IC Scanner ICS 105. User manual. Copyright November 2013 LANGER EMV-Technik GmbH IC Scanner ICS 105/1216

Similar documents
Operation manual. IC-Scanner FLS 102. Copyright April 2008 LANGER EMV-Technik GmbH IC-Scanner FLS 102/0214

B63/ NS MS. EtherNet/IP LINK

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

F1000 User's Manual. (Version: V1.01)

Operating Instructions

38 MHz Passive Voltage Probe R&S RT-ZP1X

Model 2657A-LIM-3 LO Interconnect Module

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

Agilent 70612B K18 Switch Matrix

1. Safety Precautions (Read these precautions before use.)

EQUIPMENT OPERATION MANUAL

Video Microscope Table MEA-VMT Manual

Operation Manual. Equipment. Operation Manual. Loctite RB30 Robot Camera. Part Number:

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

* * Agilent Power Distribution Unit (PDU) Installation Guide

PTZ Control VMC Joystick

HD40H(X) Performance Series Camera. User Guide

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

RobotEye RELW60. High Speed Long Wave Infra-Red Thermal Imaging System User Manual

User Manual. Printer P-52RUE

icore Kiosk system Installation Guide

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

1. Safety Precautions (Read these precautions before use.)

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

Installation Instructions

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

EC Series. Safety Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Camera A14 and A34 Dome Camera

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

2260B-RMK-Series Rack Mount Kit

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

TVAC25100 TVAC25110 User manual

Agilent OBSAI Protocol Tester

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Camera. Network Bullet Camera. Quick Operation Guide

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

3700 SERIES USER MANUAL

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Startup Software Quick Start Guide

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Dino-Lite Handheld Digital Microscope AM413T. User s Manual

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MT8050iE series. Installation Instruction (1) (2)

General Operating, Maintenance and Installation Manual

SIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Flow Sensor SONOFLOW CO.55

EQUIPMENT OPERATION MANUAL

User s Manual Power Supply IM E. 5th Edition

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

MDM 011-Z1 Regen Resistor

TURBO HD TVI Bullet & Turret Camera

2 1.1 Safety using methods Definition of warning symbols Standard accessories Installation...

RТTH DUAL ROOM SWITCH

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Blue Weapon Laser. User manual UK. Version 1.0

User Guide True RMS Multimeter Extech EX205T

Network Camera. Quick Guide DC-B1203X. Powered by

Techno SERVO GCODE INTERFACE

Control unit IndraDrive Commissioning Linear axis LDx with IndraDrive control unit

SATA II HDD Canister KISS DA 435 Quick Reference Guide

DS-1H05 Ethernet-over-Coax Extender. User Manual

SolConeX extra-low voltage flange socket

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Spectrum Laser. User manual UK. Version 1.0

Advidia A-15 & A-35 Installation Manual

Start Here. All-in-One Printer. Print Copy Scan

PHOS 20/40 downlight OWNER'S MANUAL

RXTP ROOM TEMPERATURE

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Channel Switch CS. General Operating, Maintenance and Installation Manual

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Assembly and Operating Instructions Door Control

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

HV-CS kv Edge Mount Triaxial Jack

Operating instructions. Speed monitor D / / 2014

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

OX 5022-CK OX 5042-CK

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Transcription:

IC Scanner ICS 105 User manual Copyright November 2013 LANGER GmbH /1216

2 Table of contents 1. Measurement Setup... 3 1.1 Safety Instructions... 3 1.1.1 Safety Precautions...3 1.1.2 Warranty...3 1.1.3 Safety Instruction...4 1.2 Setup Parts... 5 1.3 Mounting of the ICR Near-Field Microprobe... 6 2. Software Installation... 7 2.1 General Installation Requirements and ChipScan Scanner Installation... 7 2.2 Installation of TMCM-6110 Driver... 7 3. Setting up and Commissioning... 10 4. Operational Notes...11 4.1 Connecting the IC Scanner to your PC...11 4.2 Placing a Probe at a Specific Distance above a DUT...11 4.3 Determine the Duration of a Measurement with the IC Scanner...11 4.3.1 Moving Distance... 11 4.3.2 Sweep Time...12 4.3.3 Transfer Time...12 4.5 Relation between Span, Resolution Bandwidth and Points per Trace... 12 5. Technical Characteristics... 13 No part of this manual may be copied, duplicated or processed using electronic systems without the written consent of Langer EMV Technik GmbH. The management of Langer EMV Technik GmbH assumes no liability for damages which may result from the use of this printed information.

1. Measurement Setup 3 1. Measurement Setup 1.1 Safety Instructions This product complies with the requirements of the following European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) 1.1.1 Safety Precautions The IC Scanner has been designed for IC measurements with near-field microprobes. Any other use is not permitted. When using the IC Scanner please observe the following basic safety instructions to protect yourself against electric shock and the risk of injury: read and comply with the operating manual keep the operating manual in a safe place for subsequent use follow the safety instructions and warnings on the unit always perform a visual check of the IC Scanner before use keep hands away from moving and rotating parts do not leave the IC Scanner unsupervised read the explanation of the symbols on the unit in the operating manual do not switch the IC Scanner unit on until it has been completely assembled damaged connection cables are extremely dangerous! 1.1.2 Warranty We will remedy any faults due to faulty materials or manufacturing during the statutory warranty period at our discretion, either by a repair or the supply of spare parts. The warranty period is subject to the applicable law of the country in which the IC Scanner was purchased. The warranty is only valid under the following conditions: the IC Scanner and the micro probes have been treated properly the operating instructions have been followed only genuine spare parts have been used where necessary external components (spectrum analyzer, etc.) seperate warranty terms of the relevant manufacturer apply The warranty is forfeited if: attempts have been made to repair the IC Scanner the IC Scanner has been altered the IC Scanner has been used incorrectly

1. Measurement Setup 4 1.1.3 Safety Instruction 1. In order to meet the requirements of the European Community (CE) safety directives, the IC Scanner must be placed in an enclosure. The enclosure will prevent the operator from entering the IC Scanners work area and will generate an emergency stop signal if the enclosures door switch is opened while the robot is running. 2. Make sure the robot and accessories are connected to a properly grounded power source. 3. Do not connect or disconnect any cable while the IC Scanner is powered on. 4. Do not drop or spill foreign objects or material such as screws or liquids into the IC Scanner. 5. Do not touch any moving parts while the IC Scanner is running. 6. Loading and unloading of parts and material must be done when the IC Scanner is not running. 7. Changing of fixtures or tooling must be done with the power source disconnected. 8. The IC Scanner should only be operated in an environment of 0 to 40 degrees centigrade and humidity of 20 to 95 percent with no condensation. 9. Do not store or install the IC Scanner in an area where it is exposed to direct sunlight. 10. Do not operate the IC Scanner where electrical noise is present. 11. Only use a neutral detergent for cleaning.

1. Measurement Setup 5 1.2 Setup Parts Mover system for 4 axes (1) + Cable for power supply (2) + USB cable with Hi-Speed USB (USB 2.0) certification (3) Optical control unit + Video Microscope (4) + Prism (5) + Camera holder mounted on the Mover (6) Probes + ICR near-field microprobe (7) + Bias tee (8) with power supply unit (9) + Documentation + Measuring cable (10) Ground Plane (11) ChipScan Scanner software (12) PC (13) Spectrum analyzer (14) DUT (Device Under Test) (15)

1. Measurement Setup 6 1.3 Mounting of the ICR Near-Field Microprobe 1. Attach the depth test cable (1) to the ICR near-field microprobe (2). 2. Attach the measurment cable (3) to the probe. 3. Screw the probe with its protective cap still present to the ring of the rotation axis (4) with the two black finger screws (5). 4. Remove the protective cap of the ICR probe right before you want to start a measurement and re-attach it again once you are done measuring to protect the tip of the probe.

2. Software Installation 7 2. Software Installation The setup of the entire system hardware needs to be completed first in accordance to chapter 1. To start the installation process please insert the delivered installation CD into your CD drive. 2.1 General Installation Requirements and ChipScan Scanner Installation Please open the folder Documentation on the installation CD and see the ChipScan Scanner manual chipscan.pdf chapter 1 for details. 2.2 Installation of TMCM-6110 Driver As Windows cannot install the driver for the TMCM-6110 built into the IC Scanner this driver installation needs to be done as follows: 1) Power-on the IC Scanner so Windows can install all the IC Scanner device drivers except the driver for the TMCM-6110. 2) Open the Windows Device Manager from the Windows System control. 3) Within the Windows Device Manager double click on the TMCM-6110 (virtual COM) entry.

2. Software Installation 8 4) In the appearing properties dialog select the Driver tab and click on Driver update. 5) In the following dialog choose the entry to look on the computer for the driver software (so do not choose the automatic driver detection option). 6) Use the browse button, select the CD drive where you inserted the delivered ChipScan Scanner installation CD, select the Driver subdirectory from the CD and press the Continue button.

2. Software Installation 9 7) In the following warning from Windows choose to install the driver software nevertheless. 8) The driver is installed and finally it should appear in the Windows Device Manager as follows.

3. Setting up and Commissioning 10 3. Setting up and Commissioning Please be sure to have completed chaper 1 and 2 from this manual. To confirm the proper operation of the IC Scanner please follow the following steps. Details on specific steps can be found in the ChipScan Scanner manual which you can open from within ChipScan Scanner by clicking on the menu Help entry Manual... 1. Switch on - the IC Scanner - your PC 2. Start ChipScan Scanner 3. Connect ChipScan Scanner to the IC Scanner - within ChipScan Scanner click on the menu Devices entry Show Device Manager - within the Device Manager dialog: - to speed up the detection of the IC Scanner you may do the following in the section Scanner: - select the COM port the IC Scanner is connected to in the RS232 choice box - select the Langer ICS105 in the choice box to speed up its detection - press the Detect Devices button - the device detection takes a little while and afterwards you should find the following in the section Identified devices used for measurement: - in the Video Device choice box Video Device 1 - in the Scanner choice box Langer ICS105 You may find further details in the ChipScan Scanner manual chapter 4. 4. Open the Video View If you want to be using the Video Microscope click on the menu Devices entry Show Video View. 5. Start using the IC Scanner via the XMLRPC interface You may find further details in the ChipScan Scanner manual chapter 5. Also you may have a look at the XMLRPC client demo XMLRPC example client.py written in the Python programming language in the Documentation\XMLRPC Python example client directory on the delivered ChipScan Scanner installation CD.

4. Operational Notes 11 4. Operational Notes 4.1 Connecting the IC Scanner to your PC When connecting the IC Scanner to your PC make sure to use a USB cable which has a Hi-Speed USB certification (USB 2.0) and has a maximum length of 2 meters. 4.2 Placing a Probe at a Specific Distance above a DUT Attention: The following instructions may cause damage to your probe, your DUT or both. Before starting espacially make sure to power off your DUT to avoid any short circuit. Also keep in mind the tip of your probe is very fragile. Make sure your DUT surface is evenly and positioned leveled to the surface of the scanner to avoid the probe scratching along the DUTs surface during movements. In any circumstances please proceed with caution. In many cases it is required to place a probe at a specific distance above your DUT. To accomplish this task complete the steps of the following procedure. 1. Power off your DUT. 2. Move the probe over the point of interest while keeping a safe distance to the DUT. 3. Put a prism right next to the point of interest. 4. Use the prism s sloped surface as a mirror to identify the space between the probes tip and DUT s surface with the Video Microscope. 5. Move down your probe using an appropriate vertical distance. 6. If the vertical distance is not appropriate anymore decrease it, e.g. divide it by ten. 7. Repeat steps 5. and 6. under permanent examination of the probe tip with the Video Microscope until the probe almost touches the DUT s surface. 8. Reduce the vertical moving distance to the minimum of 20 µm. 9. Try to move down your probe, while checking the distance between probe and DUT using the prism and Video Microscope. 10. If the probe is finally touching the surface of your DUT move the probe up for a specific distance. 4.3 Determine the Duration of a Measurement with the IC Scanner The duration of a measurement with the IC Scanner will increase linearly with the number of measurement points. In addition the duration mainly depends on the following three properties: The time for the movement between two adjacent measurement points. The time for a full sweep of the spectrum analyzer. The time to transfer a trace from the spectrum analyzer to your computer. 4.3.1 Moving Distance The smaller the distance between two adjacent measurement points, the less time is required for the movement.

4. Operational Notes 12 4.3.2 Sweep Time The higher the sweep time, the more time is required for measurement. Keep in mind the sweep time itself may take up a multiple of the time required to move the probe and to transfer the trace. Especially if a wide span and a small resolution bandwidth is used the sweep time may take several seconds. Also if you use Average the sweep time is multiplied by the set Average Count. 4.3.3 Transfer Time The time to transfer a trace from the spectrum analyzer to your computer mainly depends on the type of transfer interface being used. When using GPIB and VXI the time needed to transfer a trace with 1000 points will be in the range of milliseconds. In contrast if you use the RS232 interface with a low baudrate the transfer time may be in the range of seconds. 4.5 Relation between Span, Resolution Bandwidth and Points per Trace The amount of points per trace set in the spectrum analyzer limits the frequency resolution. In fact the span is divided by the number of points per trace. At these frequency points the spectrum analyzer will measure a signal using the currently set resolution bandwidth. For example a signal measured with a very wide span and a small resolution bandwidth might have good signal to noise ratio but will miss several frequency components if the number of points per trace is low. For further information have a look at your spectrum analyzer manual.

5. Technical Characteristics 13 5. Technical Characteristics Application: Surface scans over ICs in accordance with IEC61967-3 Volume scans over ICs PIN scans System component parts: 4-axis positioning system Video microscope Ground plane (type GND 25) ChipScan Scanner control and measurement software optional: Near-field microprobes for E- and H-fields (type ICR) Properties: The IC Scanner can be adapted with different ICR probes to measure E- and H-near fields. The probes can be moved above the chip surface in all three axes and around the z-axis. The scanner allows the user to check the position of the probe tip visually through a video microscope. The scanner is controlled via PC with the ChipScan Scanner software. Axes x y z α-rotation Max. measuring range 50 mm 50 mm 50 mm +/- 180 Accuracy 10 µm 10 µm 10 µm 1 Repeatability +/- 1 µm +/- 1 µm +/- 1 µm +/- 1 Speed 2 mm/s 2 mm/s 2 mm/s 45 /s Control USB Supply voltage 110 / 230 V Dimensions / total weight (350 x 400 x 420) mm / 23 kg Software: Optional accessories: Scope of delivery: ChipScan Scanner zero position, manual or script-based probe movement reading the data from a spectrum analyser visualisation of the measuring results in 2D or 3D output as csv and image files UH-DUT universal holder for mounting the electronics ICR near-field microprobes for E and H fields ICS 105 IC Scanner Video microscope with holder GND 25 ground plane ChipScan Scanner software Flight case