Online data sheet MEAC
A B C D E F H I J K L M N O P Q R S T Ordering information Type MEAC Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Our regional sales organization will help you to select the optimum device configuration. Other models and accessories www.sick.com/meac Product description The MEAC offers continuous acquisition, evaluation, storage and visualization, as well as transfer of emission data for modern emission data management. Up to 16 data acquisition units, each equipped with a scalable ring buffer, can be connected to the central Emission-PC. It is also possible to integrate process control systems. MEAC is TÜV approved and certified. The MEAC2012 version is designed to meet German legislative requirements, while the MEAC2000 EU complies with European directives and regulations. At a glance Evaluations according to 1, 2, 13, 17, 27, 30, 31 BImSchV and TA Luft Analog and digital data collection saved at 5 s/1 min intervals with auto-backup Distributed visualization, operation in the network and automatic e-mail alarms Flexible data presentation also in process images Analog and digital data to the customer system at 5 s/1 min intervals Recording of QAL3 cycles Your benefits Time savings through simulation mode for installation and functions checks Savings on service costs through flexible parameterizing interface for users, e.g for device calibration High availability through automatic synchronization service for data and parameters Parallel calculation of greenhouse gas emissions in the same system Fewer limit violations due to special CO evaluation User can draft own reports in MS Excel format, to which data are then added automatically Customer network can be used to connect to process control systems, no need for new cabling Continued use of existing data and parameters from earlier MEAC versions 2 ANALYZER SOLUTIONS SICK Online data sheet 2016-11-30 09:46:27 Subject to change without notice
Fields of application Acquisition of measured and operating data for continuous emission monitoring Data preparation in compliance with legislation Free customized and legislative reporting Data transmission rate to authority Detailed technical data MEAC2012 system Conformities EN 14181 TA-Luft (Prevention of Air Pollution) 1. BImSchV 2. BImSchV 13. BImSchV 17. BImSchV 30. BImSchV 31. BImSchV BEP 2010 Status identifier and classing 2012 Calculation interval Integration time Value type Software modules Menu languages 5 s 1 min, 3 min, 10 min, 30 min, 60 min, 120 min, 240 min, 480 min 5s value Average value Trend for average value Moving average value Daily average value Trend for daily average value Moving daily average value Monthly average value Annual average value Daily total emissions Monthly total emissions Annual total emissions Evaluation software version 3.00 (parameterization required) Remote access for remote PC (option) Network access for central PC (option; using a modem connection a data transfer software for Emission-PC is required) Remote service (option) Process display (option) Manual input (option) MEx automatic report export to MS Excel or XML (option; Excel template and configuration required) MEx configurator (option) QAL3 driver (option; SICK QAL3 Master required) Synchronization service (option) E-mail alerts (option) German MEAC2000 EU system Conformities EN 14181 2001/80/EC 2000/76/EC Calculation interval Integration time Value type 1 min 3 min, 10 min, 20 min, 30 min, 60 min, 120 min, 240 min, 480 min 1-min value Average value Trend for average value Daily average value Trend for daily average value 2016-11-30 09:46:27 Online data sheet Subject to change without notice ANALYZER SOLUTIONS SICK 3
A B C D E F H I J K L M N O P Q R S T Software modules Menu languages MEAC GHG system Conformities Calculation interval Integration time Value type Software modules Menu languages Emission-PC Monthly average value Annual average value Daily total emissions Monthly total emissions Annual total emissions Evaluation software version 1.28 EU (parameterization required) Remote access for remote PC (option) Network access for central PC (option; using a modem connection a data transfer software for Emission-PC is required) Remote service (option) Process display (option) Manual input (option) MEx automatic report export to MS Excel or XML (option; Excel template and configuration required) MEx configurator (option) QAL3 driver (option; SICK QAL3 Master required) Synchronization service (option) E-mail alerts (option) German, English, French, Italian, Croatian, Lithuanian, Macedonian, Dutch, Portugese, Russian, serbian, Slovak, Slovenian, Spanish, Hungarian 2003/87/EC MVO (DEHSt) 5 s 60 min 5s value Hourly average value Substitute hourly average value Daily average value Annual average value Hourly payload Daily total emissions Annual total emissions Acquisition software version 3.00 (parameterization required) Modbus-Master Database output Database MySQL GHG reporting Remote service (option) German, English Ambient temperature +5 C... +30 C Electrical safety Enclosure rating IP 20 Interfaces and bus protocols Operation Power supply Options Ethernet CE Modbus TCP Ethernet OPC DA 2.0 RS-485 RS-485 RS-232 Voltage Modbus RTU PROFIBUS DP Modbus RTU Via software MEAC 230 V AC System requirement for a PC provides by the customer: 4 ANALYZER SOLUTIONS SICK Online data sheet 2016-11-30 09:46:27 Subject to change without notice
Operating system: Windows XP Professional SP3, Windows 7 Ultimate 32/64bit SP1 Processor: 2,5 GHz Memory: 2 GB RAM Harddisk: 2 x 300 GB Power supply: 500 W Free slots: 3 x PCI for radio clock, modem and watchdog DAE data acquisition unit Ambient temperature 5 C... +50 C Electrical safety CE Enclosure rating IP 54 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces and bus protocols Operation Dimensions (W x H x D) Weight Power supply FM field module RS-232 Voltage 8 outputs: 0... 25 ma Max. 32 outputs, not potential-free 16 inputs: -5... 30 ma, 100 Ω Max. 80 inputs, potential-free up to ±10 V 12 change-over contacts: 48 V AC, 500 ma Max. 96 outputs 32 inputs: 24 V Max. 256 inputs, potential-free Proprietary interface Via Emission-PC and software MEAC See dimensional drawings 12 kg 115 V AC / 230 V AC Ambient temperature 10 C... +50 C Electrical safety CE Enclosure rating IP 20 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces and bus protocols Operation Dimensions (W x H x D) Power supply RS-485 2 outputs: 0... 20 ma Max. 16 outputs, not potential-free 2 inputs: 0... 20 ma Max. 16 outputs, single-ended, not potential-free 4 outputs: 24 V, 500 ma Max. 24 outputs 4 inputs: 24 V Max. 32 inputs Modbus RTU Via Emission-PC and software MEAC See dimensional drawings 2016-11-30 09:46:27 Online data sheet Subject to change without notice ANALYZER SOLUTIONS SICK 5
A B C D E F MEAC Voltage 24 V DC Dimensional drawings (Dimensions in mm (inch)) DAE data acquisition unit 483 (19.02) Power Function TX RX H I J K L M N O P Q R S T FM field module 51 (2.01) 65 (2.56) 100 (3.94) 135 (5.31) 6 ANALYZER SOLUTIONS SICK Online data sheet 2016-11-30 09:46:27 Subject to change without notice
Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations www.sick.com SICK AG Waldkirch Germany www.sick.com