CJ1W-EIP21. CJ-series EtherNet/IP Unit. Introducing the New EtherNet/IP Unit. More Than 180,000 Words of Tag Data Link Capacity!

Similar documents
CJ1W-EIP21 CSM_CJ1W-EIP21_DS_E_9_2

CS1W-EIP21 CSM_CS1W-EIP21_DS_E_7_3

CJ1W-FLN22. CJ-series FL-net Unit. Connect to Multivendor Controller Networks. Features

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

CJ1W-ETN21 CSM_CJ1W-ETN21_DS_E_6_2

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

CJ1W-FLN22 CSM_CJ1W-FLN22_DS_E_3_1

NJ-Series Power Supply Unit NJ-PA/PD

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

EtherNet/IP Monitor Tool Operation Manual

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

SYSMAC CJ-series CJ1M CPU Units (with Ethernet function)

EtherCAT master * Output port CPU Unit

CJ1W-SPU01-V2. CJ-series High-speed Data Storage Unit (SPU Unit) High-speed Collection of System Data. Features. System Configuration

Analog Input Unit. MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

CX-One Ver.4 CSM_CX-One_DS_E_8_2

NPN output. 200 mm. Type Cable length Model Remarks

CX-One Ver.4 CSM_CX-One_DS_E_10_2

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

SYSMAC CJ-series CJ2H (Built-in EtherNet/IP) CPU Units. Flagship PLCs with Built-in Multifunctional Ethernet Port.

Model Number Structure

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

SYSMAC CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

SYSMAC CJ-series CJ2H (Built-in EtherNet/IP) CPU Units. Flagship PLCs with Built-in Multifunctional Ethernet Port.

Photoelectric Sensor

Limit Switch Connectors

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Machine Automation Controller NJ-series. EtherNet/IP TM. Connection Guide. OMRON Corporation. CJ2-series Controller P568-E1-01

SYSMAC CS-series MECHATROLINK-II-compatible Position Control Units

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

Handheld Reader Writer

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

The Global Standard Network controls and information.

Limit Switch Connectors

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

CJ1W-SPU01-V2. CJ-series High-speed Data Storage Unit (SPU Unit) High-speed Collection of System Data. Features. System Configuration

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Model Number Structure

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Model Number Structure

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Intelligent Flag Amplifier

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

CJ Series EtherNet/IP TM Connection Guide. OMRON Corporation NX-series EtherNet/IP Coupler Unit P656-E1-01

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Model NPN output PNP output Standard. configuration

Features various encoder interfaces and controls multiple analog servo drives at high speeds

NX-TS. NX-series Temperature Input Unit

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

SYSMAC CJ-series CJ2M CPU Units

SYSMAC CJ-series CJ2H CPU Units. Setting new standards in high-speed machine control. Features

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

SYSMAC CJ-series CJ2H (Built-in EtherNet/IP) CPU Units

CJ Series EtherNet/IP TM Connection Guide. ABB Ltd. IRC5 Robot Controller P572-E1-01

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

CJ Series IO-Link Connection Guide (EtherNet/IP TM Host Communications) OMRON Corporation Proximity Sensor (E2E-series IO-Link)

MARS TOHKEN SOLUTION CO.LTD. Fixed Mount 1D/2D Image Reader (TFIR-31LAN Series)

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

SYSMAC CJ-series Position Control Units with EtherCAT interface

CPU Unit. (Temperature control) (Position control) (Speed control)

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Peripheral Devices for Environment-resistive Slaves

CSM_CJ1G-CPU4_P_DS_E_5_2

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

CJ Series EtherNet/IP TM Connection Guide. OMRON Corporation RFID Reader/Writer (V680S-series) P626-E1-01

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

E2K-X4ME1 2M E2K-X4ME2 2M

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

CJ Series EtherNet/IP TM Connection Guide. SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01

CPU Unit Motion Control

Model Number Structure

CJ Series EtherNet/IP TM Connection Guide. Yamaha Motor Co., Ltd. Robot Controller (RCX340) P624-E1-01

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

Transcription:

CJ-series EtherNet/IP Unit CSM DS_E_7_1 Introducing the New EtherNet/IP Unit. More Than 180,000 Words of Tag Data Link Capacity! EtherNet/IP is an industrial multivendor network that uses Ethernet. Managed by the ODVA (Open DeviceNet Vendors Association), it has open standards and is used with a wide range of industrial devices. The EtherNet/IP Unit supports tag data links to enable sharing data between devices at Ethernet nodes and a message service for sending and receiving data when required. The EtherNet/IP Unit supports the same FINS/UDP and FINS/TCP functionality as Ethernet Units. Features Large-capacity tag data links are easily enabled by simply setting connections, with no programming required. Tag data links can be used to exchange data with up to 256 nodes over up to 256 connections. Up to 256 connections can be set per Unit with up to 722 words of data per connection, for a total of up to 184,832 words of link data. (There is no limit to the data link capacity for the overall network.) Data concurrency is maintained within each connection (for up to 722 words). Tag data link settings can be changed for individual Units even while tag data links are being used on a network. Errors can be diagnosed using the Network Configurator, and system errors can be monitored with a wide array of status flags. System Configuration Network Configurator Switching hub Twisted-pair cable Ethernet (LAN) port 100 m max. CS1W-EIP21 EtherNet/IP Unit for CS-series EtherNet/IP Unit EtherNet/IP Unit CS-series PLC CJ-series PLC NJ-series Machine Automation Controller * Built-in EtherNet/IP port on CJ2 CPU Unit (CJ2H-CPU6@-EIP/ CJ2M-CPU3@) * EtherNet/IP Unit with unit version 2.1 or later is required to connect C1JW-EIP21 to NJ-series CPU Unit. Use CPU Unit with version 1.01 or later and Sysmac Studio with version 1.02 or later. 1

Ordering Information International Standards The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: culus, UC1: culus (Class I Division 2 Products for Hazardous Locations), CU: cul, N: NK, L: Lloyd, and CE: EC Directives. Contact your OMRON representative for further details and applicable conditions for these standards. EtherNet/IP Unit Unit type Product name Communications cable Specifications Communications functions Units per CPU Unit No. of unit numbers allocated Current consumption (A) 5 V system 24 V system Model Standards EtherNet/IP Unit CJ1 CPU Bus Unit Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e Tag Data Link Functions, Message Communications Functions 8 max. *1 1 0.41 *2 UC1, N, L, CE *1. Up to four EtherNet/IP Units can be connected to a NJ CPU Unit. Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU6@-EIP. Up to two EtherNet/IP Units can be connected to a CJ2M CPU Unit. *2. EtherNet/IP Unit with unit version 2.1 or later is required to connect C1JW-EIP21 to NJ-series CPU Unit. Use CPU Unit with version 1.01 or later and Sysmac Studio with version 1.02 or later. Industrial Switching Hubs Product name Appearance Functions Specifications No. of ports Failure detection Accessories Current consumption (A) Model Standards Industrial Switching Hubs Quality of Service (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm and LSI error detection 10/100BASE-TX, Auto-Negotiation 3 No Power supply connector 0.22 W4S1-03B 5 No 0.22 W4S1-05B 5 Yes Power supply connector Connector for informing error 0.22 W4S1-05C CE UC, CE Recommended Network Devices The following table shows the devices recommended for use with the EtherNet/IP. Part Manufacturer Model number Inquires Phoenix Contact FL SWITCH SFN 8TX (8 ports) Phoenix Contact USA Customer Service Switching Hub Contec USA, Inc. SH8008(FIT)H (8 ports) CONTEC USA Inc. Cisco Systems, Inc. WS-C2955T-12 (12 ports) Cisco Systems, Inc. Main Corporate HQ Twisted-pair cable 100BASE-TX Fujikura F-LINK-E 0.5mm 4P Fujikura America, Inc. EtherNet/IP compliant cable Connectors (Modular plug) STP Plug Panduit Corporation MPS588 Panduit Corporation US Headquarters Boots Tsuko Company MK boot (IV) LB Tsuko Company Japan Headquarters Note: 1. Always use a switching hub when using tag data links in the network. 2. If a repeater hub is used for EtherNet/IP tag data links (cyclic communications), the network's communications load will increase, data collisions will occur frequently, and stable communications will be impossible. Mountable Racks Model Unit version 2.0 NJ system CJ1 system CP1H system NSJ system Expansion CPU Rack Rack 4 Units (per CPU Unit) *1 Expansion CPU Rack Backplane 8 Units (per CPU Unit) *2 CP1H PLC NSJ Controller Expansion Backplane *1. EtherNet/IP Unit with unit version 2.1 or later is required to connect C1JW-EIP21 to NJ-series CPU Unit. Use CPU Unit with version 1.01 or later and Sysmac Studio with version 1.02 or later. *2. Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU6@-EIP. Up to two EtherNet/IP Units can be connected to a CJ2M CPU Unit. *3. A CP1W-EXT01 CJ Unit Adaptor is required. 2 Units *3 Not supported 8 Units Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 2

EtherNet/IP Units Specifications Model number Item Type 100Base-TX *1 Applicable PLCs Unit classification Mounting location Number of Units that can be mounted CPU Unit words used Allocated CIO Area words (CPU Bus Unit words) Allocated DM Area words (CPU Bus Unit words) User-set area CPU Bus Unit System Setup Non-volatile memory within EtherNet/IP Unit (See note.) Transfer specifications Media access method Modulation method Transmission paths Baud rate Transmission media Specifications NJ-series, CJ (CJ1, CJ2) series, CP1H, and NSJ series PLCs. CJ-series CPU Bus Unit CPU Rack or Expansion Rack NJ-series System : 4 max. (including Expansion Racks) CJ series System and NSJ series System: 8 max. (including Expansion Racks) *2 CP1H System: 2 max. 25 words/unit (one unit number s words) These words contain control bits and flags, the target node PLC s operating and error information, Unit status, communications status, registered/normal target node information, and FINS/TCP connection status. 100 words/unit (one unit number s words) These words contain the IP address display/setting area. Any usable data area words Target node PLC s operating and error information, and registered/normal target node information Not used. The following settings are stored in the EtherNet/IP Unit s non-volatile memory. Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU Unit is not used for these settings. 1. Unit Setup (communications settings for the EtherNet/IP Unit, such as the IP address, DNS server settings, host name, baud rate, FINS/UDP settings, and FINS/TCP settings) 2. Tag data link settings (device parameters) CSMA/CD Baseband Star form 100 Mbit/s (100Base-TX) Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e 100 m (distance between hub and node) Transmission distance Number of cascade connections There is no limitation when a switching hub is used. Current consumption (Unit) 410 ma max. at 5 V DC Weight 94 g max. Dimensions 31 90 65 mm (W H D) Other general specifications Other specifications conform to the general specifications of the CJ-series. *1. If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended. *2. Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU6@-EIP. Up to two EtherNet/IP Units can be connected to a CJ2M CPU Unit. 3

Communications Specifications CIP service Item Tag data links (Cyclic communications) Number of connections Packet interval (refresh cycle) 256 Specifications NJ CJ2 CJ1 0.5 to 10,000 ms (in 0.5-ms units) Can be set independently for each connection. (Data is refreshed over the network at the preset interval and does not depend on the number of nodes.) Allowed communications 6000pps *1 bandwidth per Unit Number of tag sets 256 Tag types CIO Area, DM Area, EM Area, Holding Area, Work Area, and network symbols *2 Number of tags per connection 8 (7 tags when the tag set contains the controller status) (= 1 tag set) Maximum link data 184,832 words size per node Maximum data size 504 bytes (252 words) or 1444 bytes (722 words) *2 per connection *3 Data synchronicity is maintained within each connection. Number of 256 (1 connection = 1 tag set) registrable tag sets Maximum size 722 words of 1 tag set (The controller status uses 1 word when the tag set contains the PLC status.) Maximum number of tags that can be refreshed per CPU Unit cycle *4 Data that can be refreshed per CPU Unit cycle *4 Output/Transmission (CPU to EtherNet/IP): 256 Input/Reception (EtherNet/IP to CPU): 256 Output/Transmission (CPU to EtherNet/IP): 6,432 words Input/Reception (EtherNet/IP to CPU): 6,432 words Changing tag data link parameters Supported *6 during operation Multicast packet filter function *7 Supported Class 3 (connected) Number of connections: 128 Explicit messaging *8 UCMM (unconnected) Number of clients that can communicate at one time: 32 max. Number of servers that can communicate at one time: 32 max. CIP routing *9 Supported, CS1W-EIP21, NJ-501-@@@@, NJ-301-@@@@, CJ2H-CPU@@-EIP, CJ2M-CPU3@ FINS service FINS/UDP Not supported Supported FINS/TCP Not supported 16 connections max. EtherNet/IP conformance test Conforms to A8 Ethernet interface 10BASE-T or 100BASE-TX Auto Negotiation or fixed settings Output/Transmission (CPU to EtherNet/IP): 19 Input/Reception (EtherNet/IP to CPU): 20 *5 Output/Transmission (CPU to EtherNet/IP): 7,405 words Input/Reception (EtherNet/IP to CPU): 7,405 words *1. In this case, pps means "packets per second" and indicates the number of packets that can be processed in one second. *2. Network symbols can be used only by the NJ501-@@@@, NJ301-@@@@, CJ2H-CPU6@-EIP and CJ2M-CPU3@. *3. To use 505 to 1,444 bytes as the data size, the system must support the Large Forward Open standard (an optional CIP specification). The CS/CJ-series Units support this standard, but before connecting to nodes of other companies, confirm that those devices also support it. *4. If the maximum data size is exceeded, the data refreshing with the CPU Unit will extend over two or more cycles. *5. If status layout is selected in the user settings, the maximum number of tags that can be received is 19 tags. *6. If parameters are changed in the EtherNet/IP Unit, however, the EtherNet/IP Unit will be restarted. When other nodes are communicating with the affected node, the communications will temporarily time out and automatically recover later. *7. Because the EtherNet/IP Unit is equipped with an IGMP client, unnecessary multicast packets can be filtered by using a switching hub that supports IGMP snooping. *8. The EtherNet/IP Unit uses the TCP/UDP port numbers shown in the following table. Service Protocol Port number Remarks CJ1/CJ2 NJ CJ1/CJ2 NJ CJ1/CJ2 NJ Used by system --- UDP --- 2223, 2224 Tag data links UDP 2222 Class3, UCMM TCP/UDP 44818 Fixed value DNS UDP 53 BOOTP client --- UDP --- 68 FINS/UDP service UDP --- 9600 --- FINS/TCP service TCP --- 9600 --- FTP TCP 20, 21 21 SNTP UDP 123 SNMP UDP 161 SNMP trap UDP 162 Port numbers in the Unit Setup can be changed with the CX-Programmer. Port numbers in the Unit Setup can be changed with the Sysmac Studio. *9. When NJ-Series CPU Units is described, Supported only by the EtherNet/IP Units with unit version 2.1 or later and NJ-Series CPU Units with unit version 1.01 or later. 4

Unit Versions and Software Versions The following versions of the Sysmac Studio, CX-Programmer and Network Configurator are required to set EtherNet/IP Units. Yes:Supported, ---:Not supported Sysmac Studio *1 CX-Programmer *2 Network Configurator for EtherNet/IP Ver.1.01 or lower Ver.1.02 Ver.7.1 or lower Ver.8.0 or higher Ver.8.02 or higher Ver.3.40 or lower Ver.3.50 or higher Ver.1.0 --- --- --- Yes *3 Yes Yes Yes Ver.2.0 --- --- --- Yes Yes Yes Yes Ver.2.1 --- Yes --- Yes Yes --- Yes *1. Available only when connecting with NJ-series CPU Units. *2. Available only when connecting with CJ1/CJ2-series CPU Units. *3. The most recent version of the common module for CX-One version 3.@@ must be installed. Network Configurator Requirements The Network Configurator Ver. 3.0 or higher is a software package designed for building, setting, and controlling a multi-vendor EtherNet/IP Network using OMRON's EtherNet/IP. It is included in CX-One version 3.0. The Network Configurator provides the following functions for building, setting, and controlling EtherNet/IP. Item Specification Refer to the CX-One Setup Manual (Cat. No. W463). Operating environment CXONE-AL@@C-V@/CXONE-AL@@D-V@ CS1/CJ1 CJ2 NJ Network Serial interface CPU Unit s Peripheral or RS-232C port CPU Unit s USB or RS-232C port CPU Unit s USB port connection method CPU Unit s Ethernet port Ethernet interface EtherNet/IP Unit s Ethernet port EtherNet/IP Unit s Ethernet port Location on Network A single node address is used (only when directly connected to EtherNet/IP). Number of Units that can be connected to A single Network Configurator per Network (More than one Configurator cannot be used in the same system.) Network The Network configuration can be created and edited regardless of whether the Network Configurator is online or offline. Main Network control functions The Network configuration can be read from a file or the network. functions Configuration functions The EDS files used by the Network Configurator can be installed and deleted. Configurator network configuration files (*.ncf) Supported file formats Configuration files (*.ncf) created using the Network Configurator for EtherNet/IP (version 2) can be imported by selecting External Data - Import from the File Menu. External Interface LED Indicators These indicators display the Unit and network status. Unit number setting switch This rotary switch sets the unit number on the CPU Unit with one hexadecimal digit. Node address setting switches These two rotary switches set the node address for the EtherNet/IP Unit on the EtherNet/IP network with two hexadecimal digits. This setting is also used as the host ID in the default IP address (192.168.250.@). Label showing IP address A label that can be used to show the IP address and subnet mask is provided. Ethernet connector The network is connected with shielded twisted-pair cable. Ethernet Connectors The following standards and specifications apply to the connectors for the Ethernet twisted-pair cable. Electrical specifications: Conforming to IEEE802.3 standards. Connector structure: RJ45 8-pin Modular Connector (conforming to ISO 8877) Connector pin Signal name Abbr. Signal direction 1 Transmission data + TD+ Output 2 Transmission data TD Output 3 Reception data + RD+ Input 4 Not used. 5 Not used. 6 Reception data RD Input 7 Not used. 8 Not used. Hood Frame ground FG 5

Functional Comparsion of EtherNet/IP Functionality Item EtherNet/IP Unit (built-in port on CJ2 CPU Unit) Unit version 1.0 Unit version 2.0 Unit version 2.1 OK:Supported, ---:Not supported Built-in EtherNet/ IP port on NJseries CPU Unit CJ-series Ethernet Unit Tag data link communications service OK OK OK OK --- CIP message communications service OK OK OK OK --- Socket service --- --- --- OK OK File transfer (FTP) --- OK OK OK OK Mail send/receive --- --- --- --- OK Web functions --- --- --- --- OK Automatic adjustment of PLC/Controller s internal clock --- OK OK OK OK Error history OK OK OK OK *1 OK Response to PING command OK OK OK OK OK SNMP/SNMP trap --- OK OK OK --- CIDR function for IP addresses --- OK OK OK --- Online connection via EtherNet/IP using CX-One/Sysmac Studio --- OK OK --- --- Online connection via EtherNet/IP using Network Configurator OK OK OK OK --- Mounting in a Controller with an NJseries CPU Unit --- --- OK *2 --- --- *1. This is equivalent to the event log of the built-in EtherNet/IP port of an NJ-series Controller. *2. You cannot use the following functions if you connect to the CPU Unit through an EtherNet/IP Unit. Going online with a CPU Unit from the Sysmac Studio. (However, you can go online from the Network Configurator.) Troubleshooting from an NS-series PT Dimensions (Unit: mm) 31mm 65mm 90mm 6

Related Manuals W465 W495 W421 W342 Manual number CS1W-EIP21 CJ2H-CPU@@-EIP CJ2M-CPU3@ CS1W-ETN21 CJ1W-ETN21 Model Name Contents CS1G/H-CPU@@H CS1G/H-CPU-@@V1 CS1W-SCU21 CS1W-SCB21/41 CJ1G/H-CPU@@H CJ1G-CPU@@ CJ1W-SCU41 EtherNet/IP Units Operation Manual CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit Ethernet Units Operation Manual Construction of Applications Communications Commands Reference Manual W463 CXONE-AL@@C/D-V@ CX-One Setup Manual Provides information on operating and installing EtherNet/IP Units, including details on basic settings, tag data links, and FINS communications. Refer to the Communications Commands Reference Manual (W342) for details on FINS commands that can be sent to CS-series and CJ-series CPU Units when using the FINS communications service. Refer to the Ethernet Units Operation Manual Construction of Applications (W421) for details on constructing host applications that use FINS communications. Information on using an EtherNet/IP Unit that is connected to an NJ-series CPU Unit is provided. Information is provided on the basic setup, tag data links, and other features. Use this manual together with the NJ-series CPU Unit Hardware User s Manual (Cat. No. W500) and NJ-series CPU Unit Software User s Manual (Cat. No. W501). Provides information on constructing host applications for 100Base-TX Ethernet Units, including functions for sending/receiving mail, socket service, automatic clock adjustment, FTP server functions, and FINS communications. Describes the C-series (Host Link) and FINS communications commands used when sending communications commands to CS-series and CJ-series CPU Units. Describes the setup procedures for the CX-One. Information is also provided on the operating environment for the CX-One. 7

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2012.5 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2012 All Right Reserved.