Raritan PXE. Quick Setup Guide. Safety Precautions. Before You Begin. Mounting the PXE. Unpacking the PXE. Zero U Size. 1U Size

Similar documents
QUICK SETUP GUIDE. Raritan PXE. Safety Precautions. Before You Begin. Mounting the PDU. Unpacking the PXE. 1U Size

Raritan PX3TS. Quick Setup Guide. Safety Precautions. Mounting the PX3TS. What's Included

Note: All of PXC data is available on the PX3 support page. Simply visit Support page > Choose a Product > select "PX3." QS Rule.

QUICK SETUP GUIDE. Raritan PX3 and PX2. Safety Precautions. Before You Begin. Unpacking the PX2/PX3. Zero U Size. 1U and 2U Size

Raritan PX. Quick Setup Guide. Safety Precautions. Before You Begin. Unpacking the PX. Mounting the PX. Zero U Size.

EMX. Quick Setup Guide. Package Contents

Branch Circuit Monitor

QUICK SETUP GUIDE. Raritan PX3TS. Safety Precautions. Front View. What's Included

Safety Precautions Legrand PDU. 0U PDU Overview. Outlets. Circuits. Controller with Connector Ports: See Controller (on page 4).

Raritan PXE User Guide

PX-1000/2000 Series. User Guide Release 2.3. Copyright 2012 Raritan, Inc. DPX D-v2.3-E March

QUICK SETUP GUIDE. Raritan PX3TS. Safety Precautions. Front View. What's Included

PX-1000 Series User Guide Release 2.0.5

Raritan EMX User Guide Release 2.1.0

QUICK SETUP GUIDE EMX. Package Contents. Before You Begin. Mounting a Zero U EMX

USB-Cascading Solution

For details on using the LX, access online help from the application, or download help in PDF format from the Support page on Raritan's website.

Dominion KX II. Quick Setup Guide. Package Contents. Forward Mount. Amount included. Item

Cascading Guide. Release Copyright 2019 Raritan, Inc. USBcascade-1F-v3.5.0-E January RoHS

Dominion KX II-101-V2

Dominion KX III User Station

HPE Intelligent Power Distribution Unit Installation Instructions

Dominion KX II. Quick Setup Guide. Package Contents. Forward Mount. Rear Mount

Dominion KX III User Station

Installing and Managing the Switch

Unified Office Gateway UMG Quick Installation Guide. Version: 1.0

Dominion KSX II. Quick Setup Guide. Package Contents. Item. Amount included. Resolutions

Dominion KX II-101. Quick Setup Guide. Step 1: Configure the Target Server

Dominion KSX II. Quick Setup Guide. Step 1: Configure the KVM Target Servers

Manager Appliance Quick Start Guide

TIME SERVER NETSILON. Quick start.

Deploy the ExtraHop Discover Appliance 1100

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Deploy the ExtraHop Trace 6150 Appliance

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide

User Manual. Per Port Monitoring Models

G5 PDU Installation Guide

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS / XGS Quick Installation Guide

Installing the Cisco Unified Videoconferencing 3545 MCU

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Juniper Secure Analytics Quick Start Guide

SecureSync. QuickStart Guide. Time and Frequency Synchronization System OPTION MODULE CARDS

Initial Configuration for the Switch

Installing the Cisco SFS 3504 Server Switch

24-Port Gigabit + 4-Port 10G SFP+ Slot. Layer 3 Stackable Managed Switch XGS Quick Installation Guide

Deploy the ExtraHop Trace 6150 Appliance

LX-1000 Quick Start Instructions E

McAfee Network Security Platform

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

QUICK SETUP GUIDE. MasterConsole Digital. Package Contents. MCD Structure Diagrams

IBM Systems. Quick start guide for IBM System p5 505 ( )

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide

Raritan AMS Series Intelligent Electronic Asset Management

Quick Start Guide (VB1xx/VB2xx/VB3xx) Version 5.3 Form 8041C June 2017

Deploy the ExtraHop Explore 5100 Appliance

Deploy the ExtraHop Discover 3100, 6100, 8100, or 9100 Appliances

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

LifeSize ClearSea Installation Guide August 2012

Switched Rack Power Distribution Unit

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

AlterPath KVM/net Quick Installation Guide

Codian IP VCR IP VCR 2200 Series

Cascade Sensor Installation Guide. Version 8.2 March 2009

Power Xpert Meter 2000 Gateway Card Kit

Quick start guide for p5 520 ( )

CHASSIS-1. Form number 7660

RMX 4000 Installation & Configuration Guide

Startup Guide. for Local Managers. Version 5.1 January

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

Cat5 Reach DVI HD User Guide

dctrack Quick Setup Guide Virtual Machine Requirements Requirements Requirements Preparing to Install dctrack

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Deploy a Customer Site

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

NetBotz 320 Quick Start

McAfee Network Security Platform

HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A)

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Thank you for your purchase of the KX II, the industry's most full-featured, enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.

L2+ Managed PoE Switch GS-5220 PoE Series

24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch

Setting Up Your Cisco Unified Videoconferencing 3500 Gateway

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

Deploy the ExtraHop Discover 3100, 6100, 8100, or 9100 Appliances

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Configuring the Switch

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

Transcription:

Raritan PXE Quick Setup Guide Thank you for purchasing the Raritan PXE intelligent power distribution unit (PDU). The intended use of the PXE is distribution of power to information technology equipment such as computers and communication equipment where such equipment is typically mounted in an equipment rack located in an information technology equipment room. This Quick Setup Guide explains how to install and configure the PXE. For details on using the PXE, access online help from the application, or from the Support page (http://www.raritan.com/support/) on Raritan's website. For more detailed information on this release, see the latest release notes on the Support page. Safety Precautions WARNING! Read and understand all sections in this guide before installing or operating this product. Failure to heed any of the following WARNINGS may result in electric shock, fire, personal injury and death. Prior to operating this product, the user should read the online help and specifically the warnings in the online help. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate. WARNING! Connect this product to an AC power source that is current limited by a suitably rated fuse or circuit breaker in accordance with national and local electrical codes. WARNING! Use this product in a dry location. WARNING! Connect this product to a protective earth ground. Never use a "ground lift adaptor" between the product's plug and the wall receptacle. WARNING! If this product is a model that requires assembly of its line cord or plug, all such assembly must be performed by a licensed electrician and the line cord or plugs used must be suitably rated based on the product's nameplate ratings and national and local electrical codes. Unpacking the PXE The PXE comes in Zero U and 1U sizes. The following describes the equipment shipped with each size. Unpack the components. If any pieces are missing or damaged, report this to Raritan Technical Support at tech@raritan.com, or contact the Raritan partner where you purchased the product. Zero U Size The PXE device Mounting screws, brackets and/or buttons Cable retention clips for outlets (optional) 1U Size The PXE device Mounting screws, brackets and/or buttons Before You Begin 1. Prepare the installation site. Make sure the installation area is clean and not exposed to extreme temperatures or humidity. Allow sufficient space around the device for cabling and outlet connections. Safety instructions are provided in the PXE Online Help. 2. Fill out the Equipment Setup Worksheet found in the PXE Online Help. Record the model, serial number, and use of each IT device connected to the PDU's power outlets. Mounting the PXE Use one of the mounting methods to install your PXE device as appropriate. Circuit Breaker Orientation Limitation Usually a PDU can be mounted in any orientation. However, when mounting a PDU with circuit breakers, you must obey these rules: Raritan PXE Quick Setup Guide 1

Circuit breakers CANNOT face down. For example, do not horizontally mount a Zero U PDU with circuit breakers on the ceiling. If a rack is subject to shock in environments such as boats or airplanes, the PDU CANNOT be mounted upside down. If installed upside down, shock stress reduces the trip point by 10%. Note: If normally the line cord is down, upside down means the line cord is up. Mount the device by screwing a mounting button in the back center of each L-bracket and then having both buttons engage the mounting holes in the rack. The recommended torque for the button is 1.96 N m (20 kgf cm). Mounting 1U Models Using L-Brackets and Buttons This section describes how to mount a 1U PXE device using L-brackets and two buttons. Mounting Zero U Models Using Buttons 1. Turn to the rear of the PDU. 2. Locate the two screw holes on the rear panel. 3. Screw a button in each screw hole. The recommended torque for the button is 1.96 N m (20 kgf cm). To mount 1U models using L-brackets and two buttons: 1. Align the two edge slots of the L-bracket with the two screw holes on the top of the PXE device. 2. Screw the L-bracket to the device and ensure the bracket is fastened securely. 4. Press the PXE device forward, pushing the mounting buttons through the mounting holes, then letting the device drop slightly. Mounting Zero U Models Using L-Brackets and Buttons 1. Fasten the L-bracket to each end of the PXE device. 3. Repeat Steps 1 to 2 to screw another L-bracket to the bottom of the device. 4. After both L-brackets are installed on the device, you can choose either of the following ways to mount the device in the rack. Using rack screws, fasten the device to the rack through two identical holes near the edge of each L-bracket. 2. Choose either of the following ways to fasten the PDU to the rack. Attach the rack screws to the two rackmount holes of each L-bracket. Screw a mounting button in the back center of each L-bracket and then have both buttons engage the mounting holes in the rack. The recommended torque for the button is 1.96 N m (20 kgf cm). Raritan PXE Quick Setup Guide 2

There are two ways to install this driver: automatic and manual installation. Automatic driver installation is highly recommended. Automatic driver installation in Windows : Connecting the PXE to a Power Source The distance between a PDU and its power source must be SHORTER than the PDU's line cord to avoid stretching out the cord. A locking connector used at the power source is highly recommended for a secure connection. To connect a PDU to the power source: 1. Verify that all circuit breakers on the PXE device are set to ON. If not, turn them ON. Or make sure that all fuses are inserted and seated properly. If there are any fuse covers, ensure that they are closed. Note: Not all PXE devices have overcurrent protection mechanisms. 2. Connect each PXE to an appropriately rated branch circuit. See the label or nameplate affixed to your PXE for appropriate input ratings or range of ratings. 3. When a PXE device powers up, it proceeds with the power-on self test and software loading for a few moments. 4. When the software has completed loading, the LED display illuminates and shows numeric digits. Connecting the PXE to Your Network To use the web interface to administer the PXE, you must connect the PXE to your local area network (LAN). To make a wired connection: 1. Connect a standard network cable to the ETHERNET port on the PXE. 2. Connect the other end of the cable to your LAN. Installing the USB-to-Serial Driver The PXE can emulate a USB-to-serial converter over a USB connection. A USB-to-serial driver named "Dominion PX2 Serial Console" is required for Microsoft Windows operating systems. Download the USB Serial Setup 2.0 driver file, which contains dominion-serial.inf, dominion-serial.cat and dominion-serial-setup.exe files, from Raritan website's PX2 Support Files page (https://www.raritan.com/support/product/px2/px2-suppor t-files). 1. Make sure the PXE is NOT connected to the computer via a USB cable. 2. Run dominion-serial-setup-2.0.exe on the computer and follow online instructions to install the driver. Note: If any Windows security warning appears, accept it to continue the installation. 3. Connect the PXE to the computer via a USB cable. The driver is automatically installed. Note: Manually install the driver only if the automatic installation fails. See the section titled "Installing the USB-to-Serial Driver (Optional)" in the online help for manual installation procedure. In Linux: No additional drivers are required, but you must provide the name of the tty device, which can be found in the output of the "dmesg" after connecting the PXE to the computer. Usually the tty device is "/dev/ttyacm#" or "/dev/ttyusb#," where # is an integer number. For example, if you are using the kermit terminal program, and the tty device is "/dev/ttyacm0," perform the following commands: > set line /dev/ttyacm0 > connect Connecting the PXE to a Computer Now establish a USB connection between the PXE and a computer for initial configuration. To make a USB connection: 1. A USB-to-serial driver is required in Windows. Install this driver before connecting the USB cable. See Installing the USB-to-Serial Driver (Optional) (see "Installing the USB-to-Serial Driver" on page 3). 2. Connect a USB cable between the PXE device's USB-B port and your computer's USB-A port. Initial Network Configuration Depending on your networking environment, the best method to initially configure your PXE differs. For a DHCP IPv4 networking environment, see Using a Web Browser (on page 4). Raritan PXE Quick Setup Guide 3

For an IPv6 or static IPv4 networking environment, see Using the CLI. You can also use the CLI to configure the PXE while in the DHCP IPv4 networking environment if you prefer the CLI. Using a Web Browser Initial configuration using a web browser involves these two steps. Step 1: Retrieving the IP Address (on page 4) Step 2: Accessing the PXE Web Interface (on page 4) Step 1: Retrieving the IP Address Once installed in a DHCP IPv4 network, an IP address is automatically assigned to your PXE. The IP address is available via the command line interface (CLI). To retrieve the IP address: 1. Connect the PXE to a computer via a USB cable. See Connecting the PXE to a Computer (on page 3). 2. On the computer, open a communications program with appropriate COM port settings. See Using the CLI for COM port settings. 3. Press Enter in the communications program, and the IP address is displayed. Note: The DHCP-assigned IP address can be also retrieved through the MAC address. You can contact your LAN administrator for assistance. See MAC Address (on page 6). Step 2: Accessing the PXE Web Interface The PXE supports common web browsers, including Microsoft Internet Explorer and Mozilla Firefox. To access the PXE web interface: 1. Open a web browser. 2. Type the IP address of your PXE in the address bar. Using the CLI Make sure the USB cable remains connected between the computer and PXE. To configure the PXE via CLI: 1. On the computer connected to the PXE, open a communications program such as HyperTerminal or PuTTY. 2. Select the appropriate COM port, and set the following port settings: Bits per second = 115200 (115.2Kbps) Data bits = 8 Stop bits = 1 Parity = None Flow control = None Tip: For a USB connection, you can determine the COM port by choosing Control Panel > System > Hardware > Device Manager, and locating the "Serial Console" under the Ports group. 3. In the communications program, press Enter to send a carriage return to the PXE. 4. The PXE prompts you to log in. Both user name and password are case sensitive. a. At the Username prompt, type admin and press Enter. b. At the Password prompt, type raritan and press Enter. 5. When prompted to change the default password, follow onscreen instructions to type your new password. 6. The # prompt appears. 7. Type config and press Enter. 8. To configure network settings, type appropriate commands, and press Enter. All commands are case sensitive. a. The default networking mode is the "wired" mode. Do not change this mode. b. Configure the LAN interface settings. In most scenarios, the default setting (auto) works well and should not be changed unless required. 3. Accept any security warnings that may appear. 4. When the PXE prompts you to log in, type the default user credentials. Both user name and password are case sensitive. User name: admin Password: raritan 5. Change the default password when prompted. 6. To change network settings, choose Device Settings > Network. See online help for detailed information. LAN interface speed LAN interface duplex mode network interface LANInterfaceSpeed <option> <option> = auto, 10Mbps, or 100Mbps. network interface LANInterfaceDuplexMode <mode> <mode> = half, full or auto. Raritan PXE Quick Setup Guide 4

Tip: You can combine multiple commands to configure multiple parameters at a time. For example, network interface LANInterfaceSpeed <option> LANInterfaceDuplexMode <mode> c. To determine which IP protocol (IPv4 or IPv6) is enabled and which IP address (IPv4 or IPv6) returned by the DNS server is used, configure the following parameters. where <option> is enable or disable. See the table below for the commands for manually specifying DNS servers. For the static IP configuration, configure these parameters. IP protocol IP address returned by the DNS server network ip proto <protocol> <protocol> = v4only, v6only or both network ip dnsresolverpreference <resolver> <resolver> = preferv4 or preferv6 Static IPv4 or IPv6 address IPv4 subnet mask IPv4 or IPv6 gateway network <version> ipaddress <ip address> <ip address> = static IP address network ipv4 subnetmask <netmask> <netmask> = subnet mask network <version> gateway <ip address> d. After enabling the IPv4 or IPv6 protocol in the earlier step, configure the IPv4 or IPv6 network parameters. IPv4 configuration method IPv6 configuration method network ipv4 ipconfigurationmode <mode> <mode> = dhcp (default) or static network ipv6 ipconfigurationmode <mode> <mode> = automatic (default) or static Configure the preferred host name for the IPv4 DHCP or IPv6 automatic configuration. Note: The <version> variable in all of the following commands is either ipv4 or ipv6, depending on the type of the IP protocol you have enabled. Preferred host name (optional) network <version> preferredhostname <name> <name> = preferred host name Tip: To override the DHCP-assigned DNS servers with those you specify manually, type this command: network <version> overridedns <option> IPv4 or IPv6 primary DNS server IPv4 or IPv6 secondary DNS server (optional) <ip address> = gateway's IP address network <version> primarydnsserver <ip address> <ip address> = IP address of the primary DNS server network <version> secondarydnsserver <ip address> <ip address> = IP address of the secondary DNS server 9. To quit the configuration mode, type either of the following commands, and press Enter. Command apply cancel Description Save all configuration changes and exit. Abort all configuration changes and exit. The # prompt appears, indicating that you have quit the configuration mode. 10. To verify whether all settings are correct, type the following commands one by one. Command show network show network ip all Description Show network parameters. Show all IP configuration parameters. If all are correct, type exit to log out of the PXE. If any are incorrect, repeat Steps 7 to 10 to change network settings. Raritan PXE Quick Setup Guide 5

What To Do Next 1. Connect IT equipment to the outlet(s) on the PXE. 2. Use a web browser to access the PXE. See Step 2: Accessing the PXE Web Interface (on page 4). 3. Choose Device Settings > Date/Time to configure the PXE with the proper date and time or synchronize it with an NTP server. The PXE device's time must be in sync with the LDAP server to use LDAP authentication. Note: If you are using Raritan's Power IQ to manage the PXE, you must configure Power IQ and the PXE to have the same date/time or NTP settings. 4. Use the menu at the top to create user profiles, set privileges, and set security. Note: Detailed instructions are available in the PXE Online Help. MAC Address A label is affixed to the PXE, showing both the serial number and MAC address. If necessary, you can find its IP address through the MAC address by using commonly-used network tools. Contact your LAN administrator for assistance. Additional Information For more information about the PXE and the entire Raritan product line, see Raritan's website (www.raritan.com). For technical issues, contact Raritan Technical Support. See the Contact Support page in the Support section on Raritan's website for technical support contact information worldwide. Raritan's products use code licensed under the GPL and LGPL. You can request a copy of the open source code. For details, see the Open Source Software Statement at (http://www.raritan.com/about/legal-statements/open-source-software-statement /) on Raritan's website. Raritan PXE Quick Setup Guide 6