MAXDTC-BT Family User Manual

Similar documents
Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Measure & Control Temperature & CO2 levels with analog & digital I/O

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

OPERATION INSTRUCTIONS

4-step Chiller and Heat Pump Controller

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

Trident and Trident X2 Digital Process and Temperature Panel Meter

IntesisBox ModBus RTU Fujitsu Air Conditioning

Series SD-3PB Digital THERMOSTAT + TIMER

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Millenium II +: general characteristics

Lab and Central Plant Controller

clarity 3 Programmable Controller

SCC Inc. TS Series Application Guide. Technical Instructions. Document No. TS 8000 January 9, Description

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER

7-day room temperature controller

DC Cooling Unit MODEL : TDC 500A / TDC 300A

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

FCU-4 FAN COIL CONTROLLER

IntesisBox PA-AW-MBS-1 v.2.0

TC-9102 Terminal Controller

REMOTE CONTROL MYSYSTEM

Application program: description and examples

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

Basic Temperature and Limit Controllers

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

QK-W016 WiFi Remote Controller WiFi temperature data logger & remote controller

Instruction Sheet Board Style Low Water Cutoff

Dim levels for each system output may be controlled by any of the following methods:

Andover ContinuumTM Infinet II

Quick Start Installation and User Manual

TC-8900 Controller Units with PM-8900 Power Modules

IntesisBox PA-AC-MBS-1

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

VMB1RY. Relay Module for VELBUS system. Velbus manual VMB1RY edition 1 rev.1.0

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

Voltage Current Front-mounting bracket

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

Environmental Chamber Programmer/Controller

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

Field selectable application type and room module series, via dip-switches on controller

System 450 Modular Electronic Controls Catalog

M1000 INTELLIGENT ZONE CONTROL SYSTEM

AirPatrol WiFi Version 2 Full Manual V4.2

Temperature controller Ducted systems

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

BACnet. b3810 Series Local Controllers

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Dip Switch settings.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

FX 2 Instruction Manual

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

Model: Available in : Sapphire Black and Glacier White

Connecting to your Caravan or Motorhome

Instruction Manual CTC-1

Andover ContinuumTM Infinet II

SmartFan Cirrus-9. Speed Control and Alarm for 4-Wire Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

Dieter Wirth, Mess & Regeltechnik Neidlingen

Millennium Simplicity Elite Parameter Points and Quirks

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

Product Data. Features/Benefits. 50RLP Water Source Heat Pumps System Control Panel

Operations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System

Weekday / weekend room temperature controller

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Product Manual SZ2141

CDD Carbon Dioxide Transmitter

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

1/7. Field settings table [6.8.2] =... ID66F2 / ID66F3. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes 4P E

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

Non-communicating room controllers

LX Series Free Programmable Controllers

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Product Manual SZ2144

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

Software Installation Guide. Version 1.1

BACnet Controller for General-purpose Building Applications

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

FC-DIN DIN-Rail Mount Fan Speed Controller

Model: Available in : Sapphire Black and Glacier White

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

RTD-W Installation Instructions

M2 OLED Temperature Monitor Instructions PN 1841

ETM-2050/ETM-2051 Service Manual

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Multi-Point Gas Detection and Control System

Smart Equipment Controls (SEC)

Contents 1 Warnings, Cautions, and Notes Description Features... 1

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

Andover ContinuumTM Infinet II

External level devices for conductive point level switch

This document describes the features and functional specifications of the ECONO3 air conditioner controller.

MANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.

Transcription:

MAXDTC-BT Family User Manual Description The MAXDTC-BT is a fully programmable industrial temperature controller. The controller is configurable and monitorable thru a Bluetooth connection from your Android bluetooth enabled smartphone or tablet. The MAXDTC6-BT can run 6 independent programmable temperature control rules. The MAXDTC2-BT can run 2 programmable temperature control rules. All controllers have FLASH memory for saving and restoring configuration after power loss. The controllers have either 2 or 6 external temperature sensor inputs (-40F - 300F / -40C - 150C) and 2 or 6 dry relay contact outputs (120/240VAC @ 3A, 0-30VDC @ 3A) for switching MAXDTC-BT User Manual - Rev A www.mydtcstore.com 1

both AC and DC loads depending on model. The controllers are din rail mounted and powered by 12VDC. They have gray ABS enclosures and screw terminal for all connections. Applications Differential Heating and Cooling (Solar hot water heating, root cellar cooling, attic cooling) Industrial Heat and Cool Thermostat/Alarming (-40F - 300F / -40C - 150C setpoints) Outdoor Reset Control for Wood Boilers, with programmable one shot restart timer Multi Input/Output Industrial Temperature Alarming Remote control of all outputs from smart phone with one shot timer capability. Greenhouse / hydroponics temperature control and alarming Device Capabilities Number of Control Rules Supported MAXDTC2-BT MAXDTC6-BT Differential Temperature Control (Solar Heating or Root Cellar / Attic Cooling) (2 Inputs / 1 Output) Thermostat (Heat or Cool) (-40-300F range) (1 Input / 1 Output) Outdoor Reset Control (wood stove boiler) (2 Inputs / 1 Output) Periodic Timer (0 Inputs / 1 Output) 1 3 2 6 1 3 2 6 Manual On/Off 2 6 Time Controlled One-Shot Boiler Reset / Remote Control Timed Run 2 6 MAXDTC-BT User Manual - Rev A www.mydtcstore.com 2

Controller Specifications Specifications Relay Outputs: 0-240VAC/ 0-30VDC, 3 amps Temperature Inputs: -40F - 300F Range, NTC 10K thermistor 1% Power Input Voltage: 12vdc nominal (10.8V - 14V) Power Input Current: 40mA + 16.7ma per active relay Mounting: DIN RAIL Indicator: Green LED Communication: Bluetooth 2.0, Range: ~50ft line of site (nominal) Configuration Memory: Non-Volatile, power fail safe Enclosure / Size: MAXDTC2-BT: ABS/PC Blend, Gray, 1.429" L x 3.551" W (36.30mm x 90.20mm) X 2.264" (57.51mm) MAXDTC6-BT: ABS/PC Blend, Gray, 2.795" L x 3.551" W (70.99mm x 90.20mm) X 2.264" (57.51mm) MAXDTC-BT User Manual - Rev A www.mydtcstore.com 3

Installing a Bluetooth Terminal Program In order to communication with the MAXDTC-BT controllers, you will need to load a Bluetooth Terminal program on your android smartphone or tablet. The program is free and can be downloaded for the Google Play Store. The program that works best is Bluetooth Terminal HC-05 from mightyit. You can search for it and download it from the Google Play Store. Here is a link for it as well: https://play.google.com/store/apps/details?id=project. bluetoothterminal&hl=en First Connect to Bluetooth with Android Before you can connect to the controller via the Bluetooth Terminal HC-06 program, you need to connect to the controller via the Bluetooth settings on your phone. You can navigate to the Bluetooth settings screen by going to Settings then selecting Bluetooth. Once here, have the phone or tablet check for available devices. You will want to have the controller powered up for a minute before doing this. When you scan for available devices, you should be able to find the controllers onboard bluetooth device which shows up as HC-06 or BT04-A. Once you see this, go ahead and select it to connect to the device. Once your phone has found and connected to the controller in this way, you are ready to connect to the controller with the Bluetooth Terminal HC-05 application. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 4

In the bluetooth settings go ahead and pair with the discovered HC-06 device. You will need to enter a password to do this. The password for the HC-06 and BT04A bluetooth is 1234. After pairing with the controllers bluetooth, you are ready to connect to it with the terminal application program. Assuming you have loaded the serial terminal program, go ahead and run the Bluetooth Terminal HC-05 application.. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 5

Here is the Bluetooth terminal application on one of the startup screens on the phone. When you run it you should see a connection choice for HC-06 or BT04-A like below if your have connected with the phone s bluetooth settings previously. After running the app it will show you a list of paired devices. Select the HC-06/BT04-A device. Once selected, the smartphone will attempt to connect to the controller. It should flash a connecting / connected message and take you to the terminal screen like shown below. Go ahead and tap the enter command tab and hit an s and then the Send button. The controller should respond with a S tatus display and the main menu. At this point you can monitor and configure your controller thru the application. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 6

Configuring the Controller Differential Heating and Root Cellar Modes (DIFF / ROOT) These modes are used for solar hot water and air heating and root cellar or attic cooling. DIFF mode is used for heating. ROOT mode is used for differential cooling applications like root cellars.. Configure Differential or Root Cellar Menu Descriptions Value Range Select Output to Configure (1-6): 1-6 Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF 5-ROOT, 6-RESET, 7-CYCLIC Select Collector Temp Sensor (1-6): (ROOT Mode) Select Outside Temp Sensor (1-6): 4-5 1-6 Select Storage Temp Sensor (1-6) or (Root Mode) Select Cellar Temp Sensor (1-6): 1-6 Enter DeltaT TurnOn Degrees (1-99): 1-99 Enter DeltaT TurnOff Degrees (1-99): 1-99 Enter Max Tank Temp (0-255) or (Root Mode) Enter Min Cellar Temp (0-255): 0-255 Enter Freeze Protection? (1-yes, 0-no) or (ROOT Mode: None) 0-1 MAXDTC-BT User Manual - Rev A www.mydtcstore.com 7

Outdoor Reset Mode (RESET) Outdoor reset mode is used to automatically adjust the setpoint for a wood boiler based on outdoor temperature. The controller will automatically adjust the setpoint higher when the outside temperature gets very cold as well as reduce the setpoint when the outdoor temperature warms up. This reduces wood consumption and enhances comfort. Reset_setpoint = 70 + ( ( 70 - Outside Temp ) * SLOPE / 10) - Fahrenheit Reset_setpoint = 21 + ( ( 21 - Outside Temp ) * SLOPE / 10) - Celsius Here is a link to a spreadsheet for comparing calculated setpoints vs outside temperature and the slope setting: https://docs.google.com/spreadsheets/d/1uj_t8kyjokdhtvgsxukm8cq8c06ritzfjorutodk3fk /edit?usp=sharing Configure Outdoor Reset Menu Descriptions Value Range Select Output to Configure (1-6): 1-6 Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF 5-ROOT, 6-RESET, 7-CYCLIC 7 Select Outside Ambient Temp Sensor (1-6): 1-6 Select Boiler Temp Sensor (1-6): 1-6 Enter Slope Value (x10) (1-99): 1-99 Enter Reset Hysteresis (1-99): 1-99 Enter Maximum Boiler Temp (0-255): 0-255 Enter Minimum Boiler Temp (0-255): 0-255 MAXDTC-BT User Manual - Rev A www.mydtcstore.com 8

Thermostat Heat and Cool Modes (HEAT / COOL) Configure COOL / HEAT Thermostat Menu Descriptions Value Range Select Output to Configure (1-6): 1-6 Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF 5-ROOT, 6-RESET, 7-CYCLIC 2 or 3 Select Thermostat Temp Sensor (1-6): 1-6 Select Setpoint Temperature (-40-300F): -40-300 Enter Hysteresis / Dwell Degrees (1-99): 1-99 Use HEAT or COOL mode to provide thermostat heating or cooling or provide temperature alarming for motors or refrigeration. Setpoints from -40F to 300F (or celsius equivalent) are supported by the controller. Programmable Hysteresis and Dwell temperature from (0-99F) (or celsius equivalent) is also provided to adjust the run time and depth of temperature cycling required. The inputs sensor selection for these modes will allow multiple thermostats to be controlled by the same temperature input if desired for controlling multiple output devices from one sensor. The controller will print Saving to Memory when the settings are committed to memory. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 9

Cyclic Timer Mode (CYCLIC) Configure Cyclic Timer Menu Descriptions Value Range Select Output to Configure (1-6): 1-6 Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF 5-ROOT, 6-RESET, 7-CYCLIC 7 Enter Cyclic On Time (1-32000): 1-32000 Enter Cyclic Off Time (1-32000): 1-32000 Cyclic Timer is used for things like hot water recirculation pumps, misting systems, buffer tanks. Configure the On time in seconds followed by the off time in seconds. The controller will turn the output on for the on time setting, then off for the off time setting then repeat. The controller will print Saving to Memory when the settings are committed to memory. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 10

Changing the Controller Preferences Preferences Menu Descriptions Value Range Enter Temperature Units (0-Fahrenheit, 1-Celsius): 0-1 Enter One Shot Time Seconds (1-32000) 1-32000 In preferences you can change the temperature units that the controller uses to display the temperature sensors. It will not automatically change the parameters you have entered when changing units. You will have to change those setting manually. The settings will not be saved to nonvolatile memory until you have changed all the settings in the menu group (Temperature Units, One Shot Time Seconds). The controller will print Saving to Memory when the settings are committed to memory. This configuration screen is activated by entering a p character. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 11

Status and Monitoring the Controller Info Screen The Info screen provides the SW revision of the controller, Total Runtime in hours and days, Runtime since last reset, currently selected temperature units and one shot timer seconds configured. This screen is activated by entering a i character. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 12

Rules Screen The rules screen shows a snapshot of all the relay control rules you have entered and their parameter values. It is accessed by entering an r at anytime. The rules screen shows the mode, temperature inputs selected, setpoints and parameters for each relay control rule configured. For outdoor reset it also shows the calculated reset setpoint temperature. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 13

Status Screen The status screen shows a snapshot of all the relay control inputs temperatures and output state for each relay. It is accessed by entering an s at anytime. It shows the controlling variables and any overtemp / under-temp status states. As an example below the R1: Root Cellar Mode, O utside and C ellar temps (O/C) are shown, the calculated deltat, and output relay is OFF. Across the top it shows current temperature readings of all inputs. From there is shows the relay control rules configured mode, controlling input values, and relay output state at the end. If an under or over temp state is overriding the control rule it will show which one. On R6 a reset control rule is setup and MINT value indicates that the minimum temperature is being violating and forcing the output on. The RSP value is the reset setpoint calculated and being used based on the ambient temperature and slope you have selected. This value is bounded by the Min Temperature and Max temperatures you configured for the rule. You will see a trigger one shot status with amount of time left if you do a one shot trigger on any of the outputs in this display as well. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 14

History Screen The history screen displays the high and low temps read on the inputs since the last history reset. They are displayed in the units you have selected in the preferences. It is accessed by entering an h at anytime. Hitting a 1 at the prompt resets the high and low readings to current readings. Power LED The green LED should like and blink once a second when the controller is operating properly. If the LED is not lit, check the power inputs and verify you are providing +12VDC and Ground to the power inputs located next to the LED. Verify polarity is correct. When power is first applied, it can take approximately 6 seconds to initialize. Installation and Wiring Info Temperature Sensor Inputs and Wiring The temperature sensors sold with the controller are matched in characteristic to the controller and will provide the most accurate readings. Using other 10K NTC thermistors is not recommended. There are water-proof versions of the temp sensor available as well. Temperature sensors may be extended 50 ft with twisted pair telephone cable or CAT5 cable without dramatically affected the reading accuracy. Do not include power wiring in the bundle to other devices as it may put noise on the temperature reading. Always separate measurement sensor wiring from power / load device power wiring where possible. The sensor inputs are wired with a common terminal between each two inputs. This common wire should have one wire from each temp sensor input adjacent to it. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 15

Temperature Sensors for MAXDTC-BT Controller There are two types of temperature sensors available for use with the MAXDTC-BT. The Standard Temp sensor and a waterproof temp sensor are both available from the website. These sensors are matched to the controller and will provide the most accurate readings. Each controller comes with two standard temp sensors. Additional sensors are available for purchase off the wesite: www.mydtcstore.com MAXDTC-BT User Manual - Rev A www.mydtcstore.com 16

Power Input (12VDC) The power input to the controller requires 12VDC input, which is on the top right side of the controllers. It is recommended to use a DIN rail type 12vdc power supply with a well regulated output for the best performance and reliability of the controller. These are available off the website, but do not come standard with the controllers. If you need to run large DC pump, you will need to have a higher current capacity power supply (3-5 Amp recommended). These supplies have an adjustable output voltage trimmer as well. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 17

Controller Output Relay Wiring to Load Devices Wiring load devices to the controller relay outputs is simple. Connect the Hot or Positive power source wire to one side of a relay output, connect the other side of the relay output to the Hot or Positive power input of the load device. The controller will switch the power to the load device by closing the relay. It s always a good idea to put a fuse on the output of the controller to the input of the load device. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 18

Controller Temperature Sensor Wiring The temp sensors are wired to T1-T6 sensor inputs (T1-T2 on smaller MAXDTC2-BT version). Each group of two temperature sensor inputs shares a common ground terminal that both temperature sensors share in common. See diagram. The temperature sensors can be extended 50ft with twisted pair telephone wire or equivalent CAT5 type cable with no appreciable reading error. Avoid running temperature sensor wires near AC or power connections to load devices which can create noise on the temperature sensor input. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 19

External DIN Rail Relay Info If you need to switch larger power loads than the 5amp onboard relays can handle, consider purchasing an external DIN rail mountable relay and control it with the onboard controller relay. Just switch 12VDC power to the external relay coil to support upto 10A load devices. MAXDTC-BT User Manual - Rev A www.mydtcstore.com 20

Ordering Information and Pre-configuration Options MAXDTC-BT Controllers can be ordered off the www.mydtcstore.com website. More information and accessory equipment such as additional temperature sensors, waterproof sensors, fuses, DIN rail power supplies, terminal blocks, additional DIN rail, and external high current relays are available for purchase on the website. If you would like the controller preconfigured to your application before shipment, please contact us for details. For OEM inquiries, contact Brian Smith at this email address: smith100griggs@gmail.com. Have Technical Questions? Send us an email! Have a question on how the controller works? Send me an email and I will try to answer your question: Brian Smith - smith100griggss@gmail.com MAXDTC-BT User Manual - Rev A www.mydtcstore.com 21