Installation Notes: Axia StudioEngine v2.7.0k For Element Consoles

Similar documents
Telos Zephyr iport + TZD Software v2.1.3

Telos Zephyr iport + TZD Software v2.1.0 Update Instructions and Release Notes

Update Instructions: Axia xnode, xselector, xswitch With Release Notes and New Feature Instructions v1.6.4e

Axia xnode Software Package v2.0 Update Instructions & Release Notes

Nx Talkshow Systems Nx12, Nx6, iq6, and Hx6

IP High Quality Audio Broadcasting Server

IP Audio Broadcasting Terminal High Performance IP Audio Broadcasting Terminal

ProSAFE Plus Configuration Utility

Omnia VOCO Microphone Processor Software Package v1.39 Update Instructions & Release Notes-

SDI xnode. Livewire+/AES67 Audio over IP Interface with Dual HD/SD-SDI Ports. Quick Start Setup Guide For part numbers:

Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

Peplink SD Switch User Manual. Published on October 25th, 2018

GSS Administration and Troubleshooting

C8000. switch over & ducking

Omnia.11 Version 1.2 Update

WLM1200-RMTS User s Guide

ProSAFE Easy-Mount 8-Port Gigabit Ethernet PoE+ Web Managed Switch

ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.1

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418

Videon Product Manual

TelePresence MCU Hardware Troubleshoot Guide

Echo Digital Audio Corporation AudioFire 2 AudioFire 4 AudioFire 8 AudioFire 12 Release 4.6 for Mac OS X

Configuring and Managing the IP Camera

Audio Signage Solution

Echo Digital Audio Corporation AudioFire 2 AudioFire 4 AudioFire 8 AudioFire 12 AudioFire 8a AudioFirePre8 Gibson RIP Release 5.7.

Configuring the Cisco TelePresence System

TrangoLINK GigaPlus. Software v1.3.3 Release Notes & Upgrade Instructions. 16 December 2011

Z Series. Project Design Guide

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide

8-port mk2 user s guide v port mk2

APAD User Guide V1.0

TrangoLINK GigaPlus. Software v1.3.2 Release Notes & Upgrade Instructions. 3 October 2011

ProSAFE 8-Port 10-Gigabit Web Managed Switch Model XS708Ev2 User Manual

Cisco TelePresence ISDN Gateway Version 2.2

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3

AEQ CAPITOL SCREEN USER S MANUAL ED. 04/18 Firmware Version: PBA Base CPU v1.73 or higher Software Version: AEQ CAPITOL SCREEN v1.

ProSAFE 8-Port and 16-Port 10-Gigabit Ethernet Web Managed Switch Models XS708Ev2 and XS716E User Manual

GRANDSTREAM NETWORKS SUMMARY OF UPDATES. The main purpose of this release is bug fixes and feature enhancement.

8-Port Gigabit Ethernet Smart Managed Plus Switch with Integrated Cable Management User Manual

Version 4 Software. Version 4 - Supplement. Issue A, August 2007 for Version 4.0+ Software. D5 V4 Supp 1-1

AP-VR1000 Video Service Router

CM-series compact mixing consoles. User Manual

Echo Digital Audio Corporation AudioFire 2 AudioFire 4 AudioFire 8 AudioFire 12 Release for Mac OS X

Release Note for Vigor2820 Series

IP Audio Broadcasting Solution

HDx TDM Record/Playback Option Guide

RP-FSO522 2-Line FXO, 2-Line FXS SIP IP Gateway. Feature

ZED / Sonar Trouble shooter

8-Port Gigabit Ethernet Smart Managed Plus Switch with Integrated Cable Management User Manual

ilive and T Series RELEASE NOTES Version 1.54 Iss.1 CD 24/11/09 V1.54 is a maintenance release of the ilive and T Series system firmware.

ACCREDITED SOLUTION. EXPLORER 500 COMREX ACCESS Rack Stereo BRIC IP Codec

VE6023 Telephone Page Server User Manual

Release notes for Version of HMX Extenders

IP Utility. User s Manual For Version

Axia iqx. Installation & User s Guide. AES67 Console with Integrated Engine. Version 1.0 November, USER MANUAL: AXIA IQX

V-Tap VoIP Manual V1.0. V-Tap VoIP Manual EN 2017 Vidicode 1

Quick Start Guide MU120131A/32A. IP Multicast Measurement MD1230B/MP1590B. Data Quality Analyzer / Network Performance Tester

GreenEye Monitor. GEM Communication Setup Manual. For GEM model: GEM-W. (Wifi Only Option)

see the Cisco SPA100 Series Administration Guide for details. The configuration profile is uploaded to the Cisco SPA122 at the time of provisioning.

VIDEO GRABBER. DisplayPort Standard. User Manual

AXIS T85 PoE+ Network Switch Series. AXIS T8524 PoE+ Network Switch. AXIS T8516 PoE+ Network Switch. User Manual

CHAPTER 7 ADVANCED ADMINISTRATION PC

DVS-200 Configuration Guide

ProCurve Switch G ProCurve Switch G

Troubleshooting. Introduction CHAPTER

TITLE Software Release Notes, LS10 V CREATED BY: L. Brown

FREUND SIP SW - V SIP-server setup

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver

The Avocent HMX Advanced Manager. Installer/User Guide

AP-VR2000 Video Service Router High-performance Multimedia Gateway Solution

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Light Mesh AP. User s Guide. 2009/2/20 v1.0 draft

Configuring General Settings for the EN-4000

Vodafone MachineLink 3G Plus

Configuring the IP Settings

Configuring attack detection and prevention 1

960L Software Version 3.0

Chapter 4 Software-Based IP Access Control Lists (ACLs)

Previous LS9 Firmware version information

SET-UP INSTRUCTIONS. How can the DB9000-TX be used as an Icecast Source Client, sending audio to DB9000-RX decoder used as an Icecast Source Server

AVAYA Avaya Aura System Platform Service Pack R6.2.1 Release Notes Issue 1.3

NOTE: There are two different installation methods dependent upon the manufacture date.

Troubleshooting VoIP in Converged Networks

Logitek Electronic Systems. vtools Reference Manual

AEQ FORUM VIRTUAL USER S MANUAL ED. 03/15 Firmware Version: PBA Base CPU v1.65 or higher Software Version: AEQ FORUM VIRTUAL v1.

TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 1.0.0

Configuring attack detection and prevention 1

The Applications and Gaming Tab - Port Range Forward

FREUND SIP SW - V Intercom Setup

AP-MC1500 Audio MCU(Multipoint Control Unit) High-performance Audio MCU Solution

8-Port Gigabit Ethernet Smart Managed Plus Switch with 2-Port 10G/Multi-Gig Uplinks User Manual

Essential Connections You will need to connect the following things to get started:

Quick-Start Installation Guide

CM SERIES. Compact Live and Studio Mixers. Item ref: UK, UK, UK, UK, UK, UK User Manual

Videon Product Manual. Shavano Encoder

i-series Extender 4000

User guide. ApplianX DPNSS-to-Q.SIG Gateway

Chapter 2. Switch Concepts and Configuration. Part I

Troubleshooting. General Troubleshooting Information

Transcription:

Installation Notes: Axia StudioEngine v2.7.0k For Element Consoles Revised March 2, 2015 Software Version Compatibility Element: 2.5.0.9 or later Livewire : or later IP Audio Driver 2.4.8.12 or later Summary of new features: CPU usage optimization, reduced control latency Important Update Notice: Read before Proceeding! This update requires that your StudioEngine have a certain level of software already installed prior to upgrading. You must have v2.6.4n (or higher) installed in order to upgrade to v2.7.0k. If your engine is already running version 2.5.4a or newer, then you may proceed with updating to 2.6.4n by following the links to the correct file for your hardware listed below. If your Engine is running a software version PRIOR to v2.5.4a, please contact Axia Support for help with your upgrade. Please consult with Axia before installing any updates if you: have received pre-release samples or non-standard units, have modified them in any way, other than installing officially released software updates, are unclear on exactly what is needed.. Prior to performing any software update, you should always navigate to the Engine s System page and save your current configuration. Determine Your StudioEngine Hardware Platform There are several variations of StudioEngine hardware in the field. Check the information provided below to be certain you are applying the correct update. If you have any questions about which hardware you have, please contact Axia Support for help. Update Instructions If using Axia iprobe Network Management Software to update: Click the Engine you wish to update, and follow iprobe s instructions for updating. You may choose to apply the update to a single Engine, or to all Engines on your network. If updating using a PC connected to your Livewire network and a Web browser: 1. For Intel Pentium 4 StudioEngine running Engine software v2.5.4a or later: download 1601-00504-006-Engine_P4-2.7.0k.tar from ftp://ftp.zephyr.com/pub/axia/updates/engine/. Save the file to an easily-accessed folder. Note that 2.7.0k requires 2.6.4n to be installed first. If needed you may download it from

ftp://beta.zephyr.com/~tlscorp/pub/axia/updates/engine/sw_updates/cf_type2/pentium4/1601-00504-005(enginep4_2-6-4n_upgrade).tar 2. For all other StudioEngine hardware platforms running Engine software v2.5.4a and later: download 1601-00534-006-Engine-2.7.0k.tar from ftp://ftp.zephyr.com/pub/axia/updates/engine/. Save the file to an easily-accessed folder. Note that 2.7.0k requires 2.6.4n to be installed first. If needed you may download it from ftp://beta.zephyr.com/~tlscorp/pub/axia/updates/engine/sw_updates/cf_type2/core_core2/160 1-00510-005(engineCore_2-6-4n_upgrade).tar 3. Using your Web browser, type the IP address of your StudioEngine into the address bar and log in if necessary. 4. Once logged in, navigate to the System page. 5. Commit the existing software version if that option is available. Software may remain in Bank 1; however, you will get an empty entry field below Bank 1 where you can browse/select a new version for upload. 6. Locate the update package you saved in Step 1, and upload it. Any existing version in Bank 1 will be overwritten. When the software has been received by the Engine, check the Version ID line next to the Bank 1 bullet - you should see [2.7.0k] displayed there. 7. Select Bank 1, containing the new Version 2.7.0k software, and select Apply selected bank. 8. After reboot, the engine should be operating from Bank 1 with the new software version installed. If you have trouble at any point during the upgrade process, please contact Telos Alliance Support at www.telosalliance.com/support-request or by telephone at +1 (216) 241-7225.

Prior Version Release Notes Engine version 2.7.0k release notes Element application 2.5.0.9 Internal optimization to reduce control latency and CPU usage. Moves the RPL attributes page to the Diagnostics tab, and adds meter control data to RPL attributes page. Bug Fixes Fixed possibility of incomplete source list on Intercom configuration page. Fixed possibility of slow routing/command execution time. Fixed a problem that resulted in V-Mixer and V-Mode stream advertisements not showing after restart. Fixed a condition that resulted in StudioEngine not sending IGMP membership reports for its own generated streams. Various other internal optimizations and bug fixes. Engine version 2.6.1e release notes Element application 2.3.1.0 Adds support for new fanless Engiine hardware platform Complete iprobe support - source info, software updates, configuration backup/restore Intercom service update installation Bug Fixes Silence alarms and metering now work for all VMIX channels EQ - Mid Gain now correctly affects frequencies from 1.6kHz - 2kHz Setting the Element mixing mode to stereo no longer defeats VMODE surround Outputs disabled due to overload no longer appear available on the network Corrupted software banks now clear after application of software update Engine version 2.5.4e release notes Element application 2.3.1 Fixed public release defects:

Fixes instability and restart issues when number of outputs enabled exceeds 118 streams. CPU Resource monitoring now correctly tracks output streams and disallows overloading. Engine version 2.5.4a release notes Element application 2.3.1 Web - option to change the default buffer size for Standard streams Ping client and sshd enabled Multi-partition CF image for Intel and ASUS motherboards Improved software upload procedure - accepts packages in.tar format and works faster Automatically switches to second code bank in the event of primary bank boot failure Diagnostics enhancements - watchdog monitoring, software upload log, boot monitoring UDP packets can now be sent to hosts behind the router, allowing the engine trace log to be stored on a host outside the engine local network. Fixed public release defects: Fader trim gain no longer has an effect on the Preview level. LWRP Removed space padding in the NAME bracket. LWCP Fixed consdition wherein, If LOGIN was not sent as the first command in a session, it would not work afterwards Fixed missing IGMP LEAVE request after a local audio loopback is disconnected VMode and VMix - Fixed a condition wherein some saved states were not retained after reboot. PLL state stabilized. SmartSurface mode fixed Program and Monitor output configurations improperly retained after reboot. Known issues: CPU load measurement is no longer accurately recorded. For safety, maintain a load limit between 70-75% on the load meter. Engine version 2.5.1w release notes Element application 2.3.1 VMODE audio mode configuration now includes graphics to visualize the audio flow Doubled the number of VMIX/VMODE blocks Preview speakers - factory default stream mode is now "Live", not "Standard" Added Intercom application module - v 1.2

Config backup/restore/reset now includes the Intercom settings Fixed public release defects: Improved RFC host name compliance Event handling improved for Engine PING non-response when audio multicast is still working Ethernet driver - removed unneeded diagnostic output VMODE - standard stream in the second position of a pair: fixed meter function when for operations where the first output in this pair is disabled Added value limiting at stream output; fixes high aggregate gain in audio path which may lead to distortion caused by sample value overflow Removing a duplicate Livewire stream from an active output no longer disconnects a valid input stream. Engine version 2.4.10k1 release notes Element application 2.2.0.9 SmartSurface application 2.5.0.59 Multi-standard audio level meters Changed: Web - modify the visual look to match the "Axia style" as defined by Element Supporting bigger consoles up to 64 faders LWRP - DST command is memorized in config data to support PF changes Improved: Refinements to operative accounting and allocation of CPU resources - thresholds adjusted to prevent the CPU load exceeding 90% - resource availability check applied to basic fader channel source processing - resource availability check applied to source backfeeds Generates a syslog event when I/O stream is automatically disabled in result of switching the network port from 1G to 100M LWCP - memorizes all commands in the permanent configuration Changed: Web - Move syslog configuration from the ID page to the Diagnostics page; engine and console ID pages become "Network" Changed: LWRP - DST port numbering - append faders 29..64 at the end of the former numbering range (solves the PathFinder compatibility problem that emerged in the preliminary release 2.4.9) Full SmartSurface compatibility - build 2.4.10e3 approved Preview: Pre-fader listen / after-fader listen mode switching

Changed: New, more robust debug log control approach: - an active client configures the target IP and detail level via network link, and pulls the log without involving the configuration web page - debug level is now stored on CF, that allows to obtain the startup phase log in field as well Changed: Factory netmask changed to 255.0.0.0 Changed: Automatic config backup file name - include two lower IP address bytes Changed: CMsg supv polling - move responses to unicast, insert randomized response delay, adjust timers to polling interval 4sec Should a network driver crash occur, crash investigation info would be saved on a controlled unit shutdown: Improved: Advertisement channel optimization, adv protocol version 3 - step 1 Web - reset stream statistics counters Changed: Move the pre-fader gain control CHxx.FATG to the point immediately after the CHxx.MODE switch Changed: Front panel - if more than one error condition existed at a time, the second error message would never go away Source sharing - SmartSurface compatibility mode - fixed redundant SRC reports on port 93 Source advertising - "To source" streams may be missing their names in adv messages Source advertising and console supervision did not work if the Gateway IP is left blank Eliminated the redundant manual Element/SmartSurface API mode switching VMIX - if a mixer's I/O was disconnected, after restarting the engine the former ON states of inputs would be lost in the DSP - although the controls are still displayed in the "ON" state, actually they will not pass audio. Web - "Omnia Processing" configuration LWRP - Stopping audio on PGM 4 causes a false silence report on VMIX1 sub Instability caused by insufficient buffer amount between network driver and standard Linux VMIX gain is interpreted incorrectly if more than one digit was entered after the point Channel numbers of disabled outputs were lost after restart

Engine version 2.4.9r6 (and previous) release notes Element application 2.1 SmartSurface application 2.5.0.59 2.5.2 New: Major operation environment rework: Suse Linux with multi-core kernel, GRUB boot loader New multi-partition CF storage structure, OS moved into the dual code bank, software update installation by complete bank rewrite Omnia headphone processing can now be applied to either PGM1 or Mon1 Headphones. Users can now set a password for remote access via HTTP using a field on the Engine s Configuration pages (replacing previous versions Telnet configuration for this option). Maximum mix-minus audio gain trim has been increased from -3dB to -6dB to allow adequate attenuation of summed dual-mono backfeeds. Gain control for Aux mix level compensation in mix-minus backfeeds Gain Control for Pre-fader gain trim Gain Control to trim Mic output levels after Omnia Mic processing is applied New metering capabilities providing 10 switchable full-resolution meters SmartSurface compatibility mode option for source sharing. Users can now switch all engine sources between freely sharable, (SmartSurface compatibility mode), and lockable (normal Element operation). Find the new option in the "Application Interface Options" section of the HTTP configuration pages. When operating in Surround mode, upmixes from L, R, L+R and stereo no longer send L and R to LFE channel. After moving the engine from a 1Gig to a 100Mbps switch port and restarting, the number of active outgoing audio streams is now properly limited to match available bandwidth. Source is Busy error that caused Engine sources to be unavailable for assignment on SmartSurface faders. Bug that might cause slow resumption of audio after connection to console. Version 2.4.8w3 Element application 2.0.0r12 SmartSurface application not recommended 2.3.3b2 V-Mixer and V-Mode full local control via engine web page, destination routing control via LWRP, mixing control and mode selection via LWCP. Source sharing logic is now fully supported; source advertisement logic now allows creating backfeeds for engine outputs. Audio level meters now provide true peak value with hold function for the refresh period, and standard 300ms average RMS. Omnia headphone processing. New presets, tweaked parameters and eliminated processing bugs Extended EQ frequency ranges. Automatic upmixing to surround. LWRP server bugs. Slow show profile loading. A number of other minor and cosmetic enhancements and bug fixes. Version 2.4.7e2 Software version compatibility Element application 1.1.13.13a SmartSurface application 2.50.59

2.3.3b IP audio driver Windows 2.4.7.3 Automatic updating of MAC address mapping for known IP Mon1 headphones - new Hot HP Omnia dynamics preset Syslog event reporting of stopped/resumed streams, unwanted streams, stream conflicts Mon1 headphones - Omnia - AGC drive and mixer - Mid and High bands appeared cross-connected Version 2.4.7c5 Mic and Headphones control accessory module - phase2: source name display on engine, presentation on web page and front panel. Logging unwanted multicast to detect flooding The stream number limit for 100 Mbps links is now correct Trace log defects in diagnostics logging routines Source loading speed Individual headphones - volume control now works Individual headphones - external source selection now works Version 2.4.6f1 Mic and Headphones control accessory module - phase2: Implemented volume control. Must use Element ver 1.1.13x or higher (still in testing) Mon1 HP Omnia processing - meters - interface for enabling/disabling and setting the remote IP address Known bug here: Wrong IP address range check causes meters to not work if the remote IP is set >= 128.x.x.x Improvement: Advertising discipline - insert a delay before sending advert messages on source changes Version 2.4.6d8 Dynamics processing in headphones - Phase 1: Enabled processing in the CR HP path Full list of Omnia A/X presets is offered. factory-defined, currently selectable from Engine web page only Engine - SPLITTING the RECORD bus Health monitoring functions - support for motherboard Web - system status - show fan speed measurement Improvement: Diagnostics interface improvements Front Panel - VMIX - Output page does not automatically follow value changes Source name for RECORD should be "Program 4 Record", not "Program 3 Record" VMIX outputs: Pathfinder sees them listed even if they are OFF V-Mixer - source name is shown only if the input was idle before Front panel - PGM and Monitor I/O, VMIX I/O screens - audio level indicators do not work Config backup, executed immediately after entering new output channel numbers, returns them to old values Fader channel - AUX SEND pre/post-fader - inconsistent startup defaults Version 2.4.5b1 Engine returns wrong backfeed presence status - "disconnected" for existing backfeeds Version 2.4.5b Added/Changed: Program 4 split to two streams, Stream Program 4 now follows Post ON/OFF, Post Fader. Stream called Program 4 Record replaces previous Program 4 functionality of Pre ON/OFF, Post Fader operation. Improvement/Changes: PHONE and RECORD mixing buses in Element mode Phone Bus- Follows Program 4 selection and is Pre ON/OFF, Pre Fader. Internal to Engine only. Feed to source option PHONE changed from Program 1 feed to follow Phone buss now. Feed to source option AUTO now follows rules for channel ON/OFF to feed Pgm 1/Phone Bus to backfeed of Phone and Codec sources Changed: V-Mixer - default output channel numbers: main 201, Submix 1 faders 211-215, Submix 1 Out 1 216, Submix 2 faders 221-225, Submix 2 out 226, Changed: Startup defaults for console type and output channels must be for Element console

Improvement: Phone and codec - feed to source - 3dB level compensation for mono sum Health monitoring functions for Motherboard Changed: The "OFF" command (shut down and halt) is redundant as it results in restarting the engine Version 2.4.5a1 and previous V-Mixer added to Engine. Requires Element version 1.1.11x and higher. glitching with Element's voice processing, Fixed code and made Compressor Attack faster Fader channel - PGM4 pre/post-on - startup default must be post-on Backward feed source select - Aux1..Aux4 do not work (Element can use these only starting from release 1.1.10) Headphone backfeed levels from the engine to any Mic Position are at reduced levels Mic processing - gain reduction meters not working if signal is present only in one of stereo channels Engine diagnostics interface improvements - new events in the trace log file New source type COMPUTER Wrong number of sources (NUMS) in adv messages after switching between different console types On enabled outputs, the LW channel numbers cannot be changed At startup, engine does not detect- unplugged network cable and Half Duplex error Improper watchdog handling at application shutdown causes failures to install further software updates Surround PAN control on Aux returns Monitor source select - P1..P4, Aux1..Aux4, Ext1, Ext2 Feed to source options added P3, P4, A1..A4 Code to support new meter source select options - MET2/4.SRSW to RECORD Front panel passcode. Accessible from System Web Page Code to support new Mic and Headphones control accessory modules, Phase 1 Improvement: Improved Engine diagnostics options Fader channel's stereo PAN (SmartSurface mode)- wrong state when loaded by show profile