DMA 4200 M. Density Meter for the Petroleum Industry. ::: Unique Density & Concentration Meters

Similar documents
Portable Density and Concentration Meter DMA 35

L-Dens 4X7 Series. Process Density Sensors. ::: Process instrumentation at its best

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

DMA 35. Portable Density/Specific Gravity/Concentration Meter. ::: Unique Density & Concentration Meters

Portable Density/Specific Gravity/Concentration Meter

The DDM 2909 Automatic Density Meter

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

The DDM 2911 PLUS Automatic Density Meter

The DDM 2911 PLUS Automatic Density Meter

The DDM 2911 Automatic Density Meter

The DDM 2911 Automatic Density Meter

The DDM 2911 Automatic Density Meter

DMA 35N. Portable Density, Specific Gravity & Concentration Meter. ::: Unique Density & Concentration Meters

Laboratory Density and Concentration Meters. DMA Generation M DSA 5000 M

Density and Concentration Meters Generation M

MCP 300/500 Polarimeter

The Autopol VI Automatic Polarimeter

Isotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific

The DDM Series of Automatic Density Meters

Mya 4 Reaction Station

Density and Concentration Meters Generation M

AR200. Refractometer User s Guide. Page 1

Titration Automation. Fully Automate your Titration Processes for Maximum Efficiency and Security. Titration Automation

FOSTEN AUTOMATION SÉRIE F500-A

The DDM Series of Automatic Density Meters

Dry Bath Incubator. MK-10/MK-20 Dry Bath Incubator. Features: Specification: Block for MK-10 / MK-20

Mitos P-Pump. product datasheet

DVM HPHT ULTRA HIGH ACCURACY SIMULTANEOUS DENSITY AND VISCOSITY MEASUREMENT

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements Communic

METER REGISTER & DATA CONTROLLER

novo AlphaTack Plus accurate tack measurements made simple

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

AR2008 Digital Abbe Refractometer

The Perfect Fit for Over 40 Years

UNDERWATER ACOUSTIC MODEMS PRODUCT INFORMATION GUIDE

New. Products. piezo switches piezo keypads piezo keyboards piezo technology IP68/ip69k/atex Fax:

ProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

FoamDDI. Foam Digital Detection Imaging

Firefighting Monitors

0.1 Slow Monitoring and Recording System

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Product Catalog. EasySampler EasySampler Unattended, Representative Sampling

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Talboys Standard Analog Dry Block Heaters

914L. Capacitive Level Transmitter. Features. 1 Datasheet 914L Capacitive level transmitter for liquids.

Digital pressure gauges

Digital Hydrometer SBS-2500 INSTRUCTION MANUAL. Storage Battery Systems LLC Instruction Manual for SBS-2500 Digital Hydrometer Rev.

SPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry

The of Automatic For High Accuracy Applications The DDM Series of Automatic Density Meters

Remote Asset- Integrity Monitoring

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

FOSTEN AUTOMATION SÉRIE F500-SRT

Your Global Automation Partner. The Full Range for Automation

The A320i ink jet printer Breaking the service routine

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

Level sensor for monitoring the level of liquid media

intelligent MULTI SAFETY LINK imsl SIL 2 - IEC / IEC INTEGRATED BERTHING MOORING TOWING SOLUTIONS

Level Measurement. Tank Level Instruments TLI

40 years ago we invented the touchscreen. Today we're reinventing how people interact with their world.

Penetration - Bitumen Method - PNR 12 (automatic)

Research Grade Meters

Level gauges for your purposes

Electrodes ph EC DO /14 dge 2 P/L e

UndErwatEr acoustic modems. product information GUidE

Penetration: Penetrometer PNR 12 (Bitumen)

Smart Conductivity. Reliable and Accurate Conductivity/Resistivity Measurement. THORNTON Leading Pure Water Analytics

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad

Contact Angle Instruments For the measurement of surface properties

Moisture Analyzers EM 120-HR

832 Series: Sulfur/Carbon Analysis by Combustion

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

914S. Capacitive Sanitary Pressure Transmitter. Features. 1 Datasheet 914S Capacitive Sanitary Pressure Transmitter

CoriolisMaster Accurate flow measurement of liquids and gases

Sonicator -Standard Operating Procedure [Updated September 10, 2014] Location of Machine: Composites Lab - Nanoparticle Containment Room, RFM 1218

Resistive Touch Screens

Level measurement. Applications. Special features. Description

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

Revolutionary. Heart Valve Durability Tester. VDT-3600i. Medical Device Testing & Equipment Simulation Platforms Silicone Vessels

NANOMETRIC LAB PRINTER. Plug & Play Solution for ultra-precise printing of conductive lines in nano-scale

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

770MAX Conductivity/Resistivity Sensors THORNTON. Leading Pure Water Analytics

NF770 Temperature Compensation Liquid Flow Computer

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Resolution selectable from 0.01 and ph. Range to ph. Accuracy ± ph

ALPHA II. Innovation with Integrity. The new benchmark for compact FTIR spectrometers FTIR

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

THE STERRAD NX SYSTEM with ALLClear Technology JUST LOAD AND GO MM/DD/YY. System Ready Back 09:00:00 AM. Select Cycle To Begin: Start ADVANCED Cycle

Houston Digital Instruments, Inc. Product Catalog

Cosmetics. Density, Refractive Index, ph and Color Multiparameter Analysis

Automated D. Powder and Liquid Dosing for Perfect Concentrations

4 AA nickel-etal bybrid cells (min. 2,200 mah) Use only AC Adapter (5 VDC / min. 1 A) supplied for recharging

SERIES E L I T - -J. Authorized distributor in Australia:

Particle Size & Shape Analyzer

Screw Plug Heaters - Type IP

Rosemount 1595 Conditioning Orifice Plate

DCT7088 Portable Digital Correlation Transit Time Flowmeter

MARINE MONITORS & PANEL PCs

Transcription:

DMA 4200 M Density Meter for the Petroleum Industry ::: Unique Density & Concentration Meters

The all-rounder for all samples At last there is a density meter which can measure all of your petroleum samples, including crude oil, intermediate products, asphalt, liquefied petroleum gas and high-viscosity liquids: the new DMA 4200 M. This new instrument extends the renowned DMA M range of density meters from Anton Paar and builds on almost 50 years of experience in density measurement. Everywhere Savings Less solvent - Less time and cost Using DMA 4200 M means that tedious, manual and time-intensive measurement with pycnometers or hydrometers is a thing of the past. Filling of even viscous samples is simplified and only 2 ml of sample is needed. After measurement, instead of laborious, solvent-intensive cleaning routines with pycnometers and hydrometers, you just quickly clean the DMA 4200 M sample cell with only a small amount of solvent. Many tasks at many locations DMA 4200 M is a versatile instrument that can be used for a multitude of tasks at multiple locations throughout the petroleum-refining process. Application areas include offshore laboratories, refineries and research and development establishments. DMA 4200 M is a must-have tool for laboratories at petroleum refineries. It improves, accelerates and simplifies density measurements on incoming crude oil, on intermediate samples to give quick feedback to the refining process and for QC of samples like asphalt, bitumen and LPG. All calculations are done for you, there is no need to look up API tables and work out the temperature compensation. This enhances lab productivity while minimizing human error and environmental influences.

Strong A heart stronger than steel Expanded Expanded limits = Extended performance DMA 4200 M extends the measurement limits for digital density measurement in petroleum applications. The measurement temperature can be set at the touch of a button in a wide range from -10 C up to 200 C. Measurement at elevated temperatures in combination with accessories even allows you to measure samples which are solid at room temperature. The density values are automatically calculated for the required reporting temperature. Samples can also be measured under pressures of up to 500 bar. The heart of DMA 4200 M is an innovatively designed and precisely engineered U-tube made of Hastelloy. Hastelloy is a high-performance material. It has a much higher chemical resistance to hydrochloric acid and sour gas than stainless steel. You can rely on this robust instrument for a long life with no risk of breakages or corrosion.

Connectors for a water bath Numerous interfaces DMA 4200 M is not only designed for measurements at high temperatures, but also at temperatures below 0 C. If the measurement is performed at low temperatures, a water bath is connected. DMA 4200 M has 4 USB interfaces, one RS 232 interface and one Ethernet interface. This allows you to connect an external keyboard and a mouse. Excerpt of specifications: Density 0 g/cm 3 to 3 g/cm 3 Density accuracy 0.0001 g/cm 3 Temperature range -10 C to 200 C Temperature accuracy 0.03 C Pressure range Sample amount Footprint U-tube resistance 0 bar to 500 bar 2 ml 33 cm x 51 cm H 2 S, HCl, HF, NaOH

Hastelloy U-tube The U-tube is made of Hastelloy C276, a very robust alloy which is designed for the petroleum industry. Hastelloy is highly resistant to corrosion from e.g. sour gas, hydrochloric acid, hydrofluoric acid, etc. Connectable pressure transducer When a pressure transducer is connected to DMA 4200 M the pressure reading is displayed on the main screen and used for calculations. Strong Peltier elements The Peltier temperature control system of DMA 4200 M only consumes a fraction of the power compared to heating equipment such as oil baths which are conventionally used with hydrometers and pycnometers. Versatile sample introduction A wide range of samples can be inserted into DMA 4200 M. The LPG is injected by connecting the LPG vessel to the LPG adapter. Asphalt/ bitumen or other heavy samples are heated up in the external heating block and the sample is measured at elevated temperatures. Big touchscreen: 10.4 PCT/PCAP The very large touchscreen uses projected capacitive technology (PCT/PCAP). It is easy to operate even when wearing gloves. The slightest contact with your finger activates the touchscreen, which shows up to 12 results in easy-to-read font size.

DMA 4200 M is the all-rounder for all types of petroleum samples. Density measurement of intermediate samples and process samples. Density measurement of end products. Density measurement of the incoming crude oil and live crude oil. LPG asphalt bitumen marine fuel oil No. 6 fuel oil No. 5 fuel oil, bunker fuel bunker C heavy fuel oil (HFO) medium fuel oil (MFO) furnace fuel oil (FFO) navy special fuel oil (NSFO) residual fuel oil crude oil live crude oil RMH 380 RMK 380 RMH 700

Will DMA 4200 M be corroded by the sour gas and hydrochloric acid in the petroleum sample? The U-tube of DMA 4200 M is made out of Hastelloy C276. This alloy is resistant to sour gas and hydrochloric acid and therefore ideal for all petrochemical applications. I have very hard, heavy and highly viscous samples. Do I have to worry about breaking the U-tube? AQ The U-tube is made of metal (Hastelloy C276) and withstands pressures up to 500 bar. It is practically unbreakable. What can I do to measure the density of my bitumen/asphalt, which has a melting point above 130 C? With the external heating block you can melt the bitumen/asphalt and measure the density at 130 C or higher, if needed. I need a high sample throughput of heavy samples, can I use DMA 4200 M? DMA 4200 M measures your heavy samples 4 times faster than a hydrometer or pycnometer. The cleaning routine is also considerably quicker. What is the benefit of using DMA 4200 M compared to a hydrometer? DMA 4200 M needs only 1 to 2 ml of sample. This makes the pre-heating of the sample and cleaning of the instrument much faster than with hydrometers. The cleaning routine needs much less solvent. I want to measure my LPG, can I use DMA 4200 M? DMA 4200 M has a special accessory for measuring the density of LPG: the LPG adapter. This adapter is the connection between the LPG pressure vessel and the density meter and ensures proper filling of DMA 4200 M. Are the density results from DMA 4200 M viscosity-corrected? The DMA 4200 M density reading is the true density. The viscosity influence is compensated by a patented method.