FA-2448 SIX POSITION Filter Wheel

Similar documents
Acton Research Corporation Model VM Meter Triple Grating Vacuum Monochromator Operating Instructions

AB300-Series Automated Filter Wheels

30 Watt Deuterium / Tungsten Dual Light Source / Model TDS-429 Operating Manual

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

I/O SIGNAL CONDITIONER

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY

U-232 USB based Serial Port replacement Version 2.0 Revision

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Proliphix EPA-60 Installation Guide

Resolver to Digital Expansion Board

MODBUS MANUAL For the AccUView UV Transmission Monitor

Enhanced Mini-Chansim Model VCS-232

Global Water Instrumentation, Inc.

Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Installation and Operation Manual

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Sonic Ruptor 400. User Manual

PMDX-170 Slotted Optical Sensor

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

MODEL 715AN QUADRATURE DEGREES COUNTER

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

AEXX-349 SERIES REMOTE DISPLAYS

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

DBR Laser Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Series CTA CAP TORQUE TESTERS. User s Guide

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

MAXIMA+ Series Rotary Level Indicator

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

Global Water Instrumentation, Inc.

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

User s Guide. Series CT CLOSURE TORQUE TESTER. User s Guide

MODEL P104-COM232-8 USER MANUAL

Installation & Operation

FNet Repeater Installation & Operator s Instruction Manual

SOLVES-IT! 4 CHANNEL TIMER APPLICATION MODULE

ADAM Fiber Optic to RS-232/422/485 Converter

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

Installation & Operation Manual Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

RS422 PORT SWITCHER REMOTE CONTROL PANEL

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1

Automated Tuner System Power Distribution Hub

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

MPP200 User s Manual

21 TRACK MAINTENANCE GUIDE

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

MPT-250A SPECIFICATIONS AND OPERATING INSTRUCTIONS

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

AL Dot User guide

VADDIO /CANON BU-SERIES PTZ CAMERAS

OPERATING AND SERVICE MANUAL. Universal Interface Device 45

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

User s Guide. POWERVAR Single Phase Power Conditioners

ANC Series RS-422 Serial Communications Adapter

Installation & Operation Instructions

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

CMSA-100 Manual. Cinema Media Server Automation

TSD-DA28 2x8 Balanced Line Distribution Amplifier

COBEX RECORDERS, INC.

KBMG MULTI-SPEED BOARD

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Hybrid AC Driver [GCNC-1110]

Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

WR-5e Remote Control

Getting started with your DGH module:

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

Ashly WR-5 Remote Control

Elapsed Timer Control Panel

PC 150. Digital Bench Scale. Operation Manual

Pit Transition with 24" Fan Installation and Operators Instruction Manual

Economy Single Channel Output DC Power Supply

Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25

PIM-Mini Pulsed Current Source Operation Manual

Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

ACLD Channel Opto-isolated Digital Input Board

INSTALLATION & OPERATING INSTRUCTIONS

1550 MBS. User Manual. Modbus Protocol Interface Communications Interface for 1336 Adjustable Frequency AC Drive

Install Motor Controller User Manual

MODEL No. SW1X8 RS422 SWITCHER

FTC-200 X-ray Tube Controller Users Manual

6001TA Terminal Adapter Installation Instructions

Transcription:

15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17

Contents I. Description II. III. Specifications Installation A. Mounting to Monochromator B. Connecting Control Unit C. Installing and Changing Filters IV. Operation A. Operation from Controller Unit B. Operation with RS-232 or USB V. Figures VI. VII. Appendix A: Connector Wiring Warranty

I. Description The FA-2448 is a series of filter wheel assemblies which are available with and without installed order sorting filters and with and without remote position control. This manual covers the following models: FA-2448 FA-2448-1 FA-2448-2 FA-2448-3 FA-2448-4 Six position filter wheel. Manual sample indexing or operation with SP-2000 series monochromators. Holds 6 samples or filters, each 1 inch diameter. Does not include filters. Order sorting filter assembly. Manual sample indexing or operation with SP-2000 series monochromators. 320nm, 590nm, 665nm, and 715nm order sorting filters mounted in the FA-2448 filter wheel assembly. Motorized six position filter wheel with stepping motor and FA-2448-4 controller. Enables computer controlled filter indexing through RS-232 and USB ports. Does not include filters. Requires computer or terminal with RS-232 or USB port for external control. Motorized order sorting filter assembly. Same as FA-2448-2, except with order sorting filters installed. Controller retrofit unit. For use with FA-2448 and FA-2448-1 manual filter assemblies to allow computer control through USB or RS-232. * Positions of order sorting filters in FA-2448-1 and FA-2448-3: Position 1: Open Position 2: 320nm cut-off filter Position 3: 590nm cut-off filter Position 4: 665nm cut-off filter Position 5: 715nm cut-off filter

II. FA-2448 Series Filter Assembly Specifications Six position wheel One inch (1" ±0.005) diameter filters, maximum thickness =0.200" Controller specifications: Control from computer or terminal through USB or RS-232 port at 9600 baud, no parity, 8 data bits, 1 stop bit and 1 start bit. Time required for filter change = 2.5 seconds for adjacent filter positions.

III. Installation A. Mounting to Monochromator The filter assembly is 3/4 of an inch thick. Therefore, if using a light source that is designed to mount directly on the entrance slit housing and to focus the light on the entrance slit, it is recommended that the filter assembly be mounted on the exit slit housing. If it is necessary to install or change filters, do so before mounting the filter wheel to the SpectraPro (refer to step C). The filter assembly is designed to mount directly to the SpectraPro slit housings or to be mounted between the light source or detector and the slit housing. The filter assembly is attached to the slit housing with three screws. The fourth screw is not used with the filter assembly. Assure that the (3) 8-32 mounting screws extend approximately 0.25 inch (6mm) beyond the filter assembly housing. Orient the filter assembly so that the aperture slot is vertical and the motor is away from the instrument housing. Mount the filter assembly or light source/detector to the desired slit housing with (3) 8-32 screws. B. Connecting Control Unit A power supply is provided with each control unit which must be connected to 100-250 VAC and the control unit. Attach the supplied 15 pin connector cable to the control unit and the filter wheel assembly. For computer operation of the filter assemblies, each control unit must be connected to separate RS-232 ports of a computer or terminal or a computer USB port or hub. Acton Research Corporation offers the following connecting cables: CC-499-2 Cable for IBM-PC/AT or compatible computer, 9 pin female connector to 9 pin male connector (standard) 3650-USB-06 USB cable Type A to Type B (optional) If none of the above cable assemblies are compatible with your computer or terminal, contact Acton Research Corporation for a custom cable or one may be constructed using a standard DE-9P connector at the filter controller end with the following connections: pin # description 1 open 2 RD received data to the computer 3 TD transmitted data from the computer 4 open 5 ground 6 open 7 open 8 open 9 open

POWER USB HUB USB RS-232 READY COM FILTER Power connection +5 and +24 Volts USB Hub 1.1 compatible. USB connection to computer. RS-232 connection to computer. Ready light is on when power is on. (Light comes on after the Filter Wheel initializes.) Com light flashes when communicating with the computer. Filter driver connection for ARC FA-2448 Filter Wheel.

C. Installing and Changing Filters To install or remove filters or samples, the following procedure is recommended: 1) If the filter assembly is mounted to the SpectraPro, remove it and disconnect the cable, if attached. 2) Place the filter assembly on a clean surface with the motor down. Refer to Figure 1. 3) Using the 1/16" allen wrench supplied, remove the eight screws securing the cover plate to the filter assembly (refer to Figure 1). While pushing on the end of the shaft with a pencil, carefully remove the cover plate by lifting straight off the shaft. Caution: A spacer is located on the filter wheel shaft between the filter wheel and cover. If this spacer comes off with the cover, place it back onto the shaft. Refer to Figure 2. 4) The six filter positions are now visible, refer to Figure 2. The filters are held in with split rings. Determine the filters to be removed or the location for the filters to be installed. The filter positions are marked 1 thru 6 on the wheel. Remove the split rings. Remove or install filters as required. Replace the split ring assuring it is pushed firmly against the filters. 5) Assure that the spacer is on the filter wheel shaft and attach the cover plate with the eight screws. The filter assembly is now ready for mounting to the SpectraPro.

IV. Operation A. Operation from Controller Unit Connect the motor drive cable from the filter wheel to the filter wheel controller. Connect the controller to the power supply and the power supply to an AC line of the voltage listed on the back of the power supply. Assure the detent screw is backed away from the filter wheel when using motor control. (The filter positions of each filter wheel can be controlled manually using the knob on the filter wheel motor when the detent screw engages the filter wheel.) B. Operation with RS-232 or USB Connect the controller to a computer with either the RS-232 output or the USB output. See section III-B for cable installation instructions. Windows compatible filter control software is provided on the enclosed CD. For RS-232 operation, the port set-up is 9600 baud, 8 data bits, 1 stop bit and no parity. All commands or strings of commands must be terminated with a carriage return (0D hex). The control unit responds to a command when the command has been completed by returning the characters OK followed by a carriage return and line feed (hex ASCII sequence 20 6F 0D 0A). The default condition is to echo each character that is sent to the control unit. If no echo is desired, the command NO-ECHO will suppress the echo. The command ECHO will return the controller to the default echo state. The filter wheel with controller responds to commands from the computer or terminal in the form of ASCII strings. The following commands are used for controlling the filter position: FILTER?FILTER FHOME Controls the filter position and is used as follows: 3 FILTER <enter> sets filter wheel to position 3. Filter positions 1-6 may be selected. Note that there must be a space after the number and the command must be terminated with the enter or carriage return key. The filter will go to the specified position in the direction which requires the shortest move. Returns the current filter position. Typing?FILTER <enter> will cause the current filter position to be returned to the computer and displayed. Initializes the filter wheel to the first filter position. This command is automatically executed at power-up. The filter wheel controller keeps track of filter position as long as power is applied. It should not be necessary to execute this command under normal circumstances, although it is available if desired. This command follows the same format as in FILTER above for entry and response.

V. Figures

VI. Appendix A: Connector Wiring Filter Wheel Drive Cable J1 Filter Wheel Pin # 1 Motor phase 1A 2 Motor phase 1C 3 Motor phase 1B 4 open 5 Motor phase 2A 6 Motor phase 2C 7 Motor phase 2B 8 open 9 open 10 Interrupter module OUT 11 Interrupter module GND 12 Interrupter module LED cathode 13 Interrupter module LED anode 14 Interrupter module +5vdc 15 Shield NOTES: The filter connector type is D-15S. The controller connector type is HD-15P. 2. Pins 8 and 13 are connected inside the controller connector housing. 3. Cable is 24 AWG with overall shield.

VII. Warranty Certification Acton Research Corporation (ARC) certifies that this instrument was thoroughly tested and inspected and found to meet the specifications furnished by ARC when it was shipped from the factory. Warranty Acton Research Corporation (ARC) instruments and accessories are warranted for a period of one full year from date of delivery to be free from defects in material and workmanship and to conforms to the specifications furnished by ARC. The corporation's obligation under this warranty is limited to servicing or adjusting an instrument returned to the factory, prepaid, and to repairing or replacing at the factory any part or parts thereof. All purchased items carry the original manufacturers guarantee. Acton Research Corporation shall not be liable for consequential damages resulting from accident, alteration, misuse, improper installation, operation on low or excessive voltages or any use in violation of the operating instructions furnished by ARC. If any defect appears within the warranty period, the purchaser shall promptly notify ARC. No material will be accepted for repair or replacement without prior authorization from ARC. Upon such authorization and in accordance with instructions of Acton Research Corporation, parts, materials or equipment for which repair or replacement is requested shall be returned to ARC for examination, with shipping charges prepaid by the purchaser. Final determination as to whether a product or part is actually defective rests with Acton Research Corporation. In such cases where necessary repairs are not covered by this warranty, an estimate of repair charges will be submitted to the purchaser before servicing the equipment. Acton Research Corporation reserves the right to make changes or improvements upon its products without imposing any obligations upon itself to install the same upon its products previously manufactured. This warranty is expressly in lieu of all other obligations or liabilities on the part of ARC, and ARC neither assumes, nor authorizes any other person to assume for them, other obligations or liability in connection with the sale of equipment manufactured by Acton Research Corporation.