Power Factor Model Number Voltage Voltage

Efficiency (1) 110Vac 220Vac

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

Max. Output Power. Typical Efficiency (1) 350 ma 90 ~ 305 Vac 107~214Vdc 75 W 92% EUC-075S035DT(3)

Typical Efficiency (2) 0 ~ 12.5 A 150 W 90.0% EUV-150S012DTA(STA) 0 ~ 6.25 A 150 W 90.5% EUV-150S024DTA(STA) (4)

Efficiency (1) 110Vac 220Vac

Max. Output Power. Typical Efficiency (1) 12 Vdc 249~ 528 Vac 0~10 A 120 W 91.5% ESV-150S012ST

Output Voltage Range. Parameter Min. Typ. Max. Notes. Leakage Current ma IEC ; 240Vac/ 60Hz

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST) (3 ) Parameter Min. Typ. Max. Notes

Typical Efficiency (2) 500 ma 90 ~ 305 Vac 32~64 Vdc 32 W 87.0% EUC-035S070SVM0004

Typical Efficiency (2) Max. Output Power. 700 ma 140 ~ 305 Vac 107 ~ 214 Vdc 150 W 92.0% 0.96 EDC-150S105SV-0007

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~250 Vdc

Constant Voltage Mode

Output Voltage Range. Max. Output Power

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~250 Vdc. Leakage Current ma IEC ; 240Vac/ 60Hz

Typical Efficiency (2) Max. Output Power ma 176 ~ 305 Vac 260~400Vdc 420 W 94.0% 0.95 EBC-420S105DV(SV)

Typical Efficiency (2) Max. Output Power. 700 ma 160~305 Vac 30~60 Vdc 42 W 88% 0.95 EBC-042S105DV(SV)-0007

Output Voltage Range. Max. Output Power. (4) 90~305 Vac 127~300 Vdc 16~78 Vdc 60 W 90% LUD-060S110BS2

Feature Ultra High Efficiency (Up to 94%)

240W Six-channel Constant Current IP67 Driver

Output Voltage Range. Max. Output Power. (4) 90~305 Vac 127~300 Vdc 8 ~54 Vdc 40 W 89.5% LUD-040S150BSF

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 97~214 Vdc 150 W 93.0% 0.98 EBD-150S105DVA

Max. Output Power. Typical Efficiency (2) 143~286Vdc 200 W 93.5% EUD-200S070GV. 95~190Vdc 200 W 93.5%

Output Voltage Range. Max. Output Power ma ma 700 ma 176~305 Vac 43~107 Vdc 75 W 90.5% 0.98 EBD-075S105DV

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 155~343 Vdc 240 W 94.0% 0.98 EBD-240S105DV

Output Voltage Range. Max. Output Power

Output Voltage Range. Max. Output Power

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS

H HOLUX Kft. H-1135 Budapest, Béke u Tel: (06 1) Fax: (06 1)

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Safety Standards. Model Number: Unit Weight:

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Features. Applications and Benefits TRC ELECTRONICS, INC

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Safety Standards. Model Number:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Gelo LED Driver 100W, Single output RGLD100-24

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

12-15VDC (12V±5%) 24-28VDC (24V±5%)

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Output Voltage in Constant Voltage Mode. Model Number

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

Enclosed Power Supplies

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

60 Watt Medical (MWLT)

SAMSUNG ELECTRO-MECHANICS CO., LTD

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Safety Standards. Model Number:

030AAC Highlights & Features

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

IEC/EN/UL60950 & CE certified, EN55032 Class B

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Universal input VAC <150mW No load power consumption

DDR-120 series. 120W DIN Rail Type DC-DC Converter

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

VP ELECTRONIQUE MASSY - Tel

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Universal Power Supplies

Output Voltage* (nom.)(adjustable)

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

SPECIFICATIONS: PSAK650

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

7.5 Watt AC-DC Switch Power Supply

12W AC/DC interchangeable Adapter MU012-HA Series

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

5W AC/DC interchangeable Adapter MU005-HA Series

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

Inventronics LED Driver 0 10V DMX RDM

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Voltage Current Front-mounting bracket

Transcription:

HEC100RTN48QSCA Rev A1.0 A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case with IP67 and damp/ wet location. B. Description The HEC100RTN48QSCA Series operate from a 90 ~ 305Vac input range. They are designed to be highly efficient and highly reliable. Features include over voltage protection, short circuit protection, and over temperature protection. C. Models Input Voltage Range Output Voltage Range Note 1 Note 4 90 ~ 305Vac 2448V Output Current 2100mA Max. Output Power Efficiency Power Factor Note 2 Note 2 100 W 90% 0.96 Model Number HEC100RTN48QSCA D. Electronic Specifications Input Specifications Parameter Min. Typ. Max. Input Voltage (V) 90 305 Input Frequency (Hz) 47 Notes 63 1.5 Measured at full load and 100Vac input. 0.5 Measured at full load and 277Vac input. Leakage Current (ma) 0.7 At 277Vac 60Hz input. Inrush Current (A) 40 0.16 A2s At 220Vac input 25 C Cold Start. Duration=100µs, 10%Ipk10%Ipk. 0.9 20 25 Input AC Current (A) Inrush Current (I2t) Power Factor At 277Vac input, full load. THD (%) http://www.hecgroup.com.tw/ service@hecgroup.com.tw TEL:+88663560606 FAX:+88663560505 1

Output Specifications HEC100RTN48QSCA Rev A1.0 Output Current (ma) Io = 2100 ma 1995 2205 No Load Output Voltage (V) Io = 2100 ma Output Ripple Voltage (V) 63 1% Vo max Output Voltage Overshoot (%) 110 At full load condition. Line Regulation (%) ±3 Load Regulation (%) ±5 Turnon Delay Time (s) 0.5 1.0 Measured at 220Vac input. There will be no damage or hazardous conditions occurred with no loading. Measured by 20 MHz bandwidth oscilloscopes and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor. General Specifications Efficiency (%) Io = 2100 ma Efficiency (%) Io = 2100 ma MTBF (hours) 320,000 Life Time (hours) 100,000 Case Temperature ( C) 85 Dimensions Millimeters(L W H) 70*ψ130 88 90 Measured at full load and 120Vac input. Measured at full load and 277Vac input. Measured at full load 50 C ambient temperature (MILHDBK217F). Measured at rated input voltage with full load, Case temperature=60 C @ Tc point.see life time vs. Tc curve for the details. Protection Functions Over Voltage Protection 1.50 Vomax In the event of an overvoltage condition, the LED Drives shall Shut down o/p voltage, repower on to recover. Over Temperature Protection Short Circuit Protection Shut down o/p voltage with repower on to recovery. No damage shall occur when any output operating in a short circuit condition. The power supply shall be selfrecovery when the fault condition is removed. http://www.hecgroup.com.tw/ service@hecgroup.com.tw TEL:+88663560606 FAX:+88663560505 2

HEC100RTN48QSCA Rev A1.0 Environmental Specifications Operating Temperature ( C) 40 +70 Humidity: 20% RH to 80% RH; See Derating Curve for more details. Storage Temperature ( C) 40 +80 Humidity: 10% RH to 90% RH. Safety and EMC Compliance Safety Category Standard UL/CUL UL8750, UL 1012, CSA C22.2 No. 107.1 CE EMI Standards EN 55015 EN 6100032 EN 6100033 FCC Part 15 EMS Standards EN 6100042 EN 6100043 EN 613471, EN61347213. Notes Conducted emission Test & Radiated emission Test. Harmonic current emissions. Voltage fluctuations & flicker. FCC 47 CFR Part 15 Subpart B, ICES003 Issue 4 ANSI C63.42003 Notes Electrostatic Discharge (ESD): 8 KV air discharge, 4 KV contact discharge. RadioFrequency Electromagnetic Field Susceptibility TestRS. EN 6100044 Electrical Fast Transient / BurstEFT: Level 2, Criteria A. EN 6100045 EN 6100046 EN 6100048 EN 61000411 EN 61547 Surge Immunity Test: AC Power Line: line to line 2 KV. line to group 4 KV. Conducted Radio Frequency Disturbances TestCS. Power Frequency Magnetic Field Test. Voltage Dips. Electromagnetic Immunity Requirements Applies To Lighting Equipment. Notes: 1. Normal input voltage range 100~277Vac. 2. Measured at input 220V with a full load. 3. All specifications are typical at 25 C unless otherwise stated. 4. Constant current operation region is preferably 50%~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static curve for more details. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must requalify EMC Directive on the complete installation again http://www.hecgroup.com.tw/ service@hecgroup.com.tw TEL:+88663560606 FAX:+88663560505 3

HEC100RTN48QSCA Rev A1.0 E. Electronic Curve Derating Curve Static Curve Power Factor Characteristics Curve Efficiency Characteristics Curve http://www.hecgroup.com.tw/ service@hecgroup.com.tw TEL:+88663560606 FAX:+88663560505 4

HEC100RTN48QSCA Rev A1.0 Life Time vs. Case Temperature Curve F. Mechanical Outline http://www.hecgroup.com.tw/ service@hecgroup.com.tw TEL:+88663560606 FAX:+88663560505 5

HEC100RTN48QSCA Rev A1.0 G. RoHS Compliance Outline Our products comply with the European Directive 2011/65/EU, calling for the elimination of lead and other hazardous substances from electronic products. H. Revision History Change Date Rev. Description of Change Item From To 20141208 A1.0 Revised Static Curve / / http://www.hecgroup.com.tw/ service@hecgroup.com.tw TEL:+88663560606 FAX:+88663560505 6