Spacing Requirements for Power Distribution and Terminal Blocks

Similar documents
Equipment Short-Circuit Current Rating and Available Fault Current

UL 508A Industrial Control Panels Eaton. All Rights Reserved.

Electrical Service Change-Tn Neenah

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Short Circuit Current Ratings and AC Drives

UL 508 A standard-compliant design of industrial control panel

SERIES RATED COMBINATIONS

BSPD Surge Protective Devices

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

Requirements for machine approval in North America under the new NEC 2017

920 Remote Control (RC) Switches

UL508Afor Panel Builders Getting Started

ASCO 920 Remote Control (RC) Switches

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

Application Techniques CENTERLINE 2100 Motor Control Centers

Electrical Plan Review

Panelboard and switchboards series rating information manual

UL 489 or UL 1077 in control panels and equipment a quick guide

Circuit Protection Methods

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

SECTION DISTRIBUTION SWITCHBOARDS

Applying branch circuit breakers and supplementary protectors in North America

1. Coordination of series-rated devices is permitted where indicated on Drawings.

Remote contact signaling available. visual status indication

SECTION PANELBOARDS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

Applying branch circuit breakers and supplementary protectors in North America

2008 Code Changes for Power Distribution

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

White Paper October 2009

Electrical Components and Equipment for General Use Self Inspection Checklist

GUIDE TO VERIFYING SURGE PROTECTIVE DEVICES INSTALLED IN LIGHTNING PROTECTION SYSTEM INSTALLATIONS ARE COMPLIANT WITH UL 96A.

Spring Test 16 due 06/14/2013

2014 NEC Code Changes. Code changes based on the 2014 NEC

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Panelboard and switchboard series rating information manual

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Model volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL

JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B. R-Rated Fuses For Motor Circuit Protection Medium Voltage.

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

INTRODUCTION TO SPECIFYING SURGE PROTECTION SURGE PROTECTION NOTE 1 INTRODUCTION TERMS PROBABILITY OF SURGES APPEARING:

Want to make your inspectors happy?

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

BUSSMANN. North American UL Type 1, 2 and 4, and data signal surge protective devices SERIES. Application note 3193

TeSys IEC Contactors and Overload Relays

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Stalking the Elusive and Somewhat Strange PV System

60103 Circuit Breaker

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Ferraz Shawmut TPMOV Principles and Operation

SECTION SURGE PROTECTIVE DEVICES

How to select a terminal block

Spring Test 13 due 06/14/2013

Industrial Control Panels Tested product combinations to meet NEC Article 409 and UL 508A Standard

2014 AFCI code compliant safety. Understanding the 2014 NEC. for AFCI protection

Secondary Surge Arrester Instruction Manual Page 1 of 5

More Questions from Inspectors Numerous PV Systems Pose Issues

Catalog Number Identification with Elements Explained V V V V X 347 V Hz


Mitigating Arc Flash Hazards

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

Spring Test 9 due 05/11/2013

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Why is my AFCI tripping?

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

C E R T I F I C A T E O F C O M P L I A N C E

White Paper. UL Standards for Power Control System Equipment

Overcurrent and Overvoltage Protection Changes in the 2008 NEC Code. www. ElectricalPartManuals. com

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Surge Protection Device Systems

Please use the Q & A utility to ask us any questions concerning the material being presented.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

C E R T I F I C A T E O F C O M P L I A N C E

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Eaton s SPD Series for integration into electrical distribution equipment

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

The protection you rely on

White Paper Surge Protective Devices in Automatic Transfer Switches

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

CU port USB 2.0 hub. Version: 1.1 Date:

WMS SUPPLEMENTARY PROTECTORS

Surge Protection Device Systems

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

Transcription:

Spacing Requirements for Power Distribution and Terminal Blocks

New requirements in the 2005 NEC for a marked short-circuit current rating on industrial control panels, industrial machinery, and commercial/industrial HVAC equipment have resulted in considerable attention being placed upon the proper selection and application of Power Distribution Blocks (PDBs). It is fairly well understood that if an assembly short-circuit current rating above 10,000 amperes is desired, a Power Distribution Block or a Terminal Block with a high short-circuit current rating must be utilized. However, there is great confusion concerning the spacing requirements of these devices. This paper focuses on proper applications, based upon these spacing requirements. Proper Application When applying Power Distribution Blocks (PDBs), there are various requirements that shall be satisfied, based upon different UL Standards, the NEC, and the specific application. Some of the requirements and ratings include: voltage, continuous current, wire range (load and line side), short-circuit current rating or withstand rating (SCCR), type of upstream overcurrent protective device (fuse or circuit breaker) and spacing (between uninsulated live part and uninsulated grounded part or uninsulated live parts of opposite polarity). The requirements vary based on the application for industrial control panels (feeder circuit or branch circuit), field applications, or HVAC applications. PDB Spacing Requirements for Equipment: Depending upon the specific application and the standard to which the equipment is being designed, there are certain PDBs that can meet these spacing requirements, some with a high SCCR. The table below details the spacing requirements at 600V based upon the equipment standards. Spacing between Spacing between live parts of live parts and UL Standard opposite polarity grounded parts Through air Over surface or enclosure @600V @600V @600V 508A Branch Circuits 3 8 1 2 1 2 508A Feeder Circuits 1 2 1 1995 HVAC 3 8 1 2 1 2 Note: Refer to Specific UL standards for complete spacing details. UL1953 vs. UL1059 Most power distribution blocks available today are actually terminal blocks, and are recognized to UL 1059, the Terminal Block standard. Terminal blocks may or may not meet the spacing needed for OEM applications. Terminal blocks are marked with a UL recognition mark to ensure that the UL inspector checks, among other things, to make sure there is adequate spacing for the OEM application in which they are being applied. Power Distribution blocks are evaluated to UL1953, the Power Distribution Block standard and are listed for general installation, meaning they have adequate spacing for most OEM and field applications. These Power Distribution Blocks are marked with a listing mark, which means that the inspector does not need to check conditions of acceptability as would be needed with recognized products. As listed products, they are suitable for use in the field. For example, an electrical contractor may install them in a wireway, something that could not be done with a recognized product such as a terminal block. Industrial Control Panels (UL508A): UL508A contains two important requirements to consider when applying power distribution blocks. Spacing of 1 through air, 2 over surface (at 600V) is required when used in a feeder circuit (that s everything ahead of or on the line side of the final branch circuit overcurrent protective device). An assumed short-circuit current rating of 10kA for blocks not marked with a higher short-circuit current rating, per UL508A Table SB4.1. The following details the requirements regarding the use of power distribution blocks in industrial control panels. Use of Power Distribution Blocks in Industrial Control Panel Feeder Circuits A Listed PDB (UL1953) can be used as is since it meets the 2 and 1 spacing requirements for feeder circuits in UL508A section 10.2 (see table 10.2) & 28.2.4. A Recognized Terminal Blocks (UL1059) can only be used if it meets the spacing requirements in 10.2 & 28.2.1 (see Table 10.1) and it is suitable for field wiring (use Group A, C or D of UL 1059). Use Group A: Service including dead-front switchboards, panelboards, service equipment, and the like. Use Group B: Commercial appliances, including business equipment, electronic data processing equipment, and the like. Use Group C: Industrial, general. Use Group D: Industrial, devices having limited ratings. Such as where the load on any single circuit of the terminal block does not exceed 15 amperes at 51 150 volts, 10 amperes at 151 300 volts, 5 amperes at 301 600 volts, or the maximum ampere rating, whichever is less. Listed PDBs have adequate spacing for feeder circuit applications but most recognized terminal blocks don t have the spacing required for use in feeder circuits 2

Use of Power Distribution Blocks in Industrial Control Panel Branch Circuits A Listed PDB (UL1953) can be used as is since it exceeds the spacing requirements for branch circuits in UL508A section 10.2 (see table 10.1) & 28.2.4. A Recognized Terminal Block (UL1059) can only be used if it meets the spacing requirements at the required voltage in UL 508A, section 10.2 & 28.2.1 (see Table 10.1) and it is suitable for field wiring (Use Group A, C or D of UL 1059). Listed PDBs have adequate spacing for branch circuit applications and most recognized PDBs are also adequate for branch circuit applications Power Distribution Block Application Examples UL 508A HVAC Equipment (UL1995): The larger spacing that is mandated in UL508A is not present in UL1995. However, HVAC equipment utilizes control panels that are UL Listed 508A control panels. If the control panel for the HVAC equipment is a listed UL508A panel, the larger UL508A spacing is required. NEW 2005 NEC Requirements For Wireways: Listed power distribution blocks can be used to meet the new 2005 NEC requirement in section 376.56(B) for wireways. Since terminal blocks are recognized products to UL1059, they are not allowed for use for field wiring in metal wireways NATIONAL ELECTRICAL CODE : 376.56(B) Power Distribution Blocks. (1) Installation. Power distribution blocks installed in metal wireways shall be listed. (4) Live Parts. Power distribution blocks shall not have exposed live parts in the wireway after installation. The NEC now requires a PDB listed to UL 1953, equipped with a cover to prevent exposure of live parts when installed in metal wireway Power Distribution Block Application Examples UL 1995 and NEC 376.56(B) PDB in UL 508A, 480V Feeder Circuit must have spacing of 1 through air and 2 over surface. PDBs listed to UL 1953 meet these spacing requirements. Terminal Blocks recognized to UL1059 must be verified to have required spacing. PDB in 480V UL 1995 HVAC Equipment must have spacing of 3 8 through air and 1 2 over surface. PDBs listed to UL 1953 meet this spacing as well as most terminal blocks recognized to UL 1059. PDB in UL508A, 480V Branch Circuit must have spacing of 3 8 through air and 1 2 over surface. PDBs listed to UL 1953 meet these spacing as well as most terminal blocks recognized to UL 1059. 3

PDBs installed in wireways must be listed to UL1953 and provided with a cover per NEC 376.56(B). Terminal blocks recognized to UL1059 are not permitted because they are recognized, not listed. Note: Marking the equipment with its short-circuit current rating (SCCR) is another important consideration in the proper application of PDBs. Cooper Bussmann has a new line of PDBs with high short-circuit current ratings which makes it easier to achieve a high short-circuit current rating for the entire assembly, see the new Cooper Bussmann PDBs with High SCCR Datasheet (Reorder #3134). For more information on the topic of SCCRs for industrial control panels, see the new Cooper Bussmann Simplified Guide to Understanding Short-Circuit Current Rating (Reorder #7009). For more information or questions, please contact Cooper Bussmann Application Engineering at (636) 527-1270 or fusetech@cooperbussmann.com. Also visit us on the web at cooperbussmann.com. UL 1953 LISTED HIGH SCCR POWER DISTRIBUTION BLOCK APPLICATION CHART @ 600V Cooper Bussmann Part Number Description Max OCPD SCCR (ka) UL 508A Branch Circuit UL 508A Feeder Circuit UL 1995 NEC 376.56(B) PDB204-3 Line 2/0-8 Cu, Load 2/0-8 Cu, 3 Pole 200A Class J, T, CC or G 200 YES YES YES YES* PDB220-3 Line 2/0-8 Cu, Load (4) 4-12 Cu, 3 Pole 200A Class J, T, CC or G 200 YES YES YES YES* PDB220-3 Line 2/0-8 Cu, Load (4) 4-14 Cu, 3 Pole 175A Class J, T, CC or G 100 YES YES YES YES* PDB280-3 Line 2/0-8 Cu, Load 1/4-20 X 3/4 STUD, 3 Pole 200A Class J, T, CC or G 200 YES YES YES YES* PDB321-1 Line 2/0-8 Cu, Load (6) 4-12 Cu, 1 Pole 400A Class J, T, CC or G 200 YES YES YES YES* PDB321-1 Line 2/0-8 Cu, Load (6) 4-14 Cu, 1 Pole 175A Class J, T, CC or G 100 YES YES YES YES* PDB321-2 Line 2/0-8 Cu, Load (6) 4-12 Cu, 2 Pole 400A Class J, T, CC or G 200 YES YES YES YES* PDB321-2 Line 2/0-8 Cu, Load (6) 4-14 Cu, 2 Pole 175A Class J, T, CC or G 100 YES YES YES YES* PDB321-3 Line 2/0-8 Cu, Load (6) 4-12 Cu, 3 Pole 400A Class J, T, CC or G 200 YES YES YES YES* PDB321-3 Line 2/0-8 Cu, Load (6) 4-14 Cu, 3 Pole 175A Class J, T, CC or G 100 YES YES YES YES* PDB323-3 Line 350-4 Cu, Load (6) 4-8 Cu, 3 Pole 400A Class J, T, CC or G 200 YES YES YES YES* PDB323-3 Line 350-4 Cu, Load (6) 4-12 Cu, 3 Pole 175A Class J, T, CC or G 100 YES YES YES YES* PDB370-3 Line 350-4 Cu, Load (12) 4-8 Cu, 3 Pole 400A Class J, T, CC or G 200 YES YES YES YES* PDB370-3 Line 350-4 Cu, Load (12) 4-14 Cu, 3 Pole 175A Class J, T, CC or G 100 YES YES YES YES* PDB371-3 Line 350-4 Cu, Load (6) 2-6 Cu and (3) 1/0-6 Cu, 3 Pole 400A Class J, T, CC or G 200 YES YES YES YES* PDB371-3 Line 350-4 Cu, Load (9) 2-12 Cu, 3 Pole 175A Class J, T, CC or G 100 YES YES YES YES* *Optional covers required. For PDB204-1, -3, PDB220-1, -3, and PDB280-1, -3, Use CPB162-1 (One cover required per pole). For PDB321-1, -2, -3, Use CPB-1, -2, -3. For PDB323-1, -3, PDB370-1, -3, PDB371-1, -3, use CPDB-1 (One cover required per pole). 4

UL 1059 Recognized High SCCR Power Terminal Block Application Chart @ 600V Cooper UL 508A UL 508A Bussmann Branch Feeder UL NEC Part Number Description Max OCPD SCCR (ka) Circuit Circuit 1995 376.56(B) 14002-2UL Line 2-14Cu, Load 2-8 Cu, 2-Pole 200A Class J, T, CC or G 200 YES NO YES NO 14002-2UL Line 2-14Cu, Load 2-14 Cu, 2-Pole 175A Class J, T, CC or G 100 YES NO YES NO 14002-3UL Line 2-14Cu, Load 2-8 Cu, 3-Pole 200A Class J, T, CC or G 200 YES NO YES NO 14002-3UL Line 2-14Cu, Load 2-14 Cu, 3-Pole 175A Class J, T, CC or G 100 YES NO YES NO 14002-4UL Line 2-14Cu, Load 2-8 Cu, 4-Pole 200A Class J, T, CC or G 200 YES NO YES NO 14002-4UL Line 2-14Cu, Load 2-14 Cu, 4-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16204-1 Line 2/0-8 Cu, Load 2/0-8 Cu, 1-Pole 200A Class J, T, CC or G 200 YES NO* YES NO 16204-2 Line 2/0-8 Cu, Load 2/0-8 Cu, 2-Pole 200A Class J, T, CC or G 200 YES NO YES NO 16204-3 Line 2/0-8 Cu, Load 2/0-8 Cu, 3-Pole 200A Class J, T, CC or G 200 YES NO YES NO 16220-1 Line 2/0-8 Cu, Load (4) 4-12 Cu, 1-Pole 200A Class J, T, CC or G 200 YES NO* YES NO 16220-1 Line 2/0-8 Cu, Load (4) 4-14 Cu, 1-Pole 175A Class J, T, CC or G 100 YES NO* YES NO 16220-2 Line 2/0-8 Cu, Load (4) 4-12 Cu, 2-Pole 200A Class J, T, CC or G 200 YES NO YES NO 16220-2 Line 2/0-8 Cu, Load (4) 4-14 Cu, 2-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16220-3 Line 2/0-8 Cu, Load (4) 4-12 Cu, 3-Pole 200A Class J, T, CC or G 200 YES NO YES NO 16220-3 Line 2/0-8 Cu, Load (4) 4-14 Cu, 3-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16280-1 Line 2/0-8 Cu, Load 1/4-20 X 3/4 STUD, 1-Pole 200A Class J, T, CC or G 200 YES NO* YES NO 16280-2 Line 2/0-8 Cu, Load 1/4-20 X 3/4 STUD, 2-Pole 200A Class J, T, CC or G 200 YES NO YES NO 16280-3 Line 2/0-8 Cu, Load 1/4-20 X 3/4 STUD, 3-Pole 200A Class J, T, CC or G 200 YES NO YES NO 16321-1 Line 2/0-8 Cu, Load (6) 4-12 Cu, 1-Pole 400A Class J, T, CC or G 200 YES YES YES NO 16321-1 Line 2/0-8 Cu, Load (6) 4-14 Cu, 1-Pole 175A Class J, T, CC or G 100 YES YES YES NO 16321-2 Line 2/0-8 Cu, Load (6) 4-12 Cu, 2-Pole 400A Class J, T, CC or G 200 YES YES YES NO 16321-2 Line 2/0-8 Cu, Load (6) 4-14 Cu, 2-Pole 175A Class J, T, CC or G 100 YES YES YES NO 16321-3 Line 2/0-8 Cu, Load (6) 4-12 Cu, 3-Pole 400A Class J, T, CC or G 200 YES YES YES NO 16321-3 Line 2/0-8 Cu, Load (6) 4-14 Cu, 3-Pole 175A Class J, T, CC or G 100 YES YES YES NO 16323-1 Line 350-4 Cu, Load (6) 4-8 Cu, 1-Pole 400A Class J, T, CC or G 200 YES NO* YES NO 16323-1 Line 350-4 Cu, Load (6) 4-12 Cu, 1-Pole 175A Class J, T, CC or G 100 YES NO* YES NO 16323-2 Line 350-4 Cu, Load (6) 4-8 Cu, 2-Pole 400A Class J, T, CC or G 200 YES NO YES NO 16323-2 Line 350-4 Cu, Load (6) 4-12 Cu, 2-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16323-3 Line 350-4 Cu, Load (6) 4-8 Cu, 3-Pole 400A Class J, T, CC or G 200 YES NO YES NO 16323-3 Line 350-4 Cu, Load (6) 4-12 Cu, 3-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16370-1 Line 350-4 Cu, Load (12) 4-8 Cu, 1-Pole 400A Class J, T, CC or G 200 YES NO* YES NO 16370-1 Line 350-4 Cu, Load (12) 4-14 Cu, 1-Pole 175A Class J, T, CC or G 100 YES NO* YES NO 16370-2 Line 350-4 Cu, Load (12) 4-8 Cu, 2-Pole 400A Class J, T, CC or G 200 YES NO YES NO 16370-2 Line 350-4 Cu, Load (12) 4-14 Cu, 2-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16370-3 Line 350-4 Cu, Load (12) 4-8 Cu, 3-Pole 400A Class J, T, CC or G 200 YES NO YES NO 16370-3 Line 350-4 Cu, Load (12) 4-14 Cu, 3-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16371-1 Line 350-4 Cu, Load (6) 2-6 and (3) 1/10-6 Cu, 1-Pole 400A Class J, T, CC or G 200 YES NO* YES NO 16371-1 Line 350-4 Cu, Load (9) 2-12 Cu, 1-Pole 175A Class J, T, CC or G 100 YES NO* YES NO 16371-2 Line 350-4 Cu, Load (6) 2-6 and (3) 1/10-6 Cu, 2-Pole 400A Class J, T, CC or G 200 YES NO YES NO 16371-2 Line 350-4 Cu, Load (9) 2-12 Cu, 2-Pole 175A Class J, T, CC or G 100 YES NO YES NO 16371-3 Line 350-4 Cu, Load (6) 2-6 and (3) 1/10-6 Cu, 3-Pole 400A Class J, T, CC or G 200 YES NO YES NO 16371-3 Line 350-4 Cu, Load (9) 2-12 Cu, 3-Pole 175A Class J, T, CC or G 100 YES NO YES NO *May be possible to use if spaced as required per UL 508A Standard UL Recognized to Use Group C 5

UL 1059 Recognized Power Terminal Block Application Chart @ 600V Cooper UL 508A UL 508A Bussmann Branch Feeder UL NEC Part Number Description Max OCPD SCCR (ka) Circuit Circuit 1995 376.56(B) 14002-2 Line 2-14 Cu, Load 2-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 14002-3 Line 2-14 Cu, Load 2-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 14002-4 Line 2-14 Cu, Load 2-8 AI, 4-Pole Size per NEC 10 YES NO YES NO 16021-2 Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 16021-3 Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16021-4 Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 4-Pole Size per NEC 10 YES NO YES NO 16023-2 Line 350-6 Cu/AI, Load (6) 4-14 Cu or (6) 4-12 AI, 2-Pole Size per NEC 10 YES NO YES NO 16023-3 Line 350-6 Cu/AI, Load (6) 4-14 Cu or (6) 4-12 AI, 3-Pole Size per NEC 10 YES NO YES NO 16023-4 Line 350-6 Cu/AI, Load (6) 4-14 Cu or (6) 4-12 AI, 4-Pole Size per NEC 10 YES NO YES NO 16204-1** Line 2/0-8 Cu/AI, Load 2/0-8 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16204-2** Line 2/0-8 Cu/AI, Load 2/0-8 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16204-3** Line 2/0-8 Cu/AI, Load 2/0-8 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO 16220-1** Line 2/0-14 Cu or 2/0-8 AI, Load (4) 14-4 Cu or (4) 4-8 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16220-2** Line 2/0-14 Cu or 2/0-8 AI, Load (4) 14-4 Cu or (4) 4-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 16220-3** Line 2/0-14 Cu or 2/0-8 AI, Load (4) 14-4 Cu or (4) 4-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16280-1** Line 2/0-14 Cu/AI, Load 1/4-20 X 3/4 STUD, 1-Pole Size per NEC 10 YES NO* YES NO 16280-2** Line 2/0-14 Cu/AI, Load 1/4-20 X 3/4 STUD, 2-Pole Size per NEC 10 YES NO YES NO 16280-3** Line 2/0-14 Cu/AI, Load 1/4-20 X 3/4 STUD, 3-Pole Size per NEC 10 YES NO YES NO 16301-1 Line 250-6 Cu, Load 250-6 Cu, 1-Pole Size per NEC 10 YES NO* YES NO 16301-2 Line 250-6 Cu, Load 250-6 Cu, 2-Pole Size per NEC 10 YES NO YES NO 16301-3 Line 250-6 Cu, Load 250-6 Cu, 3-Pole Size per NEC 10 YES NO YES NO 16303-1 Line 350-6 Cu/AI, Load 350-6 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16303-2 Line 350-6 Cu/AI, Load 350-6 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16303-3 Line 350-6 Cu/AI, Load 350-6 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO 16306-1 Line 500-6 Cu/AI, Load 500-6 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16306-2 Line 500-6 Cu/AI, Load 500-6 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16306-3 Line 500-6 Cu/AI, Load 500-6 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO 16321-1** Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 1-Pole Size per NEC 10 YES YES YES NO 16321-2** Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 2-Pole Size per NEC 10 YES YES YES NO 16321-3** Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 3-Pole Size per NEC 10 YES YES YES NO 16323-1** Line 350-6 Cu/AI, Load (6) 4-14 Cu or (6) 4-12 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16323-2** Line 350-6 Cu/AI, Load (6) 4-14 Cu or (6) 4-12 AI, 2-Pole Size per NEC 10 YES NO YES NO 16323-3** Line 350-6 Cu/AI, Load (6) 4-14 Cu or (6) 4-12 AI, 3-Pole Size per NEC 10 YES NO YES NO 16325-1 Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16325-2 Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 16325-3 Line 2/0-14 Cu or 2/0-8 AI, Load (6) 4-14 Cu or (6) 4-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16330-1 Line 500-6 Cu/AI, Load (6) 2-14 Cu or 2-12 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16330-2 Line 500-6 Cu/AI, Load (6) 2-14 Cu or 2-12 AI, 2-Pole Size per NEC 10 YES NO YES NO 16332-3 Line 350-6 Cu/AI, Load (3) 2-14 Cu or 2-8 AI and (2) 1/0-14 Cu or 1/10-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16335-1 Line 500-6 Cu/AI, Load (3) 2-14 Cu or 2-8 AI and (2) 1/0-14 Cu or 1/10-8 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16335-2 Line 500-6 Cu/AI, Load (3) 2-14 Cu or 2-8 AI and (2) 1/0-14 Cu or 1/10-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 16335-3 Line 500-6 Cu/AI, Load (3) 2-14 Cu or 2-8 AI and (2) 1/0-14 Cu or 1/10-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16370-1** Line 350-6 Cu/AI, Load (12) 4-14 Cu or (12) 4-12 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16370-2** Line 350-6 Cu/AI, Load (12) 4-14 Cu or (12) 4-12 AI, 2-Pole Size per NEC 10 YES NO YES NO 16370-3** Line 350-6 Cu/AI, Load (12) 4-14 Cu or (12) 4-12 AI, 3-Pole Size per NEC 10 YES NO YES NO 16371-1** Line 350-6 Cu/AI, Load (6) 2-14 Cu or (6) 2-14 Cu or (6) 2-8 AI and (3) 1/0-14 Cu or (3) 1/0-8 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16371-2** Line 350-6 Cu/AI, Load (6) 2-14 Cu or (6) 2-14 Cu or (6) 2-8 AI and (3) 1/0-14 Cu or (3) 1/0-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 16371-3** Line 350-6 Cu/AI, Load (6) 2-14 Cu or (6) 2-14 Cu or (6) 2-8 AI and (3) 1/0-14 Cu or (3) 1/0-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16372-1 Line 350-6 Cu/AI, Load (21) 10-14 Cu or 10 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16372-2 Line 350-6 Cu/AI, Load (21) 10-14 Cu or 10 AI, 2-Pole Size per NEC 10 YES NO YES NO 16372-3 Line 350-6 Cu/AI, Load (21) 10-14 Cu or 10 AI, 3-Pole Size per NEC 10 YES NO YES NO 16373-1 Line 350-6 Cu/AI, Load (14) 10-14 Cu or 10 AI and (3) 1/0-14 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16373-2 Line 350-6 Cu/AI, Load (14) 10-14 Cu or 10 AI and (3) 1/0-14 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16373-3 Line 350-6 Cu/AI, Load (14) 10-14 Cu or 10 AI and (3) 1/0-14 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO 16375-1 Line 600-2 Cu/AI, Load (12) 4-14 Cu or 4-12 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16375-2 Line 600-2 Cu/AI, Load (12) 4-14 Cu or 4-12 AI, 2-Pole Size per NEC 10 YES NO YES NO 16375-3 Line 600-2 Cu/AI, Load (12) 4-14 Cu or 4-12 AI, 3-Pole Size per NEC 10 YES NO YES NO 16376-1 Line 600-2 Cu/AI, Load (6) 2-14 Cu or 2-8 AI and (3) 1/0-14 Cu or 1/10-8 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16376-2 Line 600-2 Cu/AI, Load (6) 2-14 Cu or 2-8 AI and (3) 1/0-14 Cu or 1/10-8 AI, 2-Pole Size per NEC 10 YES NO YES NO 16376-3 Line 600-2 Cu/AI, Load (6) 2-14 Cu or 2-8 AI and (3) 1/0-14 Cu or 1/10-8 AI, 3-Pole Size per NEC 10 YES NO YES NO 16377-1 Line (2) 300-4 Cu/AI, Load (12) 4-14 Cu or 4-12 AI, 1-Pole Size per NEC 10 YES NO* YES NO 16377-2 Line (2) 300-4 Cu/AI, Load (12) 4-14 Cu or 4-12 AI, 2-Pole Size per NEC 10 YES NO YES NO 16377-3 Line (2) 300-4 Cu/AI, Load (12) 4-14 Cu or 4-12 AI, 3-Pole Size per NEC 10 YES NO YES NO 16528-1 Line (2) 600-2 Cu/AI, Load (4) 3/0-6 Cu/AI and (4) 4-14 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16528-2 Line (2) 600-2 Cu/AI, Load (4) 3/0-6 Cu/AI and (4) 4-14 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16528-3 Line (2) 600-2 Cu/AI, Load (4) 3/0-6 Cu/AI and (4) 4-14 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO 16530-1 Line (2) 500-6 Cu/AI, Load (12) 4-14 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16530-2 Line (2) 500-6 Cu/AI, Load (12) 4-14 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16530-3 Line (2) 500-6 Cu/AI, Load (12) 4-14 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO 16541-1 Line 500-6 Cu/AI, Load (21) 6-14 Cu/AI, 1-Pole Size per NEC 10 YES NO* YES NO 16541-2 Line 500-6 Cu/AI, Load (21) 6-14 Cu/AI, 2-Pole Size per NEC 10 YES NO YES NO 16541-3 Line 500-6 Cu/AI, Load (21) 6-14 Cu/AI, 3-Pole Size per NEC 10 YES NO YES NO *May be possible to use if spaced as required per UL 508A Standard ** SCCR with up to 200kA UL Recognized to Use Group C The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 6