TEMPERATURE DOCUMENTATION with KIRSCH-DATANET

Similar documents
horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

NEW. EBI 40 Multi-Channel Data Logger Channels Large colored display Multifunctional ports. Food

Industrial PC - VL BPC

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

CMC III Universal Sensor

PIUSI FLUIDS SELF SERVICE MANAGEMENT 2018

Integrated Access Control Alarm Management System

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

CMC III Temperature/Humidity Sensor

MU110-6U. Analog output module 6 channel. User guide

Issue 11 / Industrial Panel PCs Focused on the essentials

How to register your user account and ECL Comfort 310 controller to the ECL Portal

Temposonics Magnetostrictive Linear Position Sensors

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Digital Camera CAM-SC30. For C-Mount. Data Sheet. Dr. Natalie Bischoff Creation Date Oct-09 Last Update 25-Jan-10 CAM-SC30

CyberX Industrial 5-Port PoE+ Gigabit Ethernet Switch Quick Installation Guide

84 Outdoor Dual-Sided Digital Sign (one side LCD screen, other side LED poster) Features: Model: NILDM-840PH

EXPLORER. Industrial Panel PC - Flexible Modular Design

Operating instructions. AUTOSEN:IO Version / / 2017

VenScan LMS. Inline moisture measurement system for web-shaped materials (decorative papers, finish foils, overlays, underlays, laminates)

T5a, T5b & T5c Temperature Tags

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Network Camera Quick Operation Guide

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Web monitoring tool (UTY-AMGX) Copyrights 2010 Fujitsu General Limited, Sales Division, All rights reserved.

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

our experience...your solution Controlling and Monitoring Gateway

Installation Manual rev

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

u::lux NetCon & u::lux NetCon Power

Calibration software Model WIKA-Cal

Version /11/2014. User Manual. PowerLine AV Gigabit Adapter/ PowerLine AV Gigabit Adapter starter kit DHP-600AV

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI.

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Extruder Controls ExtruVision S

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

INHECO ODTC Script Editor. For INHECO Script Editor Version and higher. User s Manual

Camera. Network Bullet Camera. Quick Operation Guide

USER MANUAL FOR MF0200 GATEWAY BOX VERSION 2.0

SpaceLogger.D10 USER MANUAL Richard Paul Russell Ltd. Richard Paul Russell Ltd

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

BiPAC 8200M. BiPAC 8200N

Assembly Instructions scancontrol 2700/2750 (500)

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

Hand-held thermometer Model CTH6200

AX3000 Platine Terminal Ethernet TCP/IP

WNVR SERIES. QUICK SETUP GUIDE CONTACT US. PHONE (English & Spanish) WEBSITE

Converter SINAMICS G150. Type 6SL37102G

Network Bullet Camera. Quick Operation Guide

Operating Instructions

4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement.

USER GUIDE. SW-MWLC100 Multiple Wireless Loadcell Controller Software

CTS-Software CID-Pro V5 Operating system has never been so simple and user-friendly!

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

Installation and Maintenance

control unit. Various interfaces ensure that it always has access to the latest data. Features of the FAFNIR technology

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (95 Watts, -40~75 degrees C, 12~48V DC)

Camera. Network Fisheye Camera. Quick Operation Guide

TEMPERATURE HUMIDITY PRESSURE ALL FOR YOUR WIRELESS MEASUREMENT AND DATA COLLECTION FROM ONE PROVIDER!

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

FCC Regulatory Information

Magelis ipc industrial PCs 0

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Laboratory refrigerators / freezers +4 / -20. X-Cold Series

Installation Manual. Alpha 4000 RGB Signs. Before you begin

AX3000 Platine Terminal Ethernet TCP/IP

Enterprise NVR System. alpha Technology Viewing Workstation Kit Quick Start Guide Version 5.85

optris CoolingJacket Advanced

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

TELTONIKA ModemUSB/G10 User Manual v0.1

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200

Purkinje Dossier System requirements. Version 5.0

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

USB-L111. USB-L111 User Manual TPM. Version: V M05. To properly use the product, read this manual thoroughly is necessary.

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IP-Bridge Module for establishing IP connections in 2-wire-based cablings

USB over IP Quick Installation Guide

Preface 1. Product Characteristics 3 SIPLUS CMS4000 ION SIMATIC TDC T001 Manual Software Installation 4

ELSAG North America Law Enforcement Systems, LLC

NVR SERIES 4/8/16/24/32 - Channel Network Video Recorder V

Intrinsically safe batch controller Batching Master 110i

* _1118* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Interface Adapter USM21A

Installation manual plugs and connectors with screw connection (16/32 A)

WAC-IPMG200 IP Based Access Control System

DFI Redefines Flexibility Through a Series of Modularized Embedded Systems for... Industrial Automation

TROVIS-VIEW software TROVIS 6661

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

More Precision. thermoimager TIM // Compact thermal imaging cameras

Data setting software MEXE02

Konica Minolta Color Care 2

DOCUMENTATION MADE FAST, EASY, AND NETWORKED

PROGRAMMER WITH A USB LINK PD14 USER S MANUAL

Alignment Software for Linear Guides

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Transcription:

TEMPERATURE DOCUMENTATION with KIRSCH-DATANET A maximum of quality assurance for your refrigerated goods - seamless, easy, reliable Seamless and reliable temperature documentation is often mandatory for quality assurance (e. g., for blood and pharmaceutical cooling). Manual recording of data requires valuable time and is often incorrect. Save your precious time and let our KIRSCH-DATANET software do the work. KIRSCH-DATANET software Seamless temperature documentation and analysis of the data as well as real-time monitoring of your refrigerating devices (software is included). Automatic temperature documentation and monitoring via network. An unlimited number of devices can be connected. (Can be also connected to a Wi-Fi transmitter.) PC-KIT-USB-MONITORING Automatic temperature documentation and monitoring via USB for up to 32 devices. Single-user version. Temperature documentation via USB stick. Unlimited devices can be connected. KIRSCH-DATALOG Retrofitting temperature documentation for devices without an RS485 interface and for third party devices. ADVANTAGES Cost-effective: - Reduced effort due to automatic logging - Software is included Easy: - Temperature documentation via Windows PCs - Data is automatically collected in refrigerators and freezers - Automatic readout and storage - Configuration of your cooling devices directly via your PC - The recorded data is automatically sent by e-mail - Read and transmit data via USB stick Flexible: - Easy retrofitting for KIRSCH devices equipped with an RS485 interface, otherwise via KIRSCH-DATALOG Safe: - Document and evaluate up to 39 values that are relevant for the functioning of the refrigerator/ freezer (e.g., door openings, alarm messages, etc.) - Decentralised hazard control is possible - Selectable alarm messages are transmitted by e-mail

Temperature documentation overview Übersicht Temperaturdokumentation Temperature documentation at a glance You have several options to document the temperature of your refrigerators and freezers. The most decisive factor is the efficiency and safety of your data and refrigerated goods. Efficiency PC-KIT-USB-MONITORING DATALOG-USB-MONITORING/ DATALOG-NET Datalogger in device Disc-type pen recording thermometer Manual recording Fig. 1: Diagram on efficiency and safety of different temperature documentation options Safety Temperature documentation Description Manpower requirements Automatic documentation Seamless documentation Monitoring Messaging in case of power failure Data export Manual recording Daily and multiple readings of thermometer values. High m m m m m Disc-type pen-recording thermometer Datalogger in device In addition to temperature recording, this enables you to store data about, e.g., opened doors, alarms, etc. on the control panel of your refrigerator. The stored data can simply be downloaded to a USB stick and read using the included KIRSCH-DATANET software. Seamless documentation is possible. DATALOG-USB- MONITORING DATALOG-NET PC-KIT-USB- MONITORING The disc-type pen-recording thermometer documents the temperature with a separate sensor. The temperature history is shown on the disc and can be viewed directly. The recording disc must be changed in regularly every 7 days. The Datalogger is placed in the interior of the refrigerator and records the temperature development. To read the stored data you need to take it out of the refrigerator and connect it to the PC. To retrofit temperature documentation and alarm funtions. Temperature monitoring and recording only. Compatibel with third party refrigerators. The measured data is transmitted automatically to the KIRSCH-DATANET software by a USB cable. Real-time monitoring is possible if the software is activated on the PC. Same as DATALOG-USB-MONITORING, but connection via TCP/IP gateway. The data is transmitted automatically to the KIRSCH-DATANET software. Real-time monitoring is possible if the software is activated on the PC. Same as however, the data is transmitted automatically via USB cable to the KIRSCH-DATANET software. Real-time monitoring of the temperature profile is possible if the software is activated on the PC. Medium m m m m Medium m m m Medium m Minor * Minor * Minimal * Same as, but the data is transmitted by network to the software that can be installed on a PC or on a server. Real-time monitoring is possible if software is activated on the PC. Alarm messages immediately pop up on screen, so that counteractive measures can be effected. Minimal * = Yes, m = No * possible only with activated software on PC and active gateway connection Manpower requirements can be: Manual monitoring and recording, coordination and management (e.g., using datalogger or by changing recording discs), transmitting the stored data from the refrigerator to the PC (e.g., ) etc.

KIRSCH-PC-KIT KIRSCH-PC-KIT overview We provide three solutions for your individual requirements for electronic temperature documentation. Suitable for all KIRSCH devices with a RS485 interface. (applicable on server or PC) PC-KIT-USB-MONITORING (applicable only on single-seat PC version) (applicable only on PC) Description Electronic temperature documentation and monitoring in a network. Automatic data transmission to server or PC. Electronic temperature documentation and monitoring without network connection. Automatic data transmission to PC. Electronic temperature documentation and data transfer via USB-Stick. Mode of operation Data recording in the controller of the refrigerator. Data transmission via TCP/IP gateway and network connection or even by Wi-Fi. Data recording in the controller of the refrigerator. Data transmission via USB gateway (USB cable connection) and series connection. Data recording in the controller of the refrigerator. Data transmission via USB stick. Number of evaluated values Data analysis wit KIRSCH- DATANET software 39 39 39 Number of devices for connection Unlimited (each device needs a PC- KIT-NET unit) Up to 32 devices (each device needs a PC-KIT-USB-MONITORING unit) Unlimited (each device needs a PC- KIT-STICK unit) Global access * m m Selected alarm messages are transmitted via e-mail Data recording for up to 72 hours in case of power failure m Requirements Network connection at location of the device Each device needs its own TCP/IP gateway and fixed IP address Operating system for server and PC: Windows For Wi-Fi: Ethernet-to-Wi-Fi adapter USB port on the PC To connect more than one refrigerator you need one PC-KIT-USB-MO- NITORING standard-kit to connect up to 31 devices each equipped with an extension-kit Operating system: Windows USB port on the PC Operating system: Windows Retrofitting For all KIRSCH devices with RS485 interface For all KIRSCH devices with RS485 interface For all KIRSCH devices with RS485 interface Scope of delivery TCP/IP gateway Cat-5 data cable, 5 m Attachement bracket Grounding clip for data cable Shielded data cable Standard-KIT: USB gateway USB cable, 1 m Shielded data cable, 10 m Grounding clip for the data cable Extension-KIT: Shielded data cable, 10 m 2 x grounding clip for data cable USB stick Control panel equipped with a USB readout unit = Yes, m = No * via remote access

KIRSCH-DATALOG overview KIRSCH-DATALOG To retrofit temperature documentation and monitoring for KIRSCH cooling devices without an RS485 interface and for third party devices. Complies with essential requirements of DIN specifications*, e.g., visual and audible alarm in case of temperature deviations. You can choose between two solutions: DATALOG-USB-MONITORING (single-seat PC version) connection via USB gateway 1) DATALOG-NET (network solution) connection via TCP/IP gateway 1) * DIN 58371 (blood storage), DIN 58375 (blood plasma storage), 58345 (pharmaceutical storage) 1) via integrated RS485 interface Retrofits temperature documentation and monitoring for KIRSCH cooling devices without an RS485 interface Connects third party devices to the monitoring circuit Industrial housing according to protection class IP65; protection against dust and water Minimum/ maximum temperature memory and adjustable setting for warning threshold KIRSCH-DATANET software is used for analysing data Visual and audible alarm in case of temperature deviations Digital temperature display D ata recording fo r u p to 7 2 h o u rs after power failure Mounting bracket for KIRSCH-DATALOG optional Scope of delivery: DATALOG-NET KIRSCH-DATALOG connected to a temperature sensor and a 10-m data cable TCP/IP gateway Cat-5-cable, 5 m Wall-mounting set Can also be used in refrigerators and freezers with explosionproof interior applications. For this purpose, the temperature sensor is connected via a safety barrier DATALOG-USB-MONITORING KIRSCH-DATALOG connected to a temperature sensor and a data cable USB gateway USB cable, 1 m Wall-mounting set Can also be used in refrigerators and freezers with explosionproof interior applications. For this purpose, the temperature sensor is connected via a safety barrier

KIRSCH-DATANET software overview KIRSCH-DATANET software (the software package is included for each version of electronic temperature documentation) Minimum effort and maximum safety thanks to: automatic evaluation and documentation of up to 39 values of your cooling devices, real-time monitoring (except ), also for remotely positioned devices, efficient management structures thanks to remote access to the server, possible integration into your existing server security environment, three different types of user profiles (administrator, user, guest), each time the KIRSCH-DATANET software launches, the program independently establishes a connection to the linked cooling devices and updates the data automatically, data can be either sent by e-mail or exported to other programs. Monitoring: Permanent control of your chilled goods With the assistance of the monitoring function you can monitor the current statuts of your cooling devices in real time. Alarm messages emitted from remotly positioned devices (e.g., door alarm in a device located in the basement) are displayed on the monitor. You can thus initiate immediate measures before damage occurs. 1 2 Tabular overview Documentation of the software status and settings or changes made by 1 user. Chronological list of events that occurred in the device with exact date 2 and time indication. 3 4 Channel selection 3 Selction of analogue or digital channel is possible. 4 Temperature profile of a refrigerator or freezer. 5 6 Device grouping and comment function 5 Organization of the devices by group (for example, models, departments, etc.). 6 Comments can be inserted directly in the graph, as are eg Deviations and immediately recognizable explained. System requirements: Hardware (minimum requirements): 2GHz Intel Core processor or AMD Opteron, AMD Phenom processor 1GB RAM 1GB free disc space, in addition to space for data recordings 1024x768 pixel graphic resolution and 32-bit colour depth 1 x USB 1.1 for connecting a USB gateway on the server side 1 x 100 or 1000 Mbps RJ45 LAN interface for connecting a TCP/IP gateway on the server side Operating system (the following operating systems are supported): Windows XP SP3 Windows Server 2003 SP2 Windows Vista SP1 Windows Vista SP2 Windows Server 2008 (not Server Core Role) Windows 7 SP1 Windows Server 2008 R2 (not Server Core Role) For x86 und x64; for Windows XP only x86 Windows Server 2012 Windows 8 Professional (not RT version) Software (the following software is a prerequisite):.net Framework 4.0 (made available at setup) Microsoft Internet Explorer 6.0 with Service Pack 1 Windows Installer 3.1 FTDI driver for USB gateway on the server side (made available at setup) Microsoft und Windows are trademarks of the Microsoft Corporation. All other product and legal company names are trademarks of their respective owners.

Used in more than 100 countries. Some examples: If you have any questions, please do not hesitate to contact us. We will be pleased to assist you. Philipp Kirsch GmbH Manufacturer of refrigeration technology for the health sector Okenstraße 103 77652 Offenburg Germany Tel: +49 (0) 781 9227-0 Fax: +49 (0) 781 9227-200 info@kirsch-medical.com Photograph this QR code and get to know our entire product range. Your reliable dealer in your area: D326/10.13 Subject to modifications. Printed in Germany on 100 % recycled paper.