ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

Similar documents
Arecont Vision MegaDome 2 Installation Manual (DN Models Only)

Arecont Vision MegaDome Installation Manual

Arecont Vision MegaDome TM Installation Manual

Features. Parts Supplied. Parts not Supplied. Tools Required. ADC780 Series Indoor/Outdoor Vandal-Resistant Cameras. Installation and Setup Guide

IS-DM220/IR/HB IS-DM220

Full HD Speed Dome IP Camera

Quick Installation Guide

Warning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.

AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting. Siemens AB. Version 5.0 A Security Products

Installing the Camera

Installation and Set-up of Dome Camera Wall Arm (Zxx-WM2A)

Arecont Vision MegaView TM v1x Installation Manual

Roughneck V920D Series Camera Domes XX Quick Guide

AE-237. Outdoor Enclosure. Installation Guide. Rev IP Sur veillance. Ordering part no.: G AE-237_V01. Document part no.

MBE Mounts and Adapters

EN - 1. Warning Before Installation. Package Contents. Refer to your user s manual for the operating temperature.

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Arecont Vision HSG2 Installation Manual

Camclosure Integrated Camera Systems

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

DC Outdoor Power Supply/Chargers

IM-VESM Surface Mount Adapter

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

Arecont Vision MegaView TM v1 Installation Manual

Mounting on the Ceiling Using Flush Mount (Face Down)

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

FortiCam SD20 Mounting Guide

Next Gen Sarix Enhanced IME Series Mini Dome Cameras

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome

TruVision Dome Brackets Installation Manual

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

AE-241/242. Outdoor Enclosure. Installation Guide. Rev IP Sur veillance. Ordering part no.: G AE-241_V G AE-242_V01

MAXIMA+ Series Rotary Level Indicator

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

2M IR Mini Dome Quick Installation Guide

MAXIMA + Series ROTARY LEVEL CONTROL

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Standard Strip Series

dome camera. Image Inverse feature

TruVision 360 Camera Bracket Installation Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Data Sheet. V910 Impact-Resistant IP and Analog Camera Dome Series. Durable Construction and Easy Installation

1 Installing the VG4-A-ARMPLATE

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

FortiCam FD40 Mounting Guide

Warning Before Installation

FE8171V. 3MP 360 Panoramic View Vandal-proof

deview electronics MD4 Series Indoor Mini Domes

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

Next Gen Sarix Enhanced IME Series Mini Dome Cameras

B&W RearView Camera Installation & Operation

EX27/EX27N/EX27D All-Weather Cameras

BTU 4 & Sensors. Installation and Operation Manual

G12/G12x USER S MANUAL

CAUTION READ CAREFULLY

IM-VECM Corner Mount C2254M (2/11)

Installation and User Guide

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

110 Series Camclosure Integrated Camera System

GARDEN SPEAKERS GS4 INSTALLATION GUIDE RevA-GS4-SpkManual.indd 1


FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

Metham Aviation Design Limited Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Next Gen Sarix Enhanced IBE Series Bullet Cameras

IP816A-LPC-v2 License Plate Capturing Solution

Dome Camera. Hardware Manual Z81, Z /01/08

GV-IPCamera. Quick Start Guide. Vandal Proof IP Dome Target Vandal Proof IP Dome

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

MAXIMA + Series ROTARY LEVEL CONTROL

Camera Features. Package Contents. Camera Features

Network Camera. Quick Guide DC-D3C33HRX. Powered by

Please read the Operational Manual before attempting to use this product. Operational Manual

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Mounting Accessory Guide

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

To connect the AC adapter:

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

ETC Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

TruVision IP PTZ Camera Installation Guide

ORB TM 4-20 ma Input Box Installation & Operation Manual

Installation Manual. Wide Angle Models AV2225PMIR AV2225PMIR-A AV2226PMIR AV3225PMIR AV3226PMIR AV3226PMIR-A AV5225PMIR AV5225PMIR-A AV10225PMIR

TruVision Series 4 IP Camera Installation Guide

SWM-CA Series Corner Mount Adapter

deview electronics VDP20 Series Vandal Dome

SERVICE MANUAL MODEL SSW-520-F

200 Series Camclosure Integrated Camera System

Replacing the Power Supply

DC-D4213RX DC-D4213WRX

Parts and Service Manual IMCO

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

VITEK VTD-THD2RFE VTC-THT2RFE VTC-THB2RFE. 2.1 Megapixel Indoor/Outdoor HD-TVI/ AHD/CVI/CVBS IR Cameras

TruVision Series 5 IP Camera Installation Guide

IQeye Sentinel Series

Infrared Dome CCD Camera User Manual

VC240 Outdoor WDR Day/Night PoE Network Camera

TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS HP LASERJET 4600 TONER CARTRIDGE

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

diode led VALENT X SPECIFICATION SHEET 24VDC OVERVIEW FEATURES & BENEFITS COMPATIBLE CHROMAPATH CHANNELS

Transcription:

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS Please carefully read and observe all instructions and warnings contained in this manual or on the product. Improper installation may damage the device and void the warranty.

IMPORTANT Installation should be performed by a qualified service person and conform to all local codes. DESCRIPTION Model ZC-OH5 is a tamper resistant indoor or outdoor housing that is designed to accommodate all CBC ZC-D5000 series mini-dome cameras. This housing will accept the following camera models: ZC-D5029NHA/PHA ZC-D5212NHA/PHA ZC-D5550NHA/PHA ZC-DN5029NHA/PHA ZC-DN5212NHA/PHA ZC-DN5840NHA/PHA 1/3" Color hi-res dome, 540 TVL, 2.9-8.2mm AI varifocal 1/3" Color hi-res dome, 540 TVL, 2.8-12mm AI varifocal 1/3" Color hi-res dome, 540 TVL, 5-50mm AI varifocal 1/3" Color hi-res TRUE DAY/NIGHT dome, 540 TVL, 2.9-8.2mm AI varifocal 1/3" Color hi-res TRUE DAY/NIGHT dome, 540 TVL, 2.8-12mm AI varifocal 1/3" Color hi-res TRUE DAY/NIGHT dome, 540 TVL, 8.5-40mm AI varifocal MAJOR FEATURES Polycarbonate dome with rugged cast aluminum housing withstands the blow from a 10 pound sledgehammer O-ring sealed housing meets IP66 standards for use in virtually any weather conditions Quick-Lock tabs for easy installation and removal of camera module Built-in conduit access in dome base accepts 3/4 conduit Quick and easy installation utilizing 6 different dome camera options Housing mounts directly to any wall, ceiling or 4S Electrical box. INSTALLATION 1) Standard Housing Installation a) CAUTION: Do Not Remove Screws. Loosen the 3 set screws from the dome base using the supplied key and remove the dome cover (see FIGURE 1).The O-Ring makes a tight seal, so a thin-bladed screwdriver may be needed to separate the dome cover from the housing base by using the pry slots to seperate. 2

FIGURE 1 DOME REMOVAL Cable Assembly Rubber mounting washers (x4) Plastic anchors (x4) for drywall only. Mounting Screws (x4) Loosen (x3) Set Screws to remove trim ring and bubble. b) Using a minimum 1/2 drill bit, drill the cable feed hole and feed the video/power cable through the mounting surface or attach 3/4 conduit fitting to the hole in the side and seal with pipe thread tape (see FIGURE 2). FIGURE 2 BACK VIEW CONDUIT HOLE Built-in Conduit Hole FIGURE 3 INSIDE BASE MOUNTING HOLES Mounting holes for camera base (2) Mounting holes for housing, covered by rubber plugs (4) c) Holding the dome against the mounting surface, mark and drill the 4 mounting holes (see FIGURE 3). Fasten the base to the mounting surface using the supplied #8 Phillips screws, rubber washers and plastic anchors (anchors for dry wall only), (see FIGURE 1). Depending on the mounting surface other hardware may be needed. Add rubber gasket seal to the back of the housing for sealing on a flat surfaces. For uneven surfaces a bead of silicone sealant is recommended. Note: If using other mounting hardware; apply silicone sealant around the inside of the 4 mounting holes before inserting screws or bolts to prevent damage from leakage. 3

2) Install ZC-D5000 Series Dome Camera a) Remove the two camera mounting screws (see FIGURE 4). b) Place the camera base into the housing, making sure that the 6 power and video wires feed through the hole in the camera base. c) Rotate camera slightly to lock in place, then install 2 supplied mounting screws to secure camera to the housing base (see FIGURE 3 for locations). d) Make the wiring connections in accordance with the instructions below. FIGURE 4 Cable Assembly 3) Connect Power IMPORTANT Camera Mounting Screws (x2) Make wiring connections only after it has been determined that power has been disconnected. Failure to do so could lead to permanent damage to the camera and void the warranty.the ZC- D5000 Series Dome Cameras will accept either 12 Volts DC or 24 Volts AC power supply marked class 2. If using 12VDC, be sure to determine the polarity before connection. The Red wire connects to 12VDC (+) Positive terminal and the Black wire connects to the Ground terminal (see FIGURES 5 & 6).When using 12VDC, use only a regulated power supply with a minimum 500mA output, (model C12DCR-500 recommended). For 24VAC input, connect the Red and Black wires to the 2 power input terminals. FIGURE 5 12VDC ground or 24VAC (Black) Video Signal with 2-pin connector 12VDC positive or 24VAC (RED) 4

4) Connect Video Connect the White connector to the Video-Out Terminal on the board. (see FIGURE 5). Note: If necessary, needle nose pliers can be used to make power and video connections. FIGURE 6 RED BLACK WHITE GREEN BLUE BROWN 12VDC+ OR 24VAC 12VDC GROUND OR 24VAC VIDEO SIGNAL OUT VIDEO GROUND B/W FIX GROUND} OPTION For True Day/Night models only Note: Special focusing Instructions when using 5-50mm dome. If the 5-50mm lens is set to a focal length of 20mm or greater, the dome cover must be held in front of the lens while focusing to obtain proper focus. 5) Install the Desiccant Pack After the camera has been installed, attach the supplied desiccant pack to the camera. a) Remove the desiccant pack from its storage bag. b) Remove plastic from the double-sided tape and attach to the inside of camera bracket (see FIGURE 7).The desiccant pack is used to absorb any moisture trapped inside the dome during installation.to avoid excessive moisture buildup, it is recommended that the camera not be installed in rainy or excessively damp conditions.the desiccant pack can be replaced if condensation develops inside the housing. Replacement packs and other replacement parts are available through CBC (AMERICA) Corp. FIGURE 7 Attach desiccant pack here 5

6) Re-Install Dome Cover a) Place the dome cover on the housing base. b) Push the cover lightly onto the base, rotate the liner or dome cover to align with lens and tighten the 3 tamper resistant set screws (see FIGURE 1) until the cover seals tight against the housing base. CAUTION: Do Not Over Tighten! Changing the Polycarbonate Dome The ZC-OH5 housing is supplied with a clear dome and black plastic liner. If damaged, the dome can be replaced by removing the 4 flat head screws inside the dome cover. Due to a tight seal, some pressure may be required to the top of the dome to break the seal. After installing the new dome, replace the retaining ring and tighten the 4 flat head screws until the retaining ring is flush with the adjacent surface. MAINTENANCE NOTES If the housing cover is opened frequently or if the O-Ring dries out, apply a light coat of good quality silicone based grease to the O-Ring to maintain a watertight seal. Replacement O-rings and other replacement parts are available through CBC (AMERICA) Corp. OPTIONS 1. Pendant Mount A pendant mount adapter is available for applications that require the dome to be dropped from the ceiling from a pipe. The pendant mount adapter accepts a 1 NPT pipe thread (Model ZC5-PM2). 2. Wall Mount The wall mount combines the pendant mount with a wall mount bracket for various wall-mounting applications (Model ZC5-WM2). 3. Heater A 24VAC heater option is available. Contact CBC (AMERICA) Corp. for details and specifications. 4. Housing Color Different housing colors (either painted or anodized) are available for a minimum order lot and custom paint charge. 6

FIGURE 8 FIGURE 9 OPTIONAL PENDANT MOUNT OPTIONAL WALL MOUNT HOUSING SPECIFICATIONS Construction: Finish: Ratings: Dimensions: Unit Weight: Cast Aluminum, stainless steel hardware, polycarbonate dome. Off-White Powder Coat Paint Designed to meet NEMA 5, IP66 6.66 diameter, 4.95 overall height 2lb. 5oz. *Temp Range: +10 degrees to +140 degrees F without heater -25 to +140 degrees F with heater (ZC-D5000 Series Dome Cameras) *Temperature Range recommendations are based on proper installation and maintenance procedures outlined in this manual. Improper installation or maintenance may alter the camera s operational limits, damage the device and void the warranty. Design and product specifications subject to change without notice. 7

DIMENSIONAL OUTLINES ZC-OH5 1.81 [ 46] ø 6.66 [ 169,2] 3.26 [ 82,8] 4.95 [ 125,7] 2.73 [ 69,3 ] OPTIONAL PENDANT MOUNT OPTIONAL WALL MOUNT 11.82 [ 300,3 ] 6.07 [ 154,2] in mm 8.13 [ 206,4] 11.50 [ 292,1] Disposal of your old appliance 1.When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC. 2. All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. 3.The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health. 4. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. 100 0200 001 CBC 01/08 Data subject to change without notice. Printed in USA NEW YORK: 55 MALL DRIVE COMMACK, NY 11725 TEL 1-800-422-6707 631-864-9700 FAX 631-543-5426 CALIFORNIA: 20521 EARL STREET TORRANCE, CA 90503 TEL 1-800-888-0131 310-793-1500 FAX 310-793-1506 www.cbcamerica.com 2007 CBC America Corp., All Rights Reserved. 01/08