T4 Signal Model No: T4.034.23.US Date: Fixture Type: Project: Specifier/ep: Certified by C ompliance LM7908 and LM8008 Available for International specifications by adding 'T' at the end of the existing Model # International spec sheets are available upon request Exact Measurements: Metric Model: Installation: Housing: Light Color: Fixture Finish: Fixture Material: Lamp Type: Number of s: Total Wattage: Lamp Voltage: Lamp Life: T4.034.23.US ecessed mount fixture for Wall, Driveover for Inground Floor and Furniture(recessed and display) 204cm / 80 11/16" CAS.0156.99 or CAS.0162.99 equired Transparent,Aluminum High esistant PMMANatural Anodized Aluminum Signal 200 30W 50,000 hrs at 70% of lamp lumen output with IES LM80. For optimized perfomance follow instruction sheet. Pitch: 2 IP ating: IP68 Width: 4cm / 1 9/16" Length: 202cm / 79 1/2" Height: 4cm / 1 9/16" Weight: 2600g/m / 40.2oz/ft Additional Details ecessed Driveover professional lighting system for indoor, outdoor and underwater application; DMX or DALI dimmable. equires Housing ox to be ordered separately. reaking Strength: Power Supply: Control ear: IK10 Constant voltage supply dimmable, parallel connection (Not Included) Sold separately (see components) 30 Tycos Dr. Toronto, ON Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com, tech@zaneen.com Page 1 of 2
T4 Signal Model No: T4.034.23.US Date: Fixture Type: Project: Specifier/ep: Load esistance: 5000kg / 11020lbs oll over Lumen Chart Photometric File Power Color Temperature Nominal Lumen Actual Lumen T4.034.XX 30W 798 239 T4.034.XX 30W (osso) 237 81 T4.034.XX 30W (Verde) 468 166 T4.034.XX 30W (lu) 93 23 Accessories T4 Fixing Kit Transparent [KIT.0125.99] Fixing Kit to mount T4 1 Piece Transparent T4 End Cap [KIT.0135.99] End Cap for housing box (1 couple) Waterproof Connection ox IP68 30mm [MEL.0137.99] 30mm / 1 3/4" x 95mm / 3 3/4" x 24mm / 1" 4 Channel Waterproof Connection ox cable max Ø 6,2mm Waterproof Connection ox IP68 30mm [MEL.0061.99] 30mm / 1 3/16" x 31mm / 1 2/9" x 30mm / 1 3/16" 2 Channel Waterproof Connection ox Waterproof Connection ox IP68 45mm [MEL.0096.99] 45mm / 1 3/4" x 95mm / 3 3/4" x 24mm / 1" 4 Channel Waterproof Connection ox Max Cable Ø9.5 12mm System Components T4 204cm Housing ox Type A [CAS.0156.99] 204cm / 80 11/16" Housing ox for T4 Type A T4 204cm Housing ox Type [CAS.0162.99] 204cm / 80 11/16" Housing ox for T4 Type DMX /010V Control ear 3 Channels [ECO.0038.99] Constant Voltage Dimmable Dali/PWM Interface Control ear 3 Channels [ECO.0049.99] DMX Splitter 1 input / 3 Output channels [ECO.0020.99] US DMX / DM Interface [ECO.0041.99] Power Supply constant voltage 10W [ALI.0059.99] Main Voltage Constant 120 240V 10W 50/60Hz Power Supply constant voltage 25W [ALI.0060.99] Main Voltage Constant 120 240V 25W 50/60Hz Power Supply constant voltage 20W [ALI.0103.99] Main Voltage Constant 90 264V 20W 50/60Hz Available Sizes and / or Lamping T4 Signal [T4.031.23.US] 52cm / 20 1/2" 50 Signal, 8W Pitch 2 T4 Signal [T4.032.23.US] 102cm / 40 3/16" 100 Signal, 15W Pitch 2 T4 Signal [T4.033.23.US] 152cm / 59 13/16" 150 Signal, 23W Pitch 2 T4 Signal [T4.034.23.US] 202cm / 79 1/2" 200 Signal, 30W Pitch 2 30 Tycos Dr. Toronto, ON Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com, tech@zaneen.com Page 2 of 2
Wiring diagrams and electrical connections The new lighting systems, that use light sources in a solid state must be connected to the main voltage through electronic devices that maintain the critical parameters of operation constant. With Leds in particular, the current values that pass through the light source must remain constant and if necessary measurements are not taken to keep these parameters constant, the will tend to absorb higher currents resulting overheating triggering a vicious mortal cycle of the semiconductor. ecause of this physicalelectric phenomenon the systems with technology need very sophisticated control devices compared to the traditional sources. The current control can be integrated into the power supply or can be placed between the power supply and the system. In this case the Led connection should be done in series with a maximum quantity of 10/12 Led that can be connected In the most evolved systems the control electronic can be split and integrated directly on the PC together with the Leds; here the connection can be done in parallel with a 24V dc power supply and without any limit of the quantity of Leds that can be connected To facilitate the user in consulting this catalog, in this section there is a list of all the diagrams of connection between control gears, interfaces and power supplies, as well as the combination of the correct power supplies / control gear and lighting systems showing the article codes. Important note: Suggested maximum distance from driver: 30ft (using 18 AW solid copper wire) Disclaimer: Distances, type of wiring and gauge must be determined by a certified professional to avoid voltage drop problem. Maximum 9m (30 ft) Serial connection Maximum 9m (30 ft) Parallel connection 30 Tycos Drive, Toronto, Ontario, Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319, www.zaneen.com tech@zaneen.com
P DMX/DALI Parallel connection for dimmable systems DALI converter US / DMX interface ECO.0038.99 ECO.0047.99 DMX control gear codes ALI.0076.99 ALI.0074.99 ALI.0072.99 US DALI converter US / DALI converter ECO.0049.99 US DMX / DALI Controller 30 Tycos Drive, Toronto, Ontario, Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319, www.zaneen.com tech@zaneen.com
V Parallel connection for MOVE systems codes ALI.0059.99 ALI.0060.99 ALI.0061.99 ALI.0103.99 DMX DMX Controller DMX DMX DMX DMX DMX Control gear ECO.0054.99 30 Tycos Drive, Toronto, Ontario, Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319, www.zaneen.com tech@zaneen.com
W DMX Splitter connection DMX control gear codes DMX A DMX Control gear DMX DMX Splitter 1 2 3 ECO.0054.99 DMX splitter ECO.0020.99 ALI.0059.99 ALI.0060.99 ALI.0061.99 ALI.0103.99 DMX interface DMX DMX DMX DMX DMX DMX ECO.0038.99 ECO.0047.99 * 30 Tycos Drive, Toronto, Ontario, Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319, www.zaneen.com tech@zaneen.com
Y DMX Parallel connection for W dimmable systems DMX interface codes W US / ECO.0056.99 ALI.0059.99 ALI.0060.99 ALI.0061.99 ALI.0103.99 DMX control gear W W W ECO.0054.99 W US / W W W US DMX Controller 30 Tycos Drive, Toronto, Ontario, Canada M6 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319, www.zaneen.com tech@zaneen.com