Expansion Port RS485/RS422

Similar documents
Expansion Port RS485/RS422 USER MANUAL

/ Expansion port MBUSD OBSAH USERS GUIDE

Expansion port ETH USER S GUIDE

Expansion Port RS232 USER MANUAL

Expansion Port SWITCH USER MANUAL

Expansion Port CNT USER MANUAL

Expansion port WIFI OBSAH. USER S GUIDE

User module. PPP Gateway APPLICATION NOTE

Industrial router XR5i USER S MANUAL

Industrial router XR5i USER S MANUAL.

wienet Router v2 Expansion ports User guide Dok.-Nr. BA Stand: 01/2014 (Rev. A) 2014 Wieland Electric GmbH

EDGE router ER75i. Content of package : Modem ER75i Power supply Antenna Crossover UTP cable Installation CD with instruction and drivers

User module RIP APPLICATION NOTE

SmartSwarm 351 Quick Start Guide

Radio data modem CDX 800 USER S GUIDE.

User module OSPF APPLICATION NOTE

Radio data modem USER S GUIDE CDX 800

User module. Modem Bonding APPLICATION NOTE

User Module. DF1 Ethernet APPLICATION NOTE

Danger important notice, which may have an influence on the user s safety or the function of the device.

User Module ALPHA-MODBUS. Application Note

Danger important notice, which may have an influence on the user s safety or the function of the device.

RGB Power Batten. User Manual. Order code: EQLED032

ER75i v2. EDGE router. and ER75i v2 SL USER S GUIDE

User Module. Modbus TCP2RTU. Application note

CS2 DMX Distribution Splitter

CDP 405 Digital Dimmer Pack

Crossfire. User Manual. Order code: EQLED061

UV Power Flood. User Manual. Order code: EQLED029

ER 75i DUO, ER 75i SL

EDGE router ER75i v2 and ER75i v2 SL USER S GUIDE

PF LED Profile. User Manual

Blitzer Strobe. User Manual. Order code: EQLED366

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ZF LED Zoom Fresnel. User Manual

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

CDMA/UMTS router UCR11 v2 and UCR11 v2 SL USER S GUIDE

Blitzer RGB Strobe. User Manual. Order code: EQLED365

EDGE router ER 75i, ER 75i DUO and ER 75i SL USER S GUIDE

GPRS modem CGU 04i USER S GUIDE

UMTS router UR5 and UR5 USER S GUIDE

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Gobo Projector XP 80W

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

Microbar COB System. User Manual. Order code: EQLED137

LR77 v2. LTE router. and LR77 v2 SL USER S GUIDE

Hardware Manual RM CANview

SmartSwarm 341 Quick Start Guide

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

Vector Beam White. User Manual. Order code: LEDJ265

UV Spectra Batten 12 x 5W UV LEDs

Conel MBUS Easy CME8i USER 'S GUIDE

Quick Start M!DGE / MG102 Wireless Router 6/13/2017

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Slimline CW & WW Series

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

DMX LED Starcloth Systems

Performer 18 RGBWA MKII

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

User Module. AT Modem Emulator APPLICATION NOTE

EZ864 UMTS Terminal Telit Cellular GSM Engine

User Module. Modbus RTU2TCP APPLICATION NOTE

MICRON DJ Booth Tri-colour Starcloth

XEC supercap (v. 1.0)

Quick Start M!DGE / MG102 Wireless Router 11/16/2011

Vortex. User Manual. Order code: EQLED073

Microbar Multi System

ELAN3-ALARM ETHERNET COMMUNICATOR

Fusion Saber. User Manual. Order code: EQLED070

UMTS router UR5i v2 and UR5i v2 SL USER S GUIDE

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

LIGHT BRICK - 12 X 3W TRI-COLOUR

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

HSPA+ Industrial Router. UR5i v2 Libratum USER S MANUAL

Kvaser PCIEcan 2xHS v2 User s Guide

Endura 1Q120 RGBW COB Exterior Fixture

FTP1 Single Channel LED DMX Driver

USER MANUAL. VP-311DVI Automatic DVI/Audio Switcher MODEL: P/N: Rev 3

ISMG Solar Inverter. General Description. Type Selection. Ordering Key ISMG 1 50 EN. Approvals RD 1663/2000 RD 661/2007 DK5940 VDE

Extension module for graphic Web functions for one automation station

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Island bus expansion module

User Manual Revision English

User module PIM SM APPLICATION NOTE

EasiLED 4 DMX Controller

CDMA router CR10 USER S MANUAL

EX-RC1 Remote I/O Adapter

Brief Overview. Vehicle Terminal MFT12 (B183) Version: 1.10

COMPACT eco -DIN Document Rev1

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Extension module for Web functions generic

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

Version 1.0. Table of contents

CDMA/UMTS router UCR11 v2 USER S MANUAL

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Flexoled FTP3HP RGB LED DMX Driver

Transcription:

Expansion Port RS485/RS422 www.lucom.de info@lucom.de USER S MANUAL

USED SYMBOLS Used Symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible problems, which can arise in specific cases. Information, notice information, which contains useful advice or special interest. GPL License Source codes under GPL license are available free of charge by sending an email to: info@conel.cz. Conel s.r.o., Sokolska 71, 562 04 Usti nad Orlici, Czech Republic Manual issued in CZ, February 9, 2016 i

CONTENTS Contents 1 Safety instruction 1 2 Product disposal instructions 2 3 Description of expansion port 3 4 Choice of interface and power supply 4 5 Connection of connector 5 5.1 Connection of RS485 connector.......................... 5 5.2 Connection of RS422 connector.......................... 7 6 Technical parameters 9 6.1 State indication.................................... 9 6.2 Product marking................................... 9 6.3 Technical specifications............................... 10 7 Recommended literature 11 ii

LIST OF FIGURES List of Figures 1 Connection of jumpers for external and internal power supply.......... 4 2 Connection of jumpers for RS485 and RS422................... 4 3 RS485 connector................................... 5 4 RS485 Connecting the meter to the router with cable length of <10 m..... 6 5 RS485 Connecting the meter to the router with cable length of >10 m..... 6 6 RS422 connector................................... 7 7 RS422 Connecting the meter to the router with cable length of <10 m..... 8 8 RS422 Connecting the meter to the router with cable length of >10 m..... 8 9 Expansion port label................................. 9 iii

LIST OF TABLES List of Tables 1 Connection of RS485 connector.......................... 5 2 Connection of RS422 connector.......................... 7 3 State indication.................................... 9 4 Product marking................................... 9 5 Technical specifications............................... 10 iv

1. SAFETY INSTRUCTION 1. Safety instruction Please, observe the following instructions: The expansion port must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the communication module in prescribed applications and environments. Use only the original Conel company accessories. Thus you will prevent possible health risks and damage to the devices and ensure compliance with all relevant provisions. Unauthorised adjustments or use of unapproved accessories may result in damage to the expansion port and breach of applicable laws. Use of unapproved adjustments or accessories may lead to cancellation of guarantee, which has no effects on your legal rights. Do not expose the expansion port to extreme conditions. Protect it from dust, moisture and heat. 1

2. PRODUCT DISPOSAL INSTRUCTIONS 2. Product disposal instructions The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environment. This product contains high quality materials and components which can be recycled. At the end of it s life this product MUST NOT be mixed with other commercial waste for disposal. Check the terms and conditions of your supplier for disposal information. 2

3. DESCRIPTION OF EXPANSION PORT 3. Description of expansion port RS485/RS422 expansion port can be fitted to PORT1 and PORT2. This expansion port is designed as an addition of router s board that allows v2 routers to direct use of additional hardware interfaces for Conel routers and modems. This interface is physically run into the RJ45 connector of the router or modem. RS485/RS422 board allows user to use jumpers to select RS422 or RS485 interface. Using jumpers is also possible to select the power supply of the expansion port. A more detailed description of interface choice, respectively choice of external or internal power supply can be found in the next chapter (4. Choice of interface and power supply). 3

4. CHOICE OF INTERFACE AND POWER SUPPLY 4. Choice of interface and power supply External or internal power supply of expansion port RS485/RS422 port can be selected by plugging jumpers J2 and J3 on the board of this port. If external power supply is required, jumpers J2 and J3 must be connected to pins 1-2. Internal power supply requires linking pins 2-3 on jumper J2 and J3. The behavior of the port is determined by plugging jumpers J4, J5 and J6. In case the RS485 interface is required, J4 and J5 jumpers must be linked (connected) and J6 jumper must be disconnected. If RS422 interface is required, J4 and J5 jumpers must be disconnected and J6 jumper must be connected. Precise placement of jumpers is shown in figures below. Internal power supply is recommended to use only in case if it is not possible to ensure external power supply. If internal power supply is selected, RS485/RS422 converter is not galvanically isolated. Figure 1: Connection of jumpers for external and internal power supply Figure 2: Connection of jumpers for RS485 and RS422 4

5. CONNECTION OF CONNECTOR 5. Connection of connector 5.1 Connection of RS485 connector Panel socket RJ45. Pin Signal mark Description Data flow direction 1 GND Signal and supply ground 2 GND Signal and supply ground 3 TxRx- RS485 B (-) Input/Output 4 TxRx+ RS485 A (+) Input/Output 5 TxRx- RS485 B (-) Input/Output 6 TxRx+ RS485 A (+) Input/Output 7 +12 V EXT External power supply 8 +12 V EXT External power supply Table 1: Connection of RS485 connector Figure 3: RS485 connector Important notices: ATTENTION! Way of power supply is selected on the expansion port RS485 using jumper! Signals 3-5 and 4-6 are linked inside of the router. If galvanic isolation is required, the converter must be powered by an external power supply (if internal power supply is selected, the converter is not galvanically isolated). 5

5. CONNECTION OF CONNECTOR Example of connecting the meter to the router with data cable length of <10 m: Figure 4: RS485 Connecting the meter to the router with cable length of <10 m Example of connecting the meter to the router with data cable length of >10 m: Figure 5: RS485 Connecting the meter to the router with cable length of >10 m Note: When the length of the RS485 data cable is over 10 m, it is necessary to use overvoltage protections on the router side. 6

5. CONNECTION OF CONNECTOR 5.2 Connection of RS422 connector Panel socket RJ45. Pin Signal mark Description Data flow direction 1 GND Signal and power supply ground 2 GND Signal and power supply ground 3 RxD- Receive data (-) Output 4 RxD+ Receive data (+) Output 5 TxD- Transmit data (-) Input 6 TxD+ Transmit data (+) Input 7 +12 V EXT External power supply 8 +12 V EXT External power supply Table 2: Connection of RS422 connector Figure 6: RS422 connector Important notices: ATTENTION! Way of power supply is selected on the expansion port RS422 using jumper! If galvanic isolation is required, the converter must be powered by an external power supply (if internal power supply is selected, the converter is not galvanically isolated). 7

5. CONNECTION OF CONNECTOR Example of connecting the meter to the router with data cable length of <10 m: Figure 7: RS422 Connecting the meter to the router with cable length of <10 m Example of connecting the meter to the router with data cable length of >10 m: Figure 8: RS422 Connecting the meter to the router with cable length of >10 m Note: When the length of the RS422 data cable is over 10 m, it is necessary to use overvoltage protections on the router side. 8

6. TECHNICAL PARAMETERS 6. Technical parameters 6.1 State indication LED diodes indications Green LED Yellow LED Indicates receiving data Indicates data transmission Table 3: State indication State indication is supported from the fourth revision of RS485/RS422 board. 6.2 Product marking Trade name Type name Power supply XC-RS485/XC-RS422 XC-485-422 Internal/external power supply Table 4: Product marking Figure 9: Expansion port label 9

6. TECHNICAL PARAMETERS 6.3 Technical specifications Expansion port RS485/RS422 Power supply External Internal Input power Consumption Temperature Operating temperature Storage temperature Standards Emission Immunity Safety RS485 specifications (ČSN EN 1434) Max. number of devices (each 1,5 ma) Maximal bit rate Short circuit resistance Max. cabel length (300 Bd, 200 nf/km) +10 30 V +3,3 V Max. 1 W Max. 4 ma -30 C to +60 C -30 C to +85 C EN 55022/B ETS 300 342 EN 60950 256 38400 bps permanently 1200 m Table 5: Technical specifications 10

7. RECOMMENDED LITERATURE 7. Recommended literature [1] Conel: Application guide Expansion port mounting, [2] Conel: Configuration manual for v2 routers 11