PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Similar documents
PT35. Dual Pulse Timer Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

INSTRUCTION MANUAL. AquiStar GDL. Dissolved Oxygen Datalogger

User Guide. Control Box. RoscoLED TM.

Global Water Instrumentation, Inc.

Aqua4Plus 2.0. Control Software for LevelSCOUT, BaroSCOUT, PT2X, CT2X PROUDLY MADE IN THE USA

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

CA-A480-A Elevator Controller. Reference & Installation Manual

zpen-1080p Features zpen-1080p Layout

2-Way Wireless I/O Expander Installation Guide

SD1306. Speed Dome IP Camera. Quick User Guide

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

V-9939B MICROPHONE ADAPTER

HVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

AEXX-349 SERIES REMOTE DISPLAYS

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

EZ-LIGHT SP Series Signal Light

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

Remote Refrigeration Control

Automated Tuner System Power Distribution Hub

VIP-812A DUAL NETWORKED STATION PORT

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

90130, 90131, POP DISPLAY ASSEMBLY INSTRUCTIONS

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

VIP-480AL IP One-Way Horn

Model A7BS

INSTALLATION INSTRUCTIONS

Woolich Racing. USB ECU Interface User Guide

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

DCM Digital Control Modules

Digital Lighting Systems, Inc.

Rack Power Distribution Unit AP7530, AP7540

S82S (3/7.5-W Models)

Kramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor

Zonit μats TM Users Guide μats1-lv Version 1.2

Broadband Automatic Disconnect Switch. User Manual

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

Wall. No opening (Example: LA-030-W)

SECURE/NONSECURE LED SIGN USER MANUAL

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

MPP200 User s Manual

Kramer Electronics, Ltd. USER MANUAL. Model: VP-111. XGA Line Driver

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

TOUCHBOX. iphone I N S T R U C T I O N M A N U A L

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

VIP-148AL IP Talkback Horn

INSTRUCTION MANUAL. Reading. AquiStar Smart Sensors. With an INW Panel Meter

ETConcept Systems Engineering. User s Guide

Turbo. Tubidity Smart Sensor with Data Logging ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

PIM-Mini Pulsed Current Source Operation Manual

PSA200 User s Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

WLS28-2 Dual Color LED Strip Light

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

CUBE Micro Station User Guide

WLC60 Heavy Duty Stainless Steel LED Light

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Progressive Industries, Inc. EMS Electrical Management System

I/O Expansion Box Installation & Operator s Instruction Manual

Digital Lighting Systems, Inc.

SP-C1 Mobile Docking Station Installation Guide

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

Digital Lighting Systems, Inc.

Hybrid AC Driver [GCNC-1110]

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

OCEANIC SYSTEMS MULTIPLE ENGINE DISPLAY Part Numbers: 4161 USER MANUAL

SA SERIES Arlingate Lane, Columbus, Ohio (614)

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Kramer Electronics, Ltd. USER MANUAL

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

XS/SC26-2 Safety Controller Quick Start Guide

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

THECHARGEHUB.COM. User Manual. For Square & Round Models

Superchips 1705 MAX MicroTuner Ford Powerstroke 7.3L Turbo Diesel Vehicles Vehicle Programming Instructions

Agility 2-Way Wireless Slim Keypad

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

BLUETOOTH SPEAKER. for ipod/iphone/ipad/android. User s Manual. Item #TA-11BTSP. PC Mac Ultrabook COMPATIBLE BLUETOOTH WIRELESS USB

Number of input channels

TSD-SEQ6 Sequencer Controller

Global Water globalw.com. Global Water. Instrumentation, Inc.

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

Sonic Ruptor 400. User Manual

PIXIM Micro Dome Camera

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

SLM Series Slot Sensors

Transcription:

PD10 Pulse Divider Instructions PROUDLY MADE IN THE USA ISO 001:200 Certified Company

General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Installation Mounting...Page 4 Power Source...Page 4 Connections and Settings PD10W/LMI Pump...Page PD10W/Non-LMI Pump...Page Settings...Page Troubleshooting Problem...Page Probable Causes...Page Things to Try...Page Warranty Seametrics Limited Warranty...Page Seametrics 23.2.024 Page 2 seametrics.com

GENERAL INFORMATION Designed for use as a meter accessory, the PD10 Pulse Divider is used primarily for pacing electronic metering pumps. Any number from one to can be set on rotary switches. Each time the divider has received the set number of pulses from the meter, it puts out one pulse to stroke the pump. The PD10 is also useful in boiler and cooling tower feed and bleed operations, and for lowering frequency output of high frequency meters. Compatible with all Seametrics flow meters, the PD10 creates a programmable pulse meter with an easily adjustable pulse rate. The PD10 is mounted by attaching it to the metering pump with the included double-backed, pressure-sensitive tape. Alternatively, the control can be wall mounted with screws using the mounting brackets that extend out either side. FEATURES Protective cover Rotary Switches (4) Mounting Holes: (Double-backed pressure-sensitive tape also supplied standard) Potted for environmental protection Wall (Pump) housing 2 cable to leads or metering pump connector Seametrics connector for plug-in meter connection Seametrics 23.2.024 Page 3 seametrics.com

GENERAL INFORMATION / MOUNTING / POWER Specifications* Enclosure Epoxy-encapsulated ABS housing with cover Temperature 0 to 130 F (-1 to C) Divider Range 1 to Setting Mechanism Rotary Switches Power 30 Vdc @ 4 ma Maximum Sensor Load 20 ma Maximum Input Frequency 30 Hz (pulses/second) Maximum Output Frequency Hz (pulses/second) Output Solid state relay; 0 20 V, 10 ma max AC/DC Output Pulse Width 0.1 second Input Connection Seametrics connector Output Connection Pump connector on 24 inch lead Environmental NEMA 4X, IP * Specifications subject to change. Please consult our web site for current data (seametrics.com) Mounting Power Source The PD10 is mounted by attaching it to the metering pump with the included double-backed, pressure-sensitive tape. Alternatively, the control can be wall mounted with screws using the mounting brackets that extend out either side. Power for the PD10 can be supplied by the metering pump if the pump has a sensor power supply. This is the case with LMI externally-paced metering pumps. Some pumps require an external power supply, available from Seametrics. LMI and Seametrics connectors are available. CAUTION: Power supplies 1 Vdc and higher must be regulated to prevent damage to the PD10 from voltages exceeding it's 30 V allowable maximum supply voltage caused by AC line variations and light loading. Seametrics 23.2.024 Page 4 seametrics.com

CONNECTIONS AND SETTINGS PD10W/LMI Pump The 24" pigtail that extends from the PD10W connects to an LMI metering pump and is connected as shown. The input connector on the control mates with any threepin Seametrics connector. (Meters or flow sensors to be used with a PD10W should be ordered with Seametrics connectors.) LMI Pump PD10W PD10 PULSE DIVIDER To adjust divider, disconnect from power then remove cover and set switches Settings The four numbered rotary switches marked "1000", "100", "10", and "1" control the ratio of meter pulses to pump strokes. Before setting the switches, disconnect power to the unit by removing the connector from the pump or unplugging the power adapter. To set any four-digit number, rotate the dials to the appropriate numbers. For example, to set 121, set the four switches to "1", "", "2", and "1". Any unused switches should be set to zero. For example, to set, position the dials to "0", "0", "0", "". See samples below. LMI Connector (supplied with PD10W) Meter Seametrics Sensor Connector (order with flow meter) 4 3 1 2 1. Auxiliary Power Source 2. Pulse Input 3. Ground 4. No Connection 1 4 Sockets Sockets -0 Option -10 Option 2 3 1. Remote On 2. Ground 3. Pulse Input 4. Aux. Power Source. Not Used Sockets 1. Ground 2. Input Signal 3. Sensor Power 4. + 30 Vdc* *CAUTION: If power is supplied to the flow sensor from the PD10, ensure that the voltage supplied to the sensor does not exceed the sensor's allowable maximum input voltage. 1 2 3 (Set Leading Switches To Zero) Setting Examples PD10W/Non-LMI Pump If a metering pump is used that requires a connection other than the LMI connector supplied, cut the LMI connector off. Connect the PD10W to the pump using the diagram below in conjunction with the wiring diagram in the pump manual. PD10 POWER + + OUTPUT Red Black Green White 30 Vdc Ground Signal + Common The input connector on the control mates with any threepin Seametrics connector. (Meters or flow sensors to be used with a PD10W should be ordered with Seametrics connectors.) Seametrics 23.2.024 Page seametrics.com

TROUBLESHOOTING Problem Probable Causes Things to try Metering pump not stroking Meter dials not turning Check visually, then check for adequate flow Meter pickup not working Remove from meter, check with a magnet Pump connector not plugged in all the way Check or tighten threaded locking ring (LMI) Pump doesn't supply power to the PD10 Check pump manual, add power supply PD10 set to large number or all zeros Check rotary switches, especially for leading zeros. Pump strokes continually Pump not set for external pacing Check pump manual and selector switch Pump doesn't stroke often enough or too often PD10 set for wrong number Review setting section, check rotary switches Multiple contacts from meter Set PD10 to 1 contact/pump stroke (0001) and see if the pump strokes once for each magnet revolution Meter ordered with wrong pulse rate Check meter model/serial tag Seametrics 23.2.024 Page seametrics.com

SEAMETRICS LIMITED WARRANTY The limited warranty set forth below is given by Seametrics, with respect to Seametrics and INW brand products purchased in the United States of America. Seametrics warrants that products manufactured by Seametrics, when delivered to you in new condition in their original containers and properly installed, shall be free from defects in material and workmanship. Seametrics products are warranted against defects for a period of two (2) years from date of installation, with proof of install date. If no proof of install date can be provided, warranty period will be two (2) years from date of shipment from Seametrics, as defined on Seametrics invoice. Seametrics obligation under this warranty shall be limited to replacing or repairing the part or parts, or, at Seametrics option, the products, which prove defective in material or workmanship. The following are the terms of Seametrics limited warranty: a. Buyer must give Seametrics prompt notice of any defect or failure and satisfactory proof thereof. b. Any defective part or parts must be returned to Seametrics factory or to an authorized service center for inspection. c. Buyer will prepay all freight charges to return any products to Seametrics factory, or another repair facility. as designated by Seametrics. d. Defective products, or parts thereof, which are returned to Seametrics and proved to be defective upon inspection, will be repaired to factory specifications. e. Seametrics will deliver repaired products or replacements for defective products to the buyer (ground freight prepaid) to the destination provided in the original order. f. Products returned to Seametrics for which Seametrics provides replacement under this warranty shall become the property of Seametrics. g. This limited warranty covers all defects encountered in normal use of Seametrics products, and does not apply to the following cases: i. Loss of or damage to Seametrics product due to abuse, mishandling, or improper packaging by buyer ii. iii. iv. Failure to follow operating, maintenance, or environmental instructions prescribed in Seametrics instruction manual Products not used for their intended purpose Alterations to the product, purposeful or accidental v. Electrical current fluctuations vi. vii. viii. ix. Corrosion due to aggressive materials not approved for your specific product Mishandling, or misapplication of Seametrics products Products or parts that are typically consumed during normal operation Use of parts or supplies (other than those sold by Seametrics) which cause damage to the products, or cause abnormally frequent service calls or service problems h. A new warranty period shall not be established for repaired or replaced material, products, or supplied. Such items shall remain under warranty only for the remainder of the warranty period on the original materials, products, or supplies. i. In the event that equipment is altered or repaired by the buyer without prior written approval by Seametrics, all warranties are void. Damage caused by equipment or accessories not manufactured by Seametrics may void the product s warranty. j. SOFTWARE: The Seller grants the user a non-exclusive license to use Seametrics software, according to the following limitations and conditions: i. The user may install the software on one or more desktop or laptop computers. ii. iii. iv. All title and intellectual rights to the software are owned by Seametrics. No copies may be made or distributed except as described above. The user may not modify or reverse-engineer the software. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY. NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLIED TO THE PRODUCTS AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED WARRANTY STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS MENTIONED ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCTS, SHALL BIND SEAMETRICS. SEAMETRICS SHALL NOT BE LIABLE FOR LOSS OF REVENUES, OR PROFITS, OR INCONVENIENCES, EXPENSE FOR SUBSTITUTE EQUIPMENT OR SERVICE, STORAGE CHARGES, LOSS OF DATA, OR ANY OTHER SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGE CAUSED BY THE USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS, REGARDLESS OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF SEAMETRICS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST SEAMETRICS BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY SEAMETRICS AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING THE FOREGOING, YOU ASSUME ALL RISK OF LIABILITY FOR LOSS, DAMAGE, OR INJURY TO YOU AND YOUR PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS NOT CAUSED DIRECTLY BY THE NEGLIGENCE OF SEAMETRICS. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. SIMILARLY, SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF CONSEQUENTIAL DAMAGE, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS; HOWEVER, YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. Seametrics 23.2.024 Page seametrics.com

Seametrics 102 2nd Avenue South Kent, Washington 032 USA (P) 23.2.024 (F) 23.2.02 1.00..13 seametrics.com LT-200031r1.1-201003 /3/201