Data center cabling design fundamentals

Similar documents
DATA CENTER CABLING DESIGN FUNDAMENTALS

European Data Centre Infrastructure Standards EN series. Rob Cardigan, Senior Product Manager Nexans Cabling Solutions

FiberGuide Optical Raceway Solutions. Comprehensive, long-term management for your growing fiber network

Fiber backbone cabling in buildings

Optimizing PON architectures maximizes electronics efficiencies. White paper

Bonding and grounding NETCONNECT copper cabling systems

White paper. Interleaved MIMO: Near-full MIMO performance, nearly half the costs

This document is a preview generated by EVS

Introducing the NG4access ODF Platform

EN EU Standard: Data Centre Facilities and Infrastructures. What s in it for me?

Miniature outside plant plug-and-play solutions. White paper

The changing route to the last mile

Outside plant solutions for multisystem operators

Fiber Backbone Cabling in Buildings

CommScope standard density fiber optic panels

(Data Center Networks & Cloud Computing Security)

InstaPATCH Cu Cabling Solutions for Data Centers

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on

Data Center Design and the ANSI/TIA-942 Standard

Implementation considerations for cabling supporting remote powering

Laying the groundwork for a new level of Power over Ethernet

IN-BUILDING WIRELESS BEST PRACTICES CHAPTER 5

Checklist for building an edge data center

Application Note. Data Center Standards and Layouts

Total Modular Data Centre Solutions

This document is a preview generated by EVS

Flexible wireless connectivity solutions

ETSI GS OEU 006 V1.1.1 ( )

Copper Cabling Standards

INTERNATIONAL STANDARD

Cabling a Data Center to TIA-942 Standard

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Standards-based Labelling: The Key to Effective Network Cabling Plan. Lin Huanyu Market Development, Regional Manager Brother International Singapore

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Uniprise Structured Cabling Solutions Guide

EUROPEAN DATA CENTRE STANDARDS

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Your network s path to its fiber future. Grow confidently with fiber solutions from an experienced partner

APC by Schneider Electric Elite Data Centre Partner

1.1 OVERVIEW OF THIS BOOK

Fiber Design for 1 Gigabit and 10 Gigabit Campus Backbone Applications

FiberGuide. Optical Raceway System. For more information, visit commscope.com

Thermal management. Thermal management

Fact sheet COPENHAGEN DATA CENTRE CAMPUS. Connect, transact and grow

This document is a preview generated by EVS

5G: Advancing the World of Connectivity

Server room guide helps energy managers reduce server consumption

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

Data Center Checklist

CommScope Multi-Tenant Data Center Solutions: A solid advantage from the critical infrastructure experts. Data Center Solutions

POWER AND THERMAL MANAGEMENT SOLUTIONS

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center

Fact sheet FRANKFURT DATA CENTRE CAMPUS. Connect, transact and grow

Cabling for Data Centres. Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari

Universal connectivity grid design guide

LSX Optical Distribution Frames

CERTIFICATION PLUS SM

take your data centre to the next level

SYSTIMAX structured cabling systems. High-performance infrastructure built on the science of innovation

BICSI NxtGEN & Global Data Center Standards Update

DATA CENTRE CODES AND STANDARDS

NETCONNECT. Structured Cabling Solutions Guide. Asia-Pacific Region

1.0 Executive Summary. 2.0 Available Features & Benefits

Product Brochure Eaton 93PR UPS kw

Fact sheet VIENNA DATA CENTRE CAMPUS. Connect, transact and grow

Modular plugs, accessories and tooling

Managing Density Managing Density in the Data Center: A Long-term Approach for the Future

INTERNATIONAL STANDARD

1.0 Executive Summary

Repeatable IT Hub Rooms

Data center applications standards reference guide

NEXT GENERATION Data Centres FOR NEW GENERATION. Technology

Cabling Best Practices Using Fast Channel TM Switch Connect. Marc Dunham, Methode - Data Solutions

An Overview of ISO/IEC family of Information Security Management System Standards

DATACOM CABINETS SOLUTION GUIDE

INTERNATIONAL STANDARD

European Framework Initiative for Energy & Envinronmental Efficiency in the ICT Sector BEFORE STARTING

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited.

CenturyLink Data Center Services Herndon, Virginia

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

Repeatable IT Hub Rooms

How You Can Optimize Passive Optical LAN Through Structured Cabling

Welcome. BICSI And BICSI Standards, An Overview. Presented by: Greg Sherry RCDD/NTS/WD BICSI European Region Director

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

Role of Copper Cabling in Datacentres

MTS Co-Location Hosting - MILAN

AMS6, Amstel Business Park Campus. Highly connected, Energy efficient data centre. Duivendrechtse kade 80A 1096 AH Amsterdam Netherlands

HUBER+SUHNER DCCT Training

1.0 Executive Summary. 2.0 Features and Benefits

IBM Site Enablement Services

Fact sheet DUBLIN DATA CENTRE CAMPUS. Connect, transact and grow

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Foreword. (dop) (dow)

VERTIV SERVICE CAPABILITY

INNOVATE DESIGN APPLY.

Transcription:

White paper Data center cabling design fundamentals Telecommunications cabling infrastructure requirements according the availability classes I-IV of EN 50600-2-4 www.commscope.com 1

Introduction With the completion by end of Q1 2016, the new European standard series (EN 50600-x) covering the design of Data Centre Facilities and Infrastructures will be a new a comprehensive European reference for all parties involved in designing, building and operating data centers. Developed by CENELEC, an in dependent, non-profit European standards organization, it is commercially neutral and internationally applicable by referencing ISO/IEC standards. As part of this standard series, the EN 50600-2-4 standard, officially released in January 2015, covers the Telecommunication Cabling Infrastructure. It is mainly focusing on design requirements for the different DC availability classes with strong emphasis on migration and growth. This white paper explains the EN 50600-2-4 in the context of the EN 50600-x standard series. Furthermore, the document highlights the requirements for fixed cabling infrastructures, cross-connect cabinets, equipment row cabinets, cable management and pathway systems according the data center availability classes. Contents The European standard series EN 50600-x Introduction & structure 3 Key advantages 4 Comparison with other standards/design concepts 5 Key benefits per target group 5 EN 50600-1: General concepts & availability classes 6 EN 50600-2-4: Telecommunications cabling infrastructure Content and structure 7 Cabling types 8 Point-to-point cabling 8 Fixed cabling 9 Availability classes and resulting cabling architectures 10 Cabling class 1 11 Cabling class 2 11 Cabling class 3 12 Cabling class 4 12 Specifications & requirements for the cabling classes 13 Requirements for cabinets/racks/frames 15 General requirements 15 Requirements for dimensions 15 Recommendations for cable management 15 Recommendations for overhead cabling 15 www.commscope.com 2

The European standard series EN 50600-x Introduction & structure This series of European standards specifies requirements and recommendations to support the various parties involved in the design, planning, procurement, integration, installation, operation and maintenance of facilities and infrastructures within data centers. These parties include: Owners, facility managers, ICT managers, project managers, main contractors Consultants, architects, building designers and builders, system and installation designers Suppliers of equipment Installers, maintainers It has been developed to address European demands regarding DC design: A European DC design standard was required with European applicable requirements Demand for a universally applicable DC design standard series which adopts a holistic approach covering all aspects of the design of DC facilities & infrastructures including management and operational information Support of European Commission s Code of Conduct on Data Centers Energy Efficiency Existing design schemes were driven by design resilience concepts rather than offering a business oriented assessment approach using a design vs. cost perspective The EN 50600-x series covers all design requirements for the entire set of facilities and infrastructures of a data center in separate standards. The following graphic shows the structure and the relationships between all EN 50600-x standards. EN 50600-2-1 Building Construction EN 50600-2-2 Power Distribution EN 50600-1 General Concepts EN 50600-2-3 Environmental Control EN 50600-2-4 Telecommunications Cabling Infrastructure EN 50600-2-5 Security Systems Figure 1: EN 50600-x structure EN 50600-3-1 Management & Operational Information www.commscope.com 3

Key advantages The EN 50600-x standard series has been developed by CENELEC (European Committee for Electrotechnical Standardization), an independent, non-profit European standardization organization. EN 50600-x is a European standard series that: Offers independent and comprehensive definitions & requirements for DC design and operation for all facilities & infrastructures Is commercially neutral without inherent assessment system Is internationally applicable for international DC owners/managers/operators by -- Replacing the European normative references with international counter parts -- Replacing European security standards by local counter parts Furthermore, the EN 50600-x: Offers as sole DC design standard an energy efficiency enablement approach that provides a basis for all energy efficiency KPI concepts, available or currently in development Gives guidance about the selection process for the required overall data center design parameters Provides design principles for DC designers and DC owners Defines non-profit oriented certification criteria In order to maintain and control the selected design as well as the energy efficiency criteria during operation, the supporting EN 50600-3-1 specifies processes for DC management and operations. Additionally, the modularity of the EN 50600 standard series enables the future integration of additional standards about management and operation resp. data center KPIs. www.commscope.com 4

Comparison with other standards/design concepts The following graphic has been developed in order to compare EN 50600-x with other standards in the data center environment including concepts from commercial assessors (for example the Uptime Institute, Data Center Alliance or TÜVIT): Scope 50600-X TIA-942-A ANSI/BICSI 002 Commercial assessors All DC facilities & infrastructures Cabling only All DC facilities & infrastructures Mainly power & environmental control European standard Regional application Europe/Internationally applicable by using ISO/IEC standards as United States United States International references Energy efficiency enablement Management & operation? Inclusion of global KPIs (ISO/IEC 30134-x)? Commercially neutral Independent assessment (Cabling only)? Business approach (design vs cost) Figure 2: EN 50600-x vs. other design standards/design concepts Key benefits per target group The availability of the EN 50600-x standard series is late in time compared to other standards or design concepts covering data centers. Nevertheless, EN 50600-x offers a lot of advantages to all parties involved in designing, building and operating data centers. The key advantages per interest group are: The DC Owner/Manager/Operator can use EN 50600-x series to translate business demands via risk assessment in terms of infrastructure availability vs. cost in order to: For DC Consultants, EN 50600-x series is a normative reference for the assessment of an appropriate DC design including defined design processes and design principles for all data center facilities and infrastructures. Architects & engineers get a suite of integrated standards for the design of data center facilities & infrastructures including defined design processes and design principles. Identify & select appropriate outline design requirements to provide the desired availability Apply concepts which are standards-based, business oriented and product/technology agnostic www.commscope.com 5

EN 50600-1: General concepts and availability classes EN 50600-1 describes the general concepts of the standard series and has the following scope: EN 50600-1: Details the issues to be addressed in a business risk and operating cost analysis enabling application of an appropriate classification of the data center Defines the common aspects of data centers including terminology, parameters and reference models (functional elements and their accommodation) addressing both the size and complexity of their intended purpose Describes general aspects of the facilities and infrastructures required to support effective operation of telecommunications within data centers Specifies a classification system, based upon the key criteria of availability, security and energy-efficiency over the planned lifetime of the data center, for the provision of effective facilities and infrastructure Describes the general design principles for data centers upon which the requirements of the EN 50600 series are based including symbols, labels, coding in drawings, quality assurance and education Furthermore, it functions as a base for all other standards of the series because their infrastructures have to be designed according to the chosen overall data center availability class, derived from EN 50600-1. The following graphic shows the main design criteria according to the chosen availability class for the infrastructures power distribution, environmental control and telecommunications cabling. Availability of overall set of facilities and infrastructures Low Medium High Very high Availability class Infrastructure 1 2 3 4 Power supply/distribution EN 50600-2-2 Single-path (no redundancy of components) Single-path (resilience provided by redundancy of components) Multi-path (resilience provided by redundancy of systems) Multi-path (fault tolerant even during maintenance) Environmental control EN 506000-2-3 No specific requirements Single-path (no redundancy of components) Single-path (resilience provided by redundancy of components) Multi-path (resilience provided by redundancy of systems). Allows maintenance during operation Telecommunications cabling EN 50600-2-4 Direct Connection or Single-path fixed infrastructure Single-path using fixed infrastructure with ENI-redundancy Multi-path using fixed infrastructure with ENI-redundancy and diverse pathways Multi-path using fixed infrastructure with ENI-redundancy, diverse pathways and redundant distribution areas Figure 3: Availability classes according EN 50600-1 The architectural and design requirements of the different availability classes for the telecommunications cabling infrastructure are subject of the next chapters of this document. www.commscope.com 6

EN 50600-2-4: Telecommunications cabling infrastructure Content and structure The telecommunications cabling within the data center serves to support the following: Data center information technology and network telecommunications Monitoring and controlling of other data center infrastructures Building management and automation Therefore, EN 50600-2-4 addresses the wide range of telecommunications cabling infrastructures within data centers based upon the criteria and classifications for availability within EN 50600-1. EN 50600-2-4 specifies requirements and recommendations for the following: The main focus when developing the EN 50600-2-4 was, in addition to the architectures and requirements for the availability classes, on migration and growth. The growth of IT capacity and the migration of applications towards higher speed are very dynamic in data centers. The cabling infrastructure of a data center has to be able to support these dynamics by enabling quick and easy extension of the data center (e.g. commissioning of additional equipment) and by offering migration paths for the network and storage applications used in the DC. EN 50600-2-4 supports migration and growth by defining appropriate requirements for cabling architectures, cross-connects and pathway systems. These requirements will be explained in the following chapters. Information technology and network telecommunications cabling (e.g. SAN and LAN) General information technology cabling to support the operation of the data center Telecommunications cabling to monitor and control, as appropriate, power distribution, environmental control and physical security of the data center Other building automation cabling Pathways, spaces and enclosures for the telecommunications cabling infrastructures The following graphic highlights the topics covered by EN 50600-2-4: EN 50600-2-4 Structured cabling for the DC operation (e.g. NOC) EN 50173-2 Cabling Types Point-To-Point Fixed Cabling Structured cabling for the IT function of the DC (e.g. networking and storage in the computer room) EN 50173-5 Cabling architectures and design requirements according the availability classes of EN 50600-1 Classes I-IV Structured cabling for monitoring & control of the building management & security functions of the DC Structured application specific cabling EN 50173-6 Requirements & recommendations for pathways and spaces Annex A: Cabling concepts Pathways, pathway systems, cable management systems, cabinets/racks/frames Figure 4: Content & structure of EN 50600-2-4 www.commscope.com 7

Cabling types Although EN 50600-2-4 is covering several types of cabling (see figure 4), it does not define any requirement for the structured cabling itself. It has not been created to supersede existing European cabling standards but it points to those for cabling definitions. The EN 50600-2-4 defines basically 2 cabling types: Point-to-point: Direct connection of two pieces of IT equipment using a dedicated cable rather than a generic cabling system. The point-to-point connection method uses discrete cords (typically factory-produced) that directly connect the active equipment. Fixed cabling: Structured cabling including the generic cabling solutions of the EN 50173 series between closures which have either peer-to-peer or hierarchical structure and which enables the installation of cross-connects or interconnects at those closures. Point-to-point cabling Although point-to-point cabling seems to be the simplest and most cost effective method of providing connections, for several reasons this cabling type should only be used for connections within the same or two adjacent cabinets, frames or racks. Point-to-point cabling is often not reusable as the data center evolves and equipment types and locations change and may have a limited life time expectation. Continuous changes to the required interconnections increase both the planning and the operational resources required for each change (see Figure 5 and Figure 6) and increases the risk of interfering with other infrastructures - including those for environmental control. Hence, it can be said that point-to-point cabling is not supporting migration and growth well. The following figures show the negative impact of using point-topoint cabling when the data center grows. Pre-change/addition Post-change/addition Server Storage Transparent devices are additions Switch Figure 5: Impact of growth in an unstructured point-to-point cabling infrastructure (Source: EN 50600-2-4) www.commscope.com 8

Figure 6: Example of unstructured growth of point-to-point cabling (Source: EN 50600-2-4) Fixed cabling A structured cabling system approach, illustrated in Figure 7, shows the equipment ports presented at remote central patching locations (CPLs). Server-to-storage connections are made using short, easily managed, cords within the CPL. The use of distributed zone patching locations (ZPL), connected to the CPLs with fixed cables provides additional flexibility for managing changes. Figure 7 shows how a fixed cabling implementation isolates the change activity to the defined areas. New equipment is connected to a CPL or ZPL without impacting active systems so no scheduled downtime is required. The equipment can then be connected to the active systems during the scheduled downtime by simply recon guring the cords at the CPL or ZPL. If a change causes a problem, it is only necessary to reconnect the cords into their pre-change configuration. The fixed cabling implementation enables more accurate predictions of the time required to implement system changes (and recovery) resulting in easier, faster changes that introduce less risk and enable improved overall system operation. A much better approach for the telecommunications cabling infrastructure in a data center is the usage of fixed cabling. Pre-change/addition Post-change/addition Central patching location Central patching location Server Zone patching location Zone patching location Storage Transparent devices are additions Switch Figure 7: Structured cabling infrastructure: setup and growth (Source: EN 50600-2-4) www.commscope.com 9

Availability classes and resulting cabling architectures Although EN 50600-2-4 defines several cabling types depending on the cabling use, this paper covers only the telecommunication cabling for the computer room space, the area of a data center where all function elements for the IT function of the data center are hosted. Data center space Cabling type Overall data center facilities & infrastructure - Availability Class 1 Overall data center facilities & infrastructure - Availability Class 2 Overall data center facilities & infrastructure - Availability Class 3 Overall data center facilities & infrastructure - Availability Class 4 Computer room space Inter-cabinets EN 50600-2-4 Class 1 EN 50600-2-4 Class 2 EN 50600-2-4 Class 3 EN 50600-2-4 Class 4 Intra-cabinets EN 50600-2-4 Class 1 EN 50600-2-4 Class 1 EN 50600-2-4 Class 1 EN 50600-2-4 Class 1 Adjacent cabinets EN 50600-2-4 Class 1 EN 50600-2-4 Class 1 EN 50600-2-4 Class 1 EN 50600-2-4 Class 1 Monitoring & control EN 50173-6 EN 50173-6 EN 50173-6 EN 50173-6 Office style cabling EN 50173-2 EN 50173-2 EN 50173-2 EN 50173-2 Control room space Office style cabling EN 50173-2 EN 50173-2 EN 50173-2 EN 50173-2 Monitoring & control EN 50173-6 EN 50173-6 EN 50173-6 EN 50173-6 Other spaces Office style cabling EN 50173-2 EN 50173-2 EN 50173-2 EN 50173-2 Monitoring & control EN 50173-6 EN 50173-6 EN 50173-6 EN 50173-6 Figure 8: Cabling requirements for different data center spaces and availability classes (Source: EN 50600-2-4) Basically, the telecommunications cabling in the computer room of a data center can be of 2 different kinds: Cabling within a cabinet (Intra-cabinet) or between 2 cabinets directly next to each other (adjacent-cabinet) Cabling between cabinets (Inter-Cabinet) These 2 computer room cabling types are defined for all four availability classes for the overall data center. While intra- and adjacent cabinet can always be designed according to class 1 (independent from the DC availability class), the inter-cabinet cabling in the computer room has to follow different cabling architectures according to the DC availability class as defined in figure 8. www.commscope.com 10

Cabling class 1 The telecommunications cabling infrastructure for Availability Class 1 uses either a point-to- point connection (i.e. equipment cords) for the transmission channel (see Figure 9) or a fixed cabling infrastructure in a single-path configuration according EN 50173-5 and a singletelecommunications provider scenario as shown in Figure 10. EQP C C EQP Direct attached equipment cord Figure 9: Telecommunications cabling class 1 using direct attached cords (Source: EN 50600-2-4) Telecommunications provider A Class 1 ENI MD ID ZD Figure 10: Telecommunications cabling class 1 using direct attached cords (Source: EN 50600-2-4) Cabling class 2 The telecommunications cabling infrastructure for Availability Class 2 shall use a fixed cabling infrastructure (e.g. according to EN 50173-5 or application-specific) in cabling subsystems defined in EN 50173-5 with a single-path architecture with redundancy on the ENI as shown in figure 11. Furthermore, all requirements of figure 14 shall be met. Telecommunications provider A Telecommunications provider B Class 2 ENI MD ID ZD Figure 11: Fixed Telecommunications cabling class 2 (Source: EN 50600-2-4) Legend C = Connection MD= Main Distribution ZD= Zone Distribution EQP= Equipment ID= Intermediate Distribution = Equipment Outlet ENI= External Network Interface www.commscope.com 11

Cabling class 3 The telecommunications cabling infrastructure for Availability Class 3 shall use a fixed cabling infrastructure (e.g. according to EN 50173-5 or application-specific) in cabling subsystems defined in EN 50173-5 with a multi-path redundancy configuration using diverse physical pathways as shown in Figure 12. Furthermore, all requirements of figure 14 shall be met. Telecommunications provider A Telecommunications provider B Class 3 ENI MD ID ZD ENI Pathway A Pathway B Telecommunications provider A Telecommunications provider B Figure 12: Fixed telecommunications cabling class 3 (Source: EN 50600-2-4) Cabling class 4 The telecommunications cabling infrastructure for Availability Class 4 shall use a fixed cabling infrastructure (e.g. according to EN 50173-5 or application-specific) in cabling subsystems defined in EN 50173-5 with a multi-path redundancy configuration using diverse physical pathways and redundant distribution areas as shown in Figure 13. Furthermore, all requirements of figure 14 shall be met. Telecommunications provider A Telecommunications provider B Class 4 ENI MD ID ZD ENI MD ID Telecommunications provider A Telecommunications provider B Figure 13: Fixed telecommunications cabling class 4 (Source: EN 50600-2-4) ZD Pathway A Pathway B Legend C = Connection EQP= Equipment ENI= External Network Interface MD= Main Distribution ZD= Zone Distribution ID= Intermediate Distribution = Equipment Outlet www.commscope.com 12

Specifications & requirements for the cabling classes The following figure summarizes all requirements for the computer room cabling classes. These requirements must be implemented in order to meet the selected availability class. Cabling class Cabling type Preferred installation Class 1 Direct attached or EN 50173-5 Configuration --Single-path --Single-pathway --Single-provider --Single-ENI Crossconnect Cross- connect features Pathway system Pathway system features Optional Optional - Class 2 EN 50173-5 or application specific --Single-path --Single-pathway Mandatory --Rear cable management --Side patch cord management Optional - --Multi-provider --Preferred: Cross-Connect cabinets/frames/ --Single-ENI racks > 800mm width Class 3 EN 50173-5 or application specific Pre-terminated --Multi-path --Diverse-pathway Mandatory --Rear cable management --Side patch cord management Mandatory --Sufficient capacity to cater for the defined maximum capacity level --Multi-provider --Bend radius control --Slack storage capabilities --Dual-ENI --Bend radius controlled slack storage --Bend radius control --Preferred:Cross-Connect cabinets/frames/ racks > 800mm width Class 4 EN 50173-5 or application specific Pre-terminated --Multi-path --Diverse-pathway Mandatory --Rear cable management --Side patch cord managment Mandatory --Sufficient capacity to cater for the defined maximum capacity level --Multi-provider --Bend radius control --Slack storage capabilities --Dual-ENI --Bend radius controlled slack storage --Bend radius control --Redundant --Preferred:Cross-Connect cabinets/frames/ distribution areas racks > 800mm width Figure 14: Cabling class requirement In order to allow quick moves, adds and changes, central and local patching/cross connect locations in MD, ID and ZD as shown in Figure 15: MD or ID acting as a CPL MD/ID Server ZD ZD Switch ZD acting as a ZPL Storage Figure 15: Moves, adds and changes using Cross-connects www.commscope.com 13

Using a Cross-Connect, for example, in the main distribution of a data center (as shown in figure 16) leads to transmission channels consisting of more than one cabling-subsystem, which demands the use of high performance cabling solutions capable of supporting any applications that are intended to be used. Additionally, the number of connections and the total length of the channel must be taken into account. Figure 16: Computer room cabling using cross-connects For the Classes 3 and 4, the use of pre-terminated cabling systems is preferred for the following reasons: On-site termination of cabling is impractical (e.g. field terminable connectors are not available) Operational constraints dictate that the time taken to install cabling shall be minimized (e.g.cabling needs to be in use as quickly as possible) Security concerns dictate that the presence in the data center of third-party labor is minimized. www.commscope.com 14

Requirements for cabinets, racks and frames In addition to the requirements for the cabling, the cross-connect cabinet and the pathways systems, EN 50600-2-4 defines also requirements for other cabinets, racks or frames in the computer room. General requirements Cabinets and racks must be selected to provide: A growth path for future technologies and data center capacity demands; Adequate cable management and bend radius functionality; Adequate ventilation and cooling for the equipment they will house (see EN 50600-2-3) Cabinets, racks and frames must be provided with cable and cord management fittings. Requirements for dimensions The minimum width of the cabinets/racks used for CPL and ZPL shall be 0.8 m with a preference for a larger width. Recommendations for overhead cabling The use of overhead telecommunications cabling is proven to improve cooling efficiency and is recommended where ceiling heights permit because it can substantially reduce airflow losses due to airflow obstruction and turbulence caused by under floor cabling and cabling pathways. Summary The EN 50600-2-4 is part of a new European standard series which is supposed to be the new Go-To-Standard for the design of DC facilities and infrastructures. It is mainly focused on supporting the overall DC availability class chosen from EN 50600-1 with the definition of appropriate cabling architectures. With a strong focus on application migration and growth, the EN 50600-2-4 favorites fixed cabling as the best choice for a data center. The mandatory use of cross-connects in MD, ID and ZD (cabling Classes 3 and 4) and the detailed specifications for these are based on best practices of the last 15 year of data center cabling design. Requirements and recommendations for cabinets/racks/frames, cable management and pathways systems complete a full set of cabling design specifications for state-of-the-art data centers. The minimum width of the cabinets/racks used for equipment must cope with the current and future cable management requirements. A width of 0.8 m is recommended. The minimum depth of the cabinets/racks used for equipment must cope with the current and future equipment dimensions. A depth of 1.2 m is recommended. Cabinets and racks must not be located under piping systems (both for reasons of breakage or aggregation of condensation), except piping systems used for cooling and fire extinguishing systems Recommendations for cable management The following cable management methods must be considered: 1. For low density systems, there should be one rack unit of horizontal cable management for each rack unit of termination points 2. For high density applications, horizontal cable management systems that required rack units should be replaced with cable management without rack unit usage 3. The capacity of the vertical cable management within cabinets should be twice the crosssectional area of the cables to be installed when the cabinets/racks are at full capacity 4. Cabinets may require additional depth or width to provide adequate vertical cable management 5. Blanking panels should be installed in unused cabinet positions in order to avoid mixing of hot and cold air www.commscope.com 15

Everyone communicates. It s the essence of the human experience. How we communicate is evolving. Technology is reshaping the way we live, learn and thrive. The epicenter of this transformation is the network our passion. Our experts are rethinking the purpose, role and usage of networks to help our customers increase bandwidth, expand capacity, enhance efficiency, speed deployment and simplify migration. From remote cell sites to massive sports arenas, from busy airports to state-of-the-art data centers we provide the essential expertise and vital infrastructure your business needs to succeed. The world s most advanced networks rely on CommScope connectivity. commscope.com Visit our website or contact your local CommScope representative for more information. 2017 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. CommScope is committed to the highest standards of business integrity and environmental sustainability, with a number of CommScope s facilities across the globe certified in accordance with international standards, including ISO 9001, TL 9000, and ISO 14001. Further information regarding CommScope s commitment can be found at www.commscope.com/about-us/corporate-responsibility-and-sustainability. WP-111201-EN (02/17)