Power Meter PowerMonitor 500

Similar documents
I/O Modules with EtherNet/IP Architecture

Programmable Logic Controllers Micro850

Power Quality Monitor PowerMonitor 5000 M8

E1 Plus Electronic Overload Relay

Programmable Automation Controllers CompactLogix 5380

PanelView 5500 Operator Interface. 7-inch to 19-inch Displays

SECTION ( ) LIGHTING CONTROL PANELBOARD

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Digital Multifunction Meters. Digital Multifunction Meters

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

WM20. Power analyzer for three-phase systems. Benefits. Description

Energy Management Energy Transducer Type ET112

Energy Management Modular Energy meters Type EM2-96

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Metering Devices IQ 300

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

MIC-2 Multi-instrument DATA SHEET

Neon pr. ph/ ORP measurement. Applications. Description

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

MIC-2 MKII, Multi-instrument DATA SHEET

/8 DIN Universal Process Indicator

EM270. Multi-channel power analyzer. Benefits. Description

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

USER MANUAL 2012 V1.1

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Model Number Structure

Energy Management BUS Adapter Type VMU-B

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

Features various encoder interfaces and controls multiple analog servo drives at high speeds

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Multifunction Transducer MT440

EM271. Multi-channel power analyzer. Benefits. Description

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

MAJOR VA Power Inverter

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Solid State Relays with Failure Detection Function

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Programmable Relay ZEN V2 Units

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

MP7. Uninterruptible Power Supply

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

PMC 530 Series Advanced Multifunction Meter

Model Number Structure

PDI Modular Compact Remote Power Panel

ATV1200A kv kva

Energy Management BUS Adapter Type VMU-B 01

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

Technical Specifications. Multi Function Meter

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

MW/MVAR Transducer Specifications

High Voltage DC Meter

INTEGRA DIGITAL METERING SYSTEMS

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

SUBJECT TO CHANGE WITHOUT NOTICE

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

with Backlight Graphic LCD Screen

HMISCU6B5. Main. 60 right 40 top 60 bottom

NJ-Series Power Supply Unit NJ-PA/PD

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number Structure

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

PanelView Plus/VersaView CE Terminals and Display Modules

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

HIGH-VOLTAGE DC METER

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Transcription:

ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations have specific requirements, and does not recommend or intend any specific application based solely upon the guidelines provided here. Because of the variety of uses for this information, the user of, and those responsible for applying this information, are responsible for ensuring the acceptability of each application and appropriate use of the guidelines. In no event will be liable for misuse, misapplication or reliance on these guidelines in connection with any specific application. also disclaims indirect or consequential damages resulting from the use or application of this information. Note: To download or view a.doc file version of this procurement specification, please visit: www.rockwellautomation.com/industries/procurement-specifications 1420-SR001A-EN-P 1

TABLE OF CONTENTS PART 1 GENERAL... 3 1.01 SUMMARY... 3 1.02 RELATED DOCUMENTS... 3 1.03 REFERENCES... 3 1.04 PRE-MANUFACTURE SUBMITTALS... 4 1.05 FINAL SUBMITTALS... 4 1.06 QUALITY ASSURANCE... 4 1.07 DELIVERY, STORAGE AND HANDLING... 4 1.08 WARRANTY... 5 1.09 MAINTENANCE... 5 PART 2 PRODUCTS... 5 2.01 MANUFACTURERS... 5 2.02 CONSTRUCTION... 5 2.03 VOLTAGE AND CURRENT SENSING... 6 2.04 FUNCTIONS... 7 2.05 DIGITAL AND ANALOG OUTPUTS (OPTIONS)... 7 2.06 COMMUNICATION (OPTIONS)... 7 2.07 CONFIGURATION... 8 2.08 LCD DISPLAY AND INDICATORS... 8 2.09 GENERAL RATINGS... 9 PART 3 EXECUTION... 9 3.01 EXAMINATION... 9 3.02 INSTALLATION... 9 2 1420-SR001A-EN-P

SECTION XX XX XX POWER METER PART 1 GENERAL 1.01 SUMMARY A. The shall meet the criteria of this specification for energy monitoring. 1.02 RELATED DOCUMENTS A. Drawings and general provisions of the contract apply to this section. B. The following sections contain requirements that relate to this section: 1. Section 26 09 13 Electrical Power Monitoring and Control 2. Section 01 33 00 Submittal Procedures 3. Section 1.03 REFERENCES A. The power meter shall adhere to the following approvals: 1. culus Listed, File E56639. 2. CE marked. B. The power meter shall comply to: 1. Safety: IEC60664, IEC61010-1 EN60664, EN61010-1 EN62052. 2. Metrology: EN62053-21 EN62053-23, EN50470-3. MID annex MI-003. 3. Pulse output: DIN43864, IEC62053-31. C. The power meter shall meet the following standards: 1. ANSI C12.20-2010 Class 1 Clause 5.5.4 American National Standard for Electricity Meters accuracy and performance 2. EN 62053-21 -2003 Class 1 Accuracy Electricity metering equipment (AC) Static meters for active energy 3. 2006/95/EC: Low Voltage Directive 4. 2004/108/EC: Electromagnetic Compatibility (EMC) Directive 5. EN 61010-1:2001: Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements 6. EN 61326-1:2006 Electrical equipment for measurement, control and laboratory use EMC requirements 7. EN 61000-6-4:2001 Electromagnetic compatibility (EMC) Part 6-4: Generic standards Emission standard for industrial environments 8. EN 61000-6-2:2001 Electromagnetic compatibility (EMC) Part 6-2: Generic standards Immunity for industrial environments 1420-SR001A-EN-P 3

1.04 PRE-MANUFACTURE SUBMITTALS A. Refer to Section for submittal procedures. B. Product Data 1. Publications on power meter. 2. Data sheets on all furnished options. C. Installation Instructions 1. A copy of the manufacturer s installation instructions, including receiving, handling and storage instructions. 1.05 FINAL SUBMITTALS A. Refer to Section for procedure on submittal of final documentation. B. Supplier Certification 1. The supplier shall provide certification that the power meter settings have been properly adjusted. C. Maintenance Data 1. Power meter installation instructions and User Manual. 2. Parameter listing. 1.06 QUALITY ASSURANCE A. The supplier shall provide power meter system components by a single manufacturer: 1. Only communication modules for communication or network media functions that are not provided by the power meter manufacturer may be produced by third-party sources. 2. Only power meter manufacturer-approved hardware, including cables, mounting hardware, connectors, enclosures, racks, communication cables, splitters, terminators, taps and removable media, may be used. B. All power meter system components shall be new, free from defects and produced by manufacturers regularly engaged in the manufacture of these products. 1.07 DELIVERY, STORAGE AND HANDLING A. The supplier shall deliver power meter components in packaging designed to prevent damage from static electricity and physical damage. B. The supplier shall store the equipment according to manufacturer requirements and in a clean and dry space at an ambient temperature range of -30 to 70 C (-22 to 158 F). C. The supplier shall protect the components from exposure to dirt, water, fumes, corrosive substances and physical damage. 4 1420-SR001A-EN-P

1.08 WARRANTY A. The manufacturer shall provide their standard parts warranty for eighteen (18) months from the date of shipment or twelve (12) months from the date of being energized, whichever occurs first. B. This warranty applies to power meters. 1.09 MAINTENANCE A. As specified in Section. B. Provisions shall meet the following installed-spare requirements: 1. One spare set of fuses for each type used for the installation. 2. One spare shorting block for each type used for the installation. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Allen-Bradley PowerMonitor 500 (No substitutions) 2.02 CONSTRUCTION A. The power meter shall: 1. Connect to a three-phase or single-phase AC power system. 2. Measure electrical parameters. 3. Produce digital outputs that can be configured to annunciate alarms and to output a pulse proportional to the energy measured (optional). 4. Produce analog outputs (optional). 5. Communicate data to its integrated LCD display and, through optional communication ports, to compatible applications. B. The power meter shall have panel mounting capability for mounting on the flat surface of a suitable enclosure. 1. The front of the power meter shall provide IP65, NEMA 4X and NEMA 12 protection degree. 2. The enclosure shall protect: a) The back of the power meter from atmospheric contaminants. b) The user against personal contact with energized circuits. 3. The power meter shall be designed to operate in: a) An industrial environment with an ambient temperature of -25 to 55 C (-13 to 131 F), and with a relative humidity range of 0% to 90%, non-condensing. b) A free airflow environment (convection cooling only, no fans or other air moving devices shall be required). C. The power meter shall operate with control power electrical service of 90-260 VAC/VDC, 48-62 Hz. 1420-SR001A-EN-P 5

D. The power meter shall include adequate memory to store all necessary data. E. Front dimensions of the power meter shall be 3.78 inches x 3.78 inches (96 x 96 mm). F. Readily accessible on the front of the power meter shall be: 1. Active alarm status indicators. 2. Flashing Real Energy consumption rate status indicator. 3. LCD display and 4 interface buttons. G. Optional modules shall be available to provide: 1. Serial and Ethernet communication ports. 2. Digital and analog outputs. H. The back of the power meter shall provide terminals for voltage and current sensing and the power supply connection. I. Configuration shall be password-protected. 2.03 VOLTAGE AND CURRENT SENSING A. The power meter shall connect to a 3-phase or single-phase AC power system directly or through instrument transformers. B. The sensing connections shall be selected to match the configuration of the monitored circuit, including: 1. System 3-Ph.n, unbalanced load: 3-phase, 4-wire 2. System 3-Ph, unbalanced load: 3-phase, 3-wire 3. System 3-Ph.1, balanced load: 3-phase, 3-wire 4. System 3-Ph.2, balanced load: 3-phase, 2-wire 5. System 2-Ph: 2-phase, 3-wire 6. System1-Ph: 1-phase, 2-wire C. Current inputs shall be connected to current transformers to ensure isolation. D. Voltage sense inputs (V1, V2, V3) shall be rated: 1. One of two options: a) Line-Neutral 40 to 144V; Line-Line 70 to 250V b) Line-Neutral 160 to 480V; Line-Line 277 to 830V 2. Frequency: 40 to 440 Hz. 3. Overload withstand: 1.2 U n continuous, 2 U n for 1/2 sec. 4. Input impedance: 1.6 MΩ minimum. 5. Dielectric withstand: 4 kv. E. Current sense inputs (I1, I2, I3) shall be rated: 1. 5 A continuous current (6 A I max ) 2. Accuracy: a) From 0.01 to 0.05 I n : ±(1.0% of reading + 2 digit) b) From 0.05 I n to I max : ±(0.5% of reading + 2 digit) 3. Frequency: 40 to 440 Hz. 6 1420-SR001A-EN-P

2.04 FUNCTIONS 4. Overload withstand: 6 A continuous, 120 A for 1/2 sec. 5. Burden: 0.2 VA maximum. 6. Maximum crest factor at 15 A: 3.0. 7. Starting current: 5 ma. 8. Dielectric withstand: 4 kv. A. Measured parameters shall include maximum and demand values: Voltage Reactive power, kvar Current Apparent power, kva Frequency Power factor Voltage imbalance Real energy, kwh Real power, kw Reactive energy, kvarh B. Other functions shall include: Universal clock and calendar Digital filtering Display reset 2.05 DIGITAL AND ANALOG OUTPUTS (OPTIONS) A. Digital Outputs 1. The power meter shall have 2 available digital outputs which can be configured to work as alarm outputs, pulse outputs, communication-controlled outputs or any combination. 2. Digital pulse outputs shall be relay, SPDT type and rated: a) AC 1 to 5 A at 250 VAC b) AC 15 to 1.5 A at 250 VAC c) DC 12 to 5 A at 24 VDC d) DC 13 to 1.5 A at 24 VDC B. Analog Outputs 1. The power meter shall have 2 available analog outputs which can be configured to retransmit values for variable speed process control. 2. Analog outputs shall be rated: a) Range: 0 to 20 ma. b) Accuracy: ±0.2% 2.06 COMMUNICATION (OPTIONS) A. Using serial and network communications, the operator shall be able to: 1. View power and energy data. 2. Record data. 3. Control digital outputs. 4. Use data in compatible applications. 5. Communicate with compatible PLC families. 1420-SR001A-EN-P 7

B. The power meter shall have available: 1. Optional serial RS-232/RS-485 communications port, supporting Modbus RTU. 2. Optional Ethernet port, supporting EtherNet/IP and Modbus TCP. 2.07 CONFIGURATION A. The power meter shall have on-display, menu-based configuration. B. The display s programming mode shall step through menus (and their submenus), including: 1. Password protection 2. Backlight time adjust 3. System selection 4. CT and PT ratios 5. Calculation methods 6. Digital stabilization filter setup 7. Communication setups 8. Meter front virtual alarms 9. Digital and analog output setups 10. Energy meter setup 11. Clock setup C. The power meter shall integrate easily into existing information networks. 2.08 LCD DISPLAY AND INDICATORS A. The power meter shall have an integrated LCD display to provide viewing and configuration. 1. The operator input shall be 4 enhanced touch buttons: Exit, Up, Down, Program/Select. 2. The LCD display shall: a) Operate in 2 modes Metering and Programming. b) Show metering values 4 digits x 4 lines. c) Show energy value 10 digits plus sign. d) Indicate additional information and status using icons. B. Navigation on the power meter s application shall include: 1. In Programming mode stepping through menus for configuration and editing. 2. In Metering mode changing which data will be displayed and whether the values are maximum or demand. C. The power meter shall have: 1. 1 Real Energy consumption rate status indicator which flashes faster to indicate higher rate. 2. 4 red status indicators for configurable virtual alarms. The real alarms are the activation of the proper static or relay output if the optional module is available. 8 1420-SR001A-EN-P

2.09 GENERAL RATINGS A. The power meter shall be rated: Installation Category Electromagnetic Compatibility Noise Rejection CMRR Dielectric Withstand Material Cat. III (IEC60664, EN60664) EN6205211 100 db, 48 to 62 Hz 4 kv ABS, self-extinguishing: UL 94V-0 PART 3 EXECUTION 3.01 EXAMINATION A. The supplier shall verify that jobsite is ready to receive equipment. B. The supplier shall verify that the jobsite environment can be maintained during and after installation within the service conditions required by the manufacturer of the power meter. 3.02 INSTALLATION A. Installation shall be in compliance with all manufacturer requirements, instructions and contract drawings, including: 1. Space surrounding the power meter to maintain adequate cooling. 2. Conditioning of space surrounding the power meter enclosure to maintain the manufacturer s ambient temperature and humidity ranges. 3. Accessibility of power meter diagnostic lights and communication ports these components shall be free from obstructions at all times. B. Interface 1. The supplier shall provide all required cables and connectors to interface with other equipment. 2. The supplier shall coordinate size and configuration of enclosure to meet project requirements. 3. The supplier shall ensure that communication connections and wiring are properly protected in accordance with manufacturer recommendations. END OF SECTION 1420-SR001A-EN-P 9