LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to

Similar documents
LogicMachine5 Power (LM5p-DW1)

LogicMachine5 Reactor IO V2

LogicMachine5 Reactor GSM

Amati.linea Streaming Player light

CANx / LoRa 433 MHz 8 x Analog inputs / Digital ouputs

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application. Types of product. Standards and norms compliance.

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Manual and application description 4 channel 0-10V dimmer V2.0

Manual and application description KNX/EIB LED driver V2.0

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

User Manual. cmt-svr Startup Guide

ABB i-bus KNX AC/S Application Controller

IMIO100 IMIO105. DDC controllers. Summary

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

mark150s mark150/485s DDC controllers Summary

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Product and Applications Description

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

DomiOP ebis400 Series A new generation of Building HMI s. embedded building information system

User Manual. cmt-svr Startup Guide

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

EnerSure Installation Guide

Submittal Data Sheet WAGO Node for itm

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Lighting Control Panel

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

QUICK-START EMU M-BUS CENTER ENGLISH

Technical Manual MDT IP Router

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

KNX USB INTERFACE UIMtp

Technical Manual MDT IP Router

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2008A-4GSFP

Product and Application Description

with Backlight Graphic LCD Screen

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

HEC. General Operating, Maintenance and Installation Manual

Ethernet Interface Module

USER S MANUAL TP series

IntesisBox KNX - BACnet/IP Client

Operating and mounting instructions

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

584 5WG AB_1 DELTA

BACnet/IP Web Interface

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

Gateway configuration manual IP - KNX EK-BE1-TP

UR51 Industrial Cellular Router

Manual and Configuration. KNX PowerSupply 960. Enertex Bayern GmbH Ebermannstädter Straße Forchheim - Germany -

8~14-Port Managed Ethernet Switch


SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

Contents 1. Summary

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

USER MANUAL COMBOX.M - Modular energy management data concentrator

Short Instructions CG-S / IP-Router

Overview of the Cisco Wireless Gateway for LoRaWAN

5-Port Industrial Ethernet Switch - DIN Rail Mountable

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

efive 100 Installation Guide

RTU560 Remote Terminal Unit Connections and Settings

Technical Manual Nova: Cabinet Security Management System (CSMS)

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

IntesisBox Modbus Server KNX

ECLYPSE Communication Modules

IntesisBox KNX SAMSUNG NASA Air Conditioners

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

General Operating, Maintenance and Installation Manual

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

JUMO mtron T Measuring, Control, and Automation System

Connections, displays and operating elements C D

USER MANUAL FOR GS100/GS1003G

MU110-6U. Analog output module 6 channel. User guide

Remote I/O Product Specification

Multi-Point Gas Detection and Control System

ETHERNET/MFC 010 Technical Datasheet

Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature

Ethernet Network Card Installation and Operation Manual

ECLYPSE Communication Modules

RS485 MODBUS Module 8AO

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease.

Remote I/O Product Specification

Operating instructions Evaluation system for flow sensors VS / / 2013

Web interface BACnet/IP

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

BACnet/IP to BACnet MS/TP Router

IntesisBox Modbus Server - BACnet/IP Client

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

USER S MANUAL TP1043 series

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Transcription:

Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com LogicMachine5 LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire networks. LM will enable you to efficiently customize building automation processes, easily delivering unlimited flexibility benefit to end users in a cost-effective way. LM is an embedded platform with integrated Ethernet, USB, DALI, 1-Wire, KNX/EIB, Serial interfaces. LM allows to use it as cross-standard gateway, logic engine, visualization platform, IP Router. Scripting templates provides userfriendly, flexible configuration interface. Via applying custom scripts LM can simultaneously act as thermostat, security panel, lighting controller, etc. In comparison with former LM versions, LM5 has built-in configurable termination resistors for RS-485 ports, 24V DC output with voltage and current monitoring possibility and Power-over-Ethernet support. Further, LM5 is 3x more powerful than all previous LogicMachine versions due to more powerful CPU and RAM. ENG - Data sheet Issue date 11.05.2016 1

Application Logical functions; WEB SCADA visualization for PC and touch-devices; cross-standard gateway; integration with third party devices over USB and RS485 serial port AV, IR, HVAC; Data logger with trends, KNX IP Router etc. 2

Types of product LogiMachine5 LM5 Standards and norms compliance EMC: PCT EN61000-6-1 EN61000-6-3 Certificate Technical data: Power supply: Power consummation: 1.3W 24V DC on terminal connectors or 24V DC Power-over-Ethernet Interface: KNX/EIB TP1 1 10BaseT/100BaseTX 1 RS-485 with termination resistors 2 USB2.0 1 DALI 1 1-Wire 1 24V OUT for voltage and current measurement, max 1 A Connections: KNX bus: Bus Connection Terminal 0.8mm2 Power supply: Screw, 1.5mm2 Serial: Screw, 1.5mm2 DALI: Screw, 1.5mm2 1-Wire: Screw, 1.5mm2 Operating elements LED 1 CPU load 1 - Activity Enclosure: Material: Polyamide Color: Gray Dimensions: 70(W)x90(H)x61(L) mm Usage temperature: 0C... +45C Storage temperature: -15C... +55C Weight: 150g Warranty: 2 years Relative Humidity: 10...95 % without condensation 3

Caution Security advice The installation and assembly of electrical equipment may only be performed by skilled electrician. The devices must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with application that can result danger of people, animals or real value Mounting advice The devices are supplied in operational status. The cables connections included can be clamped to the housing if required. Electrical connection The devices are constructed for the operation of protective low voltage (SELV). Grounding of device is not needed. When switching the power supply on or off, power surges must be avoided. 4

Terminal connection schemes KNX Choke interconnection with LM5 This setup allows to monitor voltage and current usage of KNX fieldbus. 5

DALI connection 6

RS-485 connection 1-wire connection 7

Power over Ethernet To use passive PoE powering over 24V DC, you have to make sure both jumpers are set to the right position as shown in the picture below (they are by default set to this mode). You need to open the device enclosure to change jumper settings. Please note that in PoE jumper mode the device can be powered both over PoE as well as regular 24V screw terminals. 8

Quick startup guide 1) Mounting the device on DIN rail 2) Connect the KNX bus cable 3) Connect 24V power supply to the device (either through separate 24V crew terminals or through Passive 24V DC Power-Over-Ethernet 4) Connect Ethernet/LAN cable coming from the PC Default IP configuration Login name admin Password admin IP address 192.168.0.10 Network mask 255.255.255.0 Reset device You can either reboot the device by pressing RESET button or reset the configuration to factory defaults: Press and hold for <10 sec reboot the device Press and hold for >10 sec reset networking with IP to factory default Press and hold for >10 sec and again press and hold for >10 sec full reset of configuration to factory defaults 9