Doc# E V.1.02 QS - 1

Similar documents
GE Digital Energy Multilin EPM 4600 Quickstart Guide TELEPHONE: FAX: HOME PAGE:

Multilin EPM 4600 Metering Solution

PowerLogic High Density Metering System 1-Meter Enclosure

SEM3 - Embedded Micro Metering Module

PowerLogic ION7300 Series

Installing the Cisco AS5400XM Universal Gateway

SAVE THESE INSTRUCTIONS

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

MU110-6U. Analog output module 6 channel. User guide

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

Installation Instructions & User Manual

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

3300 ACM. Installation & Operation Manual. Economical Digital Power Meter/Transducer CONTENTS

G5 PDU Installation Guide

Panduit Basic Rack PDU

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

3700 SERIES USER MANUAL

CoPilot EXT. Electro Industries/GaugeTech. Installation & Operation Manual Revision PDA Based Software

Model 2380 Rack-Mount Kit

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

I/O SIGNAL CONDITIONER

A1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

DM3058/DM3058E Digital Multimeter

H704-42(H)(E), H704-42/1(H)(E)

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Optical Multiplexer. Quick Start Guide

PowerLogic ION7300 series Power and energy meter

Panduit Basic Rack PDU with Local Meter

RGM180 Display Series

Instruction Manual: IM E

Model 2380 Rack-Mount Kit

Power Xpert Meter 2000 Gateway Card Kit

EnerSure Installation Guide

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

9200 Power Meter. Installation & Operation Guide

Electronic Submeter with Advanced WiFi Ethernet Capability

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Multi Unit Enclosed Meter

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

RS232C/RS485 Data can be easily monitored by LAN

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Technical Specifications. Dual Source kwh Energy Meter

H3G-48B Production Description

H3G-TA ENGINEERING MANUAL

Installation & Operation Manual

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

HPE Intelligent Power Distribution Unit Installation Instructions

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

General Specifications. P2-SCM Serial Communications

Technical Specificaions. kwh Energy Meter

Power Xpert Branch Circuit Monitor

OilCop Component Wiring Installation Manual

UniStream HMI Panel. CPU-for-Panel

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

satech TSB-14 MAIN FEATURES

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

MC 11 EB-2 Power supply cabinet with external bus, AC version

P3-SCM. General Specifications

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

PACSystems RX7i IC698CHS009/119

ETC One Plus Network Communicator Installation and Operation Manual

AC Power Meter GPM-8212 USER MANUAL

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

User Guide Automatic Transfer Switch (ATS)

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Rack Installation Instructions

2.1 MANAGEMENT UNIT INSTALLATION

P3-RS Remote Slave Module

PM Series Power Meter

SmartZone Gateway- Enabled M Series Rack PDU

QUICK SETUP GUIDE. Raritan PXE. Safety Precautions. Before You Begin. Mounting the PDU. Unpacking the PXE. 1U Size

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Technical Specifications. Multi Function Meter

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

9500 and 9600 I/O Card Installation Instructions

F1000 User's Manual. (Version: V1.01)

User s Manual for SafeConnect

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

VAT series controller and transmitter. Manual

Installation and Configuration Guide

M40e and M160 CIP Installation Instructions

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

E2460GS Oscilloscope Upgrade Kit

Carbon Monoxide Sensor - ModBus

Installation Instructions for the AUTOcard-SA System

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Leased-Line Extenders over IP

NEW ERA METER. Installation & Operation Guide NE METER

H3G-380 Production Description

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

Transcription:

Mechanical Installation Recommended Tools for MP200 Unit Installation: #2 Phillips screwdriver; 1/4-inch (0.250 ) nut driver, socket, box, or open-end wrench; wire cutters. OTE: The MP200 unit is designed to withstand harsh environmental conditions; however it is recommended you install it in a dry location, free from dirt and corrosive substances. 7.60in 3.03in 193.1mm 76.9mm 0.19in 4.8mm 0.80in 20.4mm 4.50in 114.3mm 0.12in centered 2.9mm 10.98in 278.9mm centered 11.28in 286.5mm 0.28in 7.2mm 1. Mount the unit against any firm, flat surface. 2. Use a #8 screw in each of the four slots on the flange to ensure that the MP200 unit is installed securely. IMPORTAT! For safety reasons, mount the MP200 unit in an enclosed and protected environment, such as in a switchgear cabinet. Connect an earth ground to the post on the side of the MP200 unit, using an AWG 12 wire. Install a switch or circuit breaker nearby; label it clearly as the MP200 unit s disconnecting mechanism. 0.81in 20.5mm 3.18in 80.6mm 7.62in 193.5mm 4.36in 110.6mm Doc# E166705 V.1.02 QS - 1

Electrical Installation: WARIGS! For Electrical Installation: All Primary and Secondary circuits can, at times, produce lethal voltages and currents. Avoid contact with any current-carrying surfaces. The current inputs are only to be connected to external current transfomers (CTs). SERVICES: WYE, 4 WIRE. COECTIO TYPE: Direct Voltage, CTs 3 1 2 LIE V3 V2 V1 CT Shorting Block EI# SB-6CT I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Only one 3 phase circuit is shown. Duplicate for additional circuits. V3 FUSES 3 x 0.1A V2 V1 FUSE 3A L(+) (-) Power Supply Connection LOAD Service: Three Phase, 4-Wire WYE Service Direct Voltage and 3 CT Connection for Metering 8 Three Phase Loads: MP200-Y IMPORTAT! All CTs must have one side grounded to reduce shock hazard. EIG highly recommends using shorting blocks like the EI SB-6TC so that the meter can be removed from service while the CT is energized. You can order the EI SB-6TC at www.electroind.com. Doc# E166705 V.1.02 QS - 2

SERVICES: WYE, 4 WIRE. 3 COECTIO TYPE: 3PTs, CTs 1 2 LIE V3 V2 V1 CT Shorting Block EI# SB-6CT I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Only one 3 phase circuit is shown. Duplicate for additional circuits. V3 FUSES 3 x 0.1A V2 V1 FUSE 3A L(+) (-) Power Supply Connection LOAD Service: Three Phase, 4-Wire WYE Service with 3 PT Voltage and 3 CT Connection for Metering 8 Three Phase Loads - MP200-Y IMPORTAT! All CTs must have one side grounded to reduce shock hazard. EIG highly recommends using shorting blocks like the EI SB-6TC so that the meter can be removed from service while the CT is energized. You can order the EI SB-6TC at www.electroind.com. Doc# E166705 V.1.02 QS - 3

SERVICES: SIGLE PHASE, 2-WIRE COECTIO TYPE: Direct Voltage, CTs 1 LIE VL CT Shorting Block EI# SB-6CT I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Only three circuits are shown. Duplicate for additional circuits. VL Short Voltage inputs together FUSE 3A L(+) (-) Power Supply Connection LOADS Single Phase, 2-Wire Service with Direct Voltage and 1 CT Connection for Metering 24 Single Phase Loads: MP200-S IMPORTAT! All CTs must have one side grounded to reduce shock hazard. EIG highly recommends using shorting blocks like the EI SB-6TC so that the meter can be removed from service while the CT is energized. You can order the EI SB-6TC at www.electroind.com. Doc# E166705 V.1.02 QS - 4

SERVICE: SIGLE PHASE, 3-WIRE COECTIO TYPE: Direct Voltage, CTs To monitor 24 individual loads. See accuracy table for limiting factors. 2 1 LIE VL1 VL2 CT Shorting Block EI# SB-6CT Run lines VL1 and VL2 through the CT in opposite directions Set PT ratio to half in the meter. VL2 VL1 I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Only one circuit is shown. Duplicate for additional circuits. VL1 FUSES 2 x 0.1A Short Voltage inputs together FUSE 3A VL2 L(+) (-) Power Supply Connection LOADS Service: Single Phase, 3-Wire Service with Direct Voltage and 1 CT Connection for Metering 24 Single Phase Loads - MP200-S IMPORTAT! All CTs must have one side grounded to reduce shock hazard. EIG highly recommends using shorting blocks like the EI SB-6TC so that the meter can be removed from service while the CT is energized. You can order the EI SB-6TC at www.electroind.com. Doc# E166705 V.1.02 QS - 5

MP200 Metering System Configuration: 1. Connect to the MP200 unit through its USB port: Use a USB Type A to B plug to connect from your PC s USB port to the MP200 unit s USB port. If your PC doesn t automatically find the USB driver, download it from the product CD that came with the MP200 unit (see Appendix A in the MP200 USB Port Metering System Installation and Operation Manual on the CD). OTE: This Quickstart shows connection using the USB port. For Ethernet/Wifi or RS485 connection, see the MP200 Metering System Installation and Operation Manual. 2. Open Communicator EXT TM software (download from product CD). 3. Click Connect on the tool bar. You will see the Connect screen, shown on the right. Make sure the Address, Baud Rate, and Protocol settings match the ones here. 4. Click Connect - the Device Status screen confirms the connection; then click OK - the Communicator EXT TM application s main screen opens. Configuration Steps: 6. Click the Profile button on the tool bar. The Device Profile screen opens. The Tree menu on the left side of the screen lets you choose setting screens. 7. Click System Settings to open one of the screens shown below. Use this screen to name the MP200 unit (CPU) and to label the circuits (individual meters). You must give the MP200 CPU an individual, unique name to properly download data to the database. Doc# E166705 V.1.02 QS - 6

8. Click Communications (see instructions below). 9. Click CT, PT Ratios and System Hookup (see instructions below). Communications Settings: COM 1: RS485/ Ethernet/WIFI (optional) Address: 1-247; Baud Rate: 57600; Protocol: Modbus RTU/Modbus ASCII; Response Delay: 0-750ms; Parity: Odd, Even or one COM 2: USB port OTE: The USB port settings are fixed. COM 3: RS485 Address: 1-247; Protocol: Modbus RTU/ASCII Baud Rate: 9600, 19200, 38400, 57600 Response Delay: 0-750ms OTE: Click the (1)Default to Ethernet or (2)Default to Display button to set either the (1)Ethernet settings for COM1 or (2)Display settings for COM3, to their default values. CT, PT Ratios and System Hookup: ote that the settings you see on the screen depend on your MP200 unit s circuit configuration. The top screen is for an MP200 unit with the single phase circuit configuration (MP200-S). The bottom screen is for an MP200 unit with the three phase circuit configuration (MP200-Y). For PT settings, see the MP200 Metering System Installation and Operation manual, on the enclosed CD. The CT settings are: CT Ratios CT umerator (Primary): 1-65535 CT Denominator (Secondary): 5 or 1 Amp, depending on the MP200 unit s ordered option (this field is display only). Update Device: 10. When changes are complete, click the Update button to send a new profile to the MP200 unit. 11. Click Cancel to Exit the screen. OTE: For further details and additional programming screens, refer to the Communicator EXT TM 3.0 Software User Manual on the enclosed CD (access the software manual by clicking Help>Contents from the Communicator EXT TM application s Title bar). Communicator EXT is a trademark of. Doc# E166705 V.1.02 QS - 7