VIKING PAPR 3350 WELDING HELMET POWERED AIR PURIFYING RESPIRATOR
Clear The Air On Welding Safety Where welding operations are concerned, safety is directly connected to air quality. When welding must be performed in enclosed or other areas where it is difficult to provide effective ventilation or otherwise control exposure to welding fume, the last line of defense is personal protective equipment for the individual operator. The VIKING PAPR (Powered Air Purifying Respirator) provides effective air-purification solution all-day long. The VIKING PAPR is a complete system that purifies ambient air from the shop and delivers filtered, breathable air for as much as eight hours without interruption. The two-speed blower drives filtered air through the hose into a modified VIKING 3350 helmet which has a perfect 1/1/1/1 optical clarity and now also features 4C Lens Technology. A patent pending adjustable baffling system inside the helmet directs air away from eyes to keep them from getting dry. The PAPR system has an OSHA Assigned Protection Factor of 25 (3). Proper ventilation may not always be an option in every welding environment. Bring fume protection and filtered air directly to the operator in difficult environments and keep it there all day with the PAPR. (3) APF=25 for loose fitting Powered Air-Purifying Respiratory according to OSHA 3352-02 2009, when the employer implements a continuing, effective respirator program in compliance with the Respiratory Protection Standard (29 CFR 1910).
See Clearly Now 4C Lens Technology The new 4C ADF Technology improves the performance of the lens in the 4 most important categories to the welder: 1. Clarity - Optical Clarity 1/1/1/1 2. Color - Real Color View 3. Carat - Light Weight 4. Cut - Even Shade From Any Angle The 4C Lens Technology upgrade to Lincoln Electric s VIKING PAPR 3350 welding helmet improves visibility and reduces eye strain by minimizing the traditional lime green coloring in the helmet view screen. 4C technology is ideal for a range of industries such as general fabrication, power generation, shipbuilding, structural, offshore and pipeline that use multiple welding processes, including Stick, MIG and TIG. Whatever the task at hand, 4C technology gives you a clear view to productivity and quality. 3350 PAPR Welding Helmet KP5121-1 Inactive State Active State Previous 1/1/1/1 Inactive NEW 4C Inactive Previous 1/1/1/1 Optical Clarity NEW 4C 1/1/1/1 Clarity
VIKING PAPR - Plenum Two air flow baffles allow users to adjust the air for maximum comfort and prevent drying of the eyes. Comfort, Performance and Efficiency Lightweight and comfortable The blower weight is 2.20 lbs while the entire system weighs in at 6.19 pounds, most of which is in the belt pack and hose and away from the head and shoulders. The low-profile blower in the belt unit allows unrestricted movement. First baffle (Red) - controls ratio of air over forehead vs temples Lasts all day (and then some)* Operators can work a full shift (or more) without interruption. The PAPR comes with a standard battery that outpaces the battery life of competing systems. Additionally, Lincoln offers an extended battery which has a run time of up to 16 hours. This extra battery capacity provides flexibility when working overtime and is a safeguard when the system is not recharged overnight. The system also has audible and vibrating alarms to signal when the battery is low. 16 hrs. 9 hrs. 6 hrs. Miller Lincoln - Standard Battery Lincoln - Extended Battery Miller PAPR with Hard Hat and Titanium 9400 Helmet** Lincoln Electric VIKING PAPR 3350 with Standard Battery Lincoln Electric VIKING PAPR 3350 with Extended Battery Battery Run Time Second baffle (Purple) directs air closer or further from your face Two speeds, consistent delivery The PAPR system maintains a positive pressure at two speeds: 180 and 210 liters per minute. The system automatically adjusts fan speeds to keep airflow constant. *Results based on the following test parameters side by side comparison between the Lincoln Electric K3930-1 and the Miller 9400, on the low flow setting with a 50% blocked filter. **The trademark Titanium 9400 Miller, and Miller Electric are the property of Illinois Tool Works Inc.
PAPR (POWERED AIR-PURIFYING RESPIRATOR) SPECIFICATIONS Product Number K3930-1 PAPR (POWERED AIR-PURIFYING RESPIRATOR) HELMET SPECIFICIATIONS Optical Class 1/1/1/1 (per EN 379) Size of Blower Assembly (W x T x D) 8 x 7.5 x 3 in (203 x 191 x 76 mm) Lens Switching Speed (sec) 1/25,000 Weight of Blower (including battery, belt and filters) 2.20 lb. (1.0 kg) Variable Shade/Control 5-13 Internal Air Flow Operating Temperature Battery Type Battery Charge Time Battery Charges Belt Size¹ Respirator Approval² Assigned Protection Factor³ 25 Low Speed: 180+ Ipm (6+ cfm) High Speed: 210+ Ipm (7.4+ cfm) 23 to 131 F (-5 to 55 C) Lithium Ion (Rechargeable) Three hours 500 charges Helmet Replacement Battery CR 2450 Battery Life (Standard) Charge Alarms Head Gear 29 to 52 in (736 to 1321 mm) NIOSH 42 cfr 84 Approved Powered Air-Purifying Respirator (PAPR) 8 Hours (1) Belt size maximum of 60 in. (1524 mm) with belt extension accessory. (2) Refer to NIOSH respirator approval label for system configuration. (3) APF=25 for loose fitting Powered Air-Purifying Respiratory according to OSHA 3352-02 2009, when the employer implements a continuing, effective respirator program in compliance with the Respiratory Protection Standard (29 CFR 1910). 115 Volt Input Audible and Vibrate FR Flame Retardant Magnifying Cheater Capable Lens Grind Mode Shade/Control Light Sensitivity Control Delay Control Dark to Light (sec) Arc Sensors 4 TIG AMP Rating Helmet Compliance Cartridge Size View Size Blower Assembly ADF Helmet Perfect 1/1/1/1 Optical Clarity The PAPR system is equipped with a VIKING 3350 helmet that offers a top EN 379-1/1/1/1 optical clarity rating. Yes 3.5 Internal Continuous 0.1-1.0 Fully Adjustable DC > 2 Amp AC > 2 Amp ANSI Z87.1-2010, CSA Z94.3, CE US 5.25 x 4.50 in (133 x 114 mm) 3.7 x 3.34 in ( 95 x 85mm) 1 Year Warranty 3 Year Warranty What s Included: Blower Unit VIKING 3350 Black Helmet Head Cover Hose 2 Particulate Filters 29-52 in. Padded Belt Shoulder Strap 120V Battery Charger Duffle Bag Rechargeable Battery Pre-Filter Spark Guard Hose Cover Extra helmet cover lenses: inside quantity 2, outside quantity 5 Instruction Manual
REPLACEMENT PARTS SALES NUMBER DESCRIPTION DIMENSIONS PACKAGE QTY. KP5121-1 VIKING PAPR 3350 Helmet Assembly (PKG includes Headgear and Headcovering) N/A 1 KP2898-1 Outside Cover Lens 5.25 x 4.5 in 5 S27978-32 Outside Cover Lens Seal N/A 1 KP3045-2 3350 Auto-Darkening Lens N/A 1 KP3044-1 Inside Cover Lens 3.53 x 3.73 in 5 S27978-33 Lens Holder N/A 1 KP3942-1 Headgear (including plenum and sweatband) N/A 1 KP3943-1 Sweatband N/A 2 KP3940-1 Headcovering (w/hook and loop attachment) N/A 1 KP3944-1 Blower Assembly (PKG includes filter cover assembly) N/A 1 KP3937-1 Standard Battery (for Viking PAPR) N/A 1 KP3938-1 Extended Battery (for Viking PAPR) N/A 1 KP3934-2 HE Filter Assembly N/A 2 KP3934-6 HE Filter Assembly N/A 6 KP3935-1 Pre-filter N/A 6 KP3936-1 Spark Screen N/A 1 KP3932-1 Battery Charger N/A 1 KP5123-1 PAPR Belt Assembly N/A 1 KP5124-1 Shoulder Strap Assembly N/A 1 KP3939-1 Belt Extension (extends belt to 60 in.) N/A 1 KP5122-1 Hose Assembly with Cover N/A 1 KP3046-100 Cheater Lens 1.00 MAG 2 X 4.25 FRAME, 1.0 MAG 1 KP3046-125 Cheater Lens 1.25 MAG 2 X 4.25 FRAME, 1.25 MAG 1 KP3046-150 Cheater Lens 1.50 MAG 2 X 4.25 FRAME, 1.5 MAG 1 KP3046-175 Cheater Lens 1.75 MAG 2 X 4.25 FRAME, 1.75 MAG 1 KP3046-200 Cheater Lens 2.00 MAG 2 X 4.25 FRAME, 2.0 MAG 1 KP3046-225 Cheater Lens 2.25 MAG 2 X 4.25 FRAME, 2.25 MAG 1 KP3046-250 Cheater Lens 2.50 MAG 2 X 4.25 FRAME, 2.5 MAG 1 K3096-1 Duffle Bag N/A 1
CUSTOMER ASSISTANCE POLICY The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond to inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees, however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty of fitness for any customers particular purpose is specifically disclaimed. Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements. Subject to Change This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits. Publication E14.744 Issue Date 10/17 Lincoln Global, Inc. All Rights Reserved. The Lincoln Electric Company 22801 St. Clair Avenue Cleveland, OH 44117-1199 U.S.A. www.lincolnelectric.com