture Meter Pin / Pinless Moisture Meter

High Definition VideoScope

USER GUIDE. Model Noise Dosimeter with PC Interface

RS Stock No Instruction Manual RS Input Data Logging Thermometer

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

Heavy Duty Datalogger Module

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

Industrial Multimeter Extech EX510

Transcription:

User Manual Humidity & Temperature Datalogger Model RHT Additional User Manual Translations available at www.extech.com

Introduction Congratulations on your purchase of this Temperature and Humidity datalogger. With this meter, you can monitor and log data over long periods of time and then easily transfer the data to a pc for viewing and evaluation. The LCD display provides current or Max/Min temperature, humidity and time information. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version and translations of this User Manual, Product Updates, Product Registration, and Customer Support. Description 1 Record LED Alarm LED LCD Display 4 Temperature Humidity display selection 5 MAX/MIN display selection 6 Battery Compartment (rear) 7 Temperature and Humidity sensors 8 USB PC port (bottom) 1 4 5 6 7 8 Display Description Full battery symbol. Weak battery symbol. Replace battery when this appears. Battery life is more than months. DATE: Current date is displayed TIME: Current time is displayed Time and Date automatically swap every 1 sec. MAX: Maximum value during a datalogging session is displayed MIN: Minimum value during a datalogging session is displayed REC: Recording in progress indicator FULL: Memory is full indicator %RH: Humidity value is displayed C: Celsius temperature units F: Fahrenheit temperature units

Operation: The display and front panel buttons provide a means to view the status of the datalogger, observe the current Temperature or Relative Humidity and to view the MAX and MIN values recorded during a recording session. The datalogger setup conditions such as sample rate, temperature units and alarm values are programmed via the provided software. Refer to the software Help File on the disk for those procedures. 1. Press the MAX/MIN button to view the recorded Max and Min values with the time they were recorded. If, while in this mode, no button is pressed for 4 seconds the display will automatically return to the real time display.. The Time and Date display will automatically toggle every 1 seconds. When downloading the data to the PC, -PC- will be displayed on the LCD. After the download is complete, the datalogger will display the last value recorded, but it will stop recording. The logger needs to be re-set from the software to begin a new recording session. 4. The REC LED will flash at the programmed rate when the unit is datalogging. 5. Alarm function: When the measured value exceeds the programmed upper or lower limit and the LED function is selected in the software, the ALM LED will flash one time per minute. 6. If -LO- is displayed, the temperature and humidity sensors need attention. 7. The datalogger should be placed upright when in use. 8. If used in low temperature, high humidity environment, the datalogger should be placed upright in a dry area to remove any condensation before downloading the data. 9. Battery life can be extended by leaving the datalogger connected to a pc. 1. Disabling the REC and ALM LED s will extend battery life. 11. The LCD display will stop functioning at very low temperatures and will become active again when the unit is returned to higher temperatures. NOTE: The logger needs to be re-set from the software to begin a new recording session. Combination Lock The logger is supplied with a wall mount case and security combination lock. The lock is shipped with a ---- code as viewed from the side with the alignment bar. To change the code: 1. Press the release to open the lock (1). Using a pointed object, press IN and HOLD the locking pin on the bottom of the lock ().. Set the new code () and release the locking pin 1

Software Installation 1. Place the CD in the drive and then follow the on-screen installation instruction.. After the software is installed, keep the CD in the drive and connect the datalogger to the PC by the USB cable.. A USB Driver installation window will pop-up; follow the directions to install the driver. Software application The Datalogger USB software is a program for collecting data from the DATA LOGGER when it is connected to a PC or notebook computer. The data may be displayed graphically, as Excel or similar programs. The major functions are all listed in the main window. System Requirements Check the software download page of the extech.com website for the latest version of the PC software and its operating system compatibility. Minimum Hardware Requirements: PC or NoteBook with Pentium 9MHz or higher, MB RAM; At least 7 MB byte hard disk space available to install HT Datalogger USB software Recommended display resolution 14 x 768 with High Color (16 bit) Software Operation The Software operation is described in the HELP file. Maintenance WARNING: To avoid electrical shock, disconnect the meter from any circuit and turn OFF the meter before opening the case. Do not operate with an open case. Battery Replacement 1. Remove the green protective cover by pushing the bottom of the meter until it slides through the opening at the top.. Remove the two Phillips head screws that secure the battery compartment at the back of the meter.. Open the battery compartment and replace the.6v lithium battery observing correct polarity. 4. Re-assemble the meter before use. Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 6 days or more, remove the battery and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment 4

Specifications Display Multi-function LCD Measurement ranges to 1% RH -4 to 158 F, -4 to 7 C Resolution.1,.1RH Maximum data points 16,5 Temperature and 16,5 Humidity values Sample rate 1s to 4h selectable Analysis software Check the software download page of the extech.com website for the latest version of the PC software and its operating system compatibility. Open input indication "LO" appears on the LCD Low battery indication Empty battery symbol appears on the LCD Power supply.6v Lithium Battery Battery life months (approximately) Operating Temperature -4 to 158 F, -4 to 7 C Operating Humidity to 1% RH LCD Operating Temperature -1 F to 158 F (-5 C to 7 C) Dimensions.7x1.9x1.") (94.4x48.9x1.mm) Weight.oz (9.7g) Range Accuracy Relative Humidity to % and 8 to 1% ±5.% to 4% and 6 to 8% ±.5% 4 to 6% ±.% Temperature 14 to 14 F ±1.8 F -1 to 14 F and 14 to 158 F ±.6 F -4 to -1F ±8 F typical -1 to 4 C ±1 C -5 to -1 C and 4 to 7 C ± C -4 to -5C ±4 C typical Copyright 1 17 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 91 Certified www.extech.com 5