PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Similar documents
PNOZ m ES ETH. Configurable Control System PNOZmulti. Operating Manual EN 04

PNOZ m EF PDP Link. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m ES EtherCAT. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m ES Profinet. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m EF Multi Link. } Configurable control systems PNOZmulti 2. Operating Manual EN-04

PNOZ mc4p. } Configurable safety systems PNOZmulti. Operating Manual EN-05

PNOZ s1. Safety relays. Operating Manual EN-07

PNOZ m ES EtherNet/IP. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m ES EtherNet/IP. } Configurable control systems PNOZmulti 2. Operating Manual EN-04

PNOZ ml1p. PNOZmulti Modular Safety System. Operating Manual No EN-05

Operating Manual PNOZ mc3p. Operating Manual PNOZ mc3p. PNOZ mc3p. Configurable Control System PNOZmulti. Operating Manual No.

PNOZ s2. Safety relays. Operating Manual EN-07

PNOZ s9. Safety relays. Operating Manual EN-08

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PNOZ mc6p, PNOZ mc6.1p

PNOZ ms1p. Configurable Control System PNOZmulti. Operating Manual EN 11

PNOZ m B0. Configurable Control System PNOZmulti. Operating Manual EN 04

Operating Manual PDP67 F 8DI ION. Operating Manual PDP67 F 8DI ION PDP67 F 8DI ION. Decentralised periphery. Operating Manual No.

PNOZ m B0. } Configurable control systems PNOZmulti 2. Operating Manual EN-05

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

PSS(1) Ethernet Hardware

PNOZmulti PNOZmulti Mini

PNOZ X2.1. } Safety relays. Operating Manual EN-05

Faults on the system Proximity switch connection technology:

PNOZ X1. } Safety relays. Operating Manual EN-08

_Name_Bookmark2_. _Name_Bookmark2_. PNOZmulti Modbus/TCP. PNOZmulti Modular Safety System. Operating Manual No EN-01

System expansion. Configurable Control System PNOZmulti. Operating Manual EN 08

PNOZmulti Installation Manual. Installation Manual EN-02

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

Programmable Safety Systems PSS -Range

PNOZ s30. Safety relays. Operating Manual EN 14

PMI m309 diag. Operator terminals. Operating manual No EN-02

Serial PROFIBUS Interface

TRIO-DIODE/12-24DC/2X10/1X20

PSEN 1.1p-20. } PSEN sensor technology. Operating Manual EN-10

Safety relays PNOZsigma

Safe timer relay/contact expansion modules

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating Manual PNOZ mm0p. Operating Manual PNOZ mm0p. PNOZ mm0p. Configurable Control System PNOZmulti. Operating Manual No.

E-STOP relay, safety gate monitor

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

C9900-P208 and C9900-P209

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Redundancy unit CP-A RU

Contact expander modules

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 07/2006

Operating instructions. Standstill monitor A / / 2011

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

C9900-P223 and C9900-P224

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

User Manual Gateway component for EtherNet/IP

Operating instructions. Speed monitor D / / 2014

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Operating instructions. Switching amplifier DN0210 DN / / 2015

PSEN cs5.1n. PSEN sensor technology. Operating Manual EN 01

QUINT-BUFFER/24DC/24DC/40

CPCI-PS24 24V-Power Supply

Power supply CP-C 24/5.0

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

PSEN cs3.1n. } PSEN sensor technology. Operating Manual EN-03

AO561 Analog Output Module

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

PSEN cs5.11 M12/8. PSEN sensor technology. Operating Manual EN 01

Redundancy Module QUINT-DIODE/40

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

PHOENIX CONTACT - 05/2007

PSEN cs3.1p/m12. } PSEN sensor technology. Operating Manual EN-04

Safe monitoring relays

CPCI System Subrack 1 U

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Installation manual plugs and connectors with screw connection (16/32 A)

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

CU port USB 2.0 hub. Version: 1.1 Date:

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

3/4 U CPCI Serial Case System

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

AI561 Analog Input Module

PSEN cs5.1 M12/8. PSEN sensor technology. Operating Manual EN 01

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

E-STOP relays, safety gate monitors

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Operating instructions Evaluation system for flow sensors VS / / 2013

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

E-STOP relays, safety gate monitors

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Type Quickstart

Transcription:

PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01

This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz, PIT, PMI, PNOZ, Primo, PSEN, PSS, PVIS, SafetyBUS p, SafetyEYE, SafetyNET p, the spirit of safety are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. SD means Secure Digital

Content Section 1 Introduction 4 1.1 Validity of documentation 4 1.1.1 Retaining the documentation 4 1.2 Overview of documentation 4 1.3 Definition of symbols 5 Section 2 Overview 6 2.1 Unit structure 6 2.1.1 Scope of delivery 6 2.1.2 Unit features 6 2.2 Front view 7 2.2.1 Key 7 Section 3 Safety 8 3.1 Intended use 8 3.1.1 System requirements 8 3.2 Safety regulations 8 3.2.1 Use of qualified personnel 8 3.2.2 Warranty and liability 9 3.2.3 Disposal 9 3.2.4 For your safety 9 Section 4 Function description 10 4.1 Unit properties 10 4.1.1 Block diagram 10 Section 5 Installation 11 5.1 General installation guidelines 11 5.1.1 Dimensions 11 5.2 Connecting the base unit and expansion modules 12 Section 6 Commissioning 13 6.1 Wiring 13 6.1.1 General wiring guidelines 13 6.1.2 Interface configuration 13 6.2 Preparing for operation 13 6.2.1 Download modified project to the PNOZmulti safety system 13 Section 7 Operation 14 7.1 Messages 14 7.1.1 Display elements for device diagnostics 14 Section 8 Technical details 15 Section 9 Order reference 17 3

Introduction 1 1.1 1.1.1 1.2 Introduction Validity of documentation This documentation is valid for the product PNOZ m ES RS232. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Retaining the documentation This documentation is intended for instruction and should be retained for future reference. Overview of documentation 1 Introduction The introduction is designed to familiarise you with the contents, structure and specific order of this manual. 2 Overview This chapter provides information on the product's most important features. 3 Safety This chapter must be read as it contains important information on intended use. 4 Function Description This chapter describes the product's mode of operation. 5 Installation This chapter explains how to install the product. 6 Commissioning This chapter describes the product's commissioning and wiring. 7 Operation This chapter describes how to operate the product and gives tips in the case of a fault. 8 Technical Details This chapter contains the product's technical details and order reference. 4

Introduction 1.3 Definition of symbols Information that is particularly important is identified as follows: DANGER! This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. WARNING! This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. ATTENTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. CAUTION! This describes a situation in which the unit(s) could be damaged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular importance. Information This gives advice on applications and provides information on special features. 5

Overview 2 2.1 2.1.1 2.1.2 Overview Unit structure Scope of delivery } Expansion modulepnoz m ES RS232 } Jumper 779 260 Unit features Using the product PNOZ m ES RS232: Communication module for connection to a base unit from the configurable control system PNOZmulti 2. The product has the following features: } Can be configured in the PNOZmulti Configurator } 1 serial interface RS232 } Status indicator for supply voltage } Max. 1 communication module can be connected to the left of the base unit PNOZmulti 2 } Plug-in connection terminals (either cage clamp terminals or screw terminals) 6

Overview 2.2 Front view Power 2.2.1 Key Key: } X2: Serial interface RS 232 } LED: Power 7

Safety 3 3.1 3.1.1 3.2 3.2.1 Safety Intended use The expansion module PNOZ m ES RS232 is used for communication of the configurable safety relay PNOZmulti 2 via a serial interface RS232. The expansion module may only be connected to a base unit from the configurable control system PNOZmulti 2 (please refer to the document "PNOZmulti System Expansion" for details of the base units that can be connected) The configurable control system PNOZmulti 2 is used for the safety-related interruption of safety circuits and is designed for use in: } E-STOP equipment } Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1 The expansion module may not be used for safety-related functions. Intended use includes making the electrical installation EMC-compliant. The product is designed for use in an industrial environment. It is not suitable for use in a domestic environment, as this can lead to interference. The following is deemed improper use in particular: } Any component, technical or electrical modification to the product } Use of the product outside the areas described in this manual } Use of the product outside the technical details (see chapter entitled Technical Details ) System requirements Please refer to the "Product Modifications" document in the "Version overview" section for details of which versions of the base unit and PNOZmulti Configurator can be used for this product. Safety regulations Use of qualified personnel The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons. A competent person is someone who, because of their training, experience and current professional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology. It is the company s responsibility only to employ personnel who: } Are familiar with the basic regulations concerning health and safety / accident prevention } Have read and understood the safety guidelines given in this description } Have a good knowledge of the generic and specialist standards applicable to the specific application. 8

Safety 3.2.2 3.2.3 3.2.4 Warranty and liability All claims to warranty and liability will be rendered invalid if: } The product was used contrary to the purpose for which it is intended } Damage can be attributed to not having followed the guidelines in the manual } Operating personnel are not suitably qualified } Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). Disposal } In safety-related applications, please comply with the mission time t M in the safety-related characteristic data. } When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). For your safety The unit meets all necessary conditions for safe operation. However, you should always ensure that the following safety requirements are met: } This operating manual only describes the basic functions of the unit. Information on the advanced functions can be found in the online help for the PNOZmulti Configurator and in the PNOZmulti technical catalogue. Only use these functions after you have read and understood the documentation. All necessary documentation can be found on the PNOZmulti Configurator CD. } Do not open the housing or make any unauthorised modifications. } Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). 9

Function description 4 4.1 4.1.1 Function description Unit properties The product PNOZ m ES RS232 has a serial interface RS232 interface to } Download the project } Read the diagnostic data } Set virtual inputs for standard functions } Read virtual outputs for standard functions. Information on diagnostics can be found in the document "Communication Interfaces". Block diagram RS 232 Base unit 10

Installation 5 5.1 Installation General installation guidelines } The unit should be installed in a single mounting area with a protection type of at least IP54. } Fit the safety system to a horizontal mounting rail. The venting slots must face upwards and downwards. Other mounting positions could destroy the safety system. } Use the locking slide on the rear of the unit to attach it to a mounting rail. } In environments exposed to heavy vibration, the unit should be secured using a fixing element (e.g. retaining bracket or end angle). } Open the locking slide before lifting the unit from the mounting rail. } To comply with EMC requirements, the mounting rail must have a low impedance connection to the control cabinet housing. } The ambient temperature of the PNOZmulti units in the control cabinet must not exceed the figure stated in the technical details, otherwise air conditioning will be required. ATTENTION! Damage due to electrostatic discharge! Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive surface or by wearing an earthed armband. 5.1.1 Dimensions 111,0 (4,37 ) 101,4 (4.11 ) 11

Installation 5.2 Connecting the base unit and expansion modules You can install a maximum of 1 PNOZ m ES RS232 to the left of the base unit. Connect the base unit and the expansion module as described in the operating instructions for the base units. } Install the expansion module in the position in which it is configured in the PNOZmulti Configurator. } Connect the base unit and expansion modules using the yellow/black jumper. } Connect the black/yellow terminator to the expansion module. 12

Commissioning 6 6.1 6.1.1 6.1.2 Commissioning Wiring General wiring guidelines The wiring is defined in the circuit diagram of the PNOZmulti Configurator. Note: } Information given in the "Technical details" must be followed. Interface configuration Serial interface RS232 TxD RxD GND Standard TxD (Transmit) RxD (Receive) GND (Ground) 6.2 6.2.1 Preparing for operation The serial interface RS 232 is activated and detected depending on the USB interface on the base unit: } USB interface on the base unit not connected In this case, the serial interface RS 232 will be detected and activated by the base unit as soon as the communication module has been connected to the base unit. } USB interface on the base unit connected If the USB interface on the base unit is already connected, the "External" interface will first need to be selected on the base unit display to enable the serial interface RS 232 on the base unit to be detected and activated (see operating manual for the base unit for details of the setting). Download modified project to the PNOZmulti safety system As soon as an additional expansion module has been connected to the system, the project must be amended using the PNOZmulti Configurator. Proceed as described in the operating instructions for the base unit. CAUTION! For the commissioning and after every program change, you must check whether the safety devices are functioning correctly. 13

Operation 7 7.1 7.1.1 Operation Messages When the supply voltage is switched on, the PNOZmulti safety system copies the configuration from the chip card. The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up on the base unit. The safety system PNOZmulti is ready for operation when the "POWER" and "RUN" LEDs on the base unit and the "POWER" LED on the PNOZ m ES RS232 are lit continuously. Display elements for device diagnostics Legend: LED on LED flashes LED off LED LED status Meaning Power No supply voltage Green Supply voltage is present 14

Technical details 8 Technical details General 772131 Approvals CCC, CE, GOST Application area Standard Electrical data 772131 Supply voltage Module's current consumption 9 ma Module's power consumption 0,3 W Status indicator LED Fieldbus interface 772131 Galvanic isolation No Serial interface 772131 Number of RS232 interfaces 1 Environmental data 772131 Ambient temperature In accordance with the standard EN 60068-2-14 Temperature range 0-60 C Forced convection in control cabinet off 55 C Storage temperature In accordance with the standard EN 60068-2-1/-2 Temperature range -25-70 C Climatic suitability In accordance with the standard EN 60068-2-30, EN 60068-2-78 Condensation Not permitted EMC EN 61131-2 Vibration In accordance with the standard EN 60068-2-6 Frequency 10,0-150,0 Hz Max. acceleration 1g Airgap creepage In accordance with the standard EN 61131-2 Overvoltage category II Pollution degree 2 Rated insulation voltage 30 V Shock stress In accordance with the standard EN 60068-2-27 Acceleration 15g Duration 11 ms Max. operating height above sea level <2000 m 15

Technical details Mechanical data 772131 Mounting position Horizontal on top hat rail Protection type In accordance with the standard EN 60529 Mounting (e.g. cabinet) IP54 Housing IP20 Terminals IP 20 DIN rail Top hat rail 35 x 7,5 EN 50022 Recess width 27 mm Max. cable length Max. cable length per input 22,0 m Material Bottom PC Front PC Top PC Cross section of external conductors with screw terminals 1 core flexible 0,25-2,50 mm², 24-12 AWG 2 core with the same cross section, flexible without 0,20-1,50 mm², 24-16 AWG crimp connectors or with TWIN crimp connectors Rigid single-core, flexible multi-core or multi-core 0,5-1,5 mm² with crimp connector Torque setting with screw terminals 0,50 Nm Connection type Spring-loaded terminal, screw terminal Mounting type pluggable Cross section of external conductors with spring-loaded 0,20-2,50 mm², 24-12 AWG terminals: flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection 2 Stripping length 9 mm Dimensions Height 101,4 mm Width 22,5 mm Depth 120,0 mm Weight 85 g The standards current on 2012-04 apply. 16

Order reference 9 Order reference Order reference Product type Features Order no. PNOZ m ES RS232 Expansion module 772 131 Order reference: Terminator, jumper Product type Features Order no. PNOZ mm0.xp connector left Jumper yellow/black to connect the modules, 1 piece 779 260 17

100270 -EN-01, 2013-01 Printed in Germany Pilz GmbH & Co. KG, 2011 12 345-67, 2011-00 Printed in Germany Pilz GmbH & Co. KG, 2011 In many countries we are represented by our subsidiaries and sales partners. Please refer to our homepage for further details or contact our headquarters. Pilz GmbH & Co. KG Felix-Wankel-Straße 2 73760 Ostfildern, Germany Telephone: +49 711 3409-0 Telefax: +49 711 3409-133 E-Mail: pilz.gmbh@pilz.de Internet: www.pilz.com Technical support +49 711 3409-444 support@pilz.com InduraNET p, Pilz, PIT, PMCprotego, PMI, PNOZ, Primo, PSEN, PSS, PVIS, SafetyBUS p, SafetyEYE, SafetyNET p, the spirit of safety are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions.