Advanced Fiber Optic Connector Installation

Similar documents
Fiber Optic and CAT 5-6 Installer Premise Cabling

Fiber Optic Technician - Outside Plant (FOT-OSP) Course Description. Certification(s) Students Will Learn. Splicing Overview & Testing Outside Plant

Training Catalog. The leader in fiber optic training

Course Outline Cover Page

CONNECTOR SOLUTIONS. FASTConnect FUSEConnect Field Master

Hands-On Outside Plant Intro-Level Technician

Panduit Certified Installer. Fiber Certification Review

A wide range of connectors are available to fit very specific needs.

Training Offer. Catalogue

Federal Supply Service Authorized Federal Supply Schedule Price List Contract number:

City & Guilds

White Paper. FASTConnect or FUSEConnect Which Should You Choose? ABSTRACT INTRODUCTION. Tom Jeffers, Associate Product Manager, AFL

UniCam High-Performance Connectors, Multimode and Single-Mode

Basic Fiber Optic Concepts

CommercialNetworking: Training

AF-OLK5A Series Fiber Optic Test kit

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR SIMPLEX OPTICAL FIBER (MULTIMODE) NO-EPOXY, NO-POLISH CONNECTORS

OPTICAL CABLE & CABLE ASSEMBLY

Emerging Fiber Termination Solution

2018 DVD Catalog. Staff Development DVDs. The Leader in Fiber Optic Training

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

Polymer Coated Fiber Cable (PCF)

Testing Optical Feeds in Wireless Systems Remote Radio Units (RRU) and Distributed Antenna Systems (DAS)

LTS-2A LTS-10 LTS-10C LTS-11 LTS-12

FTTH Fusion SOC / MPO / Patch Cord

Product Introduction. G0306A USB 400x Video Inspection Probe

Hands-On Fiber Optic Designer

SCT-MMA / SCT-SMA Fiber Optic Adapters

LEAD Fiber Optics PRODUCT CATALOGUE

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

Fiber Termination Where we ve been and where we re going. Lylette Macdonald, RCDD Legrand Ortronics

Ra Series Fiber Optic Test Instruments

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CONNECTORS, FIBER OPTIC, SINGLE FIBER, SMALL FORM FACTOR, LC TYPE

FEATURED PRODUCTS SC & LC MINI BOOTS LC-HD TOP ADAPTER XP-SERIES LC SWITCHABLE UNIBOOT IP-SERIES LC-KEYED FLEX BOOTS PLC-WDM

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

A COMPARISON OF PRE-POLISHED CONNECTORS VS. FUSION-SPLICED PIGTAILS AS FIELD TERMINABLE SOLUTIONS

FiberBasix 50 Handheld Testers

Fiber in Data Centers What s Next? Srinivasan B, RCDD

3M Fibrlok Optical Splice System

Product Bulletin PB 308

Clean or not clean? itnetworks.softing.com

OPTICAL CONNECTOR CONTAMINATION

Pre-terminated Multi Fibre Cable Assemblies

UniCam Connector Installation Tool Kits

2DXX Optical Modules with Diagnostic Analog Output

Fiber Optic Technology 101. Principles and Advantages. When is fiber the ideal choice For your network? I n s c a p e D a t a C o r p o r a t i o n

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

FTTH Fusion SOC / Patch Cord

Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator

Installation, Testing, Commissioning, Troubleshooting, and Maintenance. Our Consultant: MR. TAN SWEE BENG

Capabilities Statement W. Catawba Ave Cornelius NC (704) Phone (800) Fax

Advances in Fiber Tier 2 Enterprise & Data Center Testing

Clearview Cassette. Clearview Blue

OFI-2000 Multifunction Loss Test Set

Optical Loss Budgets

Optical Fiber Test and Troubleshooting Solutions

SmartPocket Optical Power Meter OLP-34/35/38

Planar Lightwave Circuit (PLC) Splitter, 1x4, 1x8, 1x12 and 1x16 Configurations in PEACOC Flexible Tray

CS260 Contractor Series OTDR

VISIBLE FIBER OPTIC FAULT LOCATOR

White Paper: Choosing the RIght OTDR for your Datacenter

ITT Technical Institute. ET3430 Fiber Optic Communications Onsite Course SYLLABUS

FUSION SPLICERS Splicing Made Easy and Affordable

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

POL-001 Fiber-Optic In-Line Polarizer. Operation Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com. FiberTEK III

LTS-1 LTS-1C LTS-2 LTS-5 LTS-6 LTS-7 LTS-10 LTS-11 LTS-12. Wilcom. Optical Loss Test Kits. Description LTS-2

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types

Autofocus Video Inspection Probe G0382A. Product Introduction

Customer Training Catalog Training Programs Outside Plant

Optical Components: Not to be Taken for Granted. By Matt Brigham, Product Manager

Fiber Optic Connectors and Cables. Rugged High-Bandwidth Mil-Aero Grade

Fiber Design for Traffic Signals and ITS Projects

White Paper: Testing Strategies for SYSTIMAX High Speed Migration Solutions

LEAVE THE TECH TO US

DTX-MFM/GFM/SFM. Fluke Networks DTX-GFM Specs. Users Manual. Provided by Fiber Modules

SUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade

Adrian Young Leviton Network Solutions

LEAD Fiber Optics PRODUCT CATALOGUE

Multimode Measurement Cords Recommendations for Multimode Link Field Certification

Test Port Adapters Reference Guide

SECTION COMMUNICATIONS BACKBONE CABLING

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

Fiber Management Systems

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing

Indoor Cable Application Note

MT9085 Series. ACCESS Master. Quick User s Guide

FO Field Genuine alternative to splicing

Fiber Optics Technician's Manual By Jim Hayes

PATCH-CORD. SC Patch-Cord APPLICATIONS AVAILABILITY FEATURES SPECIFICATIONS. Active device termination Local Area Networks (LANs)

ONMS. Optical Network Management System

High Precision Fusion Splicer

Fiber Optical Cabling Infrastructure Offer

FiberSolutions. Fiber Optic Cable & Assembly Solutions

City & Guild (102/103) Learn to Install & Test Fibre Optic Cable. Introductory Guide. Centre. Training Academy

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

T-BERD /MTS-4000 Platform Multiple Services Test Platform

ARIADROP: Fiber to the MDU (FTTM)

PARKING. JDSU Solutions for Enterprise Structured Cabling

Transcription:

Advanced Fiber Optic Connector Installation QUICK SUMMARY Length: 48 hours, 52 hours with Fiber Optic Association CFOT certification Hands-on Activities: activities, 70-75 % Text/Field Reference: Professional Fiber Optic Installation-v10, 494 pages, ( 2017) Additional Texts: PowerPoint Slides For Professional Fiber Optic Installation, v9 and Certification And Troubleshooting Fiber Optic Networks History: continuous evolution since 1995 Developer and Presenter: Eric R. Pearson, CFOS/T/C/S/I Benefits: reduced power loss, reduced installation cost, increased network reliability, certification, confidence Who Should Attend: installers, installation supervisors, installation planners, network technicians, network designers Additional Information: contact us BENEFITS By attending Advanced Fiber Connector Installation, a five-day, hands on installation training program, you are able to install fiber optic cables, connectors, splices and achieve the three goals of installation. In addition, you develop advanced connector installation skills, so that you achieve consistent results when you start your fieldwork. These three goals, minimum power loss, maximum reliability, and minimum cost, require knowledge of the specific procedures and compliance with the unique rules of fiber optic communication products. You learn this knowledge and these rules from the lectures and hands on activities of this comprehensive and well-developed program. In addition to learning basic skills for most of the procedures, this program takes you up the connector installation learning curve, so you achieve consistent low loss and low cost during connector installation. DESCRIPTION Through the combination of lectures and hands on activities, you learn how to perform all the steps required from the time you receive the products to the time at which you certify the network as being properly and reliably installed. These steps include: Pearson Technologies Inc. 1

Installation of cables without damage End preparation of both loose and tight tube cables Installation of low loss, reliable multimode and singlemode connectors Inspection of connectors to determine installation quality Installation of low loss fusion and mechanical splices Proper testing of insertion loss, OTDR and reflectance Calculation of acceptance values for all tests, and Certification and troubleshooting of installed links for maximum reliability. During connector installation training, you install 24 connectors under the supervision of a highly experienced instructor. By inspecting each connector after installation, you gain feedback on the quality of your installation procedure. This nearly- immediate feedback enables you to identify proper installation methods and learn to avoid high power loss and high installation cost. By testing the power loss after each pair of connectors, you learn the impact of your installation method. This nearly-immediate feedback enables you to develop consistent installation procedures for two different installation methods. EXTENSIVE HANDS-ON ACTIVITIES Advanced Fiber Connector Installation includes 40 hands-on training activities for all of these necessary steps. These hands-on activities consume approximately 70-75% of the program. Mr. Eric R. Pearson developed and delivers this program. Mr. Pearson, CFOS, is a 39- year veteran of fiber optic communications, a former Director of the FOA, a BICSI Master Instructor, a Certified Professional Consultant, a FOA Master Instructor, and a widely recognized expert in fiber optics and in installation procedures. Whether you are a data network or SAN installer, military data specialist, network technician, PON technician, installation supervisor, network supervisor, security system installer, or CATV installer, this program will return many times your investment! This program is based on the comprehensive, 494-page, up-to-date text, Professional Fiber Optic Installation-v10 ( 2017). This text is a valuable and useful field reference and resource. Be successful like the more than 7900 people who have taken installation-training programs from Pearson Technologies! DAY 1 1. OVERVIEW OF NETWORKS Topologies Pearson Technologies Inc. 2

Link And Components 2. THE LANGUAGE OF LIGHT Three Descriptions Of Behavior Seven Properties Wavelength Spectral Width Index of Refraction Power Reflection Numerical Aperture Refraction Dispersion 3. FIBER Three Structural Regions And Functions Three Types Two Performance Specifications Dispersion Attenuation Determine Fiber Handling Rule For Tension Determine Fiber Handling Rule For Bending Determine Fiber Preparation Rule Determine Fiber Insertion Rule Practice Fiber Strength Check 4. CABLE Structure Types Installation Specifications Environmental Specifications Prepare Loose Tube Cable End Prepare Tight Tube Cable End The Continuity Test 5. CABLE INSTALLATION RULES Environmental Limits Installation Limits Cable Placement Planning And Management Issues Safety Issues Pearson Technologies Inc. 3

End Preparation Review Questions [for FOA certification programs] DAY 2 6. CONNECTORS Function Structures Specifications Features Types Installation Methods 7. PRINCIPLES OF CONNECTOR INSTALLATION Adhesive Use Crimping Polishing Cleaning Cleaving Install 12 polish type connectors [SC is standard. FC and ST -compatible are options] Install 12 Unicam Connectors; [SC is standard. LC, SC, and ST compatible are options] Option: install 12 pigtail connectors; type to be determined DAY 3 The Continuity Test 8. CONNECTOR INSPECTION Inspection Criteria Core Cladding Ferrule Surface Hands On Activity Inspect And Rate Connectors Use Visual Fault Finder With No Polish Connectors 9. SPLICES Locations Type Options Structure Pearson Technologies Inc. 4

DAY 4 Specifications Hands On Activity Fusion Splicing- midspan Fusion Splicing- ribbon[optional] Mechanical Splicing- midspan Measure Loss- midspan fusion splice Measure Loss- midspan mechanical splice Review Questions [for FOA certification programs] 10. TESTING PRINCIPLES General Principles TIA/EIA-568 B Requirements Insertion Loss Testing Method B Test Test Directional Effects Test Repeatability And Range Correlate Microscopic Appearance With Loss Troubleshoot Testing Problems Optical Time Domain Reflectometry Theory Three Typical Traces Measurement Methods Length Connection Loss Attenuation Rate Identify Measurements Identify Features Reflectance 11. OPTOELECTRONICS Design Concerns Light Sources And Detectors Specification Options Optical Power Budget (Available) Minimum Required Loss Wavelength Spectral Width Connector Type Pearson Technologies Inc. 5

DAY 5 12. NETWORK CERTIFICATION FOR MAXIMUM RELIABILITY Certification With Maximum Loss Values Advantage Disadvantage Develop Certification Strategy For Maximum Reliability Acceptance Values for 850 nm Premises Riser Network Calculate Acceptance Values For 850 nm Premises Riser Network Calculate Acceptance Values For 1310 nm OSP Network 13. NETWORK CERTIFICATION AND TROUBLESHOOTING Calculate Acceptance Values Insertion Loss OTDR Perform Insertion Loss Test Perform OTDR Tests Length Connector Loss Attenuation Rate Uniformity of Segment Determine Location of Defective Installation Recognize Proper Cursor Placement Interpret OTDR Traces Write Certification Summary Review Questions [for FOA certification programs] 26 November 2017 Pearson Technologies Inc. 6

Pearson Technologies Inc. 7