Selection guide TeSys Model U 0 Starter-controllers Control units

Similar documents
Telemecanique TeSys Model U the ultimate starter-controller. Catalogue

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

TeSys model U Motor starters - open version

3 Pole Contactors with AC operating coils

TeSys IEC Contactors and Overload Relays

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

TeSys contactors From 115 to 2750 A

U-Line Motor Starters

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RM4TR31 three-phase network control relay RM4-T - range V

TeSys protection components

RM4TA32 three-phase network control relay RM4-T - range V

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

TeSys U LUTM Controller

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

TeSys U LUTM Controller User Manual 03/

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

RM4JA01F current measurement relay RM4-J - range ma V AC

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

RM4JA31M current measurement relay RM4-J - range ma V AC

K-Line Mini - Contactors, Overload Relays and Accessories

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

LUTM TeSys Model U Controller User s Manual 02/2005

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

Zelio Control-modular measurement and control relays 1

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

Circuit Breakers Type CTI 25M, CTI 45MB

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

TM221M16TG controller M IO transistor PNP spring

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

TM221M16R controller M IO relay

Starter-controller TeSys U Change to higher speed

RM4UA33M voltage measurement relay RM4-U - range V V AC

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

TM3SAF. Main. Device short name

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

TM221M32TK controller M IO transistor PNP

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM35TF V AC

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

TM241C40U controller M IO transistor NPN

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

Motor protection relays

TM241C24T controller M IO transistor PNP

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

The technical guide TeSys D

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module

TM221CE40R controller M IO relay Ethernet

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Contact protection relay

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

TM3AI4 module TM3-4 analog inputs

Transcription:

Selection guide TeSys Model U 0 Control units Function characteristics Control units Standard Advanced Multifunction LUCA LUCB LUCC LUCD LUCM Thermal overload protection Overcurrent protection 4. x the setting current 3 to 7 x the setting current Short-circuit protection Protection against phase loss 4. x the max. current Protection against phase imbalance Earth fault detection (equipment protection only) Tripping class 0 0 0 5 30 Motor type 3-phase Single-phase 3-phase Single-phase and 3-phase Thermal overload test function Overtorque No-load running Long starting times Reset mode Manual Parameters can be set Automatic or remote With function module or parameters can be set via the bus with a communication module, see chart below. Parameters can be set Parameters can be set via the bus with a communication module (see below). Alarm "Log" function Thermal overload alarm only with function module or communication module, see below.l Possible for each type of fault. Indication on front panel of the control unit, via remote terminal, via PC or via PDA (). With communication modules to make use of these alarms via a bus, see below. Log of the last 5 trips. Number of starts, number of trips, number of operating hours. "Monitoring" function Indication on front panel of the control unit via remote terminal, via PC or via PDA (). With function modules () Thermal overload alarm Fault differentiation and manual reset Fault differentiation and automatic reset Indication of motor load (analogue) With module LUF W With module LUF DH0 With module LUF DA0 With module LUF V With communication module or via Modbus port on control unit LUCM () Starter status (ready, running, fault) Reset mode Alarm Remote reset via the bus Indication of motor load Fault differentiation Remote programming and monitoring of all functions "Log" function "Monitoring" function With any communication module Parameters can be set via the bus With module Modbus LUL C03 (thermal overload alarm only). With Modbus module LUL C03 and Modbus port on the control unit (alarm possible for all types of fault). With Modbus module LUL C03 and Modbus port on the control unit. Built-in function Function provided with accessory () PDA : Personal Digital Assistant. () Mounting possibilities: function module or communication module. 8

References TeSys Model U 0 Standard and advanced control units 530655 5 Description Extraction and locking handle Test button (on advanced control unit only) 3 Ir adjustment dial 4 Locking of settings by sealing the transparent cover 5 Sealing of locking handle Standard control units 50735 LUCA pppp LUCB pppp 4 3 Maximum power ratings of standard 3-phase motors 50/60 Hz Setting range Clip-in mounting on power base Rating Reference to be completed by adding the voltage code () Weight 400/ 45 V 500 V 690 V kw kw kw A A 0.09 0.5 0.6 and 3 LUCA X6pp 0.35 0.5 0.35.4 and 3 LUCA Xpp 0.35.5. 3.5 5 and 3 LUCA 05pp 0.35 5.5 5.5 9 3 and 3 LUCA pp 0.35 7.5 9 5 4.5 8 3 LUCA 8pp 0.35 5 5 8.5 8 3 3 LUCA 3pp 0.35 Advanced control units Pressing the Test button on the front panel simulates tripping on thermal overload. Class 0 for 3-phase motors 0.09 0.5 0.6 and 3 LUCB X6pp 0.40 0.5 0.35.4 and 3 LUCB Xpp 0.40.5. 3.5 5 and 3 LUCB 05pp 0.40 5.5 5.5 9 3 and 3 LUCB pp 0.40 7.5 9 5 4.5 8 3 LUCB 8pp 0.40 5 5 8.5 8 3 3 LUCB 3pp 0.40 LUB p + LUCA pppp Class 0 for single-phase motors 0.5 0.6 and 3 LUCC X6pp 0.40 0.09 0.35.4 and 3 LUCC Xpp 0.40 0.55.5 5 and 3 LUCC 05pp 0.40. 3 and 3 LUCC pp 0.40 4 4.5 8 3 LUCC 8pp 0.40 7.5 8 3 3 LUCC 3pp 0.40 50736 Class 0 for 3-phase motors 0.09 0.5 0.6 and 3 LUCD X6pp 0.40 0.5 0.35.4 and 3 LUCD Xpp 0.40.5. 3.5 5 and 3 LUCD 05pp 0.40 5.5 5.5 9 3 and 3 LUCD pp 0.40 7.5 9 5 4.5 8 3 LUCD 8pp 0.40 5 5 8.5 8 3 3 LUCD 3pp 0.40 () Standard control circuit voltages : Volts 4 48 7 0 40 c BL (), (3) a B c or a ES (4) FU (5) () Voltage code to be used for a starter-controller with communication module. (3) d.c. voltage with maximum ripple of ± 0 %. (4) c : 48 7 V, a : 48 V. (5) c : 0 0 V, a : 0...40 V. LUB p + LUCB pppp Characteristics : pages 34 and 35 pages 50 to 54 Schneider Electric 9

References TeSys Model U 0 Multifunction control units 50737 530656 LUCM ppbl 4 6 3 5 Description Extraction and locking handle Built-in display window ( lines, characters) 3 4-button keypad 4 c 4 V auxiliary power supply 5 Modbus RS485 communication port. Connection by RJ45 connector. 6 Sealing of locking handle The display window and keypad 3 allow : b in configuration mode: local configuration of protection functions and alarms, b in run mode: display of parameter values and events. The Modbus communication port 5 is used to connect : b an operator terminal, b a PC, b a Personal Digital Assistant (PDA). Multifunction control units Parameter entry, monitoring of parameter values and consultation of logs are carried out : b either on the front panel, using the built-in display window/keypad, b or via an operator terminal, b or via a PC or a PDA with PowerSuite software, b or remotely, via a Modbus communication bus. Programming of the product via the keypad requires a c 4 V auxiliary power supply. Maximum power ratings of standard 3-phase motors 50/60 Hz Setting range Clip-in mounting on power base Rating Reference () Weight 400/ 45 V 500 V 690 V kw kw kw A A 0.09 0.5 0.6 and 3 LUCM X6BL 0.75 0.5 0.35.4 and 3 LUCM XBL 0.75.5. 3.5 5 and 3 LUCM 05BL 0.75 5.5 5.5 9 3 and 3 LUCM BL 0.75 7.5 9 5 4.5 8 3 LUCM 8BL 0.75 5 5 8.5 8 3 3 LUCM 3BL 0.75 LUB p + LUCM ppbl TeSys model U user's manual () Application Language Reference Weight On CD-Rom Multi-language (3) LU9 CD 0.0 5335 XBT NU400 Operator terminal This compact Magelis terminal enables the parameters of multifunction control unit LUCM to be read and modified. It is supplied pre-configured to provide dialogue with 8 model U starter-controllers (Modbus protocol, application pages and alarm pages loaded). Starter-controller alarm and fault management takes priority. Language Display window Supply voltage Reference Weight Multi-language (3) 4 lines of 0 characters c 4 V XBT NU400 0.50 Connecting cable (4) Function Length Type Reference Weight Connects terminal XBT NU400 to a multifunction control unit..5 m SUB-D 5-way female - RJ45 XBT Z938 0.00 () Input voltage c 4 V with maximum ripple of ± 0 %. () The CD-Rom contains user's manuals for the AS-Interface and Modbus communication modules, multifunction control units and gateway modules, as well as the gateway programming software. (3) English, French, German, Italian, Spanish (4) If a terminal is used with several control units, this cable can be connected to a Modbus hub or to T-junctions (see page 3). Characteristics : pages 34 and 37 pages 50 to 54 0 Schneider Electric

References TeSys Model U 0 Function modules Function modules Output Item Application Reference Weight Fault differentiation and manual reset This module differentiates short-circuit and thermal overload faults. It includes a contact for each of these types of fault. It can only be used with an advanced control unit, from which it takes its power. N/O with common point a or c 4 50 V LUF DH0 r 0.060 599 Fault differentiation and automatic reset This module signals a thermal overload fault. It includes an overload fault contact. Short-circuit signalling can be obtained by using an add-on fault signalling contact LUA (see page 6). It can only be used with an advanced control unit, from which it takes its power. In the event of tripping on thermal overload, the control unit is forced to automatic reset mode. In the event of tripping on short-circuit, the control unit is forced to manual reset mode. LUB p + LUCB pppp + LUFW 0 or LUF Vp N/O a or c 4 50 V LUF DA0 r 0.055 Thermal overload alarm Through load shedding, this module makes it possible to avoid stoppages in operation due to overload tripping. Imminent thermal overload tripping is displayed as soon as the thermal state exceeds the threshold of 05 % (hysteresis = 5 %). Signalling is possible via an LED on the front panel of the module and externally by a N/O relay output. It can only be used with an advanced control unit, from which it takes its power. N/O a or c 4 50 V LUF W0 0.055 507 % 00 00 3 0 ma 0 V 4 0 ma. kw 4 kw 3 7.5 kw Indication of motor load This module provides a signal which is representative of the motor load status (I average/ir). b I average = average value of the rms currents in the 3 phases, b Ir = value of the setting current. The value of the signal (4-0 ma) corresponds to a load status of 0 to 00 % (0 to 300 % for a single-phase load). It can be used with an advanced or multifunction control unit. The module LUF V requires a c 4 V external supply. 4-0 ma LUF V 0.050 Other versions Application modules which allow the starter-controllers to provide preset logic functions and eliminate the need for additional auxiliary functions : b module dedicated to measuring, b module for non-reversing applications (e.g. : pumping, ventilation), b module for reversing applications (e.g. : mechanical handling). Please call our Customer Information Centre on 0870 608 8 608. r Available nd half of 004. Characteristics : pages 34 and 39 pages 50 to 54

Presentation TeSys Model U PowerSuite software workshop advanced dialogue solutions 5389 Presentation The PowerSuite software workshop, for PC or Pocket PC, is designed for setting up Telemecanique starters and variable speed drives. This single program is an easy-to-use interface for configuring Altistart and Tesys model U starters as well as all Altivar drives in a Microsoft Windows environment, in five languages (English, French, German, Italian and Spanish). 5380 PowerSuite with PC screen Installation management Functions The PowerSuite software workshop can be used for preparing, programming, setting up and maintaining Telemecanique starters and variable speed drives. The PowerSuite software workshop can be used: b stand alone to prepare and store starter or drive configuration files, b connected to the starter or drive to: v configure, v adjust, v monitor (except for Altivar drives), v control (except for Altivar drives), v transfer and compare configuration files between PowerSuite and the starter or drive. The configuration files generated by the PowerSuite software workshop can be: b saved to hard disk, CD-Rom, floppy disk, etc... b printed, b exported to office automation software applications, b exchanged between a PC and a Pocket PC using standard synchronization software. PowerSuite PC and Pocket PC configuration files have the same format, b they are password protected. The software associated with the Altivar 3 has been enhanced to include: oscilloscope function, parameter name customisation, creation of a user menu, creation of monitoring screens, searching and sorting on different parameters. The PowerSuite software workshop has on-line contextual help. 53440 PowerSuite with PC screen Monitoring screen Connections b The PowerSuite software workshop can be connected directly to the terminal port on the starter or variable speed drives, via the serial port on the PC or Pocket PC. Two types of connection are possible: - either with a single starter or drive (point to point connection) - or with a group of starters or drives (multi-point connection). b The PowerSuite software workshop for PC can be connected to an Ethernet network. In this case the starters and drives can be accessed using: - either an Ethernet-Modbus 74 bridge CEV 300 0, - or a communication option card VW3 A5830 (for Altivar 38, 58 and 58F drives only). PowerSuite with Pocket PC screen Hardware and software environment b The PowerSuite for PC software workshop can operate in the following PC environments and configurations: v Microsoft Windows 95 OSR, Microsoft Windows 98 SE, Microsoft Windows NT4 X SP5, Microsoft Windows Me, Microsoft Windows 000, Microsoft Windows XP, v Pentium III, 800 MHz, hard disk with 300 Mb available, 8 Mb RAM, v SVGA or higher definition monitor b The PowerSuite for Pocket PC software workshop, version V.0.0, is compatible with Pocket PCs equipped with Windows for Pocket PC 00 or 003 operating system and an ARM or XSCALE processor. Performance tests for version V.00 of the PowerSuite software workshop have been carried out on the following Pocket PCs: v Hewlett Packard IPAQ 0, v Compaq IPAQ series 3800 and 3900, v Hewlett Packard Jornada series 560.

References, compatibility TeSys Model U PowerSuite software workshop advanced dialogue solutions References PowerSuite software workshop for PC or Pocket PC () Description Composition Reference Weight PowerSuite for PC kit b PowerSuite CD-Rom b PC connection kit. VW3 A80 0.400 PowerSuite for Pocket PC kit () b PowerSuite CD-Rom, b Pocket PC connection kit. VW3 A80 0.400 56309 PowerSuite CD-Rom b Software for PC and Pocket PC in English, French, German, Italian and Spanish, b technical documentation and ABC configurator program. VW3 A804 0.00 VW3 A80 PowerSuite upgrade CD b Software for PC and Pocket PC in English, French, German, Italian and Spanish, b technical documentation and ABC configurator program. VW3 A805 0.00 56300 VW3 A80 PC connection kit Pocket PC connection kit () b x 3 m connection cables with x RJ 45 connectors, b RJ 45/9-way SUB-D adapter for connecting ATV 58/58F/38 drives, b RJ 45/9-way SUB-D adapter for connecting ATV 68 drives, b converter marked RS 3/RS 485 PC with one 9-way female SUB-D connector and one RJ 45 connector, b converter for ATV drives, with one 4-way male connector and one RJ 45 connector. VW3 A806 0.350 b x 0.6 m connection cables with x RJ 45 connectors, b RJ 45/9-way SUB-D adapter for connecting ATV 58/58F/38 drives, b converter marked RS 3/RS 485 PPC with one 9-way male SUB-D connector and one RJ 45 connector, b converter for ATV drives, with one 4-way male connector and one RJ 45 connector. VW3 A8 0.300 () To find out about the latest available version, please call our Customer Information Centre on 0870 608 8 608. () These kits connect to the synchronization cable, which must be ordered separately from your Pocket PC supplier. Compatibility Compatibility of the PowerSuite software workshop with starters and variable speed drives Startercontroller TeSys model U PowerSuite software workshop with serial link for PC Kit and CD-Rom VW3 A80 VW3 A804 VW3 A805 PowerSuite software workshop with Ethernet link for PC Kit and CD-Rom VW3 A80 VW3 A804 VW3 A805 u V.50 and Ethernet- Modbus bridge PowerSuite software workshop for Pocket PC Kit and CD-Rom VW3 A80 VW3 A804 VW3 A805 Soft start/ Variable speed drives soft stop unit ATS 48 ATV ATV 8 ATV 3 ATV 38 ATV 58 ATV 58F ATV 68 u V.40 u V.30 u V.40 u V.0 u V.0.0 u V.40 u V.0 u V.50 u V.50 and Ethernet- Modbus bridge u V.0.0 and Ethernet- Modbus bridge u V.50 and Ethernet V communication card or bridge u V.50 u V.30 u V.40 u V.0 u V.0.0 u V.40 u V.0 Compatible products and software versions. Non compatible products. Compatibility of the PowerSuite software workshops with Pocket PCs Operating system Performance tests carried out on models PowerSuite software version V.30 V.40 V.50 V.0.0 Windows for Pocket PC 003 Hewlett Packard IPAQ 0 no no no yes Windows for Pocket PC 00 Compaq IPAQ series 3800, 3900 no no yes yes Hewlett Packard Jornada series 560 no yes yes yes Windows for Pocket PC 000 Hewlett Packard Jornada series 55 yes yes yes no Windows CE Hewlett Packard Jornada 40 yes no no no 3

Presentation, combinations TeSys Model U 0 Controllers Presentation The TeSys model U starter-controller provides Total Coordination to IEC/EN 60947-6- under overcurrent conditions up to 50kA at 400V for motor loads up to 3A. This standard provides for continuity of service with no welding of the main poles being permitted under short circuit conditions. Above 3 A, the model U controller provides a motor starter management solution identical to that provided by TeSys model U starter-controllers. Used in conjunction with a short-circuit protection device and a contactor, it provides a motor starter whose functions are the same as those of a TeSys model U starter-controller and, in particular, provides motor starter overload protection and control functions. The following starter combinations provide Type Coordination to IEC/EN 60947-4- under overcurrent conditions up to 50kA at 400V. This standard provides for continuity of service where only light tack welding of the contactor poles (easily broken) is permitted under short circuit conditions.. Composition A TeSys model U controller consists of a control unit whose adjustment range is compatible with the secondary of current transformers, plus a control base which also allows fitment of a function module or a communication module. It requires a c 4 V external power supply. Combinations providing Type Coordination at 50kA With circuit-breaker Standard power ratings of Circuit-breaker () Contactor Model U controller Current transformers 3-phase motors 50-60 Hz Category AC-3 400/45 V P kw Ie A Reference Rating A Irm () A Reference (3) Reference Reference 8,5 35 NS80H MA50 50 500 LC D40 LUTM + LUCp 3 x LUT C005 4 NS80H MA50 50 650 LC D50 LUTM + LUCp 3 x LUT C005 30 57 NS80H MA80 80 880 LC D65 LUTM + LUCp 3 x LUT C005 37 69 NS80H MA80 80 040 LC D80 LUTM + LUCp 3 x LUT C005 45 8 NS00H MA00 00 300 LC D5 LUTM + LUCp 3 x LUT C005 55 00 NS60H MA50 50 350 LC D5 LUTM + LUCp 3 x LUT C005 75 35 NS60H MA50 50 800 LC D50 LUTM + LUCp 3 x LUT C4005 90 65 NS50H MA0 0 00 LC F85 LUTM + LUCp 3 x LUT C4005 0 00 NS50H MA0 0 640 LC F5 LUTM + LUCp 3 x LUT C4005 3 40 NS400H MA30 30 300 LC F65 LUTM + LUCp 3 x LUT C4005 60 85 NS400H MA30 30 460 LC F330 LUTM + LUCp 3 x LUT C4005 00 35 NS630H MA500 500 5000 LC F400 LUTM + LUCp 3 x LUT C4005 0 388 NS630H MA500 500 5500 LC F400 LUTM + LUCp 3 x LUT C4005 50 437 NS630H MA500 500 6000 LC F500 LUTM + LUCp 3 x LUT C8005 With fuses Standard power ratings of 3-phase motors 50-60 Hz Category AC-3 400/45 V P kw Ie A Switch disconnectorfuse gg fuses GE Power Controls RED SPOT Reference Size Reference A Contactor Model U controller Current transformers Reference (3) Reference Reference 8,5 35 GS GB30 A3 TIS63M80 LC D40 LUTM + LUCp 3 x LUT C00 4 GS GB30 A3 TIS63M80 LC D50 LUTM + LUCp 3 x LUT C00 30 57 GS GB30 A3 TIS63M00 LC D65 LUTM + LUCp 3 x LUT C00 37 69 GS LLB30 A4 TCP00M5 LC D80 LUTM + LUCp 3 x LUT C00 45 8 GS LLB30 A4 TCP00M5 LC D95 LUTM + LUCp 3 x LUT C00 55 00 GS LLB30 A4 TCP00M60 LC D5 LUTM + LUCp 3 x LUT C00 75 35 GS LB30 B TF00M50 LC D50 LUTM + LUCp 3 x LUT C400 90 65 GS MMB30 B TF00M50 LC F85 LUTM + LUCp 3 x LUT C400 0 00 GS MMB30 B TF00M35 LC F5 LUTM + LUCp 3 x LUT C400 3 40 GS NB30 B3 TKF35M355 LC F65 LUTM + LUCp 3 x LUT C400 60 85 GS PPB30 B3 TKF35M355 LC F330 LUTM + LUCp 3 x LUT C400 00 35 GS QQB30 B4 TMF400M450 LC F400 LUTM + LUCp 3 x LUT C400 0 388 GS QQB30 B4 TMF400M450 LC F400 LUTM + LUCp 3 x LUT C400 50 437 GS SB30 C TTM500 LC F500 LUTM + LUCp 3 x LUT C800 35 555 GS SB30 C TTM500 LC F630 LUTM + LUCp 3 x LUT C800 () Product marketed under the Merlin Gerin brand. () Irm : setting current of the magnetic trip (3) For reversing operation, replace the prefix LC with LC. Characteristics : pages 40 and 4 Dimensions : page 5 page 5 4 Schneider Electric

References, dimensions, mounting, schemes TeSys Model U 0 Controllers 53083 References Control bases (control circuit voltage c 4 V) Connection For use Reference Weight Current transformers Control with contactor Screw Screw LC Dpp LUT M0BL r 0.800 Control units Description Class For motor type LC Fppp LUT M0BL r 0.800 Setting range Reference Weight Advanced 0 3-phase 0.35.05 LUCB TBL r 0.40 0 3-phase 0.35.05 LUCD TBL r 0.40 Multifunction 5 to 30 3-phase 0.35.05 LUCM TBL r 0.75 LUT M + LUCM TBL Current transformers Operating current Reference Weight Primary Secondary 30 LUT C030 r 0.00 50 LUT C050 r 0.00 00 LUT C00 r 0.00 00 LUT C00 r 0.00 400 LUT C400 r 0.430 800 LUT C800 r 0.600 Function modules and communication modules The TeSys model U controller is fully compatible with the modules listed below. b Thermal overload alarm module LUF W0, see page. b Motor load indication module LUF V, see page. b Modbus communication module LUL C03, see page 30. Dimensions, mounting Dimensions Mounting 63 73 73 7 0 45 0 30 Ø4 Schemes LUTM LUTM LUTM S S + 4 V Aux. L L L3 I I I3 I4 I5 I6 I7 I8 I9 I0 LUTM 3/NO 3/NO 95 96/NO () 97/NC () 98 05 06/NC () The contacts are represented with controller powered up and not in a fault condition. r Available Qtr 3 004. Characteristics : pages 40 and 4 5

References TeSys Model U 0 Parallel wiring module and pre-wired coil connection components Parallel type connection Architecture 50836 6 7 6 Outputs for starter commands 7 RJ45 connector for connecting to splitter box 4 To PLC 5 3 Parallel wiring module LUF C00 Pre-wired coil connection LU9B NC 3 Connection cable LU9 Rp with one RJ45 connector at each end 4 Splitter box LU9 G0 for 8 motor starters with channel connections on the PLC side by HE 0 connectors and on the starter-controller side by 8 RJ45 connectors. 5 Connection cable TSX CDPppp with one HE 0 connector at each end. Parallel wiring module The parallel wiring system makes it possible to connect starter-controllers to the PLC I/O modules quickly and without any need for tools. It replaces traditional screw terminal and single wire connections. It is used with the Telefast pre-wired system. The parallel wiring module provides the status and command information for each starter-controller. It must be used with a c 4 V control unit, LUCp ppbl. Splitter box LUF GO distributes information from the PLC I/O modules to each of the starter-controllers connected to it. This splitter box is optimised for use with card TSX DMZ8DTK. When used in conjunction with the Advantys STB distributed I/O solution, the model U starter-controller is ideal in decentralised automation architecture (). The use of dedicated parallel interface module STB EPI 45 allows remote connection of 4 starter-controllers. 5380 8 Each of the dedicated module s 4 channels has: b outputs: control of starter forward and reverse running, b 3 inputs: position of the knob, fault indication and position of the poles. 9 0 Connection to the dedicated module is by means of the following cables: b RJ45 LU9Rpp, for lengths less than 3 metres, b 490 NTW 000pp, for lengths greater than 3 metres Description Item Reference Weight Parallel wiring module LUF C00 0.045 () Please consult our "Distributed I/O Advantys STB, the open device integration I/O system" catalogue 8 Dedicated parallel interface module (STB EPI 45) 9 Power base 0 c 4 V control unit (LUC B/D/C/M pp BL) Parallel wiring module (LUF C00) Options: add-on contact blocks, reverser blocks Characteristics : pages 34 and 39 pages 50 to 54 6

References TeSys Model U 0 Parallel wiring module and pre-wired coil connection components 5083 Pre-wired components simplify wiring and reduce wiring errors. Connection of communication module output terminals to the coil terminals By pre-wired connector or wire link. b Pre-wired connector : pre-wired coil connection The use of a power base without pre-wired connections is recommended. Description Pre-wired coil connection For use with power base Item Reference Weight LUB pp LU9B NC 0.045 LUB pp 8 LU9M RC 0.030 LUB + LUF C00 + LU9B NC b Wire link : Allows insertion, for example, of an emergency stop control or a voltage interface. This type of connection must be used for a reversing starter-controller assembled using an LU6M reverser block for separate mounting. When reverser block LU6M and the power base are mounted side-by-side, a pre-wired connector LU9M RC may be used. 5640 Connection of parallel wiring module to the PLC No tools are required to connect the parallel wiring module to the PLC. Connection is via a splitter box which allows up to 8 starter-controllers to be connected; a maximum of 4 reversing starters per splitter box is allowed. The splitter box requires a c 4 V power supply. LUB + LUFC00 + LU9MRC 8 Splitter box Connectors Item Reference Weight PLC side Starter-controller side (6I/O) x HE 0 0-way 8 x RJ45 4 LU9 G0 () 0.60 Connection cables to the splitter box Connectors Item Length m Reference Weight x RJ45 connectors 3 0.3 LU9 R03 0.045 LU9 R0 0.065 3 LU9 R30 0.5 Connection cables from splitter box to PLC Type of connection Gauge C.s.a. Length Reference Weight PLC side Splitter box side AWG mm m HE 0 0-way HE 0 0-way 0.34 0.5 TSX CDP 053 0.085 TSX CDP 03 0.50 TSX CDP 03 0.80 3 TSX CDP 303 0.40 5 TSX CDP 503 0.670 8 0.080 ABF H0 H00 0.080 ABF H0 H00 0.40 3 ABF H0 H300 0.0 Bare wires HE 0 0-way 0.34 3 TSX CDP 30 0.400 5 TSX CDP 50 0.660 () Allows "run" and "fault" status of each starter-controller to be fed back to the PLC and transmits commands. Characteristics : pages 34 and 39 pages 50 to 54 Schneider Electric 7

References TeSys Model U AS-Interface cabling system Series type connection Architecture Communication module ASILUF C5 Tap-off XZ CG04 3 Pre-wired coil connection LU9B NC 3 c 4 V AS-i 538 Information transmitted by the AS-Interface system AS-Interface profile 7.D.F.0 Data bits (command) Bit value = 0 = Command D0 (O) Stop forward Forward running Command D (O) Stop reverse Reverse running Command D (O) Not used Not used Command D3 (O) Not used Not used Data bits (status) Bit value = 0 = Status D0 (I) Not ready or fault Ready Status D (I) Stopped Running Status D (I) Not used Not used Status D3 (I) Not used Not used 5 4 3 Green LED: AS-Interface voltage present Red LED: AS-Interface or module fault 3 Yellow connector for connection to the AS-Interface system 4 Black connector for connection to a c 4 V auxiliary power supply 5 Outputs for starter commands AS-Interface communication module The AS-Interface communication module makes it easy to connect starter-controllers to the AS-Interface cabling system, and therefore allows remote control and command of these starter-controllers. The various operating states of the module (AS-Interface voltage present, communication fault, addressing fault, ) are indicated on the front panel by LEDs (green and red). Operation of the module is continuously monitored by auto-testing, in a way that is totally transparent to the user. The incorporation of AS-Interface V.. functions allows diagnostics to be performed on the module, either remotely via the bus or locally via the ASI TERV addressing terminal. The communication module must be connected to a c 4 V auxiliary power supply and must be used in conjunction with a c 4 V control unit, LUCp ppbl. The product is supplied with a yellow connector 6 for connection to the AS-Interface system, a black connector 7 for connection to the c 4 V auxiliary supply and a black connector 8 for connection of the outputs. Description Item Reference Weight Communication module ASILUF C5 0.065 8

References (continued) TeSys Model U AS-Interface cabling system 50300 Pre-wired components simplify wiring and reduce wiring errors. Connection of communication module output terminals to the coil terminals By pre-wired connector or wire link. b Pre-wired connector: pre-wired coil connection The use of a power base without pre-wired control circuit connections is recommended. 3 Description For use with power base Item Reference Weight Pre-wired coil connection LUB pp 3 LU9B NC 0.045 LUB pp 5 LU9M RC 0.030 50799 LUB + ASILUF C5 + LU9B b Wire link Allows insertion, for example, of an emergency stop control or a voltage interface. This type of connection must be used for a reversing starter-controller assembled using an LU6M reverser block for separate mounting. When reverser block LU6M and the power base are mounted side-by-side, a pre-wired connector LU9M RC may be used. Connection of the communication module on the serial bus () Achieved by using a tap-off for connection to ribbon cables: b for AS-Interface (yellow). b for separate c 4 V supply (black). 5 Description Length m Reference Weight Tap-off XZ CG04 0.65 50898 LUB + ASILUF C5 + LU9M 50899 Consoles and cable adaptors Description Reference Weight Addressing console XZ MC 0.550 Battery operated. Battery charger supplied AS-Interface V. and V.. compatible Adjustment and diagnostics console ASI TERV 0.500 Runs on LR6 batteries Allows addressing of AS-Interface V..interfaces and diagnostics Cable adaptor For console XZ MC XZ MG 0.070 XZ MC ASI TERV Software set-up AS-Interface configuration is carried out using PL7 Micro/Junior/Pro software. From the module declaration screen, it is possible to configure all the slave devices corresponding to all the AS-Interface I/O. Configuration is carried out by following the instructions on the screen. 564 TeSys model U user's manual () Application Language Reference Weight On CD-Rom Multi-language LU9 CD 0.0 (3) () Degree of protection IP 54. Connection by 4 x 0.34 mm wires. Black wire: +4 V. White wire: 0 V. Blue wire: AS-Interface ( ). Brown wire: AS-Interface (+). () The CD-Rom contains user's manuals for the AS-Interface and Modbus communication modules, multifunction control units and gateway modules, as well as the gateway programming software. (3) English, French, German, Italian, Spanish Configuration example with Premium TSX SAY 00/000 module 9

References TeSys Model U 0 Modbus communication module and pre-wired coil connection components Series type connection Architecture b Star topology 4 6 To PLC 3 3 Communication module LUL C03 Pre-wired coil connection LU9B NC 3 Connection cable with one RJ45 connector at each end VW3 A8 306 Rpp 4 Modbus hub LU9 GC3 with channel connections to PLC and to starter-controller with RJ45 connectors 6 Line terminator VW3 A8 306 RC b Bus topology Communication module LUL C03 Pre-wired coil connection LU9B NC 5 T-junction VW3 A8 306 TFpp 6 Line terminator VW3 A8 306 RC 50377 5 5 6 Information carried by the bus Depends on the type of control unit used. Control unit Standard Advanced Multifunction Starter status (ready, running, fault) Alarms (overcurrent,...) Thermal overload alarm Remote reset via the bus Indication of motor load Fault differentiation Remote programming and monitoring of all functions "Log" function "Monitoring" function Start and Stop commands Functions performed For more detailed information, please refer to User's Manual LU9 CD, see page opposite. Module status signalling LED c 4 V supply connection 3 RJ45 connector RS485 for Modbus link 4 digital inputs 5 digital output 6 Outputs for starter commands Modbus communication module Communication module LUL C03 enables the model U starter-controller to be connected to the Modbus network. It must have a c 4 V supply and must be used in conjunction with a c 4 V control unit, LUCp ppbl. It incorporates a 0.5 A, c 4 V digital output for local command requirements and two configurable digital inputs. Description Item Reference Weight Communication module LUL C03 r 0.080 r Available June 004. Characteristics : pages 34 and 39 pages 50 to 54 30

References TeSys Model U 0 Modbus communication module and pre-wired coil connection components 5080 Pre-wired components simplify wiring and reduce wiring errors. Connection of communication module output terminals to the coil terminals By pre-wired connector or wire link. b Pre-wired connector : pre-wired coil connection The use of a power base without pre-wired control circuit connections is recommended. Description For use with power base Item Reference Weight Pre-wired coil connection LUB pp LU9B NC 0.045 LUB pp 7 LU9M RC 0.030 508 LUB + LUL C03 + LU9B b Wire link : Allows insertion, for example, of an emergency stop control or a voltage interface. This type of connection must be used for a reversing starter-controller assembled using an LU6M reverser block for separate mounting. When reverser block LU6M and the power base are mounted side-by-side, a pre-wired connector LU9M RC may be used. Connection of the communication module on the serial bus Achieved either by means of a Modbus hub or using T-junctions. Description Modbus hub 8 slaves Cables fitted with two RJ45 connectors Length m Item Reference Weight 4 LU9 GC3 0.60 0.3 3 VW3 A8 306 R03 0.045 3 VW3 A8 306 R0 0.065 3 3 VW3 A8 306 R30 0.5 7 T-junctions () 0.3 5 VW3 A8 306 TF03 0.03 LUB + LUL C03 + LU9M 5 VW3 A8 306 TF0 0.03 RS 485 line terminator 6 VW3 A8 306 RC 0.0 TeSys model U user's manual () Application Language Reference Weight On CD-Rom Multi-language (3) LU9 CD 0.0 () Fitted with RJ45 female connectors (bus side) and a 0.3 m or m length cable supplied with an RJ45 male connector (station side). () The CD-Rom contains user's manuals for the AS-Interface and Modbus communication modules, multifunction control units and gateway modules, as well as the gateway programming software. (3) English, French, German, Italian, Spanish. Characteristics : pages 34 and 39 pages 50 to 54 Schneider Electric 3

Presentation, description, setting-up 0 TeSys Model U 0 Starters, drives and communication Communication gateways LUF P Presentation Communication gateways LUF P allow connection between Modbus and field buses such as Fipio, Profibus DP or DeviceNet. After configuration, these gateways manage information which can be accessed by the Modbus bus and make this information available for read/write functions (command, monitoring, configuration and adjustment) on the field buses. An LUF P communication gateway consists of a box which can be clipped onto a 35 mm omega rail, allowing connection of up to 8 Slaves connected on the Modbus bus. Example of architecture LUF P Configuration of gateway by PC Model U starter-controllers Fipio Profibus DP DeviceNet () Modbus 565 ATS 48 ATV 8 ATV 38 ATV 58 ATV 58F () Connection kit for PowerSuite software workshop. Description Front panel of the product LED indicating : - communication status of the Modbus buses, - gateway status, - communication status of the Fipio, Profibus DP or DeviceNet bus. Connectors for connection to Fipio, Profibus DP or DeviceNet buses. 565 3 4 5 Underside of product 3 RJ45 connector for connection on the Modbus bus 4 RJ45 connector for link to a PC 5 c 4 V power supply Software set-up For the Fipio bus, software set-up of the gateway is performed using either PL7 Micro/Junior/Pro software or ABC Configurator software. For the Profibus DP and DeviceNet buses, software set-up is performed using ABC Configurator. This software is included: b in the PowerSuite software workshop for PC (see page 3), b in the TeSys model U user's manual. Characteristics, references : page 33 Dimensions : page 33 3 Schneider Electric

Characteristics, references, dimensions 0 TeSys Model U 0 Starters, drives and communication Communication gateways LUF P Characteristics Bus type Fipio Profibus DP DeviceNet Environment Conforming to IEC 664 Degree of pollution : Ambient air temperature Around the device C + 5 + 50 Degree of protection IP 0 Electromagnetic compatibility Emission Conforming to IEC 5008- : 993 Immunity Conforming to IEC 6000-6- : 999 Number of Modbus slaves which can be connected y 8 Connection Modbus By RJ45 connector conforming to Schneider Electric RS485 standard To a PC By RJ45 connector, with PowerSuite connection kit Field bus By SUB D9 female connector By SUB D9 female connector By 5-way removable screw connector Supply V External supply, c 4 ± 0 % Consumption Max. ma 80 Typical ma 00 Indication/diagnostics By LED on front panel Services Profile FED C3 or FED C3P Command 6 configurable words () configurable words 56 configurable words Monitoring 6 configurable words () configurable words 56 configurable words Configuration and adjustment By gateway mini messaging facility (PKW) () If the gateway is configured using PL7 and not ABC Configurator, the I/O capacity is limited to a total of 6 words. References Description For use with With bus type Reference Weight 863 873 Connection accessories TSX FP ACC Communication gateways TeSys Model U starter-controllers, Altistart 48, Altivar 8, 38, 58 and 58F Description For use with Length m Fipio/Modbus LUF P 0.45 Profibus DP/Modbus LUF P7 0.45 DeviceNet/Modbus LUF P9 0.45 Connectors Reference Weight Connection cables Modbus 3 RJ45 type connector and VW3 A8 306 D30 0.50 one end with stripped wires 0.3 RJ45 type connectors VW3 A8 306 R03 0.050 RJ45 type connectors VW3 A8 306 R0 0.050 3 RJ45 type connectors VW3 A8 306 R30 0.50 Connectors Fipio SUB-D 9 male connector TSX FP ACC 0.040 490 NAD 9 03 Documentation Dimensions Profibus mid line Profibus line end SUB-D 9 male connector 490 NAD 9 04 SUB-D 9 male connector 490 NAD 9 03 Description Medium Language Reference Weight User's manual for TeSys model U range () CD-Rom Multilingual : English, French, German, Italian, Spanish LU9 CD 0.0 () This CD-Rom contains user's manuals for AS-Interface and Modbus communication modules, multifunction control units and gateways, as well as for the gateway programming software, ABC Configurator. = 0 = 75 7 Presentation, description : page 3 Setting-up : page 3 Schneider Electric 33

Characteristics TeSys Model U 0 Environment Approvals UL, CSA Pending : BV, GL, LROS, DNV, PTB Conforming to standards Rated insulation voltage (Ui) Conforming to IEC/EN 60947-, overvoltage category III, degree of pollution : 3 Rated impulse withstand voltage (Uimp) Safety separation of circuits SELV Degree of protection Conforming to IEC/EN 60947- (protection against direct finger contact) To UL508, CSA C- n 4 V 600 Conforming to IEC/EN 60947-6- kv 6 Conforming to IEC/EN 60947- appendix N Front panel outside connection zone IEC/EN 60947-6-, CSA C- N 4, Type E UL 508 type E : with phase barrier LU9 SP0 V 690 V Between the control or auxiliary circuit and the main circuit : 400 Between the control and auxiliary circuits : 400 IP 40 Front panel and wired terminals IP 0 Other faces IP 0 Protective treatment Conforming to IEC/EN 60068 TH Conforming to IEC/EN 60068--30 Cycles Conforming to IEC/EN 60068-- h 48 Ambient air temperature around the device Storage C - 40 + 85 Operation C Power bases and standard and advanced control units : - 5 + 70. (At temperatures above 60 C and up to 70 C, for Ie = 3 A, leave a minimum gap 9 mm between products). Power bases and multifunction control units : - 5 + 60. (At temperatures above 45 C, leave a minimum gap of 9 mm between products. At temperatures above 55 C up to 60 C, leave a gap of 0 mm between products.) Maximum operating altitude m 000 Operating positions In relation to normal vertical mounting plane 30 90 90 30 Flame resistance Conforming to UL 94 V Conforming to IEC/EN 60695-- C 960 (parts supporting live components) C 650 Environmental restrictions Shock resistance / sine wave = ms Vibration resistance 5 300 Hz Conforming to IEC/EN60068--7 () Conforming to IEC/EN 60068--6 () Cadmium and silicone-free, recyclable Power poles open : 0 gn Power poles closed : 5 gn Power poles open : gn Power poles closed : 4 gn Immunity to electrostatic discharge Immunity to radiated highfrequency disturbance Immunity to fast transient currents Conforming to IEC/EN 6000-4- kv In open air : 8 - Level 3 kv On contact : 8 - Level 4 Conforming to IEC/EN 6000-4-3 V/m 0 - Level 3 Conforming to IEC/EN 6000-4-4 kv All circuits except for serial link : 4 - Level 4 kv Serial link : - Level 3 Immunity to dissipated shock waves Immunity to conducted highfrequency disturbance Conforming to 60947-6- Common mode Serial mode Uc a 0...40 V kv c0...0 V Uc < 00 V Not applicable: for use on a protected supply Conforming to IEC/EN 6000-4-6 V 0 () Without modifying the contact states, in the most unfavourable direction. References : pages 4 to 7 Dimensions : pages 48 and 49 pages 50 to 54 34 Schneider Electric

Characteristics TeSys Model U 0 Power bases and control units Power base and control unit type Power circuit connection characteristics Connection to Ø 4 mm screw clamp terminals Flexible cable without cable end Flexible cable with cable end Solid cable without cable end Screwdriver LUB + LUCA or LUCB or LUCC or LUCD LUB 3 + LUCA or LUCB or LUCC or LUCD LUB + LUCM LUB 3 + LUCM LUM LU6M conductor mm.5 0.5 0.5 0.5 0.5 0 conductors mm.5 6.5 6.5 6.5 6.5 6 conductor mm 6 6 6 6 6 conductors mm 6 6 6 6 6 conductor mm 0 0 0 0 0 conductors mm 6 6 6 6 6 Philips n or flat screwdriver : Ø 6 mm Tightening torque N.m.9.5.9.5.9.5.9.5.9.5 Control circuit connection characteristics Connection to Ø 3 mm screw clamp terminals Flexible cable without cable end Flexible cable with cable end Solid cable without cable end Screwdriver conductor mm 0.75.5 0.75.5 0.75.5 0.75.5 0.75.5 conductors mm 0.75.5 0.75.5 0.75.5 0.75.5 0.75.5 conductor mm 0.34.5 0.34.5 0.34.5 0.34.5 0.34.5 conductors mm 0.34.5 0.34.5 0.34.5 0.34.5 0.34.5 conductor mm 0.75.5 0.75.5 0.75.5 0.75.5 0.75.5 conductors mm 0.75.5 0.75.5 0.75.5 0.75.5 0.75.5 Philips n or flat screwdriver : Ø 5 mm Tightening torque N.m 0.8. 0.8. 0.8. 0.8. 0.8. Control circuit characteristics Rated voltage of control circuit a 50/60 Hz V 4 40 4 40 c V 4 40 4 40 4 4 Voltage limits c 4 V () V 0 7 0 7 0 8 0 8 Operation a 4 V V 0 6.5 0 6.5 a or c 48 7 V V a 38.5 7, c 38.5 93 a 0 40 V, c 0 0 V V a and c 88 64 a and c 88 64 Drop-out c 4 V V 4.5 4.5 4.5 4.5 a 4 V V 4.5 4.5 a or c 48 7 V V 9 9 a 0 40 V, c 0 0 V V 55 55 Typical consumption c 4 V ma 30 0 50 00 0 I max while closing a 4 V ma 40 0 360 a or c 48 7 V ma 80 80 050 a 0 40 V, c 0 0 V ma 80 80 840 I rms sealed c 4 V ma 55 70 70 75 0 a 4 V ma 70 90 () a or c 48 7 V ma 35 45 () a 0 40 V, c 0 0 V ma 30 0 () Heat dissipation W 3.7.8 Operating time Closing ms 4 V : 70/ 48 V 60; 7 V : 50 75 65 Opening ms 35 35 35 35 Resistance to micro-breaks ms 3 3 3 3 Resistance to voltage drops EC/EN 6000-4- At least 70 % of Uc for 500 ms Mechanical durability In millions of operating cycles 5 5 5 5 Maximum operating rate In operating cycles per hour 3600 3600 3600 3600 Main pole characteristics Number of poles 3 3 3 3 Isolation function To IEC/EN 60947- Possible Yes Yes Yes Yes Padlocking padlock with Ø 7 mm shank Rated thermal current A 3 3 Rated operating current (Ue 440V) To IEC/ EN 60947-6- In cat. AC-4 θ 70 C : A θ 70 C : 3A θ 55 C : A θ 55 C : 3A In cat. AC-43 θ 70 C : A θ 70 C : 3A θ 55 C : A θ 55 C : 3A Rated operating voltage V 690 (3) 690 (3) 690 (3) 690 (3) Frequency limits Of the operating current Hz 40 60 40 60 40 60 40 60 Power dissipated in the power circuits Operating current A 3 6 9 8 5 3 Power dissipated in all three poles W 0. 0.3 0.6..4 4.6 7.5 Rated breaking capacity on short-circuit V 30 440 500 690 ka 50 50 0 4 Total breaking time ms Thermal stress limit With Isc max on 440 V ka s 90 0 90 0 () Voltage with maximum ripple of ± 0 %. () No consumption sealed. (3) For 690 V, use phase barrier LU9 SP0. Schneider Electric 35

Characteristics TeSys Model U 0 Reversing power bases and auxiliary contacts Specific characteristics of power bases LUB and reverser blocks LUM or LU6M Duration of inrush phase a 50/60 Hz ms 5 c ms 5 Maximum operating time Without change of direction ms 75 With change of direction ms 50 General characteristics of auxiliary contacts Conventional rated thermal current (Ith) For ambient temperature θ < 70 C A 5 Frequency of the operating current Hz Up to 400 Minimum switching capacity λ = 0-8 U min V 7 I min ma 5 Short-circuit protection Conforming to IEC/EN 60947-5- A gl fuse : 4 Short-time rating Permissible for s A 30 500 ms A 40 00 ms A 50 Insulation resistance mω 0 Non-overlap time Guaranteed between N/C and N/O contacts ms (on energisation and on de-energisation) Specific characteristics of auxiliary contact built-into the power base Linked contacts Conforming to IEC/EN 60947-4- Each power base has N/O contact and N/C contact which are mechanically linked Mirror contact Conforming to draft standard IEC/EN 60947- The N/C contact fitted in each power base reliably represents the state of the power contacts (safety scheme) Rated operating voltage (Ue) V Up to a 690; c 50 Rated insulation voltage (Ui) Conforming to IEC/EN 60947-5- V 690 Conforming to UL, CSA V 600 Specific characteristics of auxiliary contacts in modules LUF N, of auxiliary contacts LUA and of reverser blocks LUM and LU6M Rated operating voltage (Ue) V Up to a 50; c 50 Rated insulation voltage (Ui) Operational power of contacts Conforming to IEC/EN 60947-5- Conforming to IEC/EN 60947-5- V 50 Conforming to UL, CSA V 50 a.c. supply, categories AC-4 and AC-5 Electrical durability (up to 3600 operating cycles/hour on an inductive load such as the coil of an electromagnet : making power (cos ϕ 0.7) = 0 times the power broken (cos ϕ = 0.4) d.c. supply, category DC-3 Electrical durability (up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. million operating cycles 3 million operating cycles 0 million operating cycles V 4 48 5 30 400 440 600 V 4 48 5 50 VA 60 0 80 560 960 050 440 W 0 90 75 68 VA 6 3 80 60 80 300 40 W 70 50 38 33 VA 4 8 0 40 70 80 00 W 5 8 4 Millions of operating cycles 8 7 6 5 4 3 0,8 0,7 0,6 0,5 0,4 0,3 Millions of operating cycles 8 7 6 5 4 3 0,8 0,7 0,6 0,5 0,4 0,3 50 V 5 V 48 V 4 V 0, 0, 0, 0, 0, 0,3 0,4 0,6 0,8 3 4 6 8 0 0,5 0,7 0,9 5 7 9 Current broken in A 0, 0, 0, 0,3 0,4 0,6 0,8 3 4 6 8 0 0,5 0,7 0,9 5 7 9 Current broken in A References : page 4 Dimensions : pages 48 and 49 pages 50 to 54 36 Schneider Electric

Characteristics TeSys Model U 0 Control units Characteristics of standard control units LUCA Protection Motor type 3-phase Conforming to standard IEC/EN 60947-6-, UL 508, CSA C- n 4 Overload protection Short-circuit protection Tripping class conforming to 0 UL 508, IEC/EN 60947-6- Frequency limits of the operating current Hz 40 60 Temperature compensation C - 5 + 70 Protection against phase imbalance With Tripping threshold 4. x the setting current Tripping tolerance ± 0 % Characteristics of advanced control units LUCB, LUCC and LUCD Control unit type LUCB LUCC LUCD Protection Motor type 3-phase Single-phase 3-phase Overload protection Short-circuit protection Conforming to standard IEC/EN 60947-6-, UL 508, CSA C- n 4 Tripping class conforming to UL 508, IEC/EN 60947-6- IEC/EN 60947-6-, UL 508, CSA C- n 4 0 0 0 IEC/EN 60947-6-, UL 508, CSA C- n 4 Frequency limits of the operating current Hz 40 60 40 60 40 60 Temperature compensation C - 5 + 70-5 + 55-5 + 70 Protection against phase imbalance With With Tripping threshold 4. x the setting current 4. x the setting current 4. x the setting current Tripping tolerance ± 0 % ± 0 % ± 0 % Characteristics of multifunction control units LUCM Protection Motor type Selectable : single-phase or 3-phase Conforming to standard IEC/EN 60947-6-, UL 508 Overload protection Communication interface for terminal on enclosure door Tripping class conforming to 5, 0, 5, 0, 5, 30 (selectable) UL 508, IEC/EN 60947-6- Frequency limits of the operating current Hz 40 60 Temperature compensation C - 5 + 55 Physical interface RS 485 multi-drop Connector RJ45 on front panel Protocol Modbus RTU Maximum transmission speed bit/s 9 00 (self-configuration up to this value) Maximum return time ms 00 Display Type LCD, lines of characters Language version Multilanguage (English, French, German, Italian, Spanish) Accuracy ± 5 % Resolution % of Ir Auxiliary supply External type V c 4, with maximum ripple of ± 0 %. Heat dissipation W 0.8 Configuration table for protection devices and alarms on multifunction control units LUCM Tripping Alarm Adjustment of tripping threshold Adjustment of time before tripping Adjustment of alarm threshold Factory setting Factory setting Range Default value Range Default value Range Default value Overcurrent Activated () 3 7 Ir 4. Overload Activated () Activated 0.5 3 A () Ir min Class : 5 30 5 0 00 % of the thermal state 85 % Earth fault Activated Activated 0. 5 Ir min 0.3 Ir min 0.. s 0. s 0. 5 Ir min 0.3 Ir min Phase imbalance Activated Activated 0 30 % 0 % 0. 0 s 5 s 0 30 % 0 % Torque limitation Deactivated Deactivated 8 Ir Ir 30 s 5 s 8 Ir Ir No-load running Deactivated Deactivated 0.3 Ir 0.5 Ir 00 s 0 s 0.3 Ir 0.5 Ir Long starting times Deactivated Deactivated 8 Ir Ir 00 s 0 s 8 Ir Ir Configuration of additional functions on multifunction control units LUCM Factory setting Setting range Reset Manual Manual, automatic or remote Time before reset 0 s 000 s Type of load 3-phase motor 3-phase motor, single-phase motor Self-cooled Self-cooled, force cooled Language English English, French, German, Italian, Spanish Display Average current Average current, thermal state of motor, current in phase / / 3, earth leakage current, phase imbalance, cause of last 5 faults () This function cannot be deactivated. () The setting range depends on the rating of the control unit used. References : pages 9 to Dimensions : pages 48 and 49 pages 50 to 54 Schneider Electric 37

Characteristics TeSys Model U 0 Limiter-disconnectors and current limiters Characteristics of limiter-disconnector LUA LB Rated insulation voltage (Ui) V 690 conforming to standard IEC/EN 60947- Conventional rated thermal current (Ith) A 3 conforming to standard IEC/EN 60947- Operating threshold I rms ka 50 Breaking capacity V 440 690 ka 30 70 Mounting Directly on the upstream terminals of the starter-controller Connection Solid cable conductor mm.5 0 conductors mm.5...6 Flexible cable without cable end conductor mm 0 conductors mm 6 Flexible cable with cable end conductor mm...6 conductors mm...6 Screwdriver Phillips n or flat screwdriver ø 6 mm Tightening torque N.m.9.5 Characteristics of current limiter LA9 LB90 Rated insulation voltage (Ui) V 690 conforming to standard IEC/EN 60947- Conventional rated thermal current (Ith) A 63 conforming to standard IEC/EN 60947- Operating threshold I rms A 000 Breaking capacity V 440 690 ka 00 35 Mounting Separate Connection Solid cable conductor mm.5 5 conductors mm.5...0 Flexible cable without cable end conductor mm.5 5 conductors mm.5 0 Flexible cable with cable end conductor mm.5 6 conductors mm.5 4 Screwdriver Phillips n or flat screwdriver ø 6 mm Tightening torque N.m. Characteristics of current limiter GV L3 Rated insulation voltage (Ui) V 690 conforming to standard IEC/EN 60947- Conventional rated thermal current (Ith) A 63 conforming to standard IEC/EN 60947- Operating threshold I rms A 500 Breaking capacity V 440 690 ka 70 5 Mounting Directly on the upstream terminals of the starter-controller or separate, using terminal block GV G05 Connection Solid cable conductor mm.5 5 conductors mm.5...0 Flexible cable without cable end conductor mm.5 5 conductors mm.5 0 Flexible cable with cable end conductor mm.5 6 conductors mm.5 4 Screwdriver Phillips n or flat screwdriver ø 6 mm Tightening torque N.m. Characteristics of thermal overload alarm function modules LUF W0 Activation threshold Fixed at 88% of the thermal tripping state Hysteresis between activation and switching off 5 % Display By LED on front panel Supply Powered by the control unit Digital output characteristics Type N/O contact AC-5 30 V max; 400 VA 00 000 operating cycles DC-3 4 V; 50 W 00 000 operating cycles References : pages 7 and Dimensions : pages 48 and 49 pages 50 to 54 38 Schneider Electric