Continuous level measurement Radar transmitters

Similar documents
Continuous level measurement Radar transmitters

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation

Configuration. Installation

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Level Measurement Continuous level measurement - Ultrasonic controllers

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Siemens AG Continuous level measurement Ultrasonic controllers

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Level Measurement Continuous level measurement - Ultrasonic controllers

Disclaimer of Liability

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers

Continuous level measurement Ultrasonic transducers

Radar Transmitters. SITRANS LR560 (ma/hart) Operating Instructions 12/2011 SITRANS

Flow Measurement SITRANS F US Inline

SITRANS L Level instruments

Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers

Supplementary Components WirelessHART products

Disclaimer of Liability

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F US Inline

Radar Transmitters. SITRANS LR560 (ma/hart) Operating Instructions

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Spare Parts for RM71 SmartLine Guided Radar Level Meter

Series 3730 Type Electropneumatic Positioner

Continuous level measurement Ultrasonic transducers

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Quick Start Manual April English Dansk Deutsch. Español Français Italiano Nederlands Português Suomi Svenska. sitrans LG200

Radar Transmitters. SITRANS LR560 (ma/hart) Quick Start Manual 03/2013 SITRANS

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Flow Measurement SITRANS F C

SITRANS T measuring instruments for temperature

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

General Specifications

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Series 3730 Electropneumatic Positioner Type

Radar Transmitters SITRANS LR460 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

T EN TROVIS Electropneumatic Positioner

General Specifications

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Technical Data. General specifications. Rated operating distance s n 3 mm

PROFIBUS-PA Positioner Type 3785

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

WirelessHART Adapter SWA70

SITRANS P measuring instruments for pressure

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Micro Motion Model 2400S Transmitters with MVD Technology

Quick Start Manual January sitrans LR260 (HART)

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Radar Transmitters SITRANS LR250 (HART) Operating Instructions 01/2012 SITRANS

Flow Measurement SITRANS F C

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Level limit switch Series RF 3000 Selection list. Overview 2

Radar Transmitters SITRANS LR260 ( PROFIBUS PA) Quick Start Manual 12/2013 SITRANS

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3730 Type Electropneumatic Positioner

Supplementary Components WirelessHART products

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Weighing Electronics Stand-alone integrators

Instruction Manual May sitrans LR400

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

SITRANS F flowmeters SITRANS F US

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427

Temperature Measurement SITRANS TS300

Continuous level measuring system NB 3000 Selection list

Dräger Polytron 8200 Stationary gas detector (CatEx)

Electropneumatic Positioner Type and Type with HART communication

Radar Transmitters SITRANS LR250 (HART) Operating Instructions 11/2012 SITRANS

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Flow Measurement SITRANS F US Clamp-on

and High Temperature Velomitor * System

Resistance thermometer With spring-loaded tip Model TR55

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

Series Electropneumatic Positioner Type and Type with HART communication

Selection and Ordering data. Selection and Ordering data

Series 3730 Electropneumatic Positioner Type and Type with HART communication

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

1 Overview. Pressure Measurement Transmitters with WirelessHART. 1/36 Siemens FI US Edition. SITRANS P280 for gauge and absolute pressure

Radar Transmitters SITRANS LR260 (PROFIBUS PA) Operating Instructions 12/2013 SITRANS

Radar Transmitters SITRANS LR260 (PROFIBUS PA) Operating Instructions 12/2013 SITRANS

Capacitance level switches LS 210 LS 220

Transcription:

Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and in line with the antenna There is signal transmitted outside of the beam angle; therefore false targets may be detected 4 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). Benefits Rugged stainless steel design for industrial applications 78 GHz high frequency provides very narrow beam, virtually no mounting nozzle noise, and optimal reflection from sloped solids Aimer option to direct beam to area of interest, such as draw point of cone Lens antenna is highly resistant to product build up Air purge connection is included for self-cleaning of extremely sticky solids Local display interface (LDI) allows local programming and diagnostics Application s plug and play performance is ideal for most solids applications, including those with extreme dust and high temperatures to 200 ºC (392 ºF). Unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. includes an optional graphical local display interface (LDI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile display for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. measures practically any solids material to a range of 100 m (328 ft). Key Applications: cement powder, plastic powder/pellets, grain, coal, wood powder, fly ash Aiming will assist in measuring material in the cone installation, dimensions in mm (inch)

Technical specifications 1) From sensor reference point Mode of operation Measuring principle Frequency Minimum detectable distance Maximum measuring range 1) Output Analog output Communications Fail-safe Performance (according to reference conditions IEC60770-1) Maximum measured error (including hysteresis and non-repeatability) Rated operating conditions (according to reference conditions IEC60770-1) Installation conditions Location Ambient conditions (enclosure) ambient temperature installation category Radar level measurement 78 GHz FMCW 400 mm (15.75 inch) from sensor reference point 40 m (131 ft) version 100 m (328 ft) version 4... 20 ma HART Optional: PROFIBUS PA Optional: Foundation Fieldbus Programmable as high, low or hold (Loss of Echo) NE43 programmable Greater of 25 mm (1 inch) or 0.25 % of range from minimum detectable distance to full range Indoor/outdoor -40... +80 C (-40... +176 F) I pollution degree 4 Medium conditions Dielectric constant r > 1.6 temperature and pressure See chart below Design Enclosure Construction 316L/1.4404 stainless steel Conduit entry M20x1.5, or ½" NPT via adapter Purge inlet 1/8" NPT, 30 cfm at max. 100 psi Lens material 40 m version: PEI 100 m version: PEEK Damage to lens could result from continuous purging/cleaning due to abrasive solids. Recommended purging/cleaning only a few seconds every hour Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA 6, IP68 with lid closed Weight 3.15 kg (6.94 lb) including 3inchflange Optional local display interface Graphic LCD, with bar graph representing level connections Universal flat-faced flanges 2) Aimer flanges 2) 3, 4, 6 inch/80, 100, 150 mm, 304 stainless steel 3, 4, 6 inch/80, 100, 150 mm, 316L/1.4404 or 316L/1.4435 stainless steel 3, 4, 6 inch/80, 100, 150 mm, polyurethane powder-coated cast aluminum Power supply 4... 20 ma/hart Nominal 24 V DC (max. 30 V DC) with max. 550 PROFIBUS PA/ FOUNDATION Fieldbus Certificates and approvals General Radio 2) Universal flange mates with EN 1092-1 (PN 16)/ASME B16.5 (150 lb)/ JIS 2220 (10K) bolt hole pattern. temperature and pressure 13.5 ma 9... 32 V DC, per IEC 61158-2 CSA US/C, CE, FM Europe (R&TTE), FCC, Industry Canada, C-TICK Hazardous Europe/International IECEx SIR 09.0149X ATEX II 1D, 1/2D, 2D Ex ta IIIC T139 ºC Da IP68 ATEX II 3G Ex na II T4 Gc Ex nl IIC T4 Gc US/Canada FM/CSA Class II, Div. 1, Groups E, F, G Class III T4 FM/CSA Class I, Div. 2, Groups A, B, C, D, T4 China NEPSI Ex na II T4 Ex nl IIC T4 DIP A20 TA, T139 ºC, IP68 Brazil INMETRO BR-Ex na/nl II T4 IP68 Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld IS model: programmer ATEX II 1GD Ex ia IIC T4 Ga Ex iad 20 T135 C Ta = -20... +50 C CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a =50 C Handheld communicator HART communicator 375/475 PC SIMATIC PDM, AMS, PACTware Display (local) Graphic local user interface including quick start wizard and echo profile displays Version Stainless steel Aimer flange: -1 to 0.5 bar 40 m -40... +100 C (-40... +212 F) 100 m -40... +200 C (-40... +392 F) -40... +100 C (-40... +212 F) -40... +200 C (-40... +392 F) Aimer flange: -1 to 3.0 bar -40... +100 C (-40... +212 F) -40... +120 C (-40... +248 F) Siemens FI 01 2014 4/265

Siemens AG 2013 1) Rated to 120 ºC max. when used with Pressure rating option 1 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Plug M12 with mating connector 1)2)3) Plug 7/8" with mating connector 1)3)4) Order code A50 A55 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 10204 4) C12 NAMUR NE43 compliant, device preset to failsafe < 3.6 ma 5) N07 Operating Instructions for HART device Article No. English 7ML1998-5KB02 German 7ML1998-5KB32 Multi-language Quick Start manual A5E32052143 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English 7ML1998-5LT02 German 7ML1998-5LT32 Multi-language Quick Start manual A5E32043113 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for Foundation Fieldbus device English 7ML1998-5LY02 German 7ML1998-5LY32 Multi-language Quick Start manual A5E32034712 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Hand Programmer, Intrinsically safe 7ML1930-1BK Local display interface 7ML1930-1FJ Sun Shield Cover 7ML1930-1FK Housing lid with window 7ML1930-1FL One metallic cable gland M20x1.5, 7ML1930-1AP rated -40... +80 C (-40... +176 F), HART 6) One metallic cable gland M20x1.5, rated 7ML1930-1AQ -40... +80 C (-40... +176 F), PROFIBUS PA 6) SITRANS RD100 Remote display - see Chapter 7 SITRANS RD200 Remote display - see Chapter 7 SITRANS RD500 web, datalogging, alarming, ethernet, and modem support for instrumentation - see Chapter 7 Selection and Ordering data Article No. 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range 7ML5440-777 0 0-77 7 7 of 100 m (329 ft). Order handheld programmer separately Measurement and process temperature range 40 m (131 ft) max range, -40... +100 C 0 100 m (329 ft) max range, -40... +200 C 1 connection Universal flat-faced flange fits ANSI/DIN/JIS flanges 3 inch/80 mm, 304 stainless steel A 4 inch/100 mm, 304 stainless steel B 6 inch/150 mm, 304 stainless steel C 3 inch/80 mm, 316L stainless steel D 4 inch/100 mm, 316L stainless steel E 6 inch/150 mm, 316L stainless steel F 3 inch/80 mm, painted aluminum, with integral aimer 1) G 4 inch/100 mm, painted aluminum, with integral H aimer 1) 6 inch/150 mm, painted aluminum, with integral J aimer 1) Enclosure (with cable inlet) Stainless steel, 1 X ½" NPT A Stainless steel, 1 X M20 x 1.5 B (plastic gland included) Pressure rating 0.5 bar g (7.5 psi g) maximum 0 3 bar g (40 psi g) maximum 1 Output/communication 4... 20 ma, HART A PROFIBUS PA B Foundation Fieldbus C Approvals General Purpose, CSA US/C, Industry Canada, FCC, A CE, R&TTE, C-TICK CSA/FM Class I, Div. 2, Groups A, B, C, D, Class II, B Div.1, Groups E, F, G, Class III ATEX II 1 D, ½ D, 2 D, 3G Ex na/nl, CE, R&TTE, C C-TICK Local display interface Without LDI (local display interface) 1 With LDI (local display interface) 2 7ML5750-1AA00-0 1) Available with Approval option A only 2) Available with Enclosure option B only 3) Available with Output/communication options B and C only 4) Available with Pressure rating option 1 only 5) Available with Output/communication option A only 6) Product shipped with plastic cable gland, rated to -20 C. If -40 C rating required, then metallic cable gland is recommended. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. 4/266 Siemens FI 01 2014

Options Handheld programmer Part number: 7ML1930-1BK Sun shield cover Part number: 7ML1930-1FK handheld programmer and sun shield cover Siemens FI 01 2014 4/267

Characteristic curves Siemens AG 2013 Temperature derating curve Ambient temperature 90 80 70 temperature Ambient temperature ( C) 60 50 40 30 20 40 m version 100 m version 10 0 50 100 150 200 250 temperature ( C) temperature derating curve Dimensional drawings Flat flange 3 aimer flange 4 and 6 aimer flange* Lid lock Grounding lug Purge plug connection: flat flange 176 (6.93) Grounding lug Purge plug connection: 3 aimer flange 166.1 (6.54) 22.3 (0.92) Crounding lug Purge plug connection: 4 and 6 aimer flange 166.1 (6.54) A Sensor reference point 110 (4.33) 200 (7.87) 9.6 (0.38) 229 (9.02) 110 (4.33) 4 : 229 (9.02) 6 : 285 (11.22) 110 (4.33) 9.6 (0.38) 10º max. * C Spanner wrench included 5º max. A5E02771629 A 4 53.2 (2.09) 6 60 (2.36), dimensions in mm (inch) 4/268 Siemens FI 01 2014

Specials Schematics Specials Article No. LR560 Electronics Modules (or NPTcable entry) Cable shield (if used) LR560 Electronics Module,HART,100 m range, compatible with 7ML54401XX00XAXX, no enclosure or LR560 Electronics Module,PROFIBUS PA,100 m range, compatible with 7ML54401XX00XBXX, no enclosure or 7ML1830-3AC 7ML1830-3AH Connect the wires to the terminals as shown: the polarity is identified on the terminal block. LR560 Electronics Module,Foundation Fieldbus,100 m range, compatible with 7ML54401XX00XCXX, no enclosure or LR560 Electronics Module,HART,40 m range, compatible with 7ML54400XX00XAXX, no enclosure or 7ML1830-3AJ 7ML1830-3AK Notes: 1. Depending on the approval rating, glands and plugs may be supplied with your instrument. 2. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC 61010-1. 3. All field wiring must have insulation suitable for rated input voltages. 4. Use shielded twisted pair cable (14 to 22 AWG) for HARTversion. 5. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. connections LR560 Electronics Module,PROFIBUS PA,40 m range, compatible with 7ML54400XX00XBXX, no enclosure or LR560 Electronics Module,Foundation Fieldbus,40 m range, compatible with 7ML54400XX00XCXX, no enclosure or LR560 Miscellaneous Spare Kits Kit, Lid Gasket, EPDM, LR560 Kit, Wrench for 4" and 6" Aimers, LR560 Kit, O-rings for 3" Aimer, LR560 Kit, O-rings for 4" Aimer, LR560 Kit, O-rings for 6" Aimer, LR560 Kit, Lid Screw and Purge Plug set with Hex Keys, LR560 Kit,Lid, No Window, LR560 7ML1830-3AL 7ML1830-3AM 7ML1830-3AA 7ML1830-3AB 7ML1830-3AD 7ML1830-3AE 7ML1830-3AF 7ML1830-3AG 7ML1830-3AP Please contact ceg.smpi@siemens.com for special requests. Siemens FI 01 2014 4/269