E320 Quick Start Guide

Similar documents
C2000 and C4000 Hardware Quick Start Guide

SRP Field Upgrade Installation Instructions

C-series Platforms C2000 and C4000 Field Replaceable Unit Installation Instructions

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

SDRAM Installation Instructions

Maintaining E-Series Routers

Maintaining the ERX System

SRX 5600 Services Gateway DC Power Supply Installation Instructions

Maintaining the ERX System

TX Matrix Cable Shelf Assembly Installation Instructions

Quick Start. M160 Internet Router. Juniper Networks, Inc North Mathilda Avenue Sunnyvale, CA USA

Junos WebApp Secure 5.0 Hardware Guide

H3C S12500 Routing Switch Series

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Routing Engine, MCS, and CB Installation Instructions

Conversion Instructions for SSG 500M-series Security Devices and J-series Services Routers

Juniper Secure Analytics Quick Start Guide

Installing Power Modules

Removing and Installing the ISA and the ISM

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Conversion Instructions for SSG 300M-series Security Devices and J-series Services Routers

QFX10008 Switch Quick Start Guide

This section describes the software and hardware requirements for the module.

SRX 5600 and SRX 5800 Services Gateway Routing Engine Installation Instructions

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the MWAM CHAPTER

M40e and M160 CIP Installation Instructions

MX480 3D Universal Edge Router

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

Replacing the Power Supply

EXN4000 Storage Expansion Unit Installation and Setup Instructions

M160 Internet Router Release Notes

How to Set Up Your SRX4100 Services Gateway

Installing the Cisco Unified Videoconferencing 3545 MCU

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installing the Cisco SFS 3504 Server Switch

Switch Interface Board (SIB) Installation Instructions

NI PXI-1042 Series Power Supply Shuttle

ACX5448 Universal Metro Router Quick Start Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Maintaining the Cisco Catalyst 5500 Multiswitch Router

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide

Preparing to Install the VG248

Installation Job Aid for VSP 4850GTS

Juniper Networks G10 CMTS

MX240 3D Universal Edge Router Quick Start

Installing the Cisco MDS 9020 Fabric Switch

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Quick Start Guide S X. 1. Unpacking the Switch. 2. Identifying Your System. Front View

Installing the Cisco 2524 and Cisco 2525 Routers

J-series Services Router Crypto Accelerator Module Installation Instructions

Installation and Maintenance

Installation Job Aid for Ethernet Routing Switch 5900 Series

Power Supply Installation

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

IBM Systems. Quick start guide for IBM System p5 505 ( )

How to Set Up Your SRX300 Services Gateway

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Installing a Network Module

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

How to Set Up Your SRX550 High Memory Services Gateway

RMB Peripheral Units Installation Guide

Installing and Upgrading Memory and Virtual Private Network Modules

Installation Job Aid for VSP 4450GTX-HT- PWR+

N3240 Installation and Setup Instructions

Power Supply and Fan Module Installation

Installing the Cisco AS5400XM Universal Gateway

Installing or Replacing Modules, Fan Trays, and Power Supplies

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

1 Getting Started Installing & Configuring

TRC-190 User s Manual

Installation and Configuration Guide

Installing the Cisco XR Router

Installing and Removing SDRAM and DRAM

AI130 AIswitch Series 130 Chassis Installation Guide

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Installation Job Aid for Ethernet Routing Switch 3600 Series

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Installing a Network Module

N3150 Installation and Setup Instructions

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

M-series and T-series Routing Engine and MCS Installation Instructions

NI PXIe-1062Q Power Supply Shuttle

Installing the DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards in the Cisco ONS MA

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Dell Networking S4810 Open Networking (ON) Getting Started Guide

DX 32xx and DX 36xx Quick Start

How to Set Up Your SRX340 Services Gateway

Dell SC460 Expansion Enclosure Getting Started Guide

DX Application Acceleration Platform Quick Start

Rack Installation Instructions

Installing the Interface Line Card in the Cisco cbr Chassis 6

Quick Start Guide. Dell Force10 E300, E600i, and E1200i Systems

Codian MSE 8000 Media Services Engine

Port Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline

ACX2200 Universal Access Routers Quick Start

Quick Installation Guide 4 Slot Chassis-Based Switch

Transcription:

E-series Routing Platforms E320 Quick Start Guide Release 7.0.x Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, CA 94089 USA 408-745-2000 www.juniper.net Part Number: 162-01171-00, Revision A00

Product Reclamation and Recycling Program Juniper Networks is committed to environmentally responsible behavior. As part of this commitment, we work to comply with environmental standards such as the European Union s Waste Electrical and Electronic Equipment (WEEE) Directive and Restriction of Hazardous Substances (RoHS) Directive. These directives and other similar regulations from countries outside the European Union regulate electronic waste management and the reduction or elimination of specific hazardous materials in electronic products. The WEEE Directive requires electrical and electronics manufacturers to provide mechanisms for the recycling and reuse of their products. The RoHS Directive restricts the use of certain substances that are commonly found in electronic products today. Restricted substances include heavy metals, including lead, and polybrominated materials. The RoHS Directive, with some exemptions, applies to all electrical and electronic equipment. In accordance with Article 11(2) of Directive 2002/96/EC (WEEE), products put on the market after 13 August 2005 are marked with the following symbol or include it in their documentation: a crossed-out wheeled waste bin with a bar beneath. g002313 Juniper Networks provides recycling support for our equipment worldwide to comply with the WEEE Directive. For recycling information, send e-mail to recycling@juniper.net indicating the type of Juniper Networks equipment that you wish to dispose of and the country where it is currently located, or contact your Juniper Networks account representative. Products returned through our reclamation process are recycled, recovered, or disposed of in a responsible manner. Our packaging is designed to be recycled and should be handled in accordance with your local recycling policies.

Quick Start Overview This guide is an abridged version of the E320 router installation documentation and is intended for experienced installers who want to expedite the installation process. Follow the steps in this guide to get your E320 router up and running quickly. 1. Preparing the Site Ensure that your installation site meets the requirements in Table 1. Table 1: Router Specifications Category Ambient operating temperature Ambient operating humidity Heat dissipation Voltage Current Power Redundancy (input power) Space requirements Specification (NEBS GR-63-CORE compliant) Long term: 41 to 104 F (5 to 40 C) Short term: 23 to 122 F ( 5 to 50 C) Long term: 5% to 85% (noncondensing) Short term: 5% to 95% (noncondensing) 4800 W, 16380 BTU/hour maximum 40 to 72 VDC 100A @ 48 VDC 4800 W maximum 2 independent line feeds 3 feet (90 cm) behind router or rack Do not block air vents on front, sides, top, or back of the router To complete the installation of the router in a rack, you need: A Phillips screwdriver Eight 10-32 x 3/8 Phillips screws (provided with the router) for each router to be installed For detailed installation guidelines and considerations, see E320 Hardware Guide, Appendix B, Installation Guidelines and Requirements. Quick Start Overview 1

2. Installing the E320 Router You can install up to three E320 routers in a single 7-ft. (2.1-m) rack. We recommend that you use a standard EIA distribution rack. See Figure 1. WARNING: Three people are required to install the router in a rack: two to lift the system into position and one to screw it to the rack. CAUTION: To maintain airflow requirements, a plenum must be installed above the router before any piece of equipment (other than an E320 router) is installed above the router. This plenum is available from Juniper Networks. Plenums are not required when E320 routers are installed above one another because the router has a built-in plenum at the bottom. WARNING: Do not use the cable management bracket as a handle to lift the router. To install the router in the rack: 1. With one person standing on the left side of the router and another standing on the right side, lift the router into the rack. 2. Position the router in its designated location in the equipment rack. Make sure the holes of the mounting brackets align evenly with the holes of the equipment rack on both sides. 3. Starting at the bottom of the router, have the third person secure the router in the equipment rack by using the 10-32 x 3/8 Phillips screws. 2 2. Installing the E320 Router

Figure 1: E320 Router Installed in a Rack Air exhaust Air exhaust Front of router Air exhaust via integrated plenum (occurs when another router is installed below) Air intake Air intake 3-ft. minimum (0.9-m) access space 7-ft. (2.1-m) rack g015312 2. Installing the E320 Router 3

3. Installing Modules If your router was delivered with modules installed, go to 4. Connecting Component Cables. If you need to install additional modules, continue with this section. For complete installation and safety information, see E320 Hardware Guide, Chapter 4, Installing Modules. CAUTION: When handling components, use an antistatic wrist strap connected to one of the router s ESD grounding jacks. This action helps to protect the module from damage by electrostatic discharge. Slots for line modules, switch route processor (SRP) modules, and switch fabric module (SFM) modules are located in the front of the router, while slots for input/output adapters (IOAs) and SRP IOAs are located in the rear. Modules mount vertically in the 15 slot chassis, numbered left to right (0 16). See Figure 2 and Figure 3 for front and rear views of the router and Table 2 for slot locations. Each slot holds a specific type of module. Table 2: Module Slot Locations Component Chassis Location Slot LM (line module) Front 0-5, 11-16 SRP module Front 6, 7 Blank filler panel Front Non-numbered empty slot between 6 and 7 SFM module Front 8, 9, 10 IOA Rear 0-5, 11-16 Upper bay: Adapter 0 Lower bay: Adapter 1 4 3. Installing Modules

Figure 2: E320 Router, Front View Fan tray behind bezel Line module SRP module Blank filler panel PCMCIA slot SFM module Air filter (optional) behind bezel g015301 ESD grounding jack 3. Installing Modules 5

Figure 3: E320 Router, Rear View Fan tray ESD grounding jack IOA (upper bay) SRP IOA IOA bracket Blank IOA filler panel (lower bay) Power distribution unit (PDU) Cable management bracket g015333 Installing an SRP Module or SFM Module Four of the five fabric slots (SRP and SFM modules) must have a module installed for the router to function. A minimum system configuration requires all three SFMs and at least one SRP module to be installed. To install an SRP module or SFM module: 1. Ground yourself by using an antistatic wrist strap or other device and connect it to one of the ESD grounding jacks on the chassis. 2. Choose the slot in which you want to install the module. SRP module slot 6 or 7 SFM module slot 8, 9, or 10 3. With a Phillips screwdriver, loosen the captive screws that secure the blank filler panel covering the empty chassis slot, if present, and remove the filler panel. 6 3. Installing Modules

4. Remove the module from its antistatic bag, being careful not to touch module components, pins, leads, or solder connections. 5. Verify that the ejectors are in the open position. 6. Slide the module into the chassis by placing it between the guides of the selected slot and pushing the module until it stops. The module stops sliding when the ejectors make contact with the front of the chassis. 7. Insert the module into the backplane by simultaneously depressing both ejectors, exerting forward pressure on the module. CAUTION: If you meet strong resistance when attempting to seat the module using the ejectors, remove it from the chassis and confirm that the slot is designed to hold the module. Also, be sure that you have aligned the top and bottom edges in the correct matching tracks. 8. Tighten the module s captive screws using the Phillips screwdriver. CAUTION: Tighten the captive screws completely before installing an adjacent module so that proper EMI gasket compression occurs. Failure to do this can make it difficult to install adjacent modules. Installing an IOA Shelf Use an IOA shelf (also called an IOA bracket) when installing half-height IOAs in the router. IOA shelves screw into the midplane between the upper bay (Adapter 0) and lower bay (Adapter 1). IOAs in the upper bay rest on the shelf, while IOAs in the lower bay use the guides on the bottom of the shelf to remain vertical. To install an IOA shelf: 1. Ground yourself by using an antistatic wrist strap or other device and connect it to one of the ESD grounding jacks. 2. Remove the blank IOA filler panel from the slot. 3. Align the shelf s guide pins with the corresponding holes in the midplane and insert the threaded shaft into the hole in the midplane between the upper bay and lower bay. Be sure the threaded shaft is visible from the right side. 4. Using a flathead screwdriver, tighten the screw snugly to secure the shelf. 3. Installing Modules 7

Installing a Line Module or an IOA This section describes the procedures for installing line modules and IOAs. NOTE: Install the IOA module before you install the corresponding line module; otherwise, the diagnostics fail and the line module s status is listed as inactive when you issue the show version command. If this occurs, remove and reinsert the line module. To install a line module or IOA: 1. Ground yourself by using an antistatic wrist strap or other device and connect it to one of the ESD grounding jacks. 2. Choose the slot where you want to insert the line module or IOA. NOTE: Line modules are in the front of the system and IOAs are in the back of the system. 3. With a Phillips screwdriver, loosen the screws that secure the blank filler panel covering the empty chassis slot, if present, and remove the filler panel. 4. Remove the line module or IOA from its antistatic bag, being careful not to touch module components, pins, leads, or solder connections. 5. Verify that the ejectors are in the open position. 6. Guide the line module or IOA into the chassis by placing it between the guides of the selected slot and pushing the module until it stops. The module or IOA stops sliding when the ejectors make contact with the chassis. 7. Insert the line module or IOA into the midplane by simultaneously depressing both ejectors and exerting forward pressure on the module. CAUTION: If you meet strong resistance when attempting to seat the line module or IOA using the ejectors, remove it from the chassis and confirm that the slot is designed to hold the component. Also, be sure that you have aligned the top and bottom edges in the correct matching tracks. 8. Tighten the module s captive screws using a Phillips screwdriver. CAUTION: Tighten the captive screws completely before installing an adjacent module so that proper EMI gasket compression occurs. Failure to do this can make it difficult to install adjacent modules. 8 3. Installing Modules

4. Connecting Component Cables You need the following items for proper installation: 1/8-inch flathead screwdriver 3/8-inch insulated wrench or 3/8-inch nut-driver No. 2 Phillips screwdriver Ground wires We recommend a minimum of 6-AWG ground wire. Two #10 kep nuts (supplied) to connect the ground (earth) wire to the ground terminal. PDU wiring We recommend a minimum of 4-AWG wire for the router with a dual stud terminal lug with 5/8-inch spacing. Consider the distance from the connection point and the configuration of the system when determining the size of wire used. Connecting to the IOA Modules Many of the E320 IOA modules use small form-factor pluggable transceivers (SFPs) as an interface to the network. Consult the SFP manufacturer s documentation for proper use. (See Figure 4.) Figure 4: Installing an SFP on an IOA Connection circuitry on base of SFP g015330 4. Connecting Component Cables 9

Connecting Timing Ports The SRP IOA has two input ports for external network clock sources (75-ohm E1 2.048-Mbps/T1 1.544 Mbps inputs with BNC connectors). The primary clock is labeled A; the secondary, redundant clock, is labeled B. (See Figure 5.) 1. Attach a BNC connector to Clock A s network timing port. 2. Attach the opposite end of the network timing cable to your network s clock source A. 3. Repeat steps 1 and 2 for the Clock B connections. Figure 5: SRP IOA Connections g015329 Connecting a Management Console 1. Insert a female DB-9 connector into the RS-232 CONSOLE port (Figure 5), and tighten the screws. 2. Connect the other end of the cable to your terminal s serial port (VT100/ANSI). Connecting to a Network 1. Insert an Ethernet cable (RJ-45) connector into the 10/100Base-T (RJ-45) port (Figure 5) on the SRP IOA until it clicks into place. 2. Connect the other end of the cable to the appropriate Ethernet network for an out-of-band connection. 10 4. Connecting Component Cables

5. Connecting Ground and Power Cables After you have correctly cabled the SRP IOA, you must attach grounding and electrical wires before you attempt system power-up. CAUTION: Switches may have inadvertently flipped to ON during shipping and installation. Follow these steps, referring to Figure 6 as needed: 1. System power Turn off all power sources and push all router power switches to OFF to turn off the router. 2. Ground Locate the grounding studs in the rear of the chassis, near the power inputs, and attach a grounding cable lead to each. We recommend a minimum of 6-AWG ground wire with a ring-style terminal. Connect the other end of the ground cable to the appropriate ground termination lead. 3. Power Inputs Remove the nuts and locking washers from both posts (-48 VDC and RTN) on a power input (A or B) using a 3/8-inch insulated wrench. Attach one negative (neutral) cable lead on the post labeled 48 VDC and another cable lead on the post labeled RTN. Replace the nuts and locking washers and tighten securely. Attach the opposite end of each wire to the appropriate leads on your power source. Figure 6: Connecting Power and Grounding Cables g015321 Power A leads Ground Power B leads NOTE: For more information on cabling your router for power, see E320 Hardware Guide, Chapter 5, Cabling the Router. 5. Connecting Ground and Power Cables 11

6. Powering On the E320 Router For specifications on the electrical requirements for the system, see E320 Hardware Guide, Appendix A, System Specifications. For details on the power consumed by the different modules, see the E320 Module Guide. 1. Verify that the power source is operational and turned on. 2. Inspect all grounding and power connections to the router chassis. 3. Confirm that all connections are secure. 4. Switch the power switches to ON. 5. Monitor the LEDs on the SRP modules and SFM modules to verify that the system is booting properly. See E320 Hardware Guide, Chapter 9, Troubleshooting, for information on status LEDs. 7. Configuring and Verifying Now that your router is powered on, you must assign an IP address to it, set up Telnet access, and set system variables. See E320 Hardware Guide, Chapter 7, Accessing E-series Routers and the JUNOSe System Basics Configuration Guide for more information. Assigning an IP Address 1. Enter the enable command at the User Exec prompt. host1>enable host1# 2. Set an IP address on the Ethernet interface: Substitute the slot number where the SRP module is located for the slotnumber variable. Use an IP address valid for the system. host1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. host1(config)#interface FastEthernet slotnumber/0 host1(config-if)#ip address 10.10.7.3 255.255.255.0 Setting Up Telnet Access Before you can access the system with Telnet, you must either configure a password for Telnet access or disable the password requirement from the management console. In the following example, you disable the password. 1. Enter the enable command. host1>enable host1# 12 6. Powering On the E320 Router

2. Enter the configure command. host1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. host1(config)# 3. Enter the line command. host1(config)#line vty 0 4 host1(config-line)# 4. Disable the password. host1(config-line)#no login Setting System Environment 1. Run Telnet from a host on the same Ethernet network as the system and enter the IP address of the system to open the Telnet session. 2. Enter the enable command. host1>enable host1# 3. Enter the configure command. host1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. host1(config)# The system is now in Global Configuration mode, from which you can configure the system. For example, you can set the router s name, clock, and environmental variables. See JUNOSe System Basics Configuration Guide, Chapter 2, Command-Line Interface. Troubleshooting If you encounter a system problem: 1. Make sure power connections are securely attached and all power switches are in the ON position. 2. Make sure each module is installed correctly and each cable is attached securely. 3. Observe the system s LEDs carefully. See E320 Hardware Guide, Chapter 9, Troubleshooting, for more detailed troubleshooting information. You can also open a support case with the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (from the United States, Canada, or Mexico) or 1-408-745-9500 (from elsewhere). 7. Configuring and Verifying 13

Configuring and Operating the Router Figure 7: E320 Router, Oblique View You are now ready to configure routing on your system. For specific routing configuration options available for the router, see the JUNOSe Systems Basics Configuration Guide. Fan tray behind bezel Ventilation grid Line module SRP module Blank filler panel PCMCIA slot SFM module Air filter (optional) behind bezel ESD grounding jack Cable management bracket g015302 Part Number: 162-01171-00, Revision A00 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, CA 94089 USA Phone 408 745 2000 or 888 JUNIPER Fax 408 745 2100 Juniper Networks, the Juniper Networks logo, NetScreen, NetScreen Technologies, the NetScreen logo, NetScreen-Global Pro, ScreenOS, and GigaScreen are registered trademarks of Juniper Networks, Inc. in the United States and other countries. The following are trademarks of Juniper Networks, Inc.: ERX, ESP, E-series, Instant Virtual Extranet, Internet Processor, J2300, J4300, J6300, J-Protect, J-series, J-Web, JUNOS, JUNOScope, JUNOScript, JUNOSe, M5, M7i, M10, M10i, M20, M40, M40e, M160, M320, M-series, MMD, NetScreen-5GT, NetScreen-5XP, NetScreen-5XT, NetScreen-25, NetScreen-50, NetScreen-204, NetScreen-208, NetScreen-500, NetScreen-5200, NetScreen-5400, NetScreen-IDP 10, NetScreen-IDP 100, NetScreen-IDP 500, NetScreen-Remote Security Client, NetScreen-Remote VPN Client, NetScreen-SA 1000 Series, NetScreen-SA 3000 Series, NetScreen-SA 5000 Series, NetScreen-SA Central Manager, NetScreen Secure Access, NetScreen-SM 3000, NetScreen-Security Manager, NMC-RX, SDX, Stateful Signature, T320, T640, and T-series. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. All specifications are subject to change without notice. Products made or sold by Juniper Networks (including the ERX-310, ERX-705, ERX-710, ERX-1410, ERX-1440, M5, M7i, M10, M10i, M20, M40, M40e, M160, M320, and T320 routers, T640 routing node, and the JUNOS, JUNOSe, and SDX-300 software) or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785. Copyright 2005, Juniper Networks, Inc. All rights reserved. Printed in USA. Revision History 7 September 2005 Revision 1