Fieldbus technology An Overview

Similar documents
IO-Link point-to-point communication.

Introduction to Fieldbus and DeviceNetworks

PROFIBUS and Integrated Safety architectures in Ex areas

Introduction to PROFIBUS for Process Automation

Your Global Automation Partner. Elevating Ethernet Intelligence: Implementing Ethernet Technology in Industrial Applications. White Paper - W1004

Point-to-point communication.

PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05

The PROFIBUS Family. PROFIBUS Expo, Perth November Andy Verwer Verwer Training & Consultancy Ltd Member of the PROFIBUS Association of Australia

ELECTRIC ACTUATORS with PROFINET interface

ELEVATING ETHERNET INTELLIGENCE:

Connect AS-I Gateways to PC for Configuration and Troubleshooting

Redundancy. For maximum plant availability.

PROFIBUS Workshop EN B U I L D I N G P R O C E S S M A N U F A C T U R I N G EUROPEAN FIELDBUS STANDARD. Chapter 1 Date 11/04/99, page 1

PC-based Control for the Field Installation of PV and CSP Systems

PROFIBUS. Sharani Sankaran

Standards. Electromechanical Safety Switches. Industrial Safety Products 179

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

SINAMICS S120. Communication. Communication 2/7. Overview

L5353 Profibus-DP Communications Interface

Development of a Network Analyzer for PROFINET Standard

Automating the Industry. 5 th BISCI SOUTHEAST ASIA CONFERENCE

Introduction to Fieldbus Technology

HP 3D High Reusability PA12 is rated as UL94 HB, which is not applicable for most of the Fire Enclosures.

SIMATIC NET. Industrial Communication with PG/PC Volume 1 - Basics. Preface 1. SIMATIC NET in Industrial Communications. Basics of the OPC Interface 3

Industrial Fieldbus Technologies: Understanding the basics and simplifying your decision

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

FIELDBUS OVERVIEW Graham Traill 02/09/2015

POINT I/O Family. Chapter. Overview

SK CU4-PBR-C Part number:

1 Gigabit Industrial Ethernet field network delivers determinism and accommodates 10/100/1000 Mb TCP/IP field devices

MTL8000-2/x Series Modular I/O

Modulating control valve

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

Understanding Device Level Connection Topologies

S-series DeviceNet Interface Card

Industrial Ethernet Comparison for Motion Control Applications

Protection IP 67 in the field applications. Temperature Range 0 C (32 F) to 55 C (131 F)

DeviceNet - CIP on CAN Technology

ECONOMICAL INSTALLATION CONCEPTS. Murrelektronik is your partner. ÔÔMetal cutting machine tools. ÔÔAssembly and handling equipment

Revision of Previous Lectures

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

SK TU4-PBR Part number:

PROFINET The industrial Ethernet standard. This is my way

S-series DeviceNet Interface Card

Practical steps for a successful PROFIBUS. Project... Presented by:- Derek Lane Systems Manager - WAGO Ltd. The PROFIBUS Group - UK PROFIBUS

FIELDBUS TRAINING 1.01

FIeldbus. Sense it! Connect it! Bus it! Solve it! /03

Max Felser. PROFIBUS Manual. mmww. swwmt. A collection of information explaining. PROFIBUS networks

POINT I/O Family. Chapter. Overview

Modicon M580 The World First epac

PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: PROFIBUS Learning Outcomes, Order No: 4.

New Product Release Summary for 3M Authorized Sales Reps and Distributors 3M Industrial M12 Wiremount Connectors, 3N104 and 3N304 Series

Lecture 2. Basics of networking in automotive systems: Network. topologies, communication principles and standardised protocols

I/O Modules Active Stand-Alone: Interbus

General. Remote I/O A4/1.

AUMA 50 YEARS OF ELECTIC ACTUATON

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

Operating instructions Evaluation system for flow sensors VS / / 2013

IDS SAS. Station Automation System for Complex Applications

IE102: SCADA Programming, Maintenance & Troubleshooting

Chapter 1: Introduction

CANopen Characteristics

SIRIUS Motor Management and Control Devices

SMART INSTRUMENTS, FIELDBUS, ETHERNET AND INDUSTRIAL WIRELESS.

IPES/IES-0208 Series

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering.

MULTIPLE PROTOCOLS FOR VALVE ACTUATOR CONNECTIVITY

M242 COMPUTER NETWORS AND SECURITY

M-series Profibus DP Series 2 Plus Interface Card

GE Intelligent Platforms PAC8000 RTU

Myths and Actual Practice with Industrial Data Communications and Hazardous Areas. Steve Mackay IDC Technologies

Networks. In this lesson we will discuss: What do Networks do?

ECS servo system MCS servo motors

IS1 remote I/O. ready for the future

M-series Profibus DP Series 2 Plus Interface Card

The economical solution for continuous communication in automation

Lecture: Communication in PLC

REF IC012 PLC & SCADA Systems Feb $4,250 Abu Dhabi, UAE

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Basics of setting up. PROFIBUS-PA networks. Martin Ruck Siemens. Jason Nicholl Phoenix. Kris Hardaker United Utilities

MSI 100, MSI 200 Programmable Safety Controllers

Training Fees 4,250 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch

S-series Profibus DP Interface Card

Safety. Integrated safety technology for the most demanding requirements.

Intellis Network Control Monitors

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

ADVANCED SCADA CONTROL SYSTEMS

Partner for automation Water technology

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch

(Controller Area Network)

Training Venue and Dates September, 2019 $4,000 Dubai, UAE PLC & SCADA Systems Trainings will be conducted in any of the 5 star hotels.

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories

PROFIBUS PA Fault-Finding and Maintenance Tools

2. REAL-TIME CONTROL SYSTEM AND REAL-TIME NETWORKS

Trusted Strategic Partners in Process Automation. Alliance Member

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1

CHAPTER 2 - NETWORK DEVICES

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

MOVITRAC 31.. Frequency Inverter

Level 1: Physical Level 2: Data link Level 3: Network Level 4: Transport

Transcription:

An Overview 00 Introduction to fieldbus 00.1 Industry-standard solutions for automation from HARTING Present day and future automation solutions are evolving from being isolated applications solutions towards becoming industrialised networks. Whereas on the one hand offices are becoming ever more entwined with the production side, on the other hand, widely distributed automation sub systems are increasingly being installed. In order to combine both of these areas, ITbased systems are, in addition to the traditional fieldbus, gaining in importance. User demands for openness, all-round integration and straightforward control require high-performance devices and industry-standard network concepts. Hereby the customer benefits from savings in time and costs for planning, building, operating and maintaining his machines and plant. Apart from easy installation, network topology, cabling and connection concepts are considered to be among the more important criteria for the evaluation and therefore the acceptance of network products for use in industry. HARTING combines the competences of the world's leading manufacturer of industrial connections with networking competence to turn these customer requirements into actual solutions. This competence is underscored by HARTING's active participation in influential committees and working groups for standardisation. Starting with its classic connectors, HARTING creates comprehensive system solutions as well as network components to build industrial networks from a single source. These include, amongst others: l Connectors in robust designs and workmanship capable of standing up to industrial conditions as well as including technical features that correspond to industry requirements to suit various demands, for example, EMC requirements l Network components combine the characteristic features of connectors and an optimum harmony with industrial topologies l Networks fulfil user requirements with the use of optimum components 00.2 General information about fieldbus It is necessary in the course of advancing automation and decentralisation of measurement, sensor and drive technologies to create multi-vendor, open communication standards, which can link the different devices from various manufacturers and guarantee cross-system communication. This will result in remote sensors and actuators becoming ever more 'intelligent'; thus, communication will increasingly flow in both directions: l From the PLC (transmitter) to the sensors / actuators (receivers) l From the sensors / actuators (transmitters) to the PLC (receiver) Quality and safety reasons dictate that the transmission speeds of signals and messages will become more and more crucial for maintaining certain demands (for example, diagnostics, troubleshooting, safety-related data transmissions). And last but not least, the introduction of fieldbus will decisively lower wiring overheads as well as the susceptibility to faults of the connections between the field devices and the higher-level controls and systems. 00.3 The automation pyramid Based on the amount and number of the required components, the information to be transmitted within the different levels of a system can be portrayed in the form of a pyramid: 03

An Overview 04 The automation pyramid Bus systems provide the means for communication within the individual levels as well as between the different levels. That said, the following applies: the higher the level is, the slower the rate of transmission, but the greater the amount of data to be transmitted. The sensor / actuator level (field level) In this the lowest of the levels, sensors and actuators are used to control production and manufacturing processes. Process-related data is for example: l Liquid level l Pressure l Temperature l Flow rate l End positions l Rotational speeds l Control status l This data is read-in and processed at the field level. In addition to the normal process data, safety- and quality-relevant data is also read-in, processed and transmitted. Amongst other, these include alarm values, run times, analysis values and so forth. Data exchange takes place predominantly between different levels, and only seldom between the devices within the same level. For example, setpoint values are transmitted from, and actual measured values are transmitted to a higher-level controller. PROFIBUS, CANopen, DeviceNet and AS-Interface are known fieldbus protocols used at the field level as well as for communicating to the control level. The control or plant-floor level This control is positioned on the second level. Amongst others, the tasks covered by this level are: l Conditioning and processing the data received from the assigned sensors and actuators on the field level. l Administering several control and regulating modules l Carrying out automation and control tasks l Routing certain data to the system level l Visual display of data l... Typical devices for this level are, for example, programmable logic controllers (PLC) and regulators or CNC modules. Data exchange takes place both between and within the levels. For example, setpoint values are transmitted from a higher-level controller to the lower-level sensors and actuators. This data can equally be transmitted between the individual PLC modules within this level. PROFIBUS, CANopen and DeviceNet are the fieldbus systems used for the control level. PROFIBUS, CANopen, DeviceNet and Industrial Ethernet provide the link to the system level.

An Overview The control system or cell level This level is responsible for the monitoring, control and regulation of several processes. The tasks covered by this level are: l Conditioning and processing the data received from the assigned controllers and regulators from the control level l Administering several control and regulating modules l Carrying out higher-level automation and control tasks l Routing certain data to the process control level l Central point for visualisation of selected data l Typical examples of such devices are: programmable logic controllers (PLC) and PCs. Data exchange takes place both between and within the levels. For example, setpoint values are transmitted from a higher-level management system to the lowerlevel PLCs. This data can equally be transmitted between the individual PLC modules within this level. Industrial Ethernet is the fieldbus increasingly being used on the system level as well as for communication to the process control level. PROFIBUS, CANopen and DeviceNet are also utilised. The process control level and factory level These two levels serve predominantly to control larger systems or factory operating areas as well as higherlevel planning and control of the entire production. These two levels are of less relevance as far as fieldbus systems are concerned. On the process control level, Industrial Ethernet can be used for user-specific applications. 00.4 The layer model The 'Open Systems Interconnection Reference Model' (abbrev.: OSI Model) came into being in 1983 based on the experienced gained from using and developing TCP/IP as a standard for office communication. This reference model describes the OSI environment very abstractly. At least two open systems make up the OSI environment, these being connected to one another by means of a physical medium for the exchange of data. Having said that, each of these systems is an autonomous entity that can independently process and transmit data. According to OSI specifications, data exchange takes place in an open system in accordance with formal rules of communication, which were developed in accordance with the OSI reference model. In order to be able to use the OSI reference model on a system, the system has to be divided up into two categories. l Into data processing to perform a certain task and l Into the communication system solely responsible for transmission of data The rules applied to the system of communication are called protocols. These rules require that the messages using this communication to exchange data between the individual stations must be able to be subdivided into four different types: l Request l Indication l Response l Confirmation The OSI Reference Model is divided up into 7 layers. Each layer contains at least one instance specifying particular network functions.this instance can be compared with an independently functioning software module that carries out special tasks with the assistance of neighbouring instances. 05

An Overview Layer 6: Presentation Layer Layer 6 is responsible for character coding and conversion of data, monitor and file formats in a suitably readable form for the corresponding computer. Layer 7: Application Layer Layer 7 provides interactive services, such as writing and reading, for other network users. In doing so it provides an interface to the user programmes in PLC, PC and control systems. The OSI Reference model The tasks and functions are assigned to the individual layers as follows: Layer 1: Physical Layer Layer 1 (bit transmission layer) manages the physical medium for transmitting the individual bits of the telegram messages. This includes defining the transmitting medium (electrical cable, fibre-optic cable), connector assignment, type of modulation, transmission rate, signal level as well as further physical parameters such as the length of cable and more. Using the OSI Reference Model Layers 1 to 4 are responsible for the transmission of data between stations within the network. Layers 5 to 7 coordinate the interaction between the bus system and the user program of the computer in the respective station. The structure of the layers applies only to the internal sequence of communication. It has nothing to do with the control levels of automation engineering. Generally speaking, only the layers 1, 2 and 7 need be considered for industrial communication purposes by means of fieldbus systems. These layers are reduced even further for individual fieldbus systems (for example, PROFIBUS-DP or AS-Interface) in order to achieve increased transmission speeds. The following figure depicts a typical route taken by a message from the transmitter to the receiver. Layer 2: Data Link Layer Layer 2 is responsible for the bus access procedure as well as the fail-safe transmission of data packets from the transmitter to a receiver or several receivers (Multicast) or to all receivers (Broadcast). Layer 3: Network Layer Layer 3 supports the search and use of suitable transmission routes between the transmitter and receiver through the network, possibly via a communication PC. Layer 4: Transport Layer Layer 4 is responsible for the control of and error-free, logical delivery of telegrams. 06 Layer 5: Session Layer Layer 5 (communication layer) establishes, manages, synchronises and terminates communication between the participating stations of a bus communication. Example of message transmission by means of the OSI Reference Model

An Overview 00.5 Classifying the fieldbus systems Serial fieldbus systems are based on a time-division multiplex method. That means that the communicating partners must divide up the transmitting time between themselves, because only one station can occupy the bus for transmission purposes at a given time. The classification of the fieldbus systems can be made according to various aspects: l According to access procedures l According to topology l According to bus access protocols The link between the individual aspects is depicted in the following figure: Classifying the fieldbus systems Random bus access The bus assignment is not made according to a predefined concept. That means that all stations have the same rights and are always ready to receive messages. Where necessary, they can begin to transmit messages when the bus is not occupied. The access procedure used is called CSMA (Carrier Sense Multiple Access). The advantage of this access procedure is the eventcontrolled communication. Typical fieldbus protocols that function according to this principle are: l CANopen l DeviceNet l others systems with central master transfer In a bus system operating a centralised master transfer mechanism the master transfer function is fulfiled by one station only, which is defined as the master terminal. The master terminal cyclically queries all of the other network stations (slaves). The slaves are only permitted to transmit information following a request from the master. With this form of data transfer, a distinction is drawn between the different topologies: systems with decentralised master transfer The master function of a bus system employing a decentralised master transfer mechanism is distributed between several stations. In this case, a distinction is drawn between the differing access mechanisms: Deterministic master transfer Certain stations, the masters, are each permitted to transmit (token holders) for a defined time. Once this defined time has elapsed, the token, which provides the necessary authority to transmit, is passed on to the next master making it the active master. A logical ring is built up between the masters so that this process can be applied independently of the network topology. This process is known under the name of 'Token Passing'. Typical fieldbus systems that function according to this principle are: l PROFIBUS-FMS ( Message Specification) l PROFIBUS-DP (Decentralized Peripherals) l others Line topology Several stations are connected to a bus trunk cable by means of a stub line. The tree topology is an extended form of the line topology. The maximum length of such a cable is restricted by its electrical characteristics. Typical fieldbus systems that employ a line topology are: l AS-Interface ASI l others Ring topology Both ends of the trunk cable forming the bus system are connected to each other.that is the reason why no cable termination is required. The individual stations form a ring configuration. For data exchange purposes, both separate data telegrams from each station as well as accumulated frame telegrams are used for the transmission of master information. The accumulated frame telegrams contain data for all of the stations. Each station receives the data addressed to him, and attaches its own data to this telegram at a time determined by the master. INTERBUS is a typical example of a fieldbus system that uses ring topology. 07

classes for devices HARTING can draw on many years of extensive experience gained in achieving high protection classes for industrial environments (IP 65 and greater); all of which flows into the development of its family of devices. The protection class for these devices is achieved with corresponding housings and covers or by the interlocking of their connections. Depending on their protection class, the devices are protected from external mechanical influences (impacts, foreign objects, dust, and accidental touch contact) as well as ingress of moisture (water, cleaning agents, oils and other fluids). The protection class provided by a device is defined in the standards IEC 60 529 and DIN EN 60 529, which also contain a classification of the different degrees of protection. The table below offers an overview of the protection classes. In accordance with the above-mentioned standards, the degrees of protection are indicated as follows: Code letters First Index Figure Second Index Figure (International ) (Foreign protection) (Water protection) IP 6 5 Index figure No protection Degree of protection No protection accidental contact, Index figure no protection 0 0 large solid foreign contact with any large area by foreign hand and large 1 1 solid foreign with Ø > 50 mm contact with the fingers, medium protection solid 2 2 sized foreign foreign with Ø > 12 mm small solid Ø > 2.5 mm, protection 3 3 foreign tools, wires or similar objects with small foreign solid with Ø > 2.5 mm grain-shaped 4 4 foreign injurious interior injurious 5 5 deposits of dust ingress of penetration of 6 6 dust As 3 however Ø > 1 mm Full protection contact. dust deposits Total protection contact. dust 7 No protection water Drip-proof Drip-proof Spray-proof Splash-proof Hose-proof Protected flooding Protected immersion Degree of protection No protection water vertical water drips water drips (up to a 15 angle) diagonal water drips (up to a 60 angle) splashed water from all directions water (out of a nozzle) from all directions Protected temporary flooding Protected temporary immersion 08 8 Water-tight Protected water pressure Description according to DIN EN 60 529, IEC 60 529