A Guide to Management of Change -

Similar documents
RoHS. pressure and temperature transmitter-switch

TPE 1464 Series Pressure Transducer

Differential Liquid/Gas Pressure Transmitter

Explosion-Proof Gauge Pressure Transmitter

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Level-Lance Model 5400A

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

APPLICATION GUIDE. Interface Modules IM Series.

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

INSTALLATION INSTRUCTIONS

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

SCADAPack Modbus multivariable transmitter

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

JT400 Multivariable Transmitter

FLOW MONITOR & TRANSMITTER

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

EMS467 Monitoring System. Installation and Operations Manual Section 40

Family of Water Cut Analyzers

Temperature Switches

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

WIRELESS REMOTE ASSET MONITORING & CONTROL

Vibration Switches. For 24/7 Protection of Cooling Towers, Fin Fans, HVAC Systems, Blowers, Motors and Other Critical Machinery

RoHS. One Series safety Transmitter pressure and temperature transmitter-switch

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

One Series Electronic Pressure and Temperature Switches

SECTION THERMAL UTILITY METERING INTERFACE

Self-Powered Wireless Instrumentation

Wieland Hazardous Location Devices. Protect Your Class I, Division 2/Zone 2 Locations...And Your Budget

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

LAUREL ELECTRONICS, INC.

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Type i2p-100 Electro-Pneumatic Transducer

Installation and Wiring

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

HART Density Gauge Datasheet

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

One Series Explosion Proof Electronic Pressure and Temperature Switches

Datasheet - BNS ZG-ST

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

Chameleon Stand-alone

Jockey Pump Controllers

ONE SERIES Electronic Pressure and Temperature Switches. with "I AM WORKING" Signal

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Slim Industrial Relay Type RSLM Electromechanical

Jockey Pump Controllers

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

SCADAPack Modbus multivariable transmitter

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Electronic Vibration Switch PMC/BETA 440 & 450

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Flow Computer. FloWEB

CDD4 Duct Carbon Dioxide Transmitter

Rosemount 0085 Pipe Clamp Sensor

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

METER REGISTER & DATA CONTROLLER

MAXIMA + Series ROTARY LEVEL CONTROL

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Druck DPI 620 advanced modular calibrator

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet December 2014 IP207, Rev DA

Industrial Safety Systems

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

Digital Indicator Solutions

SensoTrans DMS A 20220

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Conductivity Transmitters

CDD Carbon Dioxide Transmitter

L&J engineering s Wireless Systems. Wireless Level Gauging. company

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB

Capacitance level switches LS 210 LS 220

MTL8000-2/x Series Modular I/O

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

4110 HART Level Encoder

Series DiTemp Series SolarTemp. Digital Thermometers

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Basic Temperature and Limit Controllers

FLS M9.06. ph/orp MONITOR

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

Push-Pull and E-Stop Switches. Datasheet

CDD4 Series Room CO2 Transmitter Installation Instructions

Electromechanical pressure switches

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Fisher i2p-100 Electro-Pneumatic Transducer

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Laurel Electronics Customer Price List

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

Transcription:

A Guide to Management of Change - Replacing United Electric Controls (UE) 120 Series Electromechanical Switch with the UE One Series 1XSW Digital Electronic Switch ViewPoint This guide provides information on replacing a UE electromechanical switch with the digital displaying, programmable and self-diagnostic UE One Series electronic switch. Included are some of the challenges associated with Management of Change (MoC), frequently asked questions, a technology comparison and dimensional drawings the information required to facilitate this easy and cost-effective field instrument upgrade. Keywords: Process Safety Management, Switch, Electromechanical, One Series, Digital Electronic Switch, Instrumentation, Rifinery, Oil & Gas, Power, Safety, Emergency shutdown, Mechanical, Management of Change, MoC y Rick Frauton - Sr. Product Manager

Summary This guide provides information on replacing a UE electro-mechanical switch with the digital displaying, programmable and self-diagnostic UE One Series electronic switch. Included are some of the challenges associated with Management of Change (MoC), frequently asked questions, a technology comparison and dimensional drawings the information required to facilitate this easy and cost-effective field instrument upgrade. UE 120 Series UE One Series 1XSW Shown with Gage Pressure Sensor Management of Change Management of Change (MoC) procedures were born out of the need to document design changes to process control and monitoring equipment. When a field instrument requires replacement, for example, an effort is made to utilize the same instrument type and model, otherwise known as replacing with like kind. This minimizes the effect that the replacement instrument has on the process and maintains the same level of safety. Like kind replacements are not always possible due to instrument availability and design changes, process changes and a desire to improve the safety level and technology. The amount of reporting and documentation needed to satisfy MoC requirements make process monitoring improvements difficult to approve and implement. Exacerbating this issue is the practice of replacing a failed instrument with the same make and model, only to have the replacement instrument eventually fail in exactly the same manner, usually due to misapplication. An alternative instrument upgrade may be desired to increase performance and solve failure issues, but the documentation requirements for MoC may cause upgrade projects to be abandoned, preventing improvements and stifling innovation. What if there was an alternative to a mechanical switch that utilizes the same control scheme and 2-wire connection to the plant control system and provides the same mounting, conduit, wiring and process connections? What if this digital electronic switch had powerful self diagnostics, infinitely adjustable set point and deadband, digital process display and required no power wiring? The Solution The United Electric Controls One Series 1XSW electronic switch drops in place of any mechanical pressure or temperature switch that is connected to the plant control system, PLC or DCS, including 24 VDC, 48 VDC, 120 VAC, 125 VDC and 230 VAC inputs. The One Series 1XSW uses the existing plant wiring from the mechanical switch it is replacing. No additional wiring or power is necessary. No batteries or solar panels are needed. No changes are required for the plant control scheme. 1. Remove the old mechanical switch. 2. Connect the same two wires to the One Series 1XSW electronic switch. 3. Secure the enclosure and connection to the process. Upgrade complete!

Frequently Asked Questions 1 2 3 4 5 6 7 8 9 10 11 Q: What mounting changes are required to replace a 120 Series with a One Series 1XSW? A: None the One Series 1XSW uses the same 4-bolt mounting configuration. Q: What changes will need to be made to electrical conduit connections? A: None The One Series 1XSW uses the same conduit entrance sizes and locations as the 120 Series. Q: What process piping changes will be required? A: ecause of the wide variety of 120 Series sensors, this must be evaluated on a case-by-case basis. See the drawings below for specific dimensions of the One Series 1XSW mounting configurations. Q: What electrical wiring changes will need to be made? A: None, if the 120 Series switch is an input to a DCS, PLC or other controller. The existing two wires can be connected directly to the One Series 1XSW. If, however, the 120 Series is switching a load directly, contact UE Inside Sales to determine if any wiring changes are required. Q: Is the One Series 1XSW considered a dry contact switch? A: No. The One Series 1XSW electronic switch circuit will draw a slight amount of current (~0.7 ma) to power itself, far below the detection threshold of the input card. Q: What changes will be required to my DCS or PLC input card? A: No changes are required. The control system cannot distinguish between the One Series and a dry contact switch. Q: What programming changes will be required in my DCS or PLC? A: None. The One Series 1XSW can utilize the existing control scheme and can be set to be either NO or NC, equivalent to the electro-mechanical switch action of the 120 Series. Q: Will the One Series 1XSW only work with control system inputs? A: No. The electronic switch can also be wired in series with the coil of an interposing relay. Q: Are the enclosure ratings the same between the 120 Series and the One Series 1XSW? A: Yes, the One Series 1XSW can be used in the same area classifications as the 120 Series. Q: Will the One Series 1XSW have the same set point repeatability and deadband as the 120 Series? A: The One Series 1XSW has much tighter repeatability (0.1%) and the deadband can be adjusted 0 100% of sensor s range, providing increased flexibility for new applications. Q: How does the One Series 1XSW price compare to a typical process transmitter? A: Considering the installed cost (wiring, programming, analog input card), the One Series 1XSW is less than 50% of the installed cost of a typical process transmitter. The cost of the upgrade is the cost of the One Series!

Dimensional Drawings PIPE MOUNTING CLAMPS MOUNTING SCREW [220.98 mm] 8.7" (4 PL) A C A C 2" PIPE (USER SUPPLIED) USE 11/32 WIDE SLOTS (4 PL) FOR PIPE MOUNTING OR WALL MOUNTING 1/8 NPT reather vent 1/2 NPT Pressure Connection [135.62 mm] 5.3" [58.42 mm] 2.3" The One Series shown with Dual Seal option M041 and a gauge pressure sensor ENCLOSURE Wall or Pipe Mounting racket Option M449 Temperature Sensors 100 Ω Platinum RTD Pressure Sensors Piezo-resistive strain gage thermowell Adapter option W081 0.250 REF SENSOR THERMOWELL ADAPTER 0.375 REF 2.50 REF 1.06 [26.9mm] 1/2-14 NPT (FEMALE) L TL1-TL3 Sensors 4.50 Gauge pressure sensor 2.50 [63.5mm] Remote sensors L 2.00 [50.8mm] 4.50 1.06 [26.9mm] 0.25 [6.35mm] SPRING LOAD Ø0.125 [3.2mm] L NUN 4.50 0.50 [12.7mm] TTC Sensors 0.50 [12.7mm] 3.0 [76.2mm] 1/4-18 NPT (MALE) OTH ENDS Differential pressure sensor L=60 max., NUN=4 to 10 in 1 increments

Final Analysis Management of Change procedures often discourages substitutions of existing field instruments due to the documentation necessary to choose alternative technologies. Choosing devices that operate and mount in the same manner but offer many new features and uses the existing plant wiring and control scheme may satisfy replace with like kind requirements. Gage Pressure When replacing an electro-mechanical pressure or temperature switch that is connected to the plant control system, United Electric Controls offers the One Series 1XSW electronic switch. This device obtains power from the control system input that it is connected to while providing a solid-state on/off discrete switch signal, the same as expected from a mechanical dry-contact switch. The One Series incorporates a programmable set point and deadband, digital process display and smart IAWTM self diagnostics in an explosion proof and weather tight enclosure. These features provide a quick, easy and cost-effective upgrade path from mechanical switches. Contact UE Differential Pressure For additional information: Visit www.ueonline.com Call +1 (617) 923-6977 Email UE at TechSupport@ueonline.com Thermowell Temperature