S93-8 Page 1 TOMOGRAPHIC APPROACHES TO NONWOVENS STRUCTURE DEFINITION

Similar documents
Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

FIELD PARADIGM FOR 3D MEDICAL IMAGING: Safer, More Accurate, and Faster SPECT/PET, MRI, and MEG

Biophysical Techniques (BPHS 4090/PHYS 5800)

3D X-ray Microscopy Characterization. Metal Additively Manufactured Parts. Application Note

Single Slit Diffraction

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

Image Reconstruction from Multiple Projections ECE 6258 Class project

imorph : A 3D morphological tool to fully analyze all kind of cellular materials

Digital Volume Correlation for Materials Characterization

Recognition and Measurement of Small Defects in ICT Testing

3D Computed Tomography (CT) Its Application to Aerospace Industry

Digital Image Processing

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

Correction of refraction. volume deformation measurements

Phase problem and the Radon transform

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

THE EVOLUTION AND APPLICATION OF ASYMMETRICAL IMAGE FILTERS FOR QUANTITATIVE XCT ANALYSIS

Advanced Image Reconstruction Methods for Photoacoustic Tomography

X-ray MicroCT in Conjunction with Other Techniques for Core Analysis

The Curse of Dimensionality. Panagiotis Parchas Advanced Data Management Spring 2012 CSE HKUST

Medical Imaging Introduction

Simpleware: Converting 3D Images into Models for Visualisation, Measurement and Computational Simulation

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

To make sense of data, you can start by answering the following questions:

THE INSIDE VIEW IN THIS ISSUE INTRODUCING: CUSTOM M8000 X5000 X500 X50 IMAGIX. Portfolio Includes: and CT Product. NSI S X-ray

Creating an Automated Blood Vessel. Diameter Tracking Tool

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Method for Quantifying Percentage Wood Failure in Block-Shear Specimens by a Laser Scanning Profilometer

DENOISING OF COMPUTER TOMOGRAPHY IMAGES USING CURVELET TRANSFORM

Characterization of Powder Injection Molded Components Using X-Ray CT. David P. Harding, Zhigang Zak Fang, C.L. Lin, Jan D. Miller

XRADIA microxct Manual

Translational Computed Tomography: A New Data Acquisition Scheme

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Design and Construction of Relational Database for Structural Modeling Verification and Validation. Weiju Ren, Ph. D.

Compressed Sensing for Electron Tomography

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

Comparison of fiber orientation analysis methods in Avizo

Super-resolution Reconstruction of Fetal Brain MRI

ADVANCED IMAGE PROCESSING METHODS FOR ULTRASONIC NDE RESEARCH C. H. Chen, University of Massachusetts Dartmouth, N.

DIGITAL TERRAIN MODELS

Extracting Woven Yarns of Ceramic Matrix Composite Parts With X-ray CT Scanning

Index. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting

Predicting the mechanical behaviour of large composite rocket motor cases

NDT of a Composite Using MicroCT Data and Image-based Finite Element Modelling

MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM

Radiographic Simulator artist: Version 2

Temperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System

BME I5000: Biomedical Imaging

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Image Acquisition Systems

Epipolar Geometry CSE P576. Dr. Matthew Brown

Nearest approaches to multiple lines in n-dimensional space

Chapter 3 Geometrical Optics

Werkstoffmodellierung und eigenschaftsberechnung auf Basis von CT-Aufnahmen

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING

Scientific Visualization. CSC 7443: Scientific Information Visualization

2018 Technical Review Waruna Seneviratne, John Tomblin, and Supun Kariyawasam

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Automated segmentation methods for liver analysis in oncology applications

Comparison of Vessel Segmentations using STAPLE

Image Reconstruction in Optical Tomography : Utilizing Large Data Sets

Quantitative Image Analysis and 3-D Digital Reconstruction of Aortic Valve Leaflet

A NUMERICAL EXPERIMENT ON NONLINEAR IMAGE RECONSTRUCTION FROM FIRST-ARRIVAL TIMES FOR TWO-DIMENSIONAL ISLAND ARC STRUCTURE

APPLICATION OF RADON TRANSFORM IN CT IMAGE MATCHING Yufang Cai, Kuan Shen, Jue Wang ICT Research Center of Chongqing University, Chongqing, P.R.

The computer training program on tomography

Reflection and Refraction

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

COMPUTATIONAL CHALLENGES IN HIGH-RESOLUTION CRYO-ELECTRON MICROSCOPY. Thesis by. Peter Anthony Leong. In Partial Fulfillment of the Requirements

Computer Graphics. - Volume Rendering - Philipp Slusallek

DUE to beam polychromacity in CT and the energy dependence

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Improvement of contrast using reconstruction of 3D Image by PET /CT combination system

A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals

3-D Compounding of B-Scan Ultrasound Images

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

Scaling Calibration in the ATRACT Algorithm

Computed Tomography for Industry Needs and Status Umesh Kumar

RADIOMICS: potential role in the clinics and challenges

Computed tomography of simple objects. Related topics. Principle. Equipment TEP Beam hardening, artefacts, and algorithms

Coordinate Measuring Machines with Computed Tomography

Evaluation of 3D fiber orientation analysis based on x-ray computed tomography data

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS

Classification of Abdominal Tissues by k-means Clustering for 3D Acoustic and Shear-Wave Modeling

Volume Reconstruction and Parallel Rendering Algorithms: A Comparative Analysis

Improving Network Infrastructure to Enable Large Scale Scientific Data Flows and Collaboration (Award # ) Klara Jelinkova Joseph Ghobrial

MEDICAL IMAGE ANALYSIS

Multiple View Geometry in Computer Vision

Recovery of Piecewise Smooth Images from Few Fourier Samples

Organ Surface Reconstruction using B-Splines and Hu Moments

Quality control phantoms and protocol for a tomography system

Acknowledgments and financial disclosure

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

Dimensional Measurement of Nuclear Fuel Pellets using High Energy X-ray CT

Transcription:

S93-8 Page 1 TOMOGRAPHIC APPROACHES TO NONWOVENS STRUCTURE DEFINITION PIs: T. Gilmore, H. Davis, Z. Mi, North Carolina State University Code: S93-8 Date of Report: 9/94 RELEVANCE TO NTC MISSION AND GOALS: The thrust of the tomographic approaches project is to better understand the structure of thick, three-dimensional nonwoven structures, many of which have high-performance applications. Better understanding of the structure will lead to improvements in products, product performance, and in the technologies for manufacturing these products. In order to facilitate this project, we have obtained the participation of personnel and facilities at The Center for In Viva Microscopy at Duke University Medical Center (DUMC) (MRI) and at Oak Ridge National Laboratories (ORNL) (micro X-ray tomography). By involving personnel and facilities at these laboratories, which generally have not been involved in textile-related projects, we are pursuing a unique, collaborative effort. We will also be taking advantage of highly sophisticated imaging facilities not yet available on the NCSU campus. In a development which will make this technology available to academic and industrial researchers, NCSU is expected to build a synchrotron ( STAR ) on the Centennial Campus sometime in the next five years. We have been told that micro X-ray tomography images will be available from this facility at a cost of around $2OO/specimen. We expect this technology to be useful in the analysis of conventional textile structures as well as nonwovens. GOALS: The goal of this project is a technology which permits the visualization and quantification of the three dimensional structure of a thick nonwoven fabric of arbitrary density based on tomography. The technology will combine methods for obtaining experimental tomographic data having adequate resolution with methods for analyzing the data to give the desired statistical structural parameters. The results desired are 1) the ability to visualize the structure via tomographic slices, and 2) the three-dimensional orientation distribution function for the fibers and a characterization of the internal void space. DETAILS: While the technology for obtaining and reconstructing tomographic data on macroscopic specimens, e.g. human organs, is highly developed (CT scans, MRI), for the most part evaluation of these data relies only on qualitative subjective observation by a specially trained radiologist. While there is a large literature on quantitative two-dimensional image analysis of fibrous structures, there is little for three-dimensions. The experimental techniques available to us are serial sectioning (very time-consuming for high z-direction resolution), confocal microscopy, and tomography. In general, the methods for National Textile Center Annual Report: September, 2994 299

S93-8 Page 2 obtaining the data provide relatively low resolution compared with the size of a single fiber in a nonwoven, or require considerable time and manpower. Based on a literature survey, it was decided to evaluate magnetic resonance imaging (MRJ) and micro x-ray tomography for obtaining the raw tomographic data. Also based on the literature survey, it was decided to initially base analysis methods on extending the two-dimensional morphological image analysis methods to three-dimensions. These methods are being developed within the commercial software Applications Visualization System (AVS). A DEC workstation with 24 megabytes of memory was purchased for the project and is dedicated to software development and image analysis. Following our development of the sample preparation technique, Dr. Alan Johnson of the Center for In Vivo Microscopy at Duke University Medical Center has provided us with a data file containing the tomographic image of a paper-maker s felt. We have learned to manipulate these data so the image can be viewed using NIH imaging software on a MacJntosh computer, although, due to the size of the file, memory constraints have caused problems. The initial specimen to be analyzed is a needlepunched papermaker s felt provided by Weavexx Corporation. Papermaker s felts are dense, strong, and durable felts made by needlepunching a needle felt into a woven monofilament scrim. The monofilament scrim provides the dimensional stability needed in paper machine applications. For our purposes, the monofilament, which has a much larger denier than the needled fibers, provides a landmark for use in visualization. Theoretical analysis and the development of algorithms and software are the keys to success of this work. Applying and demonstrating the Hilliard/Komori-Makishima theory in order to quantify the ODF is the immediate goal now that tomographic data is available. The problem of resolution is being addressed. The 3 denier fibers in this felt have a diameter of approximately 15 microns. The MRI resolution is 20 microns. Therefore, special algorithms are being developed to identify a fiber (separate from noise), and to provide its location. Theoretical Background: According to the Hilliard/Komori-Makishima (HKM) theory, the three-dimensional orientation distribution function (ODF) of a fibrous structure can be obtained by solving the integral equation: _ v(o,cp) = Lj_/d$de A(@;@,@) Q($,e) sin0 (1) where v(o,@) P fiber intersections per unit area on plane with normal [@,@I L = total length of fiber in a unit volume = 1/7c ~~v(o,@)sinododq A(@);@@ > = 1 sin0 sin0 cos(q - @) + c0se cos0 1 (2) Q(e,$) = jiber orientation distribution function in spherical coordinates 300 National Textile Center Annual Report: September, 2994

S93-8 Page 3 The normalization condition is II R(B,@>sineded+ = 1. Q@,$)sine is the function we desire from the experimental data. An estimate of Q(e,Q)sin9 is obtained by counting the number of fiber intersections in a large number of unit area planes, then numerically solving (1). This part of the project has been completed. Implementation: To analyze the raw tomographic data, the following steps are required: 1. Process the data to remove noise. 2. Count the intersections of fibers with secant unit area planes with various normals Kwl. 3. Solve the HKM equation for R using a two-dimensional Fourier series approximation. 4. Implement a least squares method to solve for Fourier coefficients up to fifth order. These steps have been implemented and the procedure and algorithms confirmed on a number of simple computer-generated model structures. A road block was encountered when we found that the method involves inverting a matrix which is nearly singular. However, this was overcome with standard singular value decomposition (SVD) numerical methods. Analysis of Model Structures: Four model structures were developed using straight fibers: Model I: all fibers parallel to the Y-axis Model II: all fibers parallel to the X-axis Model III: all fibers parallel to the Z-axis Model IV: equal numbers of fibers parallel to the X- and Y-axes The number of intersections were counted for ten sets each of unit secant planes at 10 degree increments of 0 and @. Equation (1) was solved numerically for Q@,+)sin@. Figure 1 shows the results for the number of intersections for Model I, while Figure 2 shows the ODF for Model I. We investigated third to fifth order Fourier solutions to Equation (1). The number of terms requiring calculation increases rapidly as the order increases: 48 terms for 3rd order, 80 for 4th, 120 for 5th, etc. The results seen in the four models are intuitively correct. If it were possible to use a larger number of terms, the peak shown in Figure 2 would more closely approximate a delta function a closer approximation of the ODF for a bundle of straight parallel fibers. Since ODF s in nonwovens are never delta functions, we are confident that a solution higher than fifth order will never be needed. National Textile Center Annual Report: September, 1994 302

S93-8 Page 4 Analysis of Real Fabrics: Using tomographic data provided by DUMC, the procedure has been applied to a real fabric. Tomographic slices of this fabric are shown in Figure 3. A preliminary predicted ODF based on 5th order Fourier analysis is shown in Figure 4. WHAT HAS BEEN ACCOMPLISHED: The theoretical analysis has been developed using advanced computation techniques, and has been demonstrated for four simulations of known fiber orientation. The ODF response surface for these four simulations appear to be correct. Techniques have been developed and implemented to process the raw MRI image data: file handling, noise reduction, and filtering. Techniques to identify individual fibers in the image data have been developed. Sample preparation techniques have been developed, and MRI tomographic imaging data have been generated at Duke University Medical Center on a dense three-dimensional needle felt. Micro X-ray tomographic images have been generated at ORNL but the results have not been forwarded to us yet. The MRI image data has been processed, and transformed for viewing and manipulation. The data have been analyzed and an ODF response surface generated. Image resolution continues to be our main concern. If imaging with micro X-ray tomography is successful, resolution potential could be improved from the current 20 microns for MRI to 3 microns. PLANS: Process the higher resolution micro X-ray tomography data generated at ORNL using the paper maker s felt to determine the applicability of this imaging technology: view the image, choose a portion of it for analysis, and determine the three-dimensional ODF. Verify the analysis by making a model structure of known ODF (thick layered cardweb) and determining the ODF using MRI and micro X-ray tomography. Verify using a thick woven fabric. Work with ORNL to optimize the electron density contrast to achieve best tomographic images of thick nonwoven fabrics using micro X-ray tomography. Begin developing systems for analyzing internal pore structure from tomographic data. Select additional thick structures of interest to the industry, and apply and refine the technique on those structures. Publish a paper descriptive of work to date. 302 National Textile Center Annual Report: September, 1994

S93-8 Page 5 RESOURCE MANAGEMENT: Coordinator: T. Gilmore, NCSU Computer Analysis: 2. Mi, NCSU Liaison with Outside Labs: H. Davis, NCSU Theoretical Analysis: H. Davis and Z. Mi, NCSU Center for In Viva Microscopy, Duke University Medical Center: A. Johnson Oak Ridge National Laboratory: W. Brosey Figure 1: Number of Intersections of Model I Figure 3. Tomographic slice through a vertical plane of a papermaker s felt. The reorientation of fibers due to a needle penetration can be seen in the center of the image. National Textile Center Annual Report: September, 1994 %3

S93-8 Page 6 Figure 2: Orientation Distribution Function of Model I Z Figure 4: Orientation Disbibution Function of Real Fabric 7 Yl t!- I, I 0 Y 304 National Textile Center Annual Report: September, I B94