MORPHEE 2, EtherCAT and Fast ECU Access. D2T s automation system : A fast and reliable communication with test bed

Similar documents
EtherCAT with MORPHEE 2, D2T s Automation System A fast and reliable communication with the test bed

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Q Series - Q.station 101 Test Controller

VT System Smart HIL Testing

imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing

rcube2: Advanced Rapid Prototyping Electronic Control Unit

Q.brixx station 101. Base Unit with Test Controller. Most important features:

imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing

Hardware Robot Operating System. D-module STUDY CASE

5. Current Sharing in Power Arrays

EtherCAT Introduction

ET3206A. ET3206A Datasheet_V2.3

DIGITAL CONTROL/COMMAND DEDICATED TO CONVERTERS GLOBAL OVERVIEW

BX8 8-Channel Digital Amplifier

Model-based Calibration of HD Engines. Benjamin Tilch, Rico Möllmann, Axel Steinmann, Dr. Reza Rezaei GT-SUITE Conference, Frankfurt, October 2014

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

Application Story EtherCAT Master Controller in Factory Automation

EtherCAT P combines ultra-fast communication and power supply in a single cable

Introduction to Computer Networks INTRODUCTION TO COMPUTER NETWORKS

Design Verification and Calibration Based on Physical Measurements for Electrical Vehicles

ECU Measurement and Calibration in a Real-Time Test Environment. Roland Magolei National Instruments Engineering GmbH Embedded Networks

AMS 5812 OEM pressure sensor with an analog and digital output

imc BUSDAQ / imc BUSLOG

EtherCAT or Ethernet for Motion Control


Systems. Roland Kammerer. 10. November Institute of Computer Engineering Vienna University of Technology. Communication Protocols for Embedded

Hexapod Motion Controller with EtherCAT

Virtualizing the TCU of BMW's 8 speed transmission

Industrial Networks & the Impact of Traffic

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile

C x Hexapod Motion Controller

ES Knock Intensity Detection Board. KID_SU KID Signal Unit User Manual

Oct Karl. A. Meier

ISO INTERNATIONAL STANDARD. Road vehicles FlexRay communications system Part 4: Electrical physical layer specification

Product Information ES582.1 Compact USB Device

imc fieldbus conection options Table of contents 1. imc fieldbus connection options 2. Fieldbus: Technical Details

Interfacing Techniques in Embedded Systems

Automotive and industrial use cases for CAN FD

Techniques to Reduce Measurement Errors in Challenging Environments

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

Explorer V1.20. Features

Copyright, Data Science Automation, Inc. All Rights Reserved. Page 1 of 5

Since two ports are executed on the additional board for the MODBUS-TCP, the following network topologies can be implemented: Bild 1: Topology

Multi-Axis Position Control by EtherCAT Real-time Networking

Kyland solution for IEEE1588 Precision Time Synchronization in Electric Utilities

SERIES SIX PROGRAMMABLE CONTROLLERS AXIS POSITIONING MODULE (TYPE 1) GEK-83543A GENERAL DESCRIPTION

Open, Scalable Real-Time Solutions

FlexRay International Workshop. Protocol Overview

Class 6 Industrial Ethernet

The Mobile Combustion Analyzer from Kistler. KiBox T o Go -Präsentation hoe March 09 1

Platinum Maestro Multi Axis Control. The Ultimate Machine Motion Controller

Data sheet VIPA CPU 115DP (115-6BL22)

Christian Brothers High School, Lewisham. Year 12 Information Processes & Technology. Assessment Task 3: Communications Systems.

Motion Controller. MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control

The Wizarding World of Automation

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Combining EtherCAT with Power

Scalable and Flexible Software Platforms for High-Performance ECUs. Christoph Dietachmayr Sr. Engineering Manager, Elektrobit November 8, 2018

Chapter 16: Switched Ethernet in Automation. Wenbo Qiao

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Platinum Maestro Multi Axis Control. The Ultimate Machine Motion Controller

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system

Welcome. Introduction and startup JUMO dtrans ph02. Dipl.-Ing. Manfred Schleicher

the easy solution for Smart Metering

Class 6 Industrial Ethernet

Embedded Controller combines Machine Control and Data Acquisition using EPICS and MDSplus P. Milne

Parallel connection / operations and current share application note

TFS 2100 Traveling Wave Fault Location System

Designing Real-Time Control Applications Using LabVIEW and CompactRIO. Developer Days 2009

ADI Solution for Industrial Communications

DS2020SingleAxis ExtremelyCompact ServoDrives

CSE 123: Computer Networks Alex C. Snoeren. HW 2 due Thursday 10/21!

DRAFT. Dual Time Scale in Factory & Energy Automation. White Paper about Industrial Time Synchronization. (IEEE 802.

Figure 3.174: Illustration of the code of the event f USB that plots an USB camera frame if the typed frame is under the acceptable limits (case 0)

Overview. Rev. 1.5c. November 17, 2003

Analysis of Switched Ethernet Networks with different Topologies used in Automation Systems

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

TM258LD42DT4L compact base M I/O - 24 V DC

How to add Industrial Ethernet to Computer Numeric Control (CNC) Router Machine

Advanced NI-DAQmx Programming Techniques with LabVIEW

Elchin Mammadov. Overview of Communication Systems

CONTENTS INTRODUCTION. System overview...2. Axis module...3 Interface...3 Technical characteristics and environmental data...4 Dimensions...

L-force 9400 StateLine Servo Drives

Interface for 8 inductive probes Tesa halfbridge, Knäbel IET, Solartron LVDT or Feinprüf / Mahr. Others on request.

IEEE 1588 PTP clock synchronization over a WAN backbone

Ultra-Accurate Measurement for Temperature and Voltage

Overview. Complete Application-Ready Platforms for General Motion Control Tasks. AMONet - Advantech Distributed Motion Control Solutions 14-2

The System for Power Automation

TM258LD42DT4L compact base M I/O - 24 V DC

Development of remote monitoring and control equipment with advanced communication functions

BCM48 Body Control Module w/ Ethernet, 4 CAN, 4LIN channels P/N: BCM

What s New in Data Acquisition

Basics of UART Communication

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual

ADVANCED SCADA CONTROL SYSTEMS

ASAM MCD-1 (XCP) Protocol Layer Specification Base Standard

Transcription:

MORPHEE 2, EtherCAT and Fast ECU Access D2T s automation system : A fast and reliable communication with test bed 1

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 2

MORPHEE 2 overview MORPHEE 2 is a unique system for test bed automation, engine calibration tests implementation & model integration into the test bed (simulation). A real time system working with the real time RTX kernel which guarantees full compatibility with future OS and Hardware 3

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 4

EtherCAT overview EtherCAT (Ethernet for Control Automation Technology) An open high performance Ethernet-based field bus system. EtherCAT goals Ethernet for automation short data update times (also called cycle times) low communication jitter (for synchronization purposes) low hardware costs. 5

EtherCAT overview EtherCAT implements a master/slave architecture over standard Ethernet cabling. EtherCAT provides wiring redundancy (ring LAN) Master EtherCAT MORPHEE 2 EtherCAT Wiring redundancy Slave EtherCAT Slave EtherCAT Slave EtherCAT 6

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 7

EtherCAT advantages High speed Very good transfer rates, bandwidth and transfer speed. Real-time capability Clock rates greater than 10 khz. Flexible topology Line network Tree network Star network Redundancy Wiring fault management 8

EtherCAT advantages Reduced wiring costs Uses standard Ethernet cable. Longer distances via digital signal transfer Shorter analogue signal paths. Reduced hardware costs Uses standard Ethernet board for the EtherCAT Master. 9

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 10

EtherCAT in MORPHEE 2 D2T EtherCAT solution is based on: MORPHEE 2 automation system KOENING RTX master (EtherCAT master real-time) KOENING Studio (Configuration) EtherCAT Driver for MORPHEE 2 11

EtherCAT in MORPHEE 2 Test bed architecture: 12

EtherCAT in MORPHEE 2 MORPHEE 2 integration: 13

EtherCAT in MORPHEE 2 Adding a slave EtherCAT in MORPHEE 2 is very easy. Sample rate up to 10khz 14

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 15

Data Acquisition with EtherCAT Automation system MORPHEE 2 A wide EtherCAT device range for multi application (Data acquisition, fast ECU access, drive, actuators, measuring devices ) True real time fast acquisition (no buffering) 16

Data Acquisition with EtherCAT A wide range of device Acquisition for physical measurements: Voltage Current Resistance Temperature TC PT100,PT1000 Digital I/O Bridge, LVDT Frequency, PWM 17

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 18

Fast ECU access With increasing complexity of engines, calibration effort is increasing which is reflected in the number of calibration labels in an ECU. The goals of the new calibration methods are Performance increase to reduce calibration times Moving from steady state experiments to transient calibration Better reproducibility of test runs 19

Fast ECU access A common architecture used today Communication to ECU is done through INCA (MCD3) Configuration is done by INCA (MCD3) Cycle time 100 ms 20

Fast ECU access A new architecture with Fast ECU access Communication to ECU is done through a direct EtherCAT link Configuration done by INCA (MCD3 - COM) Cycle time <1 ms 21

Fast ECU access A common architecture used today A new architecture with Fast ECU access 22

Fast ECU access The rapid calibration access enables us to increase the number of intermediate calibration steps, thus reducing the required set time The increased number of intermediate calibration steps leads to a faster stabilization time The overall calibration task can be reduced by ~30% 23

Contents MORPHEE 2 Overview EtherCAT Overview EtherCAT Advantages EtherCAT in MORPHEE 2 Data Acquisition with EtherCAT Fast ECU access with EtherCAT and ETAS Road map 24

Road Map OSIRIS control and data exchange over EtherCAT A common architecture used today Fast access solution Increase data transfer speed between MORPHEE 2 and OSIRIS (Combustion Analysis) 25

Road Map DCU 3000: Dynamometer torque and speed servo-controlling 2 khz fast PID controllers Measurement filtering algorithms dedicated to engine applications 26

Powertrain Engineering Thank you for your attention You are welcome on our stand for a demonstration..