Flow Measurement SITRANS F US Inline

Similar documents
Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Flow Measurement SITRANS F C

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Flow Measurement SITRANS F C

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

SITRANS T measuring instruments for temperature

Flow Measurement SITRANS F US Clamp-on

Continuous level measurement Radar transmitters

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19" insert/19" wall mounting. 4/134 Siemens FI

SITRANS F flowmeters SITRANS F US

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Flow Measurement SITRANS F C

Level Measurement Continuous level measurement - Ultrasonic transducers

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement - Ultrasonic transmitters

Flow Measurement SITRANS F US Clamp-on

Supplementary Components WirelessHART products

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement - Ultrasonic controllers

SITRANS L Level instruments

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

Level Measurement Continuous level measurement - Ultrasonic transmitters

Technical Information Promonitor NRF560

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

Ultra Sonic Flowmeter DATASHEET

SITRANS P measuring instruments for pressure

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

T EN TROVIS Electropneumatic Positioner

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic controllers

OPTIFLEX 1100 C Technical Datasheet

Level Measurement Continuous level measurement Ultrasonic controllers

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement SITRANS F US Inline

Technical Information RIA16

Continuous level measurement Ultrasonic transducers

Series 3730 Type Electropneumatic Positioner

Flow Measurement SITRANS F US Inline

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

MID approval no. DE-08-MI004-PTB004 Date of release

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F US Inline

SITRANS F US Inline. SITRANS FUE950 energy calculator 4/269

Ultrasonic Flow Meter Brochure

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Level Measurement Continuous level measurement - Ultrasonic controllers

OPERATING INSTRUCTIONS

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level Measurement Continuous level measurement - Ultrasonic controllers

Capacitance level switches LS 210 LS 220

Flow Meter FC01-Ex FC01-Ex

Grounding Monitoring Device Series 8485

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Data sheet deltwavec-f

1 Overview. Pressure Measurement Transmitters with WirelessHART. 1/36 Siemens FI US Edition. SITRANS P280 for gauge and absolute pressure

CURRENT TO PROFIBUS PA CONVERTER

Siemens AG Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Ultrasonic Heat Flow Meters

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

PTU300 Combined Pressure, Humidity and Temperature Transmitter

General Specifications

... f l o w measurement & control...

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Series DMHF Heat Meter

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Stratos Pro A4 PH. Connection

General Specifications

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Grounding Monitoring Device Series 8485

Series 3730 Electropneumatic Positioner Type

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Level and Flow Measurement. dbi Transducers. HART and Profibus PA Intelligent Transducers

Speed switches Programmable, digital speed switch With incremental encoder POG 10

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

KATflow 150 Ad vanced Clamp-On U ltrasonic Flowmeter

PDW30 Point-To-Point Wireless Bridge

Level measurement. Applications. Special features. Description

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Clamp-On Transit Time Ultrasonic Flow Meters

Continuous level measuring system NB 3000 Selection list

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Digital electropneumatic positioner

THE TECHNOLOGY BEHIND THE MEASUREMENT

Inductive sensor NI3-EG08K-Y1-H1341

Transcription:

Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication PC/laptop and SIMATIC PDM software using PROFIBUS PA communication min. 20 Ω SITRANS FUS060 is a transit time based transmitter designed for ultrasonic flowmetering with dedicated sensors in the FUS inline series up to DN 4000. SITRANS FUS060 is engineered for high performance and is suitable for 1-path, 2-path and 4-path flowmeters. Benefits Superior signal resolution for optimum turn down ratio Simple menu-based local operation with two-line display and four optical input elements, for unlimited use in potentially explosive atmospheres Self-monitoring and diagnostic Operate up to 4 paths ATEX II 2 G Ex dem [ia/ib] IIC T6/T4/T Gb Remote installation up to 120 m from sensor 1 analog output (4 to 20 ma) standard with HART-protocol, 1 digital frequency or pulse output, 1 relay output for limit, alarms, flow direction PROFIBUS PA Profile 2, 1 digital frequency or pulse output Design The transmitter type FUS060 is designed for remote installation in non-hazardous or hazardous areas. The transmitter is designed for use in a flowmeter system together with sensors type SONOKIT, SONO 00 and SONO 100. The FUS060 is ordered as part of a complete flowmeter system. It can be ordered separately as spare part and manually programmed with the sensor data. Application The main application for flowmeters with the transmitter SITRANS FUS060 is measurement volume of flow within the general, petrochemical and chemical industries, power engineering and water and waste water, as well as various types of oils and liquid gases. Integration The transmitter output is often used as input for an automation system or as input for systems of remote reading. The SITRANS FUS060 transmitter offers current, pulse and relay outputs as standard output functions and supports HART or Profibus PA communication. The settings of the transmitter output functions are individually programmed via keypad and display menu. /246 Siemens FI 01 2016 Operating and display panel HART communication Master PROFIBUS PA communication The operating and display panel permits simple operation without supplementary equipment. It is not necessary to open the housing. All changes to a setting can therefore also be carried out in the potentially explosive atmosphere. Operating and display panel PC/ laptop HART Coupling communicator module RS 22 PROFIBUS DP + Coupler with power supply PROFIBUS PA... Transmitter with PROFIBUS PA interface Optical keypad Infrared key T Bus term. LCD-Display (2 lines à 16 characters with backlight)

The individual functions and parameters are selected using a hierarchical, multi-language input menu and four infrared keys. The parameters can be specifically selected and modified using codes, e.g.: Operating parameters such as measuring range, physical dimensions, device information Limits for flow, totalizer, ultrasonic velocity or ultrasonic amplitude Noise suppression using damping, error stages and hysteresis Display parameters (freely-configurable display) Display in volume or mass dimensions Density as constant input value for conversion of volume into mass dimensions Forward/backward measurement Flow direction Diagnostics functions and control values Functions of the PROFIBUS PA output: flow, net quantity (volume or mass), ultrasonic velocity, ultrasonic amplitude, forward quantity (volume or mass), backward quantity (volume or mass) Functions of the analog output: flow, ultrasonic velocity or ultrasonic amplitude Functions of digital output 1: pulse output, frequency output, limit, flow direction or device status Functions of digital output 2: limit, flow direction or device status Simulation of output signal via analog output, digital output 1 and digital output 2 The HART protocol is implemented via the analog output (current output). Using this communication facility, the device can be parameterized with a PC/laptop and SIMATIC PDM software in addition to local operation. In the version with PROFIBUS PA, the analog output is replaced by the digital PROFIBUS PA output. The device can then be parameterized via PROFIBUS communication and with SIMATIC PDM in addition to local operation. Technical specifications Input Measurement Nominal diameters and number of paths Max. cable length Output Function Flow by measuring the transit time difference of ultrasonic signals through ultrasonic transducers in DN 100 (4")... 000 (120") 2-path sensor pipes (depending on selected size, 1-path or 4-path special solutions are possible). 2-path DN 100 (4")... DN 000 (120") (depending on size, optionally also 1-path and 4-path) 120 m (95 ft) (shielded coaxial cable). For Ex version the transducer cable length is restricted to m (9.84 ft) in order to meet requirements for electrical immunity. For systems with sizes DN 1500 (60") cable length is recommended to be max. 0 m (98.4 ft). Current output programmable for flow, sound velocity or amplitude level. Analog output Active current output (1.2 V < open loop voltage < 15.8 V) Signal range 4... 20 ma Upper limit Signal on alarm Load Only PROFIBUS PA version: Digital output 1 Function Active or passive signal, can be configured with positive or negative logic For explosion protection (ATEX version) and PROFIBUS PA version Output function, configurable 20... 22.5 ma, adjustable.6 ma, 22 ma, or 24 ma Max. 600 for non Ex version 20 for HART communication 0 for Ex-version Analog output omitted, is replaced by digital PROFIBUS PA interface Pulse, frequency or status output - programmable for pulses, frequency, alarm, limit or status. Active: 24 V DC, 24 ma, R i = 00 Passive: open collector, 0 V DC, 200 ma Only passive: open collector 0 V DC, 100 ma Pulse output Adjustable pulse significance 5000 pulses/s Adjustable pulse width 0.1 ms Frequency response f END selectable up to 10 khz Limit for flow, totaliziers,ultrasonic velocity or ultrasonic amplitude device status, flow direction Siemens FI 01 2016 /247

Digital output 2 Function Relay, NC or NO contact For explosion protection (ATEX version) Output function, configurable Only PROFIBUS PA version: Communication via analog output 4... 20 ma PC/laptop or HART communicator with SITRANS F flowmeter - Load with of coupling module - Load with of HART communicator Relay output - programmable for alarm, limit or status indication. Switching capacity max. 5 W Max. 50 V DC, max. 200 ma DC Self-resetting fuse, R i = 9 Max. 0 V DC, max. 100 ma DC, 50 ma AC (cf. EC-Type Examination certificate) Limit for flow, ultrasonic velocity or ultrasonic amplitude flow direction device status Digital output 2 omitted min. 20 (max. 0 for Ex-version) min. 20 - Cable 2-wire shielded km ( 1.86 miles) Multi-core shielded 1.5 km ( 0.9 miles) - Protocol HART, version 5.1 Communication via PROFIBUS PA interface Power supply Current consumption from bus Electrical isolation Accuracy Error in measurement (at reference conditions) Pulse output Analog output Repeatability Reference conditions (water) Process temperature in the connected sensor Ambient temperature at the transmitter Transmitter warming-up time Installation conditions of connected sensor Layers 1 + 2 according to PROFIBUS PA Communication system according to IEC 61158/EN 50170 Separate supply, four-wire device Permissible bus voltage 9... 2 V See certificates and approvals 10 ma; 15 ma in event of error with electronic current limiting Outputs electrically isolated from power supply and from one another ± 0.5 % of measured value at 0.5... 10 m/s or ± 0.25/V[m/s] % of measured value at flow < 0.5 m/s As pulse output plus 0.1 % of measured value, 20 µa 0.25 % of measured value at 0.5... 10 m/s 25 C 5 C (77 F 9 F) 25 C 5 C (77 F 9 F) 0 min. Upstream section > 10 x DN and downstream section > 5 x DN Rated operation conditions Ambient conditions Ambient temperature Operation In potentially explosive atmospheres Storage -20... +50 C (-4... +122 F) Observe temperature classes Enclosure rating Electromagnetic compatibility Emitted interference Noise immunity Medium conditions Process temperature Gases/solids Design Separate version Enclosure material Wall mounting bracket (standard and special) Weight of transmitter Electrical Displays and controls Display Multi-display: 2 freely-selectable values are displayed simultaneously in two lines Operation Power supply Supply voltage -25... +80 C (-1... +176 F) For use in industrial environments To EN 55011/CISPR-11 To EN/IEC 6126-1 (Industry) The measuring media must be ultrasonic signal compatible. It must be homogeneous and not two-phased to transfer the acoustic ultrasonic signals. -200... +250 C (-28... +482 F) (not directly influenced by medium temperature) Influence accuracy of measurement (approx. max. % gases or solids) Transmitter is connected to the transducers via... 120 m (9.8... 95 ft) long specially shielded cables (coaxial cable) For ATEX versions mounted in the Ex area only with m (9.8 ft) long cables. Die-cast aluminum, painted Stainless steel (standard: always incl.) 4.4 kg (9.7 lb) Cable glands (always incl.) Power supply and outputs - 2 x M20 (HART)/ M25 (PROFIBUS) or - 2 x ½"-NPT (HART) Transducers/sensor - 2/4 x M16 or - 2/4 x ½" NPT LCD, two lines with 16 characters each Flow, volume, mass flow, mass, flow velocity, speed of sound, ultrasonic signal information, current, frequency, alarm information 4 infrared keys, hierarchical menu shown with codes Standard version 120... 20 V AC 15 % () or 19... 0 V DC/ Ex version Power failure Power consumption Certificates and approvals Explosion protection 19... 0 V DC/ No effect for at least 1 period ( 20 ms) Approx. 10 VA/10 W ATEX II 2 G Ex dem [ia/ib] IIC T6/T4/T Gb T6 for media < 85 C (185 F) T5 for media < 100 C (212 F) T4 for media < 15 C (275 F) T for media < 200 C (92 F) /248 Siemens FI 01 2016

Coaxial cable Standard Coaxial cable (75 ) Outside diameter Length Material (outside jacket) Coaxial cable with SMB straight plug on one end for to the FUS060 Ø 5.8 mm, 15, 0, 60, 90, 120 m (9.84, 49.21, 98.4, 196.85, 295.28, 9.70 ft) between sensor and transmitter black PE Ambient temperature -10... +70 C (14... 158 F) High temperature Coaxial cable (75 ) Outside diameter Length Material (outside jacket) Coaxial cable with SMB straight plug on one end for the to FUS060 Ø 5.1 mm (first 0. m (0.98 ft) part to the transducer), Ø 5.8 mm (for remaining cable to the transmitter - with SMB plug at the end) and between these is a black hot melt junction Ø 16 mm (length 70 mm), 15, 0, 60, 90, 120 m (9.84, 49.21, 98.4, 196.85, 295.28, 9.70 ft) between sensor and transmitter (max m 9.84 ft) transducer cable length for Ex area mounted transmitters) Brown PTFE (0. m (0.98 ft) part) and black PE (for remaining cable) Ambient temperature -200... +200 C (-28... +92 F) (brown PTFE transducer part) and -10... +70 C (14... 158 F) (black PE for remaining transmitter cable part) Dimensional drawings 248 (9.76) SITRANS FUS060 with standard mounting bracket, dimensions in mm (inch) 248 (9.76) SITRANS FUS060 with optional special mounting bracket, dimensions in mm (inch) Schematics 205 (8.07) 98.5 (.88) 15 (6.02) 100 (.94).5 (1.2) 220 (8.66) 250 (9.84) 248 (9.76) Ø80 (.15) 205 (8.07) 92 (.62) 15 (6.02) 105 (4.1) 89 (.50) 154 (6.06) Ø80 (.15) Earth for signal cable screen Digital output 2 (relays) (only for HART) Digital output 1 (active/passive) Analog output (active) 4... 20 ma (or PROFIBUS) Power supply: L/N for 120... 20 V AC L+/L- for 24 V AC/DC Earth terminal for PE 150 (5.91) 150 (5.91) 4 5 6 7 8 1 2 + 20 + ma L N L+ L Electrical SITRANS FUS060 Siemens FI 01 2016 /249

Transmitter FUS060 operating instructions, accessories and spare parts Operating instructions English German A5E01204521 A5E0212845 This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Accessories Standard wall mounting bracket Special wall-/pipe mounting bracket kit 7ME59-0AC04 7ME59-0AC05 Process Device Manager SIMATIC PDM SIMATIC PDM Details about the SIMATIC PDM tool can be found on page 8/9, chapter "Communication and Software" See page 8/17, chapter "Communication and Software" HART modem for communication with FUS060 HART, PC and SIMATIC PDM HART modem With USB 7MF4997-1DB Safety clamp for electronic cover with glass plate (7ME59-0AC01) 7ME59-0AC06 Spare parts SITRANS FUS060 transmitter, available standard and Ex versions The transmitter configuration is made in the flowmeter Order codes (together with the sensors). The information below is for spare part ordering only and with fixed standardized pre-settings for a DN 2000 2-path system. Version Enclosure Supply FUS060, 20 V, HART, FUS060, 20 V, HART, FUS060, 20 V, PROFIBUS, FUS060, 20 V, PROFIBUS, FUS060, 24 V, HART, FUS060, 24 V, HART, FUS060, 24 V, PROFIBUS, FUS060, 24 V, PROFIBUS, FUS060, ATEX, 24 V, HART, ATEX approval 115 20 V AC 115 20 V AC 115 20 V AC 115 20 V AC 19... 0 V DC/ 19... 0 V DC/ 19... 0 V DC/ 19... 0 V DC/ 19... 0 V DC/ 7ME050-2BA10-1BA1 7ME050-2BA10-1BA2 7ME050-2BA10-1DA1 7ME050-2BA10-1DA2 7ME050-2BA20-1BA1 7ME050-2BA20-1BA2 7ME050-2BA20-1DA1 7ME050-2BA20-1DA2 7ME050-2BA21-1CA1 Ordering of pre-configured FUS060 spare transmitters only via PVR (product variation request - special request) /250 Siemens FI 01 2016

Operating/Display module Electronics cover with glass plate (non Ex). Die cast aluminum, with corrosion-resistant Basic Polyester powder coating (min. 60 µm) Cover for sensor cable and gasket. Die cast aluminum, with corrosion-resistant Basic Polyester powder coating (min. 60 µm) Cover for mains supply/communication. Die cast aluminum, with corrosion-resistant Basic Polyester powder coating (min. 60 µm) FUS060 Sensor PCBA, Standard versions only, 1 pc. 7ME59-0AC00 7ME59-0AC01 7ME59-0AC02 7ME59-0AC0 A5E025511 M20 cable gland set for FUS060 ATEX version power and output, PA plastic, 1 x in blue (ATEX Ex i) and 1 x gray (ATEX Ex-e) (0.20"... 0.5") -20... +95 C (-4... +20 F) A5E0224656 1/2" NPT cable gland set for A5E0224696 FUS060 (NPT) power and output, gray PA plastic, 2 pcs. cables Ø 6... 12 mm (0.24"... 0.47") -40... +100 C M25 cable gland set for the FUS060 PA (M25) power and output, gray PA plastic, 2 pcs. cables Ø 9... 16 mm (0.5"... 0.6") -40... +100 C M16x1.5 cable gland set for FUS060 (M16) sensor, gray PA plastic, 2 pcs. and 2 pcs. blind. (0.20"... 0.5") -40... +100 C A5E0224678 A5E0259526 FUS060 Sensor PCBA, ATEX version only, 1 pc. A5E025514 M16 x 1.5 cable gland set for FUS060 (M16) sensor, brass chrome, 2 pcs. and 2 pcs. blind (0.20"... 0.5") -20... +105 C (-4... +221 F) A5E0224669 M20 cable gland set for A5E0224650 FUS060 (M20) power and output, gray PA plastic, 2 pcs. cables Ø 6... 12 mm (0.24"... 0.47") -40... +100 C ½" NPT cable gland set for FUS060 (NPT) sensor, 4 pcs. M16 bush to ½" NPT and 4 pcs. ½" NPT gray PA plastic glands (0.20... 0.5") -20... +100 C (-4... +212 F) A5E02247877 Siemens FI 01 2016 /251

Cables for FUS060 Length m (ft) Coaxial cable for FUS060, (75, max. 70 ºC (158 ºF), black PVC) (2 pcs.) High temp. coaxial cable for FUS060; with 0. m brown PTFE high temp. transducer part, max. 200 C (92 F) and black PVC for remaining transmitter part with SMB plug, max. 70 ºC (158 ºF), impedance 75 (2 pcs.) Special coaxial cable sets for low temperature cryogenic systems; with SMB plug for transmitter SITRANS FUS060, PTFE material, temp. -200... +200 C (-28....+92 F), impedance 75 (2 pcs.) (9.84) A5E00875101 15 (49.21) A5E0086142 0 (98.4) A5E01278662 60 (196.85) A5E01278682 90 (295.28) A5E01278687 120 (9.70) A5E01278698 (9.84) A5E00875105 15 (49.21) A5E0086145 0 (98.4) A5E01196952 10 (2.84) A5E0208559 15 (49.21) A5E0262088 0 (98.4) A5E02085644 40 (11.2) A5E02085649 /252 Siemens FI 01 2016