ECM-1220 User s Manual

Similar documents
ECM-1240 User Manual

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

DPM Digital DC Power Meter with Data logging capability. User Manual

GreenEye Monitor. Introducing AVAILABLE IN TWO VERSIONS: FEATURES. Residential Single/Split Phase Systems. Three Phase commercial, light industrial

SOLARIMMERSION IV Advanced Installation Manual v1.9

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Digital Photo Frame With Alarm Clock Model DPF-363

DPM-3221 Digital DC Power Meter with data logging capability.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

IIM Warwick Court. Williamsburg VA REV 5

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Basic Setup for the Current Probes Input Option

Panduit Basic Rack PDU with Local Meter

Quick Start Installation and User Manual

GreenEye Monitor Specifications

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide

GreenEye/DashBox System. Installation Manual

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

High Precision Quad Output DC Power Supply

MENU BUTTON FULL OPERATORS MANUAL FOR POWER-MATE LITE QUICK START MANUAL BEGINS ON PAGE 5 OVERVIEW GENERAL PRECAUTIONS BEFORE USING THE PML

PM Series Power Meter

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Billion SG3015. Compact ZigBee Power Meter Series. Fully complied with IEEE

AutoRanging Digital MultiMeter

Model A Mini AC/DC Clamp Meter. User's Guide

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

AMP20. User Manual.

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

SubCast Transmitter/Receiver Subwoofer Kit

Mini Digital Multimeter

ECM-1240 Energy Consumption Monitor

Instruction manual Wattmeter CLM1000 Home

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

BRAND ELECTRONICS DIGITAL POWER METER MODEL

Mini Digital Multimeter

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

INSTRUCTION/INSTALLATION SHEET lyriq High Performance Keypad Volume Control With IR

3700 SERIES USER MANUAL

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

PowerLogic TM Series EM4800 Multi-Circuit Meters. Configuration Guide

OPERATING INSTRUCTION

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

PA39085 INSTRUCTION MANUAL

/21 CLAMP ON POWER

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

SAVE THESE INSTRUCTIONS

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B

i-meter EM Series & i-meter MF Series Installation and User Manual

Autoranging True RMS Multimeter User Manual

MIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

EMS Electrical Management System

User Guide True RMS Multimeter Extech EX205T

Installation Instructions

Series 3000 User Manual and Product Features

700 Series 200 Amp Clamp Meters

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

Power Analyzer Datalogger Model

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Mini Digital Multimeter Model MN15. User's Guide

HBAC-30. Owner s Manual. Battery powered Guitar Amp

EMS Electrical Management System

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Instruction manual Wattmeter CLM1000 Standard

Why is my AFCI tripping?

SureTest Model ST 1D Instructions

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

3-Phase Power Analyzer/Datalogger

User's Guide. Model High Precision Quad Output DC Power Supply

Smart Monitor User Manual

Barefoot Power Ltd 2013 v1.4

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

EnerSure Installation Guide

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

INSTEON SwitchLinc 1000W. INSTEON Dimmer Switch. For models: SwitchLinc V2 Dimmer 1000W

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

EATON 5S 850/1200/1600

User Manual. Thank you for purchasing the Electricity Usage Monitor by Poniie. Please

INSTRUCTION MANUAL DIGITAL POWER METER KEW Kyoritsu Electrical Instruments Works, Ltd.

PRE116/126. User Manual.

FIBARO SINGLE SWITCH

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # Series Power Analyzer Model 806 Instruction Manual

Panduit Basic Rack PDU

Technical Specificaions. kwh Energy Meter

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

ReCon T Energy Logger

Universal AC Power Source + AC Power Analyzer

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Transcription:

1 ECM-1220 User s Manual Table of Contents ECM-1220 User s Manual...1 Table of Contents...1 Introduction / How It Works...2 Safety...4 Quick Start...5 Verifying / Changing Settings...6 Installation...8 Viewing Information...12 Firmware Upgrade...13 Specifications...15

2 Introduction / How It Works The ECM-1220 Monitor / Logger is a two channel power meter. It tracks and records the true (real) power consumed by an electrical load. The term load represents an appliance, a machine, a lighting circuit, or any electrical device which consumes electrical power. In order to derive true power a power meter requires real time access of two parameters: 1. The voltage (Volt) supplied to the load. 2. The current (Amperes) flowing through the load. In order to access these parameters from a powered load, the ECM-1220 uses the most non-intrusive and safe method of doing this: 1. The ECM-1220 reads the line voltage (120V household voltage) via the supplied AC wall transformer (usually termed AC adaptor). The low voltage secondary AC signal from the wall transformer is proportional to the line voltage. With this technique, there is no need to connect to dangerous voltage levels. When a transformer is used in this way, it is termed Potential Transformer (PT). 2. In order to access the load s current without splicing into a current carrying conductor, the ECM-1220 uses a Current Transformer (CT). The CT simply clamps around one conductor supplying the load. (The CT cannot be clamped around a power cord to the load since the two current carrying conductors inside the cable are of opposite polarities and the magnetic fields cancel out.) The technique described above not only makes the ECM-1220 safer to install, but also provides versatility in the types of loads which can be monitored and its applications. Since the monitor obtains the required parameters indirectly, it is important for the ECM-1220 to know the value of the wall transformer s (PT s) ratio of primary to secondary voltage. The ECM-1220 also requires the CT s ratio for an accurate representation of the current. These values are labelled on the PT and CT. It is very important to verify that your ECM-1220 is set to these values. Once this is done, the ECM-1220 will always remember these values until they are manually altered. In other words, this only needs to be setup once, unless the CT is substituted with another type for higher current applications.

3 Once the ECM-1220 is setup and monitoring a load, the energy consumption may be monitored and recorded in several ways: 1. The non-volatile incrementing counter which display the kwh value, much like a residential power meter. This counter keeps incrementing (with power usage) until the user decides to reset it. 2. The ECM-1220 also has internal memory for data logging. The data logging records and saves power consumption data at a regular interval. This interval setting is selected by the user. Although the data is saved at periodic intervals, this data represents and average of continuous sampling (several hundred samples per second). This feature is available with the download option only. 3. The other method of monitoring is to have the ECM-1220 connected to a computer via USB cable or wirelessly via optional Bluetooth. With this method, data can be collected at a resolution as low as once per second. This feature is available with the download option only.

4 Safety WARNING Power the ECM-1220 with the supplied UL/CSA approved wall transformer only. For indoor use only. If installation is required in a damp location. Power the ECM-1220 via a GFI/GFCI protected outlet. Installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed must be performed by a qualified person or electrician. This individual must be familiar with the proper safety practices and equipped with the required PPE (Personal Protective Equipment). Any installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed are to comply with local safety codes and regulations. Never connect the provided current clip to a bare or un-insulated conductor. Prior to installation, always inspect the condition of the current transformer cable. Any damage to the cables outside insulations must be repaired or the CT (current transformer) replaced. When using the WPA-3 adaptor, always check the condition of the wire loop insulation before branching into an electrical outlet. Check for cuts or damages to the insulation that would cause the centre conductor to be exposed... never pull on the loop to unplug the adaptor!

5 Quick Start It is recommended that you use the simple Quick Start setup in the diagram below when using the ECM-1220 for the first time. This will allow you to verify the proper PT and CT settings (see Introduction for explanation of PT & CT) against a known load. Although a 100W incandescent light bulb is not an accurate standard, it should cause the ECM-1220 to read approximately 100W. This will likely be a bit higher for line voltages greater than 120V or lower for voltages less than 120V. This setup will also allow you to get familiar with the ECM-1220 s functions and options. Once all connections have been completed according to the Quick Start Connection diagram, press the ESC key a few times to take you to the main menu. Using the UP and DOWN keys, select option number one Display, then press select SEL. Pressing the UP key will scroll through various display options on the top line. Pressing the DOWN key will scroll through various display options on the bottom line. When displaying power ( Watts ), verify that this value is approximately that of the light bulb.

6 Verifying / Changing Settings Read all safety precautions relating to the type of monitoring installation used. Verify the PT setting of the monitor matches that of the supplied Wall Transformer. This is factory set to the PT that is shipped with the unit. Generally, there is no need to change this value unless a different PT is used for a specific application. Verify the CT setting with that of the CT you will be using. A separate setting is required for each channel based on the CT type being used. The default value from the factory is TYPE: 100 and RANGE: 5. This makes it compatible with the Split-60 (SCT-60-B) CT. SEL The Select key behaves similarly to the ENTER key on a computer. The DOWN arrow is mostly used for scrolling down. The UP arrow is mostly used for scrolling up. ESC The Escape key causes the current display to go back to the previous computer.

7 Flowchart showing the various ECM-1220 settings and the key sequence required Setup Options 1.Modify.Modify Cost Cost Of Of Electricity? Set Set Billing Rate 10.7 c // kwh Increment or or Decrement Rate Rate (cost of of electricity) then then Press SEL SEL Main Menu 2. 2. Modify Modify Proj Proj Period Period? Set Set Proj. Period 30 30 Days Increment or or Decrement # of of Days the the Projection is is Based on, on, then then Press SEL SEL Display 3. 3. Modify Modify Logger Logger Storage Storage Interval? Store To To Logger Every 15 15 Mins Increment or or Decrement How How Often (( minutes )) the the Data Data Logger Will Will Store Records, then then Press SEL SEL Setup Setup Reset Reset 4. 4. Reserved ----- ------ - Reserved for for Future Options Firmware (Future Options) 5. 5. Select Select CT CT Type Type? > Ch1 Ch2 Selects CH1 CT CT Options then SEL Selects CH2 CT CT Options then SEL Type: Range 100 100 5 6. 6. Select Select PT PT Type Type? Type Range 230 230 4 Incr. PT PT Type Incr. PT PT Range Press SEL when done Incr. Incr. CT CT CT CT Type Range Press SEL when done

8 Installation 120V Wall Plugged Load: If you wish to monitor a load which connects to a standard electrical outlet, use the diagram below to assist you in the installation.

9 120V Panel circuit: WARNING Installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed must be performed by a qualified person or electrician. This individual must be familiar with the proper safety practices and equipped with the required PPE (Personal Protective Equipment). Any installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed are to comply with local safety codes and regulations. Prior to installation, always inspect the condition of the current transformer cable. Any damage to the cables outside insulations must be repaired or the CT (current transformer) replaced. The illustration below demonstrates a typical installation for monitoring a 120V load at the panel. Example loads would be: Any hardwired (permanently connected) appliance such as a dishwasher. A load where the plug connection is too difficult to access such as a refrigerator. Room lighting circuit Multiple loads connected to one circuit

10 240V Load From The Panel: WARNING Installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed must be performed by a qualified person or electrician. This individual must be familiar with the proper safety practices and equipped with the required PPE (Personal Protective Equipment). Any installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed are to comply with local safety codes and regulations. Prior to installation, always inspect the condition of the current transformer cable. Any damage to the cables outside insulations must be repaired or the CT (current transformer) replaced. The illustration below demonstrates a typical installation for monitoring a 240V load at the panel. One CT would be clamped on to the BLACK wire to the breaker and the other to the RED (occasionally a second black lead is used rather than red). Do not clamp the CT around the WHITE neutral conductor! Example loads would be: Central Air conditioning unit Clothe Dryer Electric Range Hot Tub, Spa or Sauna Electric Space /Baseboard Heater Feed to a Remote Sub Panel such as power to a garage, separate apartment, pool house, etc

11 Entire Service Panel or Sub-Panel: WARNING Installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed must be performed by a qualified person or electrician. This individual must be familiar with the proper safety practices and equipped with the required PPE (Personal Protective Equipment). Any installations requiring access to service panels, sub panels, junction box or any others situations where live wires are exposed are to comply with local safety codes and regulations. Prior to installation, always inspect the condition of the current transformer cable. Any damage to the cables outside insulations must be repaired or the CT (current transformer) replaced. The installation required for monitoring entire service panels or sub-panels is displayed in the diagram on the right. One CT would be clamped on to the BLACK wire to the main breaker and the other to the RED (occasionally a second black lead is used rather than red). Read safety instructions above! Do not clamp the CT around the WHITE neutral conductor!

12 Viewing Information The first option on the Main Menu is Display. Once installed and setup, your monitor will be in this mode for viewing the desired values. ECM-1220 Flowchart Display Options CH x* Days, Hours, Minutes, Seconds Main Menu Channel To Be Displayed Chan #1 CH x* CH x* CH x* Rate: Proj. = Line Voltage (Volts) Kilowatt-Hour Energy (kwh) Power (Watts) xx.x Cents per kwh (c/kwh) xxx Days The Key selects the parameter to be displayed on Line #1 of the LCD display. LCD Display Display Chan #2 CH x* : DISPLAYS CH1 or CH2 or Tot total of CH1 + CH2 Display: Line # 1 Display: Line # 2 Power (Watts) Setup Line Current (Amps) Reset Firmware (Future Options) Total (sum of CH1 +CH2) Peak (Max) Power (Watts) Proj $ xxx.xx Proj. kwh xx,xxx.xxx Cost: $ xxx.xx CH x Kilowatt-Hour Energy (kwh) The Key selects the parameter to be displayed on Line #2 of he LCD display. After selecting the Display screen, you need to select which channel you would like to view. The Total option displays the sum of channel one and two. This option is handy when monitoring a 240V load using two CTs. The Total will be the sum of the power from each leg. Use the UP or DOWN key to select the desired channel, then SEL.

13 The Display screen shows various parameters. The top line of the LCD display is independent of the bottom line. This provides the user with a multitude of display options. To change the top line, use the UP key. The DOWN key will change the bottom LDC display line. In the display mode, SEL has effect on only one parameter, PEAK. The Peak display is used to record the highest Watt value monitored. To reset (erase) the Peak value, press the SEL button for approximately 6 seconds, while on the Peak display. Resetting the Unit Option 3. Reset from the main menu is used to reset all cumulative values to zero. This option has two prompt pages, to help prevent accidental erasure of data. Firmware Option 4. Firmware displays the firmware version of your monitor. What is firmware? The firmware is the program that runs the Energy Monitor. This is equivalent to a computer program. The computer program performs certain tasks and has specific features. On occasion, the software company may release a new version of their software with more options or improvements. The same is true for the ECM-1220 s firmware. It is called firmware because it stays resident in your Energy Monitor and the unit will always boot-up with this program. As Brultech Research releases newer versions of the firmware with improvement, the end user may upgrade the firmware by re-programming the ECM-1220 s internal memory. The firmware and required drivers and software are downloadable from /ecm1220/firmware. The optional USB data cable may be ordered from the company you purchased your monitor from.

14 Data Logger The data logger section is only viewed by downloading the collected data using the optional software. How the Logger Collects/Records Data: The data logger section of your monitor continuously tracks the amount of energy used, then at the user selected storage interval, stores the average energy for that period. For example: Suppose the monitor s storage interval is set to store data every 10 minutes and during 5 minutes of that interval a 500 watt loads is operated, then OFF for 5 minutes, the stored data would be 250 watt. This is the average power used during that interval. Once downloaded the software will calculate and display the accumulated kilowatt-hour during that interval. For the same scenario as above, if the storage interval was set to 1 minute storage interval, after 10 minutes, 10 data records would have been stored; 5 records of 500 watt and 5 records of 0 watt. From this example, it is obvious that a lower storage interval is preferred. The trade-off is the amount of time you can monitor before the data logger memory becomes full. The data logger collects and stores data at its user programmed storage interval until the memory is full. Once the memory is full, it WILL NOT overwrite the data. At that point the data is no longer recorded. This has NO EFFECT on the Energy Consumption Monitor s operation, as it will continue to operate normally. When the Energy Monitor is RESET, the data logger memory is cleared then starts logging at the beginning. This also resets the Energy Monitor s cumulative data such as KWh, Cost and Elapsed Time. Downloading Data Logger Records: The download software is optional and comes with various drivers and USB data cable. Before data can be downloaded for the first time, two drivers will need to be installed on the computer. The software CD has the drivers and installation instructions. Once the drivers are installed the Energy Monitor is then connected to the USB port of your computer with the supplied data cable. (When connected for the first time, Windows will discover the new hardware). The download procedure is straightforward, using the software.

15 Real Time Data The optional software comes with the ability of viewing energy usage in real time (as it happens). When enabled with the software, data is transferred to the connected computer every second. The data transferred is: CH1 Power (watt) CH2 Power (Watt) Line Voltage (volt) This information is displayed in a scrolling box. The data displayed can be transferred from the box to another program by highlighting the records, saving it to the clipboard, then pasting it into your application. When pasting to a spreadsheet, the tab delimited option should be used. Specifications Display: 2 Lines X 16 Characters Alpha Numeric Blue background with white backlight Size: 5 ½ X 4 X 1 ½ Power: Digitally sampled true power. 1 Watt to 65,000 Watt ( 1 Watt resolution) Power/KWH Accuracy: ± 1% plus CT accuracy Typically ± 2% with most current sensors Energy: Voltage:.001 kwh to 16,777.216 kwh (.001 kwh resolution) 85V to 480V depending on the Potential Transformer used. Standard Package Comes With PT: CT Inputs (balanced): Line Voltage: 85V to 130V Secondary: Use ONLY supplied Wall Transformer 12VAC 300mA 3.5mm mono phone plug 333mV RMS Full Scale, 353mV RMS Max Input Impedance: 20Kohm Stereo 3.5mm Plug: Ring(-V), Tip(+V) Sleeve(N.C.)

16 CT Inputs (unbalanced): 3.0 V RMS Max Input Impedance: 107 Ohm Mono 3.5mm Plug: Tip(+) Sleeve(-) Input Current: Dependant on Current Transformer Wall Plug Adaptor (WPA-3) Rating: 120 VAC 15 Amps Elapsed Monitoring Time: Rate (cost for electricity): Displayed Cost of Energy: Projection Period: MAX: 255 days, 23 hrs, 59 min, 59 seconds (1 second resolution) 0.1 /kwh to 99.9 /kwh (in 0.1 /kwh resolution) 0.1 to $ 12000.00 Data Logger Storage Interval: Data Logger memory: 1 day to 255 days (typically set to 7days, 30 days, 60days or 90 days) From 1 minute to 255 minutes (1 minute increments) (Stored data is the average of thousands of samples over that period) EEPROM Technology (non-volatile) Standard Unit 13,080 records Optionally expandable to 52,401 records (in 13,107 increments) Firmware: Flash, user reprogrammable