FT2 View Instruction Manual

Similar documents
FT2 View Instruction Manual

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc.

MODBUS MESSAGE PROTOCOL FOR MODEL FT2 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER

MODBUS Message Protocol MODEL FT3

1. Before you can use your addresser you will need to install the ULinx RS485 USB Adapter.

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

Easy Config. Configuration tool for ATYS, COUNTIS and DIRIS INSTRUCTION MANUAL. easy-config_software

MODEL FT2 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER 399 RESERVATION ROAD MARINA, CA Revision I

USER GUIDE PEL 8K / PEL 8K-M

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

3DM-GX5-25 Attitude Heading Reference System (AHRS)

M2500 Engine Controller Configuration Manual

The PC Software can be downloaded from the Arcolectric Web Site:

M2500 Engine Controller Operator Manual

Kulite DAQ. Data Acquisition Software User s Manual. Version 3.2.0

Fox Thermal Instruments, Inc.

Instruments Division. Service Kit for SML SML-Z Printed in the Federal Republic of Germany E-2

HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction

UniPak UP448 Bridge Input Isolating Signal Conditioner

Master-Touch INSTRUCTION MANUAL. Series 9000MP Multipoint System Series 9600MP System Control Panel Thermal Gas Mass Flowmeters. version 7.

DATA ACQUISITION Hints and Tips

Darca Plus Eltek Download ing And Remote Con trol Applica tion

RST INSTRUMENTS LTD.

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

Data acquisition hardware

NF770 Temperature Compensation Liquid Flow Computer

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

CyberComm Pro Data Acquisition Software Installation & User Guide

Optimizer Collect User Manual. for MFC/MFM calibration with Integrator 110 and Drycal

Fox Thermal Instruments, Inc.

Touchscreen Driver Release Note

Welcome. Introduction and startup JUMO dtrans ph02. Dipl.-Ing. Manfred Schleicher

1875 Smart Calibrator. Instruction Manual

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

IFC 100 Supplementary instructions

User Manual. Thermo Scientific Orion

Data Logger / Network Gateway

NF760 Batch Controller

USER GUIDE PEL / PEL-M

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Installation and operation manual ReciFlow Gas

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

Poseidon 4002 MANUAL

Setting up FT3000 and version on Windows 7. This is a step by step guide for setting up the FT3000 on a new Windows 7 or 8 PC

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident & Trident X2 PD765

1 Introduction to the software

41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet: Fax: +39-(0)

USER MANUAL. FNet Fermentation Control Software

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

AKELA Vector Network Analyzer (VNA) Quick Start Guide

USB-Based Temperature & Humidity Sensor

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

METER Ultrasonic level transmitter

DTM Distributed Transmitter Monitor

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE

TTC Series Torque Tool Tester Operation Manual

OVEN INDUSTRIES, INC.

LogBook/300 Stand-alone, Intelligent PC-based, Data Acquisition System

FLOWMETER Ultrasonic flow transmitter

Real Time Electronic Acquisition & Monitoring. & Human Machine Interface REAM HMI. For Pumping Services

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001

SoftTools Suite 7.0. Flowserve Corporation

HiTECH. Technologies, Inc. INSTRUCTION MANUAL. NIVOSONAR SM-300 CONFIGURATOR Program

9936A LogWare III. User s Guide. Revision

Model PC20 Intelligent Field Device Configurator for Use with Transmitters with FoxCom or HART Communication Protocol

Installation and Operation Manual Model 9A02 Software Version 2.0

3700 SERIES USER MANUAL

User Manual (Vers. 1.03)

VeriMaster. Software tools. Measurement made easy. Overview

L.D.S. Laser Diffraction Sensor USER S PC SOFTWARE MANUAL V6.2 CERSA-MCI

9936A LogWare III. User s Guide. Revision

Dynamic Flow Computers, Inc Southwest Freeway, Suite 320 Stafford, TX Ph: (281) Fax: (281)

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 3.1)

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Hawk Alarms and Sensor Error Codes

Compact data logger offering best-in-class noise resistance and communication function

CONTENTS. 1- INTRODUCTION 1.1 Introduction 1.2 General Applications and Benefits 1.3 Identification 2- HARDWARE

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

GEN II Wireless GSM/GPRS Data Acquisition System

PD765 TRIDENT. Trident Series Process & Temperature Meters.

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Flow Computer. FloWEB

ACS2002 PC Software Instructions

Instruction Manual July sitrans RD SOFTWARE

Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices

RST INSTRUMENTS LTD.

Operating Instructions. Software UCOM. for configuring Höntzsch transducers UFA, UVA, UTA, U10, U10a, U10M, U12-Ex and U15-Ex

RS-FX-N01 wind transmitter user's Guide (485type)

Simple data sample and store to USB with the SDM3000 series of DMMs

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Clear Benefits of the KRAL Electronic.

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06

LB5900 Series Sensor Unattended Operation Guide

Videographic Recorders

PowerTrac USB and Link Users Guide Software Installation & Operation Manual

Thermal Mass Flowmeter

Transcription:

399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13

Introduction: The FT2 View application software is a program that runs on a PC and communicates with a Fox FT2 Thermal Mass Flowmeter. Installation: To install the FT2 View program, you must first download the file from the Fox website. The latest version of the FT2 View software is available for download at http://www.foxthermalinstruments.com/products/ft2view.php. To install the FT2 View program, run the FT2View_V#.##-setup.exe file that is located in the downloaded file. 1

After clicking Next the screen will show: Select the folder in which you wish to install FT2view, then click Install. When the program is done installing, you may exit, then restart your computer. 2

Operation: Connect a RS232 DB9 cable from the FT2 RS232 serial port located on the inside of the FT2 transmitter and a serial port of a PC. The serial cable must be a null modem cable or use a null modem DB9 adapter. If your PC does not have a RS232 port, you will need a USB to RS232 converter along with a VCP driver. If the PC is connected to the Internet and running Windows 7, the PC will try to automatically load the VCP driver. If the driver does not load automatically, download the VCP driver at: http://www.ftdichip.com/drivers/vcp.htm Run the application by clicking on FT2_View.exe and select the Communication port used when prompted by using the drop down menu and press OK. The COM port selection can be found by going to the control panel and opening the Device Manager and clicking on the PORT (COM&LPT). A COM port assignment should be displayed. 3

Welcome Screen The right side of the first screen shows all of the FT2 parameters which are scanned once upon entering the program. The left side of the window displays FT2 variables which are automatically refreshed about once a second. - The Error Code List button enables the user to display a list of error codes and their descriptions (see example below). - The Scan Enable/Disable button allows the user to stop and start the data scanning. - The Configure * button allows the user to enter a sub-menu to allow FT2 parameters settings and display. A password will be requested to access different levels of parameters protection. See pages 3-4 for more information. o * Please note that the Configure button will be visible only after communication has been established with the FT2. - The data can be refreshed by clicking on the Display Parameters button located at the bottom right. - Acquire data to Excel file button is use to save specified data at a requested time interval to an Excel spreadsheet. See page 6 for more information. - The Stop Acquisition button is clicked to terminate data collection. 4

Configure Menu: After pressing the Configure Menu button, a screen will prompt the user to enter a password that will allow access to some or all parameters. After entering the password (1234 for most parameters), the Configure Menu button will flash with Please Wait until the program has acquired all the parameters from the FT2 and displays them on the screen. Unit Select o Choose the Flow Rate unit, temperature in F or C and the pressure label. Temperature Calibration o The Temperature calibration section allows the user to modify the temperature calibration factors but should not be modified unless the temperature reading is out of calibration. Simulation o Flow rate, Temperature and sensor sense voltage can be simulated by clicking on the respective display box, entering new values and then selecting Sim=Enable. The Simulation message will be displayed on the FT2 local display every 10 seconds when operating in that mode. After a power cycle, the simulation mode will be automatically disabled. Display o The display section allows programming of the display 1 & 2 of the local display. Dsp1l1 is for display 1 line 1. Dsp1l2 is for display 1 line 2. Dsp2l1 is for display 2 line 1. Dsp2l2 is for display 2 line 2. 5

4-20ma o The 4-20mA section allows programming of the two 4-20 ma outputs for flow rate and temperature. The 20mA Flo is the flow rate corresponding to the 20 ma and the 4 ma Flo is the flow rate corresponding to the 4mA. 20 ma Temp and 4 ma Temp are settings for gas temperature. The 20mA flo cnt and the 4mA flo cnt are the calibration settings and should not be changed unless the output is out of specification. The 20mA Temp cnt and 4mA Temp cnt are for the output associated with temperature. Frequency o The frequency section allows the programming of the pulse output associated with flow rate. Three methods are provided to accomplish this. Method 1: the first method is by setting the maximum flow rate and corresponding frequency output (frequency may not exceed 100 hz) Method 2: the second method is by setting the number of pulses per unit of total (i.e 10 pulses per SCF) Method 3: the third is by setting the total unit per pulse (i.e 10 SCF per pulse). EE Prom o Recall EE from EEbackup is used to recall default parameters set at the factory when the unit was calibrated. A switch on the FT2 circuit board needs to be activated before performing this function. Other Parameters o CTC out allows the programming of the digital output as an alarm indicator for exceeding a certain threshold for flow rate or temperature. o CTC inp allows the programming on a contact input to reset the totalizer. o The Reset Total button is used to reset the FT2 total. o The Set database CRC is used to re-calculated the CRC associated with some of the critical parameters. This would be done to clear a Database CRC Error after verifying that all the critical database parameters are accurate. This button allows the user to reset the CRC associated with critical data in the event an error has been detected. All critical data need to be verified before resetting the CRC to avoid operating with corrupted data. RS485 Button o This button allows the user to configure the RS485 serial port and bus type. The RS485 settings apply only if the bus type selected is Modbus. 6

Save cfg to file Button o This button is used to save all the settings to a data file. Recall cfg from file Button o This button is used to recall previously saved settings from a file. Refresh screen Button o This button is used to refresh all the parameters on that screen. Calibration table Button o This button allows access to the flow calibration tables. o If the meter is calibrated with multiple curves, the Curve #2 and Curve #3 buttons may be used to view calibration table information of the other curves. Print Form Button o This button allows the user to print the page. 7

Data Acquisition to Excel File After selecting the Start Acquisition to Excel File button, a box will prompt the user to enter a list of data index to collect the data. Please refer to the Thermal Mass Flowmeter & Temperature Transmitter RS232 Message Protocol for data index codes. Data index should be separated with commas. Next a box will prompt the user to enter the sample interval time in seconds and then the file name. Select the directory in which you wish to log data. Ensure there are no spaces in the folder names and file name. The file name must end with.xls and do not save your data in the root directory, as Windows 7 does not allow this. 8

The program will collect the data to the Excel file at the specified rate and save it to disk every 30 seconds until stopped by pressing the Stop Acquisition button. 9