Dell Networking S4048-ON

Similar documents
Dell Networking S3048-ON

Dell EMC Networking S6010-ON

Dell Networking S6000

Dell Networking S60 and Dell Force10 S60

Dell Force10 S4810 Switch

Dell EMC Networking S4148-ON and S4128-ON

Dell Force10 S4810 Switch

Dell EMC Networking S4148-ON and S4128-ON

Dell Networking N4000 Series and Dell PowerConnect 8100 Series

Dell Networking N2000 Series

Arista 7050SX-96-F. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Cisco Nexus Switch Configuration Guide for Dell SC Series SANs. Dell Storage Engineering August 2015

Huawei CloudEngine 6850

Dell EMC Switch Configuration Guide for iscsi and Software-Defined Storage

Cisco Nexus 5648Q. Switch Configuration Guide for Dell PS Series SANs

Cisco Nexus 5648Q. Switch Configuration Guide for Dell EMC SC Series SANs

Cisco Nexus 9372PX. Switch Configuration Guide for Dell EMC SC Series SANs. A Dell EMC Deployment and Configuration Guide

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

Cisco Nexus 9372PX. Switch Configuration Guide for Dell PS Series SANs. A Dell EMC Deployment and Configuration Guide. Dell EMC Engineering June 2017

Huawei CloudEngine 6850

Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110

Dell EMC XC Series Networking Deployment and Best Practices Guide v2.0

17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S

A Dell Interoperability Whitepaper Victor Teeter

Best Practices for Mixed Speed Devices within a 10 Gb EqualLogic Storage Area Network Using PowerConnect 8100 Series Switches

Microsoft SharePoint Server 2013 on Dell PowerEdge R630 with Microsoft Hyper-V Virutalization Deployment Guide

Planning and Preparation Guide

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Best Practices for Configuring DCB with VMware ESXi 5.1 and Dell EqualLogic Storage

Deployment of Dell M8024-k Blade Switch in Simple Mode with Cisco Nexus 5k Switch

Dell PowerEdge FN I/O Aggregator. Command Line Reference Guide 9.8(0.0)

DEPLOYING A STACK OF DELL M-SERIES BLADE SWITCHES IN SIMPLE SWITCH MODE (SSM)

Switch Quick Configuration CLI Guide for

Dell EMC Ready Stack Deployment Guide for VMware vsphere and Unity

Configuring a Dell EqualLogic SAN Infrastructure with Virtual Link Trunking (VLT)

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Dell EMC Ready Bundle for Virtualization Deployment Guide for VMware vsan Infrastructure

Using Switches with a PS Series Group

Switch Quick Configuration CLI Guide for

Best Practices for Configuring Data Center Bridging with Windows Server and EqualLogic Storage Arrays

Dell PowerEdge Configuration Guide for the M I/O Aggregator 9.5(0.1)

Using Switches with a PS Series Group

Reference Architecture utilizing the PowerEdge M1000e Blade Enclosure, SQL Server and Exchange Server

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5

Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

Victor Teeter Network Enabled Solutions Team

Horizontal Stacking Software Configuration Guide for IE 5000 Switches

EqualLogic Storage and Non-Stacking Switches. Sizing and Configuration

Dell PowerEdge M1000e Blade Enclosure and Dell PS Series SAN Design Best Practices Using Dell S-Series and M-Series Networking

Dell PS Series DCB Configuration Best Practices

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.6

Switch Web GUI Quick Configuration Guide for

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

Lenovo ThinkSystem NE1032/NE1032T/NE1072T. Release Notes. For Lenovo Cloud Network Operating System 10.6

DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

Dell Active System 200 & 800

Networking in Active System 800. Dell Active System 800. And Network Architecture. Jaiwant Virk. Dell Force10 Product Management

Dell EMC Networking Deploying Data Center Bridging (DCB)

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Dell Compellent FS8600

Lenovo NE1032 and NE1032T Switch

Skills Assessment (EIGRP) Student Training Exam

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Configuring Interfaces

iscsi Boot from SAN with Dell PS Series

Configuring VLANs. Understanding VLANs CHAPTER

Dell EMC Ready Stack: VMware IaaS on PowerEdge MX Servers and PowerMax Storage

April Brocade VDX 6740 Deployment Guide for VMware EVO:RAIL

DCPPE-200.exam. Number: DCPPE-200 Passing Score: 800 Time Limit: 120 min File Version: DELL DCPPE-200

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Lab Configuring EtherChannel

Skills Assessment (OSPF) Student Training Exam

UCS deployment guide for Nimble Storage

Reference Architectures for designing and deploying Microsoft SQL Server Databases in Active System800 Platform

Configuring Interface Characteristics

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

Configuring VLANs. Understanding VLANs CHAPTER

Emulex Universal Multichannel

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Skills Assessment (OSPF) Student Training Exam

Skills Assessment (EIGRP) Student Training Exam

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage

Configuring System Port Profiles

Lenovo RackSwitch G8272. Release Notes. For Cloud Network Operating System 10.3

Stacking Dell Force10 MXL 10/40G Blade Switches

Configuring VLANs. Understanding VLANs CHAPTER

Configuring Interface Characteristics

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

February Connectrix VDX-6740B IP Storage Switch Deployment Guide for VxRail Appliance

Integrating EqualLogic PS6x10 Arrays with Existing SANs

Switch Configuration Example for Q-SYS Platform HP 1910 and HP 1920

Configuring Virtual Service Blades

Configuring EtherChannels and Link-State Tracking

Installing and Configuring VXLAN Gateway

Configuring Virtual Port Channels

DGS-3630-Series Switches

MR2324-4C. 24-Port Intelligent Gigabit Ethernet Switch. Management Guide

Transcription:

Dell Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering August 2015 A Dell Deployment and Configuration Guide

Revisions Date August 2015 Description Initial release THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. 2015 Dell Inc. All rights reserved. Dell, the DELL logo, and the DELL badge are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims any proprietary interest in the marks and names of others. 2 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

Table of contents Revisions... 2 1 Introduction... 5 1.1 Document conventions... 5 1.2 Audience... 5 1.3 Switch details... 5 1.4 Cabling diagram... 7 2 Dell recommended switch configuration... 8 2.1 Hardware configuration... 8 2.2 Delete startup configuration... 8 2.3 Configure out of band (OOB) management port... 8 2.4 Configure route for OOB management port (optional)... 9 2.5 Configure login credentials... 9 2.6 Enable switch ports... 9 2.7 Enable Jumbo Frames... 9 2.8 Configure flow control... 9 2.9 Configure spanning tree on edge ports... 10 2.10 Configure port channel for LAG... 10 2.11 Configure QSFP ports for LAG... 10 2.12 Save configuration... 10 2.13 Configure additional switch... 10 3 Configure Data Center Bridging (DCB) (optional)... 11 3.1 Disable 802.3x flowcontrol on SFP+ ports... 11 3.2 Disable 802.3x flowcontrol on QSFP ports... 11 3.3 Enable DCB and reload... 11 3.4 Create tagged VLAN for all ports and port-channels... 11 3.5 Configure DCB policies... 12 3.6 Apply policies to switch ports... 12 3.7 Save configuration... 12 3.8 Configure additional switch... 12 4 Reverting from DCB to non-dcb configuration (optional)... 13 4.1 Disable DCB... 13 3 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

4.2 Remove DCB policies and apply standard flow control... 13 4.3 Revert to default VLAN ID on switch and arrays... 13 4.4 Save configuration... 14 4.5 Reload... 14 4.6 Verify DCB status... 14 4.7 Configure additional switch... 14 5 Optional stack configuration... 15 5.1 Delete startup configuration on first switch... 15 5.2 Configure stack on the first switch... 15 5.3 Delete startup configuration on the second switch... 15 5.4 Configure stack on the second switch... 16 5.5 Verify stack configuration... 16 5.6 Configure out of band (OOB) management port... 16 5.7 Configure route for OOB management port (optional)... 17 5.8 Configure login credentials... 17 5.9 Configuring switch ports... 17 5.10 Save configuration and reload... 18 Additional resources... 19 4 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

1 Introduction This document illustrates how to configure Dell Networking S4048-ON switches for use with Dell PS Series storage while using Dell best practices. The recommended configuration uses Link Aggregation Groups (LAGs) for inter-switch connections. Optional steps are provided in section 3 to enable Data Center Bridging (DCB) and for stack configurations. If you are following the Rapid EqualLogic Configuration steps at http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portalby-sis.aspx, use sections 1 and 2, or 1 and 5 in this Switch Configuration Guide. For more information on PS Series SAN design recommendations, see the PS Series Configuration Guide at: www.delltechcenter.com/page/equallogic+configuration+guide. 1.1 Document conventions Table 1 lists the formatting conventions used in this document. Table 1 Document conventions Format Description Example Bold User input Dell>enable Italic Placeholder or variable your password <Italic> <brackets> Separate variables <ip address> <mask> 1.2 Audience This switch configuration guide describes an optimal configuration following Dell best practices for a PS Series iscsi SAN and is intended for storage or network administrators and deployment personnel. 1.3 Switch details Table 2 provides an overview of the switch configuration. Table 2 Switch specifications Dell Networking S4048-ON Switch vendor Switch model Switch firmware Dell S4048-ON 9.8.0.0 or later 5 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

Note: For proper functionality, the switch must be at the switch firmware version shown in Table 2 before proceeding with this configuration. Using previous firmware versions may have unpredictable results. The latest firmware updates and documentation can be found at: www.force10networks.com. This site requires a login. Note: Firmware version 9.8.0.0 incorporates new command-line syntax for DCB configuration. To configure a new switch for DCB operation, follow the configuration steps in this Switch Configuration Guide as outlined below. If you are upgrading from Dell firmware version prior to 9.8.0.0, your DCB settings in the running configuration file will be preserved and you may continue to use the original DCB command-line syntax. If you make changes using the previous DCB command-line syntax, you will receive a warning message that the commands have been deprecated, however the commands will still continue to function as they did with the previous version. 6 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

1.4 Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and PS Series arrays. Figure 1 Cabling diagram 7 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

2 Dell recommended switch configuration These steps show you how to configure two S4048-ON switches with a Link Aggregation Group (LAG). The switches are interconnected using two of the 40GbE Quad Small Form-factor Pluggable (QSFP) uplink ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP). 2.1 Hardware configuration 1. Power on the two switches. 2. Connect a serial cable to the serial port of the first switch. 3. Using PuTTY or another terminal utility, open a serial connection session to the switch. 4. Open your terminal emulator and configure it to use the serial port (usually COM1 but this may vary depending on your system). Configure serial communications for 115200,N,8,1 and no flow control. 5. Connect the (QSFP) LAG cables between the switches by connecting port 49 on switch 1 to port 49 on switch 2 and port 50 on switch 1 to port 50 on switch 2. See this configuration in Figure 1. 2.2 Delete startup configuration Note: The following commands will delete all configuration settings. Dell>enable Dell#delete startup-config Proceed to delete startup-config [confirm yes/no]yes Dell#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 2.3 Configure out of band (OOB) management port Dell>enable After the startup configuration is deleted, the factory default Enable mode password is calvin. Dell>#configure Dell(conf)#interface ManagementEthernet 1/1 Dell(conf-if-ma-1/1)#no shutdown Dell(conf-if-ma-1/1)#ip address <ip address> <mask> Dell(conf-if-ma-1/1)#exit 8 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

2.4 Configure route for OOB management port (optional) Dell(conf)#management route X.Y.Z.0 /24 A.B.C.1 Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for the switch. If your management system is on the same subnet as the switch, the previous step may be omitted. The previous example assumes a class C subnet mask. 2.5 Configure login credentials Dell(conf)#username admin privilege 15 password 0 yourpassword Dell(conf)#enable password level 15 0 yourpassword 2.6 Enable switch ports Option 1: Enable ports individually by entering the port number. Dell(conf)#interface tengigabitethernet 1/1 Dell(conf-if-te-1/1)#switchport Dell(conf-if-te-1/1)#no shutdown Dell(conf-if-te-1/1)#exit Option 2: Enable multiple ports at once using the range parameter. Dell#configure Dell(conf)#interface range tengigabitethernet 1/1 1/48 Dell(conf -if-range-te-1/1-48)#switchport Dell(conf -if-range-te-1/1-48)#no shutdown Dell(conf -if-range-te-1/1-48)#exit 2.7 Enable Jumbo Frames Dell#configure Dell(conf)# interface range tengigabitethernet 1/1 48 Dell(conf -if-range-te-1/1-48)#mtu 12000 2.8 Configure flow control Dell(conf -if-range-te-1/1-48)#flowcontrol rx on tx off 9 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

2.9 Configure spanning tree on edge ports Dell(conf-if-range-te-1/1-48)#spanning-tree rstp edge-port Dell(conf-if-range-te-1/1-48)#exit Dell(conf)# protocol spanning-tree rstp Dell(conf-rstp)#no disable Dell(conf-rstp)#exit 2.10 Configure port channel for LAG These commands configure the switch interconnect as a LAG. Dell(conf)#interface Port-channel 1 Dell(conf-if-po-1)#mtu 12000 Dell(conf-if-po-1)#switchport Dell(conf-if-po-1)#no shutdown Dell(conf-if-po-1)#exit 2.11 Configure QSFP ports for LAG These commands assign 40Gb QSFP ports to the Port Channel. Dell(conf)#interface range fortygige 1/49, fortygige 1/50 Dell(conf-if-range-fo-1/49,fo-1/50)#no ip address Dell(conf-if-range-fo-1/49,fo-1/50)#mtu 12000 Dell(conf-if-range-te-1/49,fo-1/50)#no shutdown Dell(conf-if-range-fo-1/49,fo-1/50)#flowcontrol rx on tx off Dell(conf-if-range-fo-1/49,fo-1/50)#port-channel-protocol lacp Dell(conf-if-range-fo-1/49,fo-1/50-lacp)#port-channel 1 mode active Dell(conf-if-range-fo-1/49,fo-1/50-lacp)#exit Dell(conf-if-range-fo-1/49,fo-1/50)#exit 2.12 Save configuration Dell#copy running-config startup-config 2.13 Configure additional switch Repeat the commands from sections 2.2 2.13 to configure the second switch. Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. 10 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

3 Configure Data Center Bridging (DCB) (optional) To enable DCB mode on the switch, use the following commands. Note: You must complete the Dell recommended switch configuration steps in Sections 2.1 to 2.12 before configuring the switch for DCB mode. 3.1 Disable 802.3x flowcontrol on SFP+ ports Dell#configure Dell(conf)#interface range tengigabitethernet 1/1 1/48 Dell(conf-if-range-te-1/1-48)#no flowcontrol rx on tx off Dell(conf-if-range-te-1/1-48)#exit 3.2 Disable 802.3x flowcontrol on QSFP ports Dell(conf)#interface range fortygige 1/49, fortygige 1/50 Dell(conf-if-range-fo-1/49-50)#no flowcontrol rx on tx off Dell(conf-if-range-fo-1/49-50)#exit 3.3 Enable DCB and reload Dell(conf)#dcb enable Dell#copy running-config startup-config Dell#reload Note: After confirming reload request, the switch will reboot. 3.4 Create tagged VLAN for all ports and port-channels Dell#configure Dell(conf)#interface vlan vlan-id Note: You must supply a VLAN id. The valid range is 2-4093. Dell (conf-if-vl-vlan-id*)#no shutdown Dell (conf-if-vl-vlan-id*)#tagged tengigabitethernet 1/1 1/48 Dell (conf-if-vl-vlan-id*)#tagged port-channel 1 Dell (conf-if-vl-vlan-id*)#exit 11 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

3.5 Configure DCB policies Dell(conf)#dcb-map profile-name Dell(conf-dcbmap-profile-name*)#priority-group 0 bandwidth 50 pfc off Dell(conf-dcbmap-profile-name*)#priority-group 1 bandwidth 50 pfc on Note: The sum of the bandwidth-percentages must be equal to 100. Dell(conf-dcbmap-profile-name*)#priority-pgid 0 0 0 0 1 0 0 0 Dell(conf-dcb-profile-name*)#exit 3.6 Apply policies to switch ports Dell(conf)#interface range tengigabitethernet 1/1 1/48 Dell(conf-if-range-te-1/1-48)# dcb-map profile-name Dell(conf-if-range-te-1/1-48)#exit Dell(conf)#interface range fortygige 1/49, fortygige 1/50 Dell(conf-if-range-fo-1/49,fo-1/50)# dcb-map profile-name Dell(conf-if-range-fo-1/49,fo-1/50)#exit Note: The sum of the bandwidth-percentages must be equal to 100. 3.7 Save configuration Dell#copy running-config startup-config 3.8 Configure additional switch Repeat the commands from section 3 to configure DCB on additional switches. 12 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

4 Reverting from DCB to non-dcb configuration (optional) One method to revert from a DCB-configured switch to a non-dcb-configured switch is to delete the current configuration (startup-config) and follow the steps in section 2. If deleting the current configuration is not an option, use the following procedure to unconfigure DCB and enable standard flow control. Note: This is a disruptive operation that requires down time. The arrays will temporarily lose communication with each other. Power off all arrays and hosts connected to the SAN before proceeding with these steps. 4.1 Disable DCB Dell#configure Dell(conf)#no dcb enable 4.2 Remove DCB policies and apply standard flow control Dell#configure Dell(conf)#interface range tengigabitethernet 1/1-48 Dell(conf-if-range-te-1/1-1/48)#no dcb-map profile-name Dell(conf-if-range-te-1/1-48)#flowcontrol rx on tx off Dell(conf-if-range-te-1/1-48)#exit Dell(conf)#interface range fortygige 1/49, fortygige 1/50 Dell(conf-if-range-fo-1/49,fo-1/50)#no dcb-map profile-name Dell(conf-if-range-fo-1/49,fo-1/50)#flowcontrol rx on tx off Dell(conf-if-range-fo-1/49,fo-1/50)#exit 4.3 Revert to default VLAN ID on switch and arrays Once DCB is disabled on the switch, the PS Series arrays will no longer use the VLAN ID that was configured when DCB was enabled. The arrays will revert to the default or native VLAN. Therefore, a valid VLAN must be configured for all host servers, switches, and PS Series array members. A valid VLAN can use the default or native VLAN ID (typically 0 or 1), or a specific VLAN can be configured (for example, VLAN 100). If a non-default VLAN is configured, then any ports connected to the arrays must be configured as untagged. Note: Host NICS must also be updated with matching VLAN information. 13 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

Use the following steps to configure the native VLAN on the switch. Dell#configure Dell(conf)#no interface vlan vlan-id 4.4 Save configuration Dell#copy running-config startup-config 4.5 Reload Dell#reload System configuration has been modified. Save? [yes/no]yes Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 4.6 Verify DCB status Dell#show dcb The following status is displayed: DCB Status : Disabled 4.7 Configure additional switch Repeat the commands from section 4 to disable DCB on any additional switches. 14 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

5 Optional stack configuration Note: If you wish to use a stack configuration instead of LAG, follow the instructions in this section instead of those in section 2. One advantage of stacked switches is that they can be managed as a single switch. However, firmware updates will update all members of the stack simultaneously and therefore should only be done during planned downtime. 5.1 Delete startup configuration on first switch Dell>enable Dell#delete startup-config Proceed to delete startup-config [confirm yes/no]yes Dell#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 5.2 Configure stack on the first switch Dell>enable After the startup configuration is deleted, the factory default Enable mode password is calvin. Dell#configure Dell(conf)#stack-unit 1 priority 1 Dell(conf)#stack-unit 1 stack-group 12 Dell(conf)#stack-unit 1 stack-group 13 Dell#copy running-config startup-config Dell#reload 5.3 Delete startup configuration on the second switch Dell>enable Dell#delete startup-config Proceed to delete startup-config [confirm yes/no]yes Dell#reload 15 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 5.4 Configure stack on the second switch Dell>enable Dell#stack-unit 1 renumber 2 Note: After confiming configuration change, the switch will need to reboot. Dell#configure Dell(conf)#stack-unit 2 priority 1 Dell(conf)#stack-unit 2 stack-group 12 Dell(conf)#stack-unit 2 stack-group 13 Dell#copy running-config startup-config Dell#reload 5.5 Verify stack configuration From the first switch (Master) CLI, confirm that the stack has formed: Dell#show redundancy Dell#show boot system stack-unit all Note: The MASTER LED on the switch front panel will show a steady light for the master unit and a blinking light for the standby unit. All of the following configuration steps must be performed from the master switch. 5.6 Configure out of band (OOB) management port Dell#config Dell(conf)#interface ManagementEthernet 1/1 Dell(conf-if-ma-1/1)#no shutdown Dell(conf-if-ma-1/1)#ip address ipaddress mask Dell(conf-if-ma-1/1)#no shutdown Dell(conf-if-ma-1/1)#exit 16 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

5.7 Configure route for OOB management port (optional) Dell(conf)#management route X.Y.Z.0 /24 A.B.C.1 Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for the switch. If your management system is on the same subnet as the switch, the previous step may be omitted. The previous example assumes a class C subnet mask. 5.8 Configure login credentials Dell(conf)#username admin privilege 15 password 0 yourpassword Dell(conf)#enable password level 15 0 yourpassword 5.9 Configuring switch ports Dell(conf)#interface range tengigabitethernet 1/1 1/48 Dell(conf-if-range-te-1/1-48)#mtu 12000 Dell(conf-if-range-te-1/1-48)#switchport Dell(conf-if-range-te-1/1-48)#spanning-tree rstp edge-port Dell(conf-if-range-te-1/1-48)#flowcontrol rx on tx off Dell(conf-if-range-te-1/1-48)#no shutdown Dell(conf-if-range-te-1/1-48)#exit Dell(conf)#interface range tengigabitethernet 2/1 2/48 Dell(conf-if-range-te-2/1-2/48)#mtu 12000 Dell(conf-if-range-te-2/1-2/48)#switchport Dell(conf-if-range-te-2/1-2/48)#spanning-tree rstp edge-port Dell(conf-if-range-te-2/1-2/48)#flowcontrol rx on tx off Dell(conf-if-range-te-2/1-2/48)#no shut Dell(conf-if-range-te-2/1-2/48)#exit Dell(conf)# protocol spanning-tree rstp Dell(conf-rstp)#no disable Dell(conf-rstp)#exit 17 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

5.10 Save configuration and reload Dell#copy running-config startup-config Reload the stack to allow settings to take effect: Dell#reload Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. 18 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs

Additional resources Support.Dell.com is focused on meeting your needs with proven services and support. DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: PS Series Configuration Guide: http://en.community.dell.com/techcenter/storage/w/wiki/equallogic-configuration-guide.aspx Dell Storage Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/20438558/download.aspx For PS Series best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to: http://en.community.dell.com/techcenter/storage/w/wiki/2660.equallogic-technical-content 19 SCG1026 Dell Networking S4048-ON Switch Configuration Guide for PS Series SANs