Library for Building Automation. Module Descriptions for KNX IP Master

Similar documents
WAGO Remote IO with Fanuc Robot using EtherNet/IP Protocol Application note

Redundant ethernet communication with WAGO Ethernet-Controller Application note

Configuring National Instruments Lab View with WAGO I/O Application note

Libraries for Building Automation. Function Blocks and Data Types for the BACnet Controller

Application note. WAGO-I/O-SYSTEM 750 DALI Multi-Master Module Configuration of a DALI Lighting System via WAGO- I/O-PRO V2.

Libraries for Building Automation. Module Descriptions for the WINSTA Sunblind Box /

Using WAGO Series 750 DeviceNet IO with an A-B SLC SDN Scanner Application note

Using WAGO Series 750 DeviceNet IO with an A-B ControlLogix 1756-DNB Scanner Application note

Using the WAGO as Remote I/O with an Omron SYSMAC CJ2 Series PLC. Application note. A116700, English Version 1.1.0

Fieldbus Independent I/O Modules Bluetooth RF Transceiver Quick Start

Application Note. Building. Automation WAGO-I/O-PRO V2.3. openvpn with Linux based Devices A500880_en. Version 1.1.1

Application Note. WAGO-I/O-SYSTEM 750 Connecting energy meters with M-Bus interface to the WAGO-I/O-SYSTEM

Using WAGO Series 750 EtherCAT coupler with CoDeSys SP Win V3 Application note

Using the WAGO as Remote I/O with a ControlLogix Ethernet/IP Bridge Module Application note

Library Description. KNX_02.lib. CODESYS V2.3 Function Block for the KNX/EIB/TP1 Module

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

WAGO-I/O-SYSTEM 750 CODESYS-2-Library WagoLibWakeOnLan.lib Wake on lan Remote wake up of network devices

Library for Building Automation

Library for Building Automation. Function block descriptions for time- switching functions

Fieldbus Independent I/O Modules End Module (/xxx-xxx) Manual

Using the WagoAppEtherNetIP_Adapter library with a CompactLogix Controller A500930

Fieldbus Independent I/O Modules SSI Transmitter Interface Manual

Fieldbus Independent I/O Modules Field Side Connection Manual

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

The HART Module on the WAGO ETHERNET Controller Application Note

Application Note. Enable port forwarding for PFC. A500840, English Version 1.0.0

Fieldbus Independent I/O Modules 4 AI DC 0-10 V, Single-Ended Manual

Fieldbus Independent I/O Modules 1 AI DMS Manual

Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual

Fieldbus Independent I/O Modules 24 V DC Power Supply/Fuse/Diagn Manual

Fieldbus Independent I/O Modules 4 DO DC 24 V 0.5 A, High-Side Switching (/xxx-xxx)

WagoLib_CAN_Gateway_02.lib

Libraries for Building Automation. Function Block Description for DALI Multi-Master Module

Library for Building Automation. Library Description for for the WAGO BACnet Library BACnet_02.lib

Fieldbus Independent I/O Modules 2 AO 4-20 ma Manual

Application Note. a HART Tool-routing with Emerson AMS HART over TH LINK PROFIBUS for Asset Management 1.0.0

Library Description. DALI_647_SpecialSensor_02.lib Specific Sensor Solutions. Version 1.0.1

Application Note. Connection of an WAGO ETHERNET Coupler/Controller to a S controller

Using PROFIsafe modules in combination with PROFIBUS-DP and PROFINET Application note

Library Description. MBUS_649_01.lib WAGO M-Bus Library. Version 1.0.1

PROFIsafe modules V2 ipar 75x-66x/ WAGO Safety-Editor-75x Quickstart

Using power measurement module with TIA A500671

Manual Version WAGO TO-PASS 761. Telecontrol Modules. 761-xxx. System Description

Libraries for Building Automation

Fieldbus Independent I/O Modules Serial Interface RS 232 C (/xxx-xxx) Manual

WAGO-I/O-SYSTEM 750 IO-Link Master

WAGO-I/O-SYSTEM 750 IO-Link Master

Modbus/TCP OPC Server

Library Description. ColourConverter_01.lib Library for Converting Color Formats. Version 1.0.2

Library for Building Automation. Function Block Description for M-Bus

Manual. PLC Lib: Tc2_DMX. TwinCAT 3. Version: Date:

Embedded Linux Automation for the Future

Instruction Manual. VISAM TouchPanel VTP-AX 328. A product of the. VBASE - HMI/SCADA family. Document: HB_VTPAX_328_v1.0e_FINAL.

Library Description. Enocean_06.lib WAGO EnOcean Profile Library. Version 1.0.1

Manual. PLC Lib: Tc2_SMI. TwinCAT 3. Version: Date:

Manual. TC3 Power Monitoring. TwinCAT 3. Version: Date: Order No.: TF3650

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

THE KNX IP CONTROLLER. Taking Proven Technology to the Next Level

Manual. TwinCAT MC Flying Saw. TwinCAT 3. Version: Date: Order No.: TF5055

Manual. PLC Lib: Tc2_DataExchange. TwinCAT 3. Version: Date:

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 (

Manual. PLC Lib: Tc2_DataExchange. TwinCAT 3. Version: Date:

YJKP with Mitsubishi Q series PLC control via Modbus TCP

User Manual Connection to BRC-Symbolic

Library Description. Building WAGO-I/O- PRO V2.3. Automation. MpBus_03.lib CODESYS V2.3 Module for MP-Bus. Version 1.0.1

Quickstart reference for the software e!cockpit

The WAGO BACnet Configurator

Application Note. Modbus on CMMP-AS- -M3/M0. Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network.

Manual. PLC Lib: Tc2_Drive. TwinCAT 3. Version: Date:

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

Brief instructions WAGO TOPLON for TOPLON IF und TOPLON PRIO

Embedded Linux Open Automation for the Future

Library for Building Automation. Function Block Descriptions Common Building Functions

CPX-FB36 in Ethernet/IP Mode

TC3 Interface for Matlab /Simulink

Manual. PLC Lib: Tc2_EtherCAT. TwinCAT 3. Version: Date:

LINK LINK MS NS USR SD. From the Field Level up to the Cloud WAGO Cloud Connectivity and WAGO Cloud Data Control

Modbus RTU Protocol description

Replacement of MS6-SV-1/2-E-ASIS-

WAGO-I/O-IPC. Maximum Processing Power in Minimal Space

LED CONNECTION TECHNOLOGY. For LED Modules and Lighting

WAGO MARKING. Samples and Overview

Application Note Commissioning VTEM connected to Beckoff PLC via CPX-FB38 bus node

Manual. TC3 EtherCAT Simulation. TwinCAT 3. Version: Date: Order No.: TE1111

TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability

Safety I/O Modules PROFIsafe 4FDO 0,5A/4FDI 24V DC PROFIsafe / Manual

WAGO Energy Data Management Efficiency Is That Easy!

Manual / Electronic Circuit Breaker DC 24 V, A. Version 1.0.0

Industrial-Automation System HIMatrix. MODBUS Master/Slave. Manual

Manual. PLC Lib: Tc2_Coupler. TwinCAT 3. Version: Date:

Controllers Open Flexible Compact

CECC-LK as IO-Link Master connected to Balluff RFID Device and data carriers

SMD Terminal Blocks Small is Big

TOPJOB S Rail-Mounted Terminal Blocks with the Reliability of Push-in CAGE CLAMP

Manual. PLC Lib: Tc2_Standard. TwinCAT 3. Version: Date:

APPLICATION SUPPORT. The fast way to the first automation project with. VBASE-Editor version 11 or higher

New Product Highlights. Issue 1/2014

New Product Highlights. Issue 1/2014

HE-65 CAN-BUS. (DeviceNet-Slave) Technical Information TR - ECE - TI - GB /30/2016

Transcription:

Library for Building Automation Module Descriptions for KNX IP Master Last Update: 28.01.2008

Copyright 2007 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: info@wago.com Web: http://www.wago.com Technical Support Tel.: +49 (0) 571/8 87 777 Fax: +49 (0) 571/8 87 8777 E-Mail: tcba@wago.com Every conceivable measure has been taken to ensure the correctness and completeness of this documentation. However, as errors can never be fully excluded, we would appreciate any information or ideas at any time. We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally protected by trademark or patent. 2

Contents WAGO-I/O-PRO CAA Library for KNX Communication Contents Important Notes 4 Copyright...4 Personnel Qualification...4 Intended Use...4 Scope of Validity...5 Modules 6 KNX Master Controller 750-849...6 3

Important Notes Important Notes To ensure fast installation and start-up of the units, we strongly recommend that the following information and explanations are carefully read and adhered to. Copyright This document including all figures and illustrations contained therein is subject to copyright. Any use of this document which infringes the copyright provisions stipulated herein, is not permitted. Reproduction, translation and any electronic and photographic archiving and amendments require the written consent of WAGO Kontakttechnick GmbH & Co. KG, Minden. Non-observance will entail the right of claims for damages. WAGO Kontakttechnik GmbH & Co. KG reserves the right of changes serving technical progress. All rights developing from the issue of a patent or the legal protection of utility patents are reserved to WAGO Kontakttechnik GmbH & Co. KG. Third-party products are always indicated without any notes concerning patent rights. Personnel Qualification Intended Use The use of the product detailed in this document is exclusively geared to specialists having qualifications in PLC programming, electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards. WAGO Kontakttechnik GmbH & Co. KG declines any liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this document. For each individual application, the components are supplied from the factory with a dedicated hardware and software configuration. Modifications are only admitted within the framework of the possibilities documented in the manuals. All other changes to the hardware and/or software and the non-conforming use of the components entail the exclusion of liability on the part of WAGO Kontakttechnik GmbH & Co. KG. Please direct any requirements pertaining to a modified and/or new hardware or software configuration directly to WAGO Kontakttechnik GmbH & Co. KG. 4

Important Notes Scope of Validity This application note is based on the stated hardware and software of the specific manufacturer as well as the correspondent documentation. This application note is therefore only valid for the described installation. New hardware and software versions may need to be handled differently. Please note the detailed description in the specific manuals. 5

Modules KNX Master Controller 750-849 WAGO-I/O-PRO CAA Library Elements Category: Building Services Name: FbKNX_Master_849 Type: Function Function block X Program Name of library: KNX_IP_750_849_01.lib Applicable to: 750-849 Libraries used: SysLibGetAddress.lib WAGOLibKNXDevice.lib KNX_Standard.lib Input / output parameters Data type: Comment: typknx typknx KNX transmit and receive data (internal). dwcrc DWORD Checksum via addresses. bhw_type BYTE Display of modules/controller master. berror BYTE Error byte. typmodule_646 typmodule _646 Data table for communication with other KNX function blocks.bnumber.bcurrent_pos.dwsendaddr.dwreceaddr..xbusy.xnewdata.xsendonreset.xsyncready.bbytestosend.ardata_out.ardata_in BYTE BYTE DWORD DWORD BOOL BOOL BOOL BOOL BYTE ARRAY ARRAY Number of linked slave modules Number of slave currently being queried Reference address for DPT variable to be sent Address of DPT variables being received Master is busy Flag of new data from module Initiate SendOnReset Synchronization completed Number of bytes to be sent Data array for output user data Data array for input user data

Modules Output parameters: Data type: Comment: enumdevicestatus enumdevi Output of status information cestatus KNX_DEVICE_NOT_INIT KNX_DEVICE_OK KNX_APP_NOT_RUNNING KNX_APPLICATION_LOADED KNX_APPLICATION_START_LOADI NG KNX_APPL_CRC_OK KNX_APPL_CRC_ERR KNX_APPL_SYS_ERR KNX_DEVICE_KBUS_ERROR KNX_DEVICE_ETHERNET_ERROR xprog_mode BOOL Module in programming mode Illustration: Function description: The FbKNX_Master_849 function block is used for communication with the KNX IP Controller 750-849. The function block detects information of the other KNX function blocks in the program and provides synchronization with the controller. The information from the KNX function blocks are provided in the form of data table via the typknx variable. The function block must only be used once for each KNX controller 750-849. All other KNX function blocks must be linked with this function block via the input variable "typknx". The output variable "enumdevicestatus" transmits status information via the KNX controller. The output "xprog_mode indicates whether the KNX controller is in the programming mode. Important: All KNX function blocks that are linked by the variable "typknx" must be called up in cycles within the same program task. 7

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 71/8 87 0 Fax: 05 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com